-
1
-
-
44249116685
-
Digital dentistry: An overview of recent developments for CAD/CAM generated restorations
-
F. Beuer, and J. Schweiger Digital dentistry: an overview of recent developments for CAD/CAM generated restorations British Dental Journal 204 2008 505 511
-
(2008)
British Dental Journal
, vol.204
, pp. 505-511
-
-
Beuer, F.1
Schweiger, J.2
-
2
-
-
52449134942
-
A comparison of fixed prostheses generated from conventional vs digitally scanned dental impressions
-
G.L. Henkel A comparison of fixed prostheses generated from conventional vs digitally scanned dental impressions Compendium of Continuing Education in Dentistry 28 2007 422 431
-
(2007)
Compendium of Continuing Education in Dentistry
, vol.28
, pp. 422-431
-
-
Henkel, G.L.1
-
3
-
-
9944229063
-
Contemporary materials and technologies for all-ceramic fixed partial dentures: A review of the literature
-
A.J. Raigrodski Contemporary materials and technologies for all-ceramic fixed partial dentures: a review of the literature Journal of Prosthetic Dentistry 92 2004 557 562
-
(2004)
Journal of Prosthetic Dentistry
, vol.92
, pp. 557-562
-
-
Raigrodski, A.J.1
-
4
-
-
0037828938
-
Biaxial flexural strength, elastic moduli, and X-ray diffraction characterization of three pressable all-ceramic materials
-
M. Albakry, M. Guazzato, and M.V. Swain Biaxial flexural strength, elastic moduli, and X-ray diffraction characterization of three pressable all-ceramic materials Journal of Prosthetic Dentistry 89 2003 374 380
-
(2003)
Journal of Prosthetic Dentistry
, vol.89
, pp. 374-380
-
-
Albakry, M.1
Guazzato, M.2
Swain, M.V.3
-
5
-
-
79952053618
-
Monolithic CAD/CAM lithium disilicate versus veneered Y-TZP crowns: Comparison of failure modes and reliability after fatigue
-
P.C. Guess, R.A. Zavanelli, N.R.F.A. Silva, E.A. Bonfante, P.G. Coelho, and V.P. Thompson Monolithic CAD/CAM lithium disilicate versus veneered Y-TZP crowns: comparison of failure modes and reliability after fatigue International Journal of Prosthodontics 23 2010 434 442
-
(2010)
International Journal of Prosthodontics
, vol.23
, pp. 434-442
-
-
Guess, P.C.1
Zavanelli, R.A.2
Silva, N.R.F.A.3
Bonfante, E.A.4
Coelho, P.G.5
Thompson, V.P.6
-
6
-
-
80054709246
-
Marginal gap, internal fit, and fracture load of leucite-reinforced ceramic inlays fabricated by CEREC inLab and hot-pressed techniques
-
A. Keshvad, T. Hooshmand, F. Asefzadeh, F. Khalilinejad, M. Alihemmati, and R. van Noort Marginal gap, internal fit, and fracture load of leucite-reinforced ceramic inlays fabricated by CEREC inLab and hot-pressed techniques Journal of Prosthodontics 20 2011 535 540
-
(2011)
Journal of Prosthodontics
, vol.20
, pp. 535-540
-
-
Keshvad, A.1
Hooshmand, T.2
Asefzadeh, F.3
Khalilinejad, F.4
Alihemmati, M.5
Van Noort, R.6
-
7
-
-
0036133921
-
Interface gap size of manually and CAD/CAM-manufactured ceramic inlays/onlays in vitro
-
S. Addi, A. Hedayati-Khams, A. Poya, and G. Sjögren Interface gap size of manually and CAD/CAM-manufactured ceramic inlays/onlays in vitro Journal of Dentistry 30 2002 53 58
-
(2002)
Journal of Dentistry
, vol.30
, pp. 53-58
-
-
Addi, S.1
Hedayati-Khams, A.2
Poya, A.3
Sjögren, G.4
-
8
-
-
77957292587
-
Evaluation of the marginal fit of a zirconia ceramic computer-aided machined (CAM) crown system
-
M.R. Baig, K.B.-C. Tan, and J.I. Nicholls Evaluation of the marginal fit of a zirconia ceramic computer-aided machined (CAM) crown system Journal of Prosthetic Dentistry 104 2010 216 227
-
(2010)
Journal of Prosthetic Dentistry
, vol.104
, pp. 216-227
-
-
Baig, M.R.1
Tan, K.B.-C.2
Nicholls, J.I.3
-
9
-
-
0033628733
-
Determination of the minimum number of marginal gap measurements required for practical in vitro testing
-
M. Groten, D. Axmann, L. Pröbster, and H. Weber Determination of the minimum number of marginal gap measurements required for practical in vitro testing Journal of Prosthetic Dentistry 83 2000 40 49
-
(2000)
Journal of Prosthetic Dentistry
, vol.83
, pp. 40-49
-
-
Groten, M.1
Axmann, D.2
Pröbster, L.3
Weber, H.4
-
10
-
-
33744813282
-
Influence of cavity preparation design on fracture resistance of posterior Leucite-reinforced ceramic restorations
-
C.J. Soares, L.R.M. Martins, R.B. Fonseca, L. Correr-Sobrinho, and A.J. Fernandes Neto Influence of cavity preparation design on fracture resistance of posterior Leucite-reinforced ceramic restorations Journal of Prosthetic Dentistry 95 2006 421 429
-
(2006)
Journal of Prosthetic Dentistry
, vol.95
, pp. 421-429
-
-
Soares, C.J.1
Martins, L.R.M.2
Fonseca, R.B.3
Correr-Sobrinho, L.4
Fernandes Neto, A.J.5
-
11
-
-
84879182149
-
Influence of scanning strategies on the accuracy of digital intraoral scanning systems
-
A. Ender, and A. Mehl Influence of scanning strategies on the accuracy of digital intraoral scanning systems International Journal of Computerized Dentistry 16 2013 11 21
-
(2013)
International Journal of Computerized Dentistry
, vol.16
, pp. 11-21
-
-
Ender, A.1
Mehl, A.2
-
12
-
-
84865176071
-
Application of intra-oral dental scanners in the digital workflow of implantology
-
W.J. van der Meer, F.S. Andriessen, D. Wismeijer, and Y. Ren Application of intra-oral dental scanners in the digital workflow of implantology PLoS ONE 7 2012 e43312
-
(2012)
PLoS ONE
, vol.7
, pp. 43312
-
-
Van Der Meer, W.J.1
Andriessen, F.S.2
Wismeijer, D.3
Ren, Y.4
-
13
-
-
84889078508
-
Recent advances in dental optics. Part I: 3D intraoral scanners for restorative dentistry
-
S. Logozzo, E.M. Zanetti, and G. Franceschini Recent advances in dental optics. Part I: 3D intraoral scanners for restorative dentistry Optics and Lasers in Engineering 54 2014 203 221
-
(2014)
Optics and Lasers in Engineering
, vol.54
, pp. 203-221
-
-
Logozzo, S.1
Zanetti, E.M.2
Franceschini, G.3
-
16
-
-
77957280346
-
Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling
-
A. Syrek, G. Reich, D. Ranftl, C. Klein, B. Cerny, and J. Brodesser Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling Journal of Dentistry 38 2010 553 559
-
(2010)
Journal of Dentistry
, vol.38
, pp. 553-559
-
-
Syrek, A.1
Reich, G.2
Ranftl, D.3
Klein, C.4
Cerny, B.5
Brodesser, J.6
-
17
-
-
84873578014
-
Accuracy of complete-arch dental impressions: A new method of measuring trueness and precision
-
A. Ender, and A. Mehl Accuracy of complete-arch dental impressions: a new method of measuring trueness and precision Journal of Prosthetic Dentistry 109 2013 121 128
-
(2013)
Journal of Prosthetic Dentistry
, vol.109
, pp. 121-128
-
-
Ender, A.1
Mehl, A.2
-
18
-
-
84878338435
-
Randomized controlled clinical trial on the three-dimensional accuracy of fast-set impression materials
-
H. Rudolph, S. Quaas, M. Haim, J. Preißler, M.H. Walter, and R. Koch et al. Randomized controlled clinical trial on the three-dimensional accuracy of fast-set impression materials Clinical Oral Investigations 17 2013 1397 1406
-
(2013)
Clinical Oral Investigations
, vol.17
, pp. 1397-1406
-
-
Rudolph, H.1
Quaas, S.2
Haim, M.3
Preißler, J.4
Walter, M.H.5
Koch, R.6
-
19
-
-
84888638427
-
The clinical accuracy of single crowns exclusively fabricated by digital workflow-The comparison of two systems
-
P.K. Brawek, S. Wolfart, L. Endres, A. Kirsten, and S. Reich The clinical accuracy of single crowns exclusively fabricated by digital workflow-the comparison of two systems Clinical Oral Investigations 17 2013 2119 2125
-
(2013)
Clinical Oral Investigations
, vol.17
, pp. 2119-2125
-
-
Brawek, P.K.1
Wolfart, S.2
Endres, L.3
Kirsten, A.4
Reich, S.5
-
20
-
-
84881612097
-
Accuracy of digital and conventional impression techniques and workflow
-
P. Seelbach, C. Brückel, and B. Wöstmann Accuracy of digital and conventional impression techniques and workflow Clinical Oral Investigations 17 2013 1759 1764
-
(2013)
Clinical Oral Investigations
, vol.17
, pp. 1759-1764
-
-
Seelbach, P.1
Brückel, C.2
Wöstmann, B.3
-
22
-
-
84879134365
-
Accuracy of dies captured by an intraoral digital impression system using parallel confocal imaging
-
S.-Y. Kim, M.-J. Kim, J.-S. Han, I.-S. Yeo, Y.-J. Lim, and H.-B. Kwon Accuracy of dies captured by an intraoral digital impression system using parallel confocal imaging International Journal of Prosthodontics 26 2013 161 163
-
(2013)
International Journal of Prosthodontics
, vol.26
, pp. 161-163
-
-
Kim, S.-Y.1
Kim, M.-J.2
Han, J.-S.3
Yeo, I.-S.4
Lim, Y.-J.5
Kwon, H.-B.6
-
23
-
-
84894547254
-
Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques
-
10.1007/s00784-013-0987-2 [Epub ahead of printà
-
J.S. Almeida e Silva, K. Erdelt, D. Edelhoff, É. Araújo, M. Stimmelmayr, and L.C.C. Vieira et al. Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques Clinical Oral Investigations 2013 10.1007/s00784-013-0987-2 [Epub ahead of printà
-
(2013)
Clinical Oral Investigations
-
-
Almeida Silva E, J.S.1
Erdelt, K.2
Edelhoff, D.3
Araújo, É.4
Stimmelmayr, M.5
Vieira, L.C.C.6
-
24
-
-
84875218263
-
Three-dimensional fit of lithium disilicate partial crowns in vitro
-
O. Schäfer, H. Kuepper, B.W. Sigusch, G.A. Thompson, A.F. Hefti, and A. Guentsch Three-dimensional fit of lithium disilicate partial crowns in vitro Journal of Dentistry 41 2013 271 277
-
(2013)
Journal of Dentistry
, vol.41
, pp. 271-277
-
-
Schäfer, O.1
Kuepper, H.2
Sigusch, B.W.3
Thompson, G.A.4
Hefti, A.F.5
Guentsch, A.6
-
25
-
-
84880736310
-
Effect of CNC-milling on the marginal and internal fit of dental ceramics: A pilot study
-
O. Schäfer, H. Kuepper, G.A. Thompson, G. Cachovan, A.F. Hefti, and A. Guentsch Effect of CNC-milling on the marginal and internal fit of dental ceramics: a pilot study Dental Materials 29 2013 851 858
-
(2013)
Dental Materials
, vol.29
, pp. 851-858
-
-
Schäfer, O.1
Kuepper, H.2
Thompson, G.A.3
Cachovan, G.4
Hefti, A.F.5
Guentsch, A.6
-
26
-
-
84873572868
-
Accuracy of ceramic restorations made with two CAD/CAM systems
-
T.A. Hamza, H.A. Ezzat, M.M.K. El-Hossary, H.A.E.M. Katamish, T.E. Shokry, and S.F. Rosenstiel Accuracy of ceramic restorations made with two CAD/CAM systems Journal of Prosthetic Dentistry 109 2013 83 87
-
(2013)
Journal of Prosthetic Dentistry
, vol.109
, pp. 83-87
-
-
Hamza, T.A.1
Ezzat, H.A.2
El-Hossary, M.M.K.3
Katamish, H.A.E.M.4
Shokry, T.E.5
Rosenstiel, S.F.6
-
28
-
-
84937684298
-
Accuracy of a digital impression system based on active wavefront sampling technology for implants considering operator experience implant angulation, and depth
-
10.1111/cid.12124 [Epub ahead of printà
-
B. Giménez, M. Özcan, F. Martínez-Rus, and G. Pradíes Accuracy of a digital impression system based on active wavefront sampling technology for implants considering operator experience implant angulation, and depth Clinical Implant Dentistry and Related Research 2013 10.1111/cid.12124 [Epub ahead of printà
-
(2013)
Clinical Implant Dentistry and Related Research
-
-
Giménez, B.1
Özcan, M.2
Martínez-Rus, F.3
Pradíes, G.4
|