메뉴 건너뛰기




Volumn 199, Issue , 2014, Pages 190-200

SPR based fibre optic ammonia gas sensor utilizing nanocomposite film of PMMA/reduced graphene oxide prepared by in situ polymerization

Author keywords

Ammonia gas; Optical fibre; Poly(methyl methacrylate) PMMA ; Reduced graphene oxide (rGO); Sensor; Surface plasmon

Indexed keywords

ACRYLIC MONOMERS; AMMONIA; CHEMICAL SENSORS; COATINGS; ELECTROMAGNETIC FIELDS; ESTERS; GAS DETECTORS; GASES; GRAPHENE; NANOCOMPOSITE FILMS; NANOCOMPOSITES; NITROGEN; OPTICAL FIBERS; PLASMONS; PROBES; REUSABILITY; SEMICONDUCTOR DOPING; SENSORS;

EID: 84899642021     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2014.03.109     Document Type: Article
Times cited : (252)

References (58)
  • 1
    • 0027575999 scopus 로고
    • Fiber-optic chemical sensor based on surface plasmon resonance
    • R.C. Jorgenson, and S.S. Yee A fibre-optic chemical sensor based on surface plasmon resonance Sens. Actuators B 12 1993 213 220 (Pubitemid 23708558)
    • (1993) Sensors and Actuators, B: Chemical , vol.B12 , Issue.3 , pp. 213-220
    • Jorgenson, R.C.1    Yee, S.S.2
  • 2
    • 34247635052 scopus 로고    scopus 로고
    • Surface plasmon resonance based fiber-optic sensor for the detection of pesticide
    • DOI 10.1016/j.snb.2006.10.001, PII S0925400506006812
    • R. Jha, S. Chand, and B.D. Gupta Surface plasmon resonance based fibre optic sensor for the detection of pesticide Sens. Actuators B 123 2007 661 666 (Pubitemid 46678753)
    • (2007) Sensors and Actuators, B: Chemical , vol.123 , Issue.2 , pp. 661-666
    • Rajan1    Chand, S.2    Gupta, B.D.3
  • 3
    • 33846293986 scopus 로고    scopus 로고
    • Recent advancements in surface plasmon resonance immunosensors for detection of small molecules of biomedical, food and environmental interest
    • DOI 10.1016/j.snb.2006.09.014, PII S0925400506006368
    • D.R. Shankaran, K.V. Gobi, and N. Miura Recent advancements in surface plasmon resonance immuno sensors for detection of small molecules of biomedical, food and environmental interest Sens. Actuators B 12 2007 158 177 (Pubitemid 46123891)
    • (2007) Sensors and Actuators, B: Chemical , vol.121 , Issue.1 , pp. 158-177
    • Shankaran, D.R.1    Gobi, K.V.2    Miura, N.3
  • 5
    • 84859174187 scopus 로고    scopus 로고
    • Figure of merit enhancement of surface plasmon resonance sensors in the spectral interrogation
    • A. Shalabney, and I. Abdulhalim Figure of merit enhancement of surface plasmon resonance sensors in the spectral interrogation Opt. Lett. 37 2012 1175 1177
    • (2012) Opt. Lett. , vol.37 , pp. 1175-1177
    • Shalabney, A.1    Abdulhalim, I.2
  • 6
    • 84860148852 scopus 로고    scopus 로고
    • Clinical application of surface plasmon resonance-based biosensors for fetal fibronectin detection
    • C.Y. Chen, C.C. Chang, C. Yu, and C.W. Lin Clinical application of surface plasmon resonance-based biosensors for fetal fibronectin detection Sensors 12 2012 3879 3890
    • (2012) Sensors , vol.12 , pp. 3879-3890
    • Chen, C.Y.1    Chang, C.C.2    Yu, C.3    Lin, C.W.4
  • 7
    • 84871734573 scopus 로고    scopus 로고
    • Fabrication and characterization of a surface plasmon resonance based fiber optic sensor using gel entrapment technique for the detection of low glucose concentration
    • S. Singh, and B.D. Gupta Fabrication and characterization of a surface plasmon resonance based fiber optic sensor using gel entrapment technique for the detection of low glucose concentration Sens. Actuators B 177 2013 589 595
    • (2013) Sens. Actuators B , vol.177 , pp. 589-595
    • Singh, S.1    Gupta, B.D.2
  • 8
    • 84881292781 scopus 로고    scopus 로고
    • Sensors based on surface plasmon resonance in plastic optical fiber for the detection of trinitrotoluene
    • N. Cennamo, G.D. Agostino, R. Galatus, L. Bibbo, M. Pesavento, and L. Zeni Sensors based on surface plasmon resonance in plastic optical fiber for the detection of trinitrotoluene Sens. Actuators B 188 2013 221 226
    • (2013) Sens. Actuators B , vol.188 , pp. 221-226
    • Cennamo, N.1    Agostino, G.D.2    Galatus, R.3    Bibbo, L.4    Pesavento, M.5    Zeni, L.6
  • 9
    • 84941216114 scopus 로고
    • Radiative decay of non-radiative surface plasmons excited by light
    • E. Kretschmann, and H. Raether Radiative decay of non-radiative surface plasmons excited by light Nature 23 1968 2135 2136
    • (1968) Nature , vol.23 , pp. 2135-2136
    • Kretschmann, E.1    Raether, H.2
  • 10
    • 14744288530 scopus 로고    scopus 로고
    • A surface plasmon resonance system for the measurement of glucose in aqueous solution
    • DOI 10.1016/j.snb.2004.04.088, PII S0925400504002977
    • W.W. Lam, L.H. Chu, C.L. Wong, and Y.T. Zhang A surface plasmon resonance system for the measurement of glucose in aqueous solution Sens. Actuators B 105 2005 138 143 (Pubitemid 40330080)
    • (2005) Sensors and Actuators, B: Chemical , vol.105 , Issue.2 , pp. 138-143
    • Lam, W.W.1    Chu, L.H.2    Wong, C.L.3    Zhang, Y.T.4
  • 12
    • 84882372531 scopus 로고    scopus 로고
    • Constructing a novel asymmetric dielectric structure toward the realization of high-performance surface plasmon biosensors
    • N.F. Chiu, W.C. Lee, and T.S. Jiang Constructing a novel asymmetric dielectric structure toward the realization of high-performance surface plasmon biosensors IEEE Sens. J. 13 2013 3483 3489
    • (2013) IEEE Sens. J. , vol.13 , pp. 3483-3489
    • Chiu, N.F.1    Lee, W.C.2    Jiang, T.S.3
  • 14
    • 84866239777 scopus 로고    scopus 로고
    • Fiber optic waveguide coupled surface plasmon resonance sensor
    • J.H. Ahn, T.Y. Seong, W.M. Kim, T.S. Lee, I. Kim, and K.S. Lee Fiber optic waveguide coupled surface plasmon resonance sensor Opt. Express 20 2012 21729 21738
    • (2012) Opt. Express , vol.20 , pp. 21729-21738
    • Ahn, J.H.1    Seong, T.Y.2    Kim, W.M.3    Lee, T.S.4    Kim, I.5    Lee, K.S.6
  • 15
    • 84875844488 scopus 로고    scopus 로고
    • Surface plasmon resonance based fiber optic pH sensor utilizing Ag/ITO/Al/hydrogel layers
    • S.K. Mishra, and B.D. Gupta Surface plasmon resonance based fiber optic pH sensor utilizing Ag/ITO/Al/hydrogel layers Analyst 138 2013 2640 2646
    • (2013) Analyst , vol.138 , pp. 2640-2646
    • Mishra, S.K.1    Gupta, B.D.2
  • 16
    • 34248582002 scopus 로고    scopus 로고
    • On the performance of different bimetallic combinations in surface plasmon resonance based fibre optic sensors
    • A.K. Sharma, and B.D. Gupta On the performance of different bimetallic combinations in surface plasmon resonance based fibre optic sensors J. Appl. Phys. 101 2007 93 111
    • (2007) J. Appl. Phys. , vol.101 , pp. 93-111
    • Sharma, A.K.1    Gupta, B.D.2
  • 17
    • 81155133675 scopus 로고    scopus 로고
    • Sensitivity enhancement of a surface plasmon resonance based biomolecules sensor using graphene and silicon layers
    • R. Verma, B.D. Gupta, and R. Jha Sensitivity enhancement of a surface plasmon resonance based biomolecules sensor using graphene and silicon layers Sens. Actuators B 160 2011 623 631
    • (2011) Sens. Actuators B , vol.160 , pp. 623-631
    • Verma, R.1    Gupta, B.D.2    Jha, R.3
  • 19
    • 33847690144 scopus 로고    scopus 로고
    • The rise of graphene
    • DOI 10.1038/nmat1849, PII NMAT1849
    • A.K. Geim, and K.S. Novoselov The rise of graphene Nat. Mater. 6 2007 183 191 (Pubitemid 46353764)
    • (2007) Nature Materials , vol.6 , Issue.3 , pp. 183-191
    • Geim, A.K.1    Novoselov, K.S.2
  • 23
    • 61349153502 scopus 로고    scopus 로고
    • Radio frequency nanowire resonators and in-situ frequency tuning
    • G. Lu, L.E. Ocola, and J. Chen Radio frequency nanowire resonators and in-situ frequency tuning Appl. Phys. Lett. 94 2009 83111 83113
    • (2009) Appl. Phys. Lett. , vol.94 , pp. 83111-83113
    • Lu, G.1    Ocola, L.E.2    Chen, J.3
  • 27
    • 0034723410 scopus 로고    scopus 로고
    • Short-channel effects in contact-passivated nanotubes chemical sensors
    • J. Kong, N.R. Franklin, C. Zhou, M.G. Chapline, S. Peng, K. Cho, and H. Dai Short-channel effects in contact-passivated nanotubes chemical sensors Science 287 2000 622 625
    • (2000) Science , vol.287 , pp. 622-625
    • Kong, J.1    Franklin, N.R.2    Zhou, C.3    Chapline, M.G.4    Peng, S.5    Cho, K.6    Dai, H.7
  • 28
    • 84864284488 scopus 로고    scopus 로고
    • Surface plasmon resonance based fiber optic ammonia gas sensor using ITO and polyaniline
    • S.K. Mishra, D. Kumari, and B.D. Gupta Surface plasmon resonance based fiber optic ammonia gas sensor using ITO and polyaniline Sens. Actuators B 171-172 2012 976 983
    • (2012) Sens. Actuators B , vol.171-172 , pp. 976-983
    • Mishra, S.K.1    Kumari, D.2    Gupta, B.D.3
  • 29
  • 30
    • 33748329692 scopus 로고    scopus 로고
    • Role of defects in single-walled carbon nanotube chemical sensors
    • DOI 10.1021/nl0612289
    • J.A. Robinson, E.S. Snow, S.C.adescu, T.L. Reinecke, and F.K. Perkins Role of defects in single walled carbon nanotube chemical sensors Nano Lett. 6 2006 1747 1751 (Pubitemid 44327541)
    • (2006) Nano Letters , vol.6 , Issue.8 , pp. 1747-1751
    • Robinson, J.A.1    Snow, E.S.2    Badescu, S.C.3    Reinecke, T.L.4    Perkins, F.K.5
  • 32
    • 0030044667 scopus 로고    scopus 로고
    • Chronic lung disease secondary to ammonia inhalation injury: A report on three cases
    • DOI 10.1002/(SICI)1097-0274(199602)29:2<209::AID-AJIM12>3.0.CO;2-7
    • R.E. de la Hoz, D.P. Schueter, and W.N. Rom Chronic lung disease secondary to ammonia inhalation injury: a report on three cases Am. J. Indus. Med. 29 1996 209 214 (Pubitemid 26043425)
    • (1996) American Journal of Industrial Medicine , vol.29 , Issue.2 , pp. 209-214
    • De La Hoz, R.E.1    Schlueter, D.P.2    Rom, W.N.3
  • 33
    • 0026918901 scopus 로고
    • Mass ammonia inhalation burns experience in the management of 12 patients
    • C.M. Leung, and C.L. Foo Mass ammonia inhalation burns experience in the management of 12 patients Ann. Acad. Med. Singapore 21 1992 624 629
    • (1992) Ann. Acad. Med. Singapore , vol.21 , pp. 624-629
    • Leung, C.M.1    Foo, C.L.2
  • 34
    • 0032878338 scopus 로고    scopus 로고
    • Emergency planning and the acute toxic potency of inhaled ammonia
    • R.A. Michaels Emergency planning and the acute toxic potency of inhaled ammonia Environ. Health Perspect. 107 1999 617 627 (Pubitemid 29412772)
    • (1999) Environmental Health Perspectives , vol.107 , Issue.8 , pp. 617-627
    • Michaels, R.A.1
  • 35
    • 0018891938 scopus 로고
    • Acute and chronic effects of ammonia burns of the respiratory tract
    • L.G. Close, F.I. Catlin, and A.M. Cohn Acute and chronic effects of ammonia burns of the respiratory tract Arch. Otolaryngol. 106 1980 151 158 (Pubitemid 10130283)
    • (1980) Archives of Otolaryngology , vol.106 , Issue.3 , pp. 151-158
    • Close, L.G.1    Catlin, F.I.2    Cohn, A.M.3
  • 37
    • 0035898946 scopus 로고    scopus 로고
    • Mixed oxides as gas sensors
    • DOI 10.1016/S0040-6090(01)00987-7, PII S0040609001009877
    • K. Zakrzewska Mixed oxides as gas sensors Thin Solid Film 391 2001 229 238 (Pubitemid 32576165)
    • (2001) Thin Solid Films , vol.391 , Issue.2 , pp. 229-238
    • Zakrzewska, K.1
  • 43
    • 33645167928 scopus 로고    scopus 로고
    • Selectivity of Ti-doped In2O3 ceramics as an ammonia sensor
    • P. Guo, and H. Pan Selectivity of Ti-doped In2O3 ceramics as an ammonia sensor Sens. Actuators B 114 2006 762 767
    • (2006) Sens. Actuators B , vol.114 , pp. 762-767
    • Guo, P.1    Pan, H.2
  • 44
    • 0020750513 scopus 로고
    • Characteristics of semiconductor gas sensors I. Steady state gas response
    • P.K. Clifford, and D.T. Tuma Characteristics of semiconductor gas sensors I. Steady state gas response Sens. Actuators B 3 1983 233 254
    • (1983) Sens. Actuators B , vol.3 , pp. 233-254
    • Clifford, P.K.1    Tuma, D.T.2
  • 45
    • 55249087681 scopus 로고    scopus 로고
    • Room temperature ammonia gas sensing using mixed conductor based TEMPOS structures
    • M. Saroch, S. Srivastava, D. Fink, and A. Chandra Room temperature ammonia gas sensing using mixed conductor based TEMPOS structures Sensors 8 2008 6355 6370
    • (2008) Sensors , vol.8 , pp. 6355-6370
    • Saroch, M.1    Srivastava, S.2    Fink, D.3    Chandra, A.4
  • 46
    • 79952454844 scopus 로고    scopus 로고
    • Room temperature ammonia sensors based on zinc oxide and functionalized graphite and multi-walled carbon nanotubes
    • J.M. Tulliani, A. Cavalieri, S. Musso, E. Sardella, and F. Geobaldo Room temperature ammonia sensors based on zinc oxide and functionalized graphite and multi-walled carbon nanotubes Sens. Actuators B 152 2011 144 154
    • (2011) Sens. Actuators B , vol.152 , pp. 144-154
    • Tulliani, J.M.1    Cavalieri, A.2    Musso, S.3    Sardella, E.4    Geobaldo, F.5
  • 50
    • 0030348772 scopus 로고    scopus 로고
    • Ammonia sensors based on sensitive polyaniline films
    • DOI 10.1016/S0925-4005(97)80128-1, PII S092540059601996X
    • A.L. Kukla, Y.M. Shirshov, and S.A. Piletsky Ammonia sensors based on sensitive polyaniline films Sens. Actuators B 37 1996 135 140 (Pubitemid 126394724)
    • (1996) Sensors and Actuators, B: Chemical , vol.37 , Issue.3 , pp. 135-140
    • Kukla, A.L.1    Shirshov, Yu.M.2    Piletsky, S.A.3
  • 51
    • 84879979081 scopus 로고    scopus 로고
    • Electrical and mechanical properties of PMMA/reduced graphene oxide nanocomposites prepared via in situ polymerization
    • S.N. Tripathi, P. Saini, D. Gupta, and V. Choudhary Electrical and mechanical properties of PMMA/reduced graphene oxide nanocomposites prepared via in situ polymerization J. Mater. Sci. 48 2013 6223 6232
    • (2013) J. Mater. Sci. , vol.48 , pp. 6223-6232
    • Tripathi, S.N.1    Saini, P.2    Gupta, D.3    Choudhary, V.4
  • 53
    • 84863607651 scopus 로고    scopus 로고
    • Graphene based chemical sensors
    • F. Yavari, and N. Koratkar Graphene based chemical sensors J. Phys. Chem. Lett. 3 2013 1746 1753
    • (2013) J. Phys. Chem. Lett. , vol.3 , pp. 1746-1753
    • Yavari, F.1    Koratkar, N.2
  • 54
    • 0141741721 scopus 로고    scopus 로고
    • Alcohol vapor sensors based on single-walled carbon nanotube field effect transistors
    • DOI 10.1021/nl034061h
    • T. Someya, J. Small, P. Kim, C. Nuckolls, and J.T. Yardley Alcohol vapor sensors based on single-walled carbon nanotube field effect transistors Nano Lett. 3 2003 877 881 (Pubitemid 37161864)
    • (2003) Nano Letters , vol.3 , Issue.7 , pp. 877-881
    • Someya, T.1    Small, J.2    Kim, P.3    Nuckolls, C.4    Yardley, J.T.5
  • 56
    • 0037116553 scopus 로고    scopus 로고
    • Chemical defect decoration of carbon nanotubes
    • DOI 10.1002/1521-4095(20020116)14:2<130::AID-ADMA130>3.0.CO;2-Z
    • Y. Fan, M. Burghard, and K. Kern Chemical defect decoration of carbon nanotubes Adv. Mater. 14 2002 130 133 (Pubitemid 34091532)
    • (2002) Advanced Materials , vol.14 , Issue.2 , pp. 130-133
    • Fan, Y.1    Burghard, M.2    Kern, K.3
  • 57
    • 0034723410 scopus 로고    scopus 로고
    • Nanotube molecular wires as chemical sensors
    • DOI 10.1126/science.287.5453.622
    • J. Kong, N.R. Franklin, C. Zhou, M.G. Chapline, S. Peng, K. Cho, and H. Dai Nanotube molecular wires as chemical sensors Science 287 2000 622 625 (Pubitemid 30070903)
    • (2000) Science , vol.287 , Issue.5453 , pp. 622-625
    • Kong, J.1    Franklin, N.R.2    Zhou, C.3    Chapline, M.G.4    Peng, S.5    Cho, K.6    Dai, H.7
  • 58


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.