Volumn 263, Issue 1, 2012, Pages 35-42

Clinical digital breast tomosynthesis system: Dosimetric characterization

Author keywords

[No Author keywords available]

Indexed keywords

AIR KERMA; ARTICLE; AUTOMATIC EXPOSURE CONTROL; CANCER SCREENING; CONTROLLED STUDY; DIGITAL BREAST TOMOSYNTHESIS; DIGITAL MAMMOGRAPHY; DOSIMETRY; FILM DOSIMETER; FULL FIELD DIGITAL MAMMOGRAPHY; IMAGING AND DISPLAY; MEAN GLANDULAR DOSE; MEDICAL DEVICE; MONTE CARLO METHOD; PHANTOM; PRIORITY JOURNAL; RADIATION DOSE; RADIOLOGICAL PARAMETERS; TWO DIMENSIONAL THREE DIMENSIONAL FUSION IMAGING; X RAY TUBE; BREAST TUMOR; FEMALE; HUMAN; IMAGE QUALITY; MAMMOGRAPHY; METHODOLOGY; RADIOGRAPHY; RADIOMETRY; THREE DIMENSIONAL IMAGING;

EID: 84861302992     PISSN: 00338419     EISSN: 15271315     Source Type: Journal    
DOI: 10.1148/radiol.11111789     Document Type: Article
Times cited : (143)

References (29)
  • 2
    • 3042639644 scopus 로고    scopus 로고
    • Digital tomosynthesis mammography using a parallel maximum-likelihood reconstruction method
    • Wu T, Zhang J, Moore R, et al. Digital tomosynthesis mammography using a parallel maximum-likelihood reconstruction method. Proc SPIE 2004;5368:1-11.
    • (2004) Proc SPIE , vol.5368 , pp. 1-11
    • Wu, T.1    Zhang, J.2    Moore, R.3
  • 3
    • 33845927292 scopus 로고    scopus 로고
    • Computation of the glandular radiation dose in digital tomosynthesis of the breast
    • DOI 10.1118/1.2400836
    • Sechopoulos I, Suryanarayanan S, Vedantham S, D'Orsi C, Karellas A. Computation of the glandular radiation dose in digital tomosynthesis of the breast. Med Phys 2007;34(1):221-232. (Pubitemid 46035245)
    • (2007) Medical Physics , vol.34 , Issue.1 , pp. 221-232
    • Sechopoulos, I.1    Suryanarayanan, S.2    Vedantham, S.3    D'Orsi, C.4    Karellas, A.5
  • 6
    • 34548225376 scopus 로고    scopus 로고
    • Digital breast tomosynthesis: Initial experience in 98 women with abnormal digital screening mammography
    • DOI 10.2214/AJR.07.2231
    • Poplack SP, Tosteson TD, Kogel CA, Nagy HM. Digital breast tomosynthesis: initial experience in 98 women with abnormal digital screening mammography. AJR Am J Roentgenol 2007;189(3):616-623. (Pubitemid 47328544)
    • (2007) American Journal of Roentgenology , vol.189 , Issue.3 , pp. 616-623
    • Poplack, S.P.1    Tosteson, T.D.2    Kogel, C.A.3    Nagy, H.M.4
  • 7
    • 56349132626 scopus 로고    scopus 로고
    • Breast tomosynthesis and digital mammography: A comparison of breast cancer visibility and BIRADS classification in a population of cancers with subtle mammographic findings
    • Andersson I, Ikeda DM, Zackrisson S, et al. Breast tomosynthesis and digital mammography: a comparison of breast cancer visibility and BIRADS classification in a population of cancers with subtle mammographic findings. Eur Radiol 2008;18(12):2817-2825.
    • (2008) Eur Radiol , vol.18 , Issue.12 , pp. 2817-2825
    • Andersson, I.1    Ikeda, D.M.2    Zackrisson, S.3
  • 8
    • 68149165447 scopus 로고    scopus 로고
    • Digital breast tomosynthesis: Observer performance study
    • Gur D, Abrams GS, Chough DM, et al. Digital breast tomosynthesis: observer performance study. AJR Am J Roentgenol 2009;193(2):586-591.
    • (2009) AJR Am J Roentgenol , vol.193 , Issue.2 , pp. 586-591
    • Gur, D.1    Abrams, G.S.2    Chough, D.M.3
  • 9
    • 70049086220 scopus 로고    scopus 로고
    • Glandular radiation dose in tomosynthesis of the breast using tungsten targets
    • Sechopoulos I, D'Orsi CJ. Glandular radiation dose in tomosynthesis of the breast using tungsten targets. J Appl Clin Med Phys 2008;9(4):2887.
    • (2008) J Appl Clin Med Phys , vol.9 , Issue.4 , pp. 2887
    • Sechopoulos, I.1    D'Orsi, C.J.2
  • 10
    • 56749156991 scopus 로고    scopus 로고
    • Mean glandular dose estimation using MCNPX for a digital breast tomosynthesis system with tungsten/aluminum and tungsten/aluminum+silver x-ray anodefilter combinations
    • Ma AKW, Darambara DG, Stewart A, Gunn S, Bullard E. Mean glandular dose estimation using MCNPX for a digital breast tomosynthesis system with tungsten/aluminum and tungsten/aluminum+silver x-ray anodefilter combinations. Med Phys 2008;35(12):5278-5289.
    • (2008) Med Phys , vol.35 , Issue.12 , pp. 5278-5289
    • Ma, A.K.W.1    Darambara, D.G.2    Stewart, A.3    Gunn, S.4    Bullard, E.5
  • 11
    • 79551654977 scopus 로고    scopus 로고
    • Estimation of mean glandular dose for breast tomosynthesis: Factors for use with the UK, European and IAEA breast dosimetry protocols
    • Dance DR, Young KC, van Engen RE. Estimation of mean glandular dose for breast tomosynthesis: factors for use with the UK, European and IAEA breast dosimetry protocols. Phys Med Biol 2011;56(2):453-471.
    • (2011) Phys Med Biol , vol.56 , Issue.2 , pp. 453-471
    • Dance, D.R.1    Young, K.C.2    Van Engen, R.E.3
  • 12
    • 79955759528 scopus 로고    scopus 로고
    • A new generation FFDM/tomosynthesis fusion system with selenium detector
    • Ren B, Ruth C, Wu T, et al. A new generation FFDM/tomosynthesis fusion system with selenium detector. Proc SPIE 2010;7622:76220B-76211.
    • (2010) Proc SPIE , vol.7622
    • Ren, B.1    Ruth, C.2    Wu, T.3
  • 13
    • 35648976045 scopus 로고    scopus 로고
    • Dual-energy approach to contrast-enhanced mammography using the balanced filter method: Spectral optimization and preliminary phantom measurement
    • DOI 10.1118/1.2790841
    • Saito M. Dual-energy approach to contrast-enhanced mammography using the balanced filter method: spectral optimization and preliminary phantom measurement. Med Phys 2007;34(11):4236-4246. (Pubitemid 350029645)
    • (2007) Medical Physics , vol.34 , Issue.11 , pp. 4236-4246
    • Saito, M.1
  • 14
    • 78149482580 scopus 로고    scopus 로고
    • Dosimetric characterization of a dedicated breast computed tomography clinical prototype
    • Sechopoulos I, Feng SSJ, D'Orsi CJ. Dosimetric characterization of a dedicated breast computed tomography clinical prototype. Med Phys 2010;37(8):4110-4120.
    • (2010) Med Phys , vol.37 , Issue.8 , pp. 4110-4120
    • Sechopoulos, I.1    Feng, S.S.J.2    D'Orsi, C.J.3
  • 15
    • 72049102861 scopus 로고    scopus 로고
    • The myth of the 50-50 breast
    • Yaffe MJ, Boone JM, Packard N, et al. The myth of the 50-50 breast. Med Phys 2009;36(12):5437-5443.
    • (2009) Med Phys , vol.36 , Issue.12 , pp. 5437-5443
    • Yaffe, M.J.1    Boone, J.M.2    Packard, N.3
  • 16
    • 0031466296 scopus 로고    scopus 로고
    • Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography
    • DOI 10.1118/1.598100
    • Boone JM, Fewell TR, Jennings RJ. Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography. Med Phys 1997;24(12):1863-1874. (Pubitemid 28013501)
    • (1997) Medical Physics , vol.24 , Issue.12 , pp. 1863-1874
    • Boone, J.M.1    Fewell, T.R.2    Jennings, R.J.3
  • 20
    • 0032886446 scopus 로고    scopus 로고
    • Glandular breast dose for monoenergetic and high-energy x-ray beams: Monte Carlo assessment
    • Boone JM. Glandular breast dose for monoenergetic and high-energy X-ray beams: Monte Carlo assessment. Radiology 1999;213(1):23-37. (Pubitemid 29470402)
    • (1999) Radiology , vol.213 , Issue.1 , pp. 23-37
    • Boone, J.M.1
  • 22
    • 0035999415 scopus 로고    scopus 로고
    • Normalized glandular dose (DgN) coefficients for arbitrary x-ray spectra in mammography: Computer-fit values of Monte Carlo derived data
    • DOI 10.1118/1.1472499
    • Boone JM. Normalized glandular dose (DgN) coefficients for arbitrary X-ray spectra in mammography: computer-fit values of Monte Carlo derived data. Med Phys 2002;29(5):869-875. (Pubitemid 34525916)
    • (2002) Medical Physics , vol.29 , Issue.5 , pp. 869-875
    • Boone, J.M.1
  • 23
    • 0018316082 scopus 로고
    • Absorbed radiation dose in mammography
    • Hammerstein GR, Miller DW, White DR, Masterson ME, Woodard HQ, Laughlin JS. Absorbed radiation dose in mammography. Radiology 1979;130(2):485-491. (Pubitemid 9070569)
    • (1979) Radiology , vol.130 , Issue.2 , pp. 485-491
    • Hammsterstein, G.R.1    Miller, D.W.2    White, D.R.3
  • 24
  • 25
    • 76149099559 scopus 로고    scopus 로고
    • Comparison of acquisition parameters and breast dose in digital mammography and screen-film mammography in the American College of Radiology Imaging Network digital mammographic imaging screening trial
    • Hendrick RE, Pisano ED, Averbukh A, et al. Comparison of acquisition parameters and breast dose in digital mammography and screen-film mammography in the American College of Radiology Imaging Network digital mammographic imaging screening trial. AJR Am J Roentgenol 2010;194(2):362-369.
    • (2010) AJR Am J Roentgenol , vol.194 , Issue.2 , pp. 362-369
    • Hendrick, R.E.1    Pisano, E.D.2    Averbukh, A.3
  • 27
    • 34548660847 scopus 로고    scopus 로고
    • Digital Mammography: Novel Applications
    • DOI 10.1016/j.rcl.2007.06.005, PII S0033838907000930, Breast Imaging
    • Rafferty EA. Digital mammography: novel applications. Radiol Clin North Am 2007;45(5):831-843, vii. (Pubitemid 47411641)
    • (2007) Radiologic Clinics of North America , vol.45 , Issue.5 , pp. 831-843
    • Rafferty, E.A.1
  • 28
    • 0037650183 scopus 로고    scopus 로고
    • A study of mean glandular dose during diagnostic mammography in Malaysia and some of the factors affecting it
    • DOI 10.1259/bjr/66428508
    • Jamal N, Ng KH, McLean D. A study of mean glandular dose during diagnostic mammography in Malaysia and some of the factors affecting it. Br J Radiol 2003;76(904):238-245. (Pubitemid 36582068)
    • (2003) British Journal of Radiology , vol.76 , Issue.904 , pp. 238-245
    • Jamal, N.1    Ng, K.-H.2    McLean, D.3
  • 29
    • 0034078815 scopus 로고    scopus 로고
    • Radiation doses received in the UK Breast Screening Programme in 1997 and 1998
    • Young KC, Burch A. Radiation doses received in the UK Breast Screening Programme in 1997 and 1998. Br J Radiol 2000;73(867):278-287. (Pubitemid 30192800)
    • (2000) British Journal of Radiology , vol.73 , Issue.867 , pp. 278-287
    • Young, K.C.1    Burch, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.