A comparison of alignment using patient specific guides, computer navigation and conventional instrumentation in total knee arthroplasty

Author keywords

Alignment; Conventional; Patient specific guides

Indexed keywords

AGED; ARTICLE; AXIAL ALIGNMENT; COMPARATIVE EFFECTIVENESS; COMPUTER ASSISTED SURGERY SYSTEM; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; CONVENTIONAL INSTRUMENTATION; CORONAL ALIGNMENT; HIP KNEE ANGLE; HUMAN; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MEASUREMENT ACCURACY; MUSCULOSKELETAL SYSTEM PARAMETERS; OPERATION DURATION; ORTHOPEDIC SURGERY; OUTCOME ASSESSMENT; PATIENT SPECIFIC GUIDE; POSTOPERATIVE PERIOD; PREOPERATIVE PERIOD; PRIORITY JOURNAL; SAGITTAL ALIGNMENT; SURGICAL EQUIPMENT; SURGICAL NAVIGATION SYSTEM; TOTAL KNEE REPLACEMENT; COHORT ANALYSIS; COMPARATIVE STUDY; COMPUTER ASSISTED SURGERY; KNEE; KNEE ARTHROPLASTY; KNEE PROSTHESIS; PROCEDURES; PROSTHESIS; RADIOGRAPHY; SURGERY;

EID: 84898596325     PISSN: 09680160     EISSN: 18735800     Source Type: Journal    
DOI: 10.1016/j.knee.2013.11.004     Document Type: Article
Times cited : (61)

References (18)
  • 1
    • 58149354595 scopus 로고    scopus 로고
    • Results of an initial experience with custom-fit positioning total knee arthroplasty in a series of 48 patients
    • Howell S.M., Kuznik K., Hull M.L., Siston R.A. Results of an initial experience with custom-fit positioning total knee arthroplasty in a series of 48 patients. Orthopedics 2008, 31:857.
    • (2008) Orthopedics , vol.31 , pp. 857
    • Howell, S.M.1    Kuznik, K.2    Hull, M.L.3    Siston, R.A.4
  • 2
    • 84855562280 scopus 로고    scopus 로고
    • Cost-effectiveness analysis of custom total knee cutting blocks
    • Slover J.D., Rubash H.E., Malchau H., Bosco J.A. Cost-effectiveness analysis of custom total knee cutting blocks. J Arthroplasty 2012, 27:180.
    • (2012) J Arthroplasty , vol.27 , pp. 180
    • Slover, J.D.1    Rubash, H.E.2    Malchau, H.3    Bosco, J.A.4
  • 4
    • 84874668905 scopus 로고    scopus 로고
    • A prospective randomised controlled study of patient-specific cutting guides compared with conventional instrumentation in total knee replacement
    • Chareancholvanich K., Narkbunnam R., Pornrattanamaneewong C. A prospective randomised controlled study of patient-specific cutting guides compared with conventional instrumentation in total knee replacement. J Bone Joint Surg Br 2013, 95-B:354.
    • (2013) J Bone Joint Surg Br , pp. 354
    • Chareancholvanich, K.1    Narkbunnam, R.2    Pornrattanamaneewong, C.3
  • 5
    • 84865102501 scopus 로고    scopus 로고
    • Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA
    • Ng V., DeClaire J.H., Berend K.R., Gulick B.C., Lombardi A.V. Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA. Clin Orthop Relat Res 2012, 470:99.
    • (2012) Clin Orthop Relat Res , vol.470 , pp. 99
    • Ng, V.1    DeClaire, J.H.2    Berend, K.R.3    Gulick, B.C.4    Lombardi, A.V.5
  • 6
    • 84861188144 scopus 로고    scopus 로고
    • Custom-fit total knee arthroplasty: our initial experience in 32 knees
    • Bali K., Walker P., Bruce W. Custom-fit total knee arthroplasty: our initial experience in 32 knees. J Arthroplasty 2012, 27.
    • (2012) J Arthroplasty , pp. 27
    • Bali, K.1    Walker, P.2    Bruce, W.3
  • 8
    • 36749020620 scopus 로고    scopus 로고
    • Meta-analysis of alignment outcomes in computer-assisted total knee arthroplasty surgery
    • Mason J.B., Fehring T.K., Estok R., Banel D., Fahrbach K. Meta-analysis of alignment outcomes in computer-assisted total knee arthroplasty surgery. J Arthroplasty 2007, 22:1097.
    • (2007) J Arthroplasty , vol.22 , pp. 1097
    • Mason, J.B.1    Fehring, T.K.2    Estok, R.3    Banel, D.4    Fahrbach, K.5
  • 11
    • 67349252516 scopus 로고    scopus 로고
    • Does accurate anatomical alignment result in better function and quality of life? Comparing conventional and computer-assisted total knee arthroplasty
    • Choong P.F., Dowsey M.M., Stoney J.D. Does accurate anatomical alignment result in better function and quality of life? Comparing conventional and computer-assisted total knee arthroplasty. J Arthroplasty 2009, 24:560.
    • (2009) J Arthroplasty , vol.24 , pp. 560
    • Choong, P.F.1    Dowsey, M.M.2    Stoney, J.D.3
  • 12
    • 4444262696 scopus 로고    scopus 로고
    • Computer-assisted total knee replacement. A Controlled Cadaver Study using a Multi-Parameter Quantitative CT Assessment of Alignment (The Perth CT Protocol)
    • Chauhan S.K., Clark G.W., Lloyd S., Scott R.G., Breidahl W., Sikorski J.M. Computer-assisted total knee replacement. A Controlled Cadaver Study using a Multi-Parameter Quantitative CT Assessment of Alignment (The Perth CT Protocol). J Bone Joint Surg Br 2004, 86:818.
    • (2004) J Bone Joint Surg Br , vol.86 , pp. 818
    • Chauhan, S.K.1    Clark, G.W.2    Lloyd, S.3    Scott, R.G.4    Breidahl, W.5    Sikorski, J.M.6
  • 13
    • 0029976887 scopus 로고
    • Effect of rotation and knee flexion on radiographic alignment in total knee arthroplasties
    • Lonner J.H., Laird M.T., Stuchin S.A. Effect of rotation and knee flexion on radiographic alignment in total knee arthroplasties. Clin Orthop 1991, 331:102.
    • (1991) Clin Orthop , vol.331 , pp. 102
    • Lonner, J.H.1    Laird, M.T.2    Stuchin, S.A.3
  • 14
    • 39849084917 scopus 로고    scopus 로고
    • Learning curve in navigated total knee replacement. A multi-centre study comparing experienced and beginner centres
    • Jenny J.Y., Miehlke R.K., Giurea A. Learning curve in navigated total knee replacement. A multi-centre study comparing experienced and beginner centres. Knee 2008, 15:80.
    • (2008) Knee , vol.15 , pp. 80
    • Jenny, J.Y.1    Miehlke, R.K.2    Giurea, A.3
  • 15
    • 38949126595 scopus 로고    scopus 로고
    • Periprosthetic femoral supracondylar fracture after total knee arthroplasty with navigation system
    • Li C.H., Chen T.H., Su Y.P., Shao P.C., Lee K.S., Chen W.M. Periprosthetic femoral supracondylar fracture after total knee arthroplasty with navigation system. J Arthroplasty 2008, 23:304.
    • (2008) J Arthroplasty , vol.23 , pp. 304
    • Li, C.H.1    Chen, T.H.2    Su, Y.P.3    Shao, P.C.4    Lee, K.S.5    Chen, W.M.6
  • 16
    • 36049010038 scopus 로고    scopus 로고
    • The cost-effectiveness of computer-assisted navigation in total knee arthroplasty
    • Novak E.J., Silverstein M.D., Bozic K.J. The cost-effectiveness of computer-assisted navigation in total knee arthroplasty. J Bone Joint Surg Am 2007, 89:2389.
    • (2007) J Bone Joint Surg Am , vol.89 , pp. 2389
    • Novak, E.J.1    Silverstein, M.D.2    Bozic, K.J.3
  • 17
    • 37349078592 scopus 로고    scopus 로고
    • Custom-fit total knee arthroplasty (OtisKnee) results in malalignment
    • Klatt B.A., Goyal N., Austin M.S., Hozack W.J. Custom-fit total knee arthroplasty (OtisKnee) results in malalignment. J Arthroplasty 2008, 23:26.
    • (2008) J Arthroplasty , vol.23 , pp. 26
    • Klatt, B.A.1    Goyal, N.2    Austin, M.S.3    Hozack, W.J.4
  • 18
    • 58149343701 scopus 로고    scopus 로고
    • Patient-specific approach in total knee arthroplasty
    • Lombardi A.V., Berend K.R., Adams J.B. Patient-specific approach in total knee arthroplasty. Orthopedics 2008, 31:927.
    • (2008) Orthopedics , vol.31 , pp. 927
    • Lombardi, A.V.1    Berend, K.R.2    Adams, J.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.