Volumn 52, Issue 3, 2014, Pages 499-518

Clinical Implementation of Digital Breast Tomosynthesis

Author keywords

Breast cancer; Breast imaging; Digital breast tomosynthesis; Digital mammography; Screening mammography

Indexed keywords

ALGORITHM; BREAST; BREAST CALCIFICATION; BREAST CANCER; BREAST DENSITY; BREAST EXAMINATION; CANCER SCREENING; COMPUTER ASSISTED DETECTION; DATA PROCESSING; DIAGNOSTIC ACCURACY; DIAGNOSTIC IMAGING; DIGITAL BREAST TOMOSYNTHESIS; DIGITAL MAMMOGRAPHY; DIGITAL RADIOGRAPHY; HUMAN; IMAGE ANALYSIS; IMAGE PROCESSING; IMAGE QUALITY; IMAGE RECONSTRUCTION; LEARNING CURVE; MEDICAL EDUCATION; PRIORITY JOURNAL; RADIATION DOSE; REIMBURSEMENT; REVIEW; SENSITIVITY AND SPECIFICITY; THREE DIMENSIONAL IMAGING; TOMOGRAPHY;

EID: 84899895730     PISSN: 00338389     EISSN: 15578275     Source Type: Journal    
DOI: 10.1016/j.rcl.2013.11.013     Document Type: Review
Times cited : (48)

References (52)
  • 1
    • 72049100691 scopus 로고    scopus 로고
    • Screening for breast cancer: US Preventive Services Task Force recommendation statement
    • US Preventive Services Task Force Screening for breast cancer: US Preventive Services Task Force recommendation statement. Ann Intern Med 2009, 151(10):716-726.
    • (2009) Ann Intern Med , vol.151 , Issue.10 , pp. 716-726
  • 2
    • 27344458270 scopus 로고    scopus 로고
    • Diagnostic performance of digital versus film mammography for breast cancer screening
    • Pisano E.D., Gatsonis C., Hendrick E., et al. Diagnostic performance of digital versus film mammography for breast cancer screening. NEngl J Med 2005, 353:1773-1783.
    • (2005) NEngl J Med , vol.353 , pp. 1773-1783
    • Pisano, E.D.1    Gatsonis, C.2    Hendrick, E.3
  • 3
    • 84860389648 scopus 로고    scopus 로고
    • Swedish two-county trial: impact of mammographic screening on breast cancer mortality during 3 decades
    • Tabar L., Vitak B., Chen T.H., et al. Swedish two-county trial: impact of mammographic screening on breast cancer mortality during 3 decades. Radiology 2011, 260(3):658-663.
    • (2011) Radiology , vol.260 , Issue.3 , pp. 658-663
    • Tabar, L.1    Vitak, B.2    Chen, T.H.3
  • 4
    • 84861845969 scopus 로고    scopus 로고
    • Digital breast tomosynthesis (DBT): initial experience in a clinical setting
    • Skaane P., Gullien R., Bjorndal H., et al. Digital breast tomosynthesis (DBT): initial experience in a clinical setting. Acta Radiol 2012, 53:524-529.
    • (2012) Acta Radiol , vol.53 , pp. 524-529
    • Skaane, P.1    Gullien, R.2    Bjorndal, H.3
  • 5
    • 84871680074 scopus 로고    scopus 로고
    • Assessing radiologist performance using combined digital mammography and breast tomosynthesis compared with digital mammography alone: results of a multicenter, multireader trial
    • Rafferty E.A., Park J.M., Philpotts L.E., et al. Assessing radiologist performance using combined digital mammography and breast tomosynthesis compared with digital mammography alone: results of a multicenter, multireader trial. Radiology 2013, 266(1):104-113.
    • (2013) Radiology , vol.266 , Issue.1 , pp. 104-113
    • Rafferty, E.A.1    Park, J.M.2    Philpotts, L.E.3
  • 6
    • 84874960822 scopus 로고    scopus 로고
    • Comparison of digital mammography alone and digital mammography plus tomosynthesis in a population-based screening program
    • Skaane P., Bandos A.I., Gullien R., et al. Comparison of digital mammography alone and digital mammography plus tomosynthesis in a population-based screening program. Radiology 2013, 267:47-56.
    • (2013) Radiology , vol.267 , pp. 47-56
    • Skaane, P.1    Bandos, A.I.2    Gullien, R.3
  • 7
    • 84865722006 scopus 로고    scopus 로고
    • Acomparison of the accuracy offilm-screen mammography, full-field digital mammography, and digital breast tomosynthesis
    • Michell M.J., Iqbal A., Wasan R.K., et al. Acomparison of the accuracy offilm-screen mammography, full-field digital mammography, and digital breast tomosynthesis. Clin Radiol 2012, 67:976-981.
    • (2012) Clin Radiol , vol.67 , pp. 976-981
    • Michell, M.J.1    Iqbal, A.2    Wasan, R.K.3
  • 8
    • 80052347102 scopus 로고    scopus 로고
    • Breast tomosynthesis: state-of-the-art and review of the literature
    • Baker J.A., Lo J.Y. Breast tomosynthesis: state-of-the-art and review of the literature. Acad Radiol 2011, 18(10):1298-1310.
    • (2011) Acad Radiol , vol.18 , Issue.10 , pp. 1298-1310
    • Baker, J.A.1    Lo, J.Y.2
  • 9
    • 77956909535 scopus 로고    scopus 로고
    • Digital mammography imaging: breast tomosynthesis and advanced applications
    • Helvie M.A. Digital mammography imaging: breast tomosynthesis and advanced applications. Radiol Clin North Am 2010, 48:917-929.
    • (2010) Radiol Clin North Am , vol.48 , pp. 917-929
    • Helvie, M.A.1
  • 10
    • 78649928376 scopus 로고    scopus 로고
    • Digital breast tomosynthesis
    • Baldwin P. Digital breast tomosynthesis. Radiol Technol 2009, 81:57-74.
    • (2009) Radiol Technol , vol.81 , pp. 57-74
    • Baldwin, P.1
  • 11
    • 84899967669 scopus 로고    scopus 로고
    • Available at: Accessed March 30, 2013.
    • Available at: Accessed March 30, 2013. http://breasttomo.com/sites/default/files/010-WP-00060-Rev2_June2012-TomoWhitePaper.pdf.
  • 12
    • 84899925440 scopus 로고    scopus 로고
    • Available at: Accessed March 30, 2013.
    • Available at: Accessed March 30, 2013. http://www.accessdata.fda.gov/cdrh_docs/pdf8/P080003b.pdf.
  • 13
    • 77953333258 scopus 로고    scopus 로고
    • The diagnostic accuracy of dual-view digital mammography, single view breast tomosynthesis and dual-view combination of breast tomosynthesis and digital mammography in a free-response observer performance study
    • Svahn T., Anderson I., Chakraborty D., et al. The diagnostic accuracy of dual-view digital mammography, single view breast tomosynthesis and dual-view combination of breast tomosynthesis and digital mammography in a free-response observer performance study. Radiat Prot Dosimetry 2010, 139:113-117.
    • (2010) Radiat Prot Dosimetry , vol.139 , pp. 113-117
    • Svahn, T.1    Anderson, I.2    Chakraborty, D.3
  • 14
    • 79952266901 scopus 로고    scopus 로고
    • Localized detection and classification of abnormalities on FFDM and tomosynthesis examinations rated under an FROC paradigm
    • Gur D., Adams G.S., Chough D.M., et al. Localized detection and classification of abnormalities on FFDM and tomosynthesis examinations rated under an FROC paradigm. AJR Am J Roentgenol 2011, 196:737-741.
    • (2011) AJR Am J Roentgenol , vol.196 , pp. 737-741
    • Gur, D.1    Adams, G.S.2    Chough, D.M.3
  • 15
    • 84858713666 scopus 로고    scopus 로고
    • Two-view and single-view tomosynthesis versus full-field digital mammography: high resolution X-ray imaging observer study
    • Wallis M.G., Moa E., Zanca F., et al. Two-view and single-view tomosynthesis versus full-field digital mammography: high resolution X-ray imaging observer study. Radiology 2012, 262:788-796.
    • (2012) Radiology , vol.262 , pp. 788-796
    • Wallis, M.G.1    Moa, E.2    Zanca, F.3
  • 16
    • 84455167880 scopus 로고    scopus 로고
    • Digital breast tomosynthesis is comparable to mammographic spot views for mass characterization
    • Noroozian M., Hadjiiski L., Rahnama-Moghadam S., et al. Digital breast tomosynthesis is comparable to mammographic spot views for mass characterization. Radiology 2012, 262:61-68.
    • (2012) Radiology , vol.262 , pp. 61-68
    • Noroozian, M.1    Hadjiiski, L.2    Rahnama-Moghadam, S.3
  • 17
    • 84860316410 scopus 로고    scopus 로고
    • Prospective study of breast tomosynthesis as a triage to assessment in screening
    • Bernardi D., Ciatto S., Pellegrini M., et al. Prospective study of breast tomosynthesis as a triage to assessment in screening. Breast Cancer Res Treat 2012, 133:267-271.
    • (2012) Breast Cancer Res Treat , vol.133 , pp. 267-271
    • Bernardi, D.1    Ciatto, S.2    Pellegrini, M.3
  • 18
    • 84879697513 scopus 로고    scopus 로고
    • Implementation of breast tomosynthesis in a routine screening practice: an observational study
    • Rose S.L., Tidwell A.L., Bujnoch L.J., et al. Implementation of breast tomosynthesis in a routine screening practice: an observational study. American journal of roentgenology 2013, 200(6):1401-1408.
    • (2013) American journal of roentgenology , vol.200 , Issue.6 , pp. 1401-1408
    • Rose, S.L.1    Tidwell, A.L.2    Bujnoch, L.J.3
  • 19
    • 84886420800 scopus 로고    scopus 로고
    • Comparison of tomosynthesis plus digital mammography and digital mammography alone for breast cancer screening
    • Haas B.M., Kalra V., Geisel J., et al. Comparison of tomosynthesis plus digital mammography and digital mammography alone for breast cancer screening. Radiology 2013, 269(3):694-700.
    • (2013) Radiology , vol.269 , Issue.3 , pp. 694-700
    • Haas, B.M.1    Kalra, V.2    Geisel, J.3
  • 20
    • 84899943387 scopus 로고    scopus 로고
    • Digital Breast Tomosynthesis in Combination with Digital Mammography Compared to Digital Mammography Alone: A "Natural Experiment" in General-Population Screening Outcomes in preparation (personal communications)
    • Conant EF, McCarthy AM, Kontos D, etal. Digital Breast Tomosynthesis in Combination with Digital Mammography Compared to Digital Mammography Alone: A "Natural Experiment" in General-Population Screening Outcomes in preparation (personal communications) 2014.
    • (2014)
    • Conant, E.F.1    McCarthy, A.M.2    Kontos, D.3
  • 21
    • 34548225376 scopus 로고    scopus 로고
    • Digital breast tomosynthesis: initial experience in 98 women with abnormal digital screening mammography
    • Poplack S.P., Tosteson T.D., Kogel C.A., et al. Digital breast tomosynthesis: initial experience in 98 women with abnormal digital screening mammography. American Journal of Roentgenology 2007, 189(3):616-623.
    • (2007) American Journal of Roentgenology , vol.189 , Issue.3 , pp. 616-623
    • Poplack, S.P.1    Tosteson, T.D.2    Kogel, C.A.3
  • 22
    • 84856623198 scopus 로고    scopus 로고
    • One-to-one comparison between digital spot compression view and digital breast tomosynthesis
    • Tagliafico A., Astengo D., Cavagnetto F., et al. One-to-one comparison between digital spot compression view and digital breast tomosynthesis. EurRadiol 2012, 22:539-544.
    • (2012) EurRadiol , vol.22 , pp. 539-544
    • Tagliafico, A.1    Astengo, D.2    Cavagnetto, F.3
  • 23
    • 77954818863 scopus 로고    scopus 로고
    • Digital breast tomosynthesis versus digital mammography: a clinical performance study
    • Gennaro G., Toledano A., di Maggio C., et al. Digital breast tomosynthesis versus digital mammography: a clinical performance study. Eur Radiol 2010, 20:1545-1553.
    • (2010) Eur Radiol , vol.20 , pp. 1545-1553
    • Gennaro, G.1    Toledano, A.2    di Maggio, C.3
  • 24
    • 84899896724 scopus 로고    scopus 로고
    • Assessing radiologist performance using combined full-field digital mammography andbreast tomosynthesis versus full-field digital mammography alone: results of a multi-center multi-reader trial. Presented at the Radiological Society of North America annual meeting. Chicago (IL)
    • Rafferty E, Niklason L, Halpern E, etal. Assessing radiologist performance using combined full-field digital mammography andbreast tomosynthesis versus full-field digital mammography alone: results of a multi-center multi-reader trial. Presented at the Radiological Society of North America annual meeting. Chicago (IL), 2007.
    • (2007)
    • Rafferty, E.1    Niklason, L.2    Halpern, E.3
  • 25
    • 0028972903 scopus 로고
    • UKCCCR multicentre randomized controlled trial of one and two view mammography in breast cancer screening
    • Wald N.J., Murphy P., Major P., et al. UKCCCR multicentre randomized controlled trial of one and two view mammography in breast cancer screening. BMJ 1995, 311:1189-1193.
    • (1995) BMJ , vol.311 , pp. 1189-1193
    • Wald, N.J.1    Murphy, P.2    Major, P.3
  • 26
    • 84899969715 scopus 로고    scopus 로고
    • Breast tomosynthesis: one view or two? Presented at the Radiological Society of North America annual meeting. Chicago (IL)
    • Rafferty E, Niklason L, Jameson-Meehan L. Breast tomosynthesis: one view or two? Presented at the Radiological Society of North America annual meeting. Chicago (IL), 2006.
    • (2006)
    • Rafferty, E.1    Niklason, L.2    Jameson-Meehan, L.3
  • 27
    • 68149165447 scopus 로고    scopus 로고
    • Digital breast tomosynthesis: observer performance study
    • Gur D., Abrams G.S., Chough D.M., et al. Digital breast tomosynthesis: observer performance study. AJR Am J Roentgenol 2009, 193:586-591.
    • (2009) AJR Am J Roentgenol , vol.193 , pp. 586-591
    • Gur, D.1    Abrams, G.S.2    Chough, D.M.3
  • 28
    • 84871703598 scopus 로고    scopus 로고
    • Digital breast tomosynthesis versus supplemental diagnostic mammographic views for evaluation of noncalcified breast lesions
    • Zuley M.L., Bandoss A.I., Ganott M.A., et al. Digital breast tomosynthesis versus supplemental diagnostic mammographic views for evaluation of noncalcified breast lesions. Radiology 2013, 266:89-95.
    • (2013) Radiology , vol.266 , pp. 89-95
    • Zuley, M.L.1    Bandoss, A.I.2    Ganott, M.A.3
  • 29
    • 84873591639 scopus 로고    scopus 로고
    • Can digital breast tomosynthesis replace conventional diagnostic mammography views for screening recalls without calcifications? A comparison study in a simulated clinical setting
    • Brandt K.R., Craig D.A., Hoskins T.L., et al. Can digital breast tomosynthesis replace conventional diagnostic mammography views for screening recalls without calcifications? A comparison study in a simulated clinical setting. AJR Am J Roentgenol 2013, 200(2):291-298.
    • (2013) AJR Am J Roentgenol , vol.200 , Issue.2 , pp. 291-298
    • Brandt, K.R.1    Craig, D.A.2    Hoskins, T.L.3
  • 30
    • 84871872729 scopus 로고    scopus 로고
    • Value of one-view breast tomosynthesis versus two-view mammography in diagnostic workup of women with clinical signs and symptoms and in women recalled from screening
    • Waldherr C., Cerny P., Altermatt H.J., et al. Value of one-view breast tomosynthesis versus two-view mammography in diagnostic workup of women with clinical signs and symptoms and in women recalled from screening. AJR Am J Roentgenol 2013, 200(1):226-231.
    • (2013) AJR Am J Roentgenol , vol.200 , Issue.1 , pp. 226-231
    • Waldherr, C.1    Cerny, P.2    Altermatt, H.J.3
  • 31
    • 77955620924 scopus 로고    scopus 로고
    • Digital breast tomosynthesis inthe diagnostic environment: a subjective side-by-side review
    • Hakim C.M., Chough D.M., Ganott M.A., et al. Digital breast tomosynthesis inthe diagnostic environment: a subjective side-by-side review. AJR Am J Roentgenol 2010, 195(2):172-176.
    • (2010) AJR Am J Roentgenol , vol.195 , Issue.2 , pp. 172-176
    • Hakim, C.M.1    Chough, D.M.2    Ganott, M.A.3
  • 32
    • 77749268123 scopus 로고    scopus 로고
    • Breast tomosynthesis: accuracy oftumor measurement compared with digital mammography and ultrasonography
    • Fornvik D., Zackrisson S., Ljungberg O., et al. Breast tomosynthesis: accuracy oftumor measurement compared with digital mammography and ultrasonography. Acta Radiol 2010, 3:240-247.
    • (2010) Acta Radiol , vol.3 , pp. 240-247
    • Fornvik, D.1    Zackrisson, S.2    Ljungberg, O.3
  • 33
    • 84899937951 scopus 로고    scopus 로고
    • The accuracy of breast cancer size measurement: digital breast tomosynthesis (DBT0 vs. 2D digital mammography (DM)). Presented at the European College of Radiology annual meeting. Vienna (Austria)
    • Meacock LM, Mombelloni S, Iqbal A, etal. The accuracy of breast cancer size measurement: digital breast tomosynthesis (DBT0 vs. 2D digital mammography (DM)). Presented at the European College of Radiology annual meeting. Vienna (Austria), 2010.
    • (2010)
    • Meacock, L.M.1    Mombelloni, S.2    Iqbal, A.3
  • 34
    • 80755153217 scopus 로고    scopus 로고
    • Calcifications in the breast and digital breast tomosynthesis
    • Kopans D., Gavenonis S., Halpern E., et al. Calcifications in the breast and digital breast tomosynthesis. Breast J 2011, 17(6):638-644.
    • (2011) Breast J , vol.17 , Issue.6 , pp. 638-644
    • Kopans, D.1    Gavenonis, S.2    Halpern, E.3
  • 35
    • 79251478742 scopus 로고    scopus 로고
    • Detection and classification of calcifications on digital breast tomosynthesis and 2D digital mammography: a comparison
    • Spangler M.L., Zuley M., Sumkin J. Detection and classification of calcifications on digital breast tomosynthesis and 2D digital mammography: a comparison. AJR Am J Roentgenol 2011, 196:320-324.
    • (2011) AJR Am J Roentgenol , vol.196 , pp. 320-324
    • Spangler, M.L.1    Zuley, M.2    Sumkin, J.3
  • 36
    • 58149191786 scopus 로고    scopus 로고
    • Cutaneous caves and subcutaneous adipose columns in the breast: radiologic-pathologic correlation
    • Kopans D.B., Rusby J.E. Cutaneous caves and subcutaneous adipose columns in the breast: radiologic-pathologic correlation. Radiology 2008, 249(3):779-784.
    • (2008) Radiology , vol.249 , Issue.3 , pp. 779-784
    • Kopans, D.B.1    Rusby, J.E.2
  • 37
    • 84861302992 scopus 로고    scopus 로고
    • Clinical digital breast tomosynthesis system: dosimetric characterization
    • Feng S.S., Sechopoulos I. Clinical digital breast tomosynthesis system: dosimetric characterization. Radiology 2012, 263:35-42.
    • (2012) Radiology , vol.263 , pp. 35-42
    • Feng, S.S.1    Sechopoulos, I.2
  • 38
    • 84855256999 scopus 로고    scopus 로고
    • Dose reduction in digital breast tomosynthesis (DBT) screening using synthetically reconstructed projection images: an observer performance study
    • Gur D., Zuley M.L., Anello M.I., et al. Dose reduction in digital breast tomosynthesis (DBT) screening using synthetically reconstructed projection images: an observer performance study. Acad Radiol 2012, 19:166-171.
    • (2012) Acad Radiol , vol.19 , pp. 166-171
    • Gur, D.1    Zuley, M.L.2    Anello, M.I.3
  • 39
    • 84875522763 scopus 로고    scopus 로고
    • Overview of the evidence on digital breast tomosynthesis in breast cancer detection
    • Houssami N., Skaane P. Overview of the evidence on digital breast tomosynthesis in breast cancer detection. Breast 2013, 22(2):101-108. 10.1016/j.breast.2013.01.017.
    • (2013) Breast , vol.22 , Issue.2 , pp. 101-108
    • Houssami, N.1    Skaane, P.2
  • 40
    • 84899994727 scopus 로고    scopus 로고
    • Available at: Accessed March 21, 2013.
    • Available at: Accessed March 21, 2013. http://www.fda.gov/downloads/AdvisoryCommittees/CommitteesMeetingMaterials/MedicalDevices/MedicalDevicesAdvisoryCommittee/RadiologicalDevicesPanel/UCM328613.pdf.
  • 41
    • 50449109489 scopus 로고    scopus 로고
    • Computer-aided detection of masses in digital tomosynthesis mammography: comparison of three approaches
    • Chan H.P., Wei J., Zhang Y., et al. Computer-aided detection of masses in digital tomosynthesis mammography: comparison of three approaches. Med Phys 2008, 35:4087-4095.
    • (2008) Med Phys , vol.35 , pp. 4087-4095
    • Chan, H.P.1    Wei, J.2    Zhang, Y.3
  • 42
    • 27744556063 scopus 로고    scopus 로고
    • Computer-aided detection system for breast masses on digital tomosynthesis mammograms: preliminary experience
    • Chan H.P., Wei J., Sahiner B., et al. Computer-aided detection system for breast masses on digital tomosynthesis mammograms: preliminary experience. Radiology 2005, 237:1075-1080.
    • (2005) Radiology , vol.237 , pp. 1075-1080
    • Chan, H.P.1    Wei, J.2    Sahiner, B.3
  • 43
    • 48349099068 scopus 로고    scopus 로고
    • Automated breast mass detection in 3D reconstructed tomosynthesis volumes: a featureless approach
    • Singh S., Tourassi G.D., Baker J.A., et al. Automated breast mass detection in 3D reconstructed tomosynthesis volumes: a featureless approach. Med Phys 2008, 35:3626-3636.
    • (2008) Med Phys , vol.35 , pp. 3626-3636
    • Singh, S.1    Tourassi, G.D.2    Baker, J.A.3
  • 44
    • 31844448002 scopus 로고    scopus 로고
    • Computerized mass detection for digital breast tomosynthesis directly from the projection images
    • Reiser I., Nishikawa R.M., Giger M.L., et al. Computerized mass detection for digital breast tomosynthesis directly from the projection images. Med Phys 2006, 33:482-491.
    • (2006) Med Phys , vol.33 , pp. 482-491
    • Reiser, I.1    Nishikawa, R.M.2    Giger, M.L.3
  • 45
    • 41449102812 scopus 로고    scopus 로고
    • Automated detection of microcalcification clusters for digital breast tomosynthesis using projection data only: a preliminary study
    • Reiser I., Nishikawa R.M., Edwards A.V., et al. Automated detection of microcalcification clusters for digital breast tomosynthesis using projection data only: a preliminary study. Med Phys 2008, 35:1486-1493.
    • (2008) Med Phys , vol.35 , pp. 1486-1493
    • Reiser, I.1    Nishikawa, R.M.2    Edwards, A.V.3
  • 46
    • 42449091003 scopus 로고    scopus 로고
    • Digital breast tomosynthesis: a pilot observer study
    • Good W.F., Abrams G.S., Catullo V.J., et al. Digital breast tomosynthesis: a pilot observer study. AJR Am J Roentgenol 2008, 190:865-869.
    • (2008) AJR Am J Roentgenol , vol.190 , pp. 865-869
    • Good, W.F.1    Abrams, G.S.2    Catullo, V.J.3
  • 47
    • 84871167237 scopus 로고    scopus 로고
    • Application of breast tomosynthesis in screening: incremental effect on mammography acquisition and reading time
    • Bernardi D., Ciatto S., Pellegrini M., et al. Application of breast tomosynthesis in screening: incremental effect on mammography acquisition and reading time. Br J Radiol 2012, 85:1174-1178.
    • (2012) Br J Radiol , vol.85 , pp. 1174-1178
    • Bernardi, D.1    Ciatto, S.2    Pellegrini, M.3
  • 48
    • 84899991862 scopus 로고    scopus 로고
    • Available at: Accessed March 21, 2013.
    • Available at: Accessed March 21, 2013. http://www.auntminnie.com/index.aspx?sec=sup%26sub=wom%26pag=dis%26ItemID=102872%26wf=5368.
  • 49
    • 84899984609 scopus 로고    scopus 로고
    • Mammography Quality Standard Act requirements. Available at: Accessed March 21, 2013.
    • Mammography Quality Standard Act requirements. Available at: Accessed March 21, 2013. http://www.fda.gov/radiation-emittingproducts/mammographyqualitystandardsactandprogram/facilitycertificationandinspection/ucm243765.htm.
  • 50
    • 84899981640 scopus 로고    scopus 로고
    • Available at: Accessed March 21, 2013.
    • Available at: Accessed March 21, 2013. http://gm.acr.org/Hidden/Economics/FeaturedCategories/Pubs/coding_source/archives/MayJun2011/QA.aspx.
  • 51
    • 84899989330 scopus 로고    scopus 로고
    • Available at: Accessed March 21, 2013.
    • Available at: Accessed March 21, 2013. http://www.okbreastcare.com/tomo.html.
  • 52
    • 84899961059 scopus 로고    scopus 로고
    • Available at: Accessed March 21, 2013.
    • Available at: Accessed March 21, 2013. http://www.breastimaginghouston.com/news.html.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.