-
1
-
-
43449126798
-
Initial evaluation of coronary images from 320-detector row computed tomography
-
Rybicki F. J., Otero H. J., Steigner M. L., et al. Initial evaluation of coronary images from 320-detector row computed tomography. Int J Cardiovasc Imaging: 2008; 24 5 535 546
-
(2008)
Int J Cardiovasc Imaging
, vol.24
, Issue.5
, pp. 535-546
-
-
Rybicki, F.J.1
Otero, H.J.2
Steigner, M.L.3
-
3
-
-
73649113284
-
Radiation dose reduction in computed tomography: Techniques and future perspective
-
Yu L., Liu X., Leng S., et al. Radiation dose reduction in computed tomography: techniques and future perspective. Imaging Med: 2009; 1 1 65 84
-
(2009)
Imaging Med
, vol.1
, Issue.1
, pp. 65-84
-
-
Yu, L.1
Liu, X.2
Leng, S.3
-
4
-
-
48249097524
-
The technology of MRI-The next 10 years
-
Blamire A. M. The technology of MRI-the next 10 years? Br J Radiol: 2008; 81 968 601 617
-
(2008)
Br J Radiol
, vol.81
, Issue.968
, pp. 601-617
-
-
Blamire, A.M.1
-
5
-
-
69949090502
-
Recent advances in MRI of articular cartilage
-
Gold G. E., Chen C. A., Koo S., Hargreaves B. A., Bangerter N. K. Recent advances in MRI of articular cartilage. AJR Am J Roentgenol: 2009; 193 3 628 638
-
(2009)
AJR Am J Roentgenol
, vol.193
, Issue.3
, pp. 628-638
-
-
Gold, G.E.1
Chen, C.A.2
Koo, S.3
Hargreaves, B.A.4
Bangerter, N.K.5
-
6
-
-
84876091299
-
Improving RF field strength and uniformity in a local region by controlling individual transmitting RF phase in a 7T tranceive array coil
-
Kim K-N, Jeong H., Heo P., et al. Improving RF field strength and uniformity in a local region by controlling individual transmitting RF phase in a 7T tranceive array coil. Biomed Eng Lett: 2012; 2 4 223 232
-
(2012)
Biomed Eng Lett
, vol.2
, Issue.4
, pp. 223-232
-
-
Kim, K.-N.1
Jeong, H.2
Heo, P.3
-
7
-
-
24944566857
-
Small animal imaging in drug development
-
DOI 10.2174/138161205774424681
-
Pomper M. G., Lee J. S. Small animal imaging in drug development. Curr Pharm Des: 2005; 11 25 3247 3272 (Pubitemid 41300775)
-
(2005)
Current Pharmaceutical Design
, vol.11
, Issue.25
, pp. 3247-3272
-
-
Pomper, M.G.1
Lee, J.S.2
-
8
-
-
0035103741
-
Medical image registration
-
DOI 10.1088/0031-9155/46/3/201, PII S0031915501968769
-
Hill D. LG, Batchelor P. G., Holden M., Hawkes D. J. Medical image registration. Phys Med Biol: 2001; 46 3 R1 R45 (Pubitemid 32218849)
-
(2001)
Physics in Medicine and Biology
, vol.46
, Issue.3
-
-
Hill, D.L.G.1
Batchelor, P.G.2
Holden, M.3
Hawkes, D.J.4
-
9
-
-
0043237770
-
Image registration methods: A survey
-
Zitová B., Flusser J. Image registration methods: a survey. Image Vis Comput: 2003; 21 977 1000
-
(2003)
Image Vis Comput
, vol.21
, pp. 977-1000
-
-
Zitová, B.1
Flusser, J.2
-
10
-
-
17644371614
-
Development and applications of a software for Functional Image Registration (FIRE)
-
DOI 10.1016/j.cmpb.2004.12.007
-
Lee J. S., Park K. S., Lee D. S., Lee C. W., Chung J. K., Lee M. C. Development and applications of a software for Functional Image Registration (FIRE). Comput Methods Programs Biomed: 2005; 78 2 157 164 (Pubitemid 40558734)
-
(2005)
Computer Methods and Programs in Biomedicine
, vol.78
, Issue.2
, pp. 157-164
-
-
Lee, J.S.1
Park, K.S.2
Lee, D.S.3
Lee, C.W.4
Chung, J.-K.5
Lee, M.C.6
-
11
-
-
84876466220
-
Nonrigid image registration using efficient similarity measure and Levenberg-Marquardt optimization
-
Gaidhane V. H., Hote Y. V., Singh V. Nonrigid image registration using efficient similarity measure and Levenberg-Marquardt optimization. Biomed Eng Lett: 2012; 2 2 118 123
-
(2012)
Biomed Eng Lett
, vol.2
, Issue.2
, pp. 118-123
-
-
Gaidhane, V.H.1
Hote, Y.V.2
Singh, V.3
-
12
-
-
0028711780
-
Investigation of the use of x-ray CT images for attenuation correction in SPECT
-
LaCroix K. J., Tsui B. MW, Hasegawa B. H., Brown J. K. Investigation of the use of x-ray CT images for attenuation correction in SPECT. IEEE Trans Nucl Sci: 1994; 41 2793 2799
-
(1994)
IEEE Trans Nucl Sci
, vol.41
, pp. 2793-2799
-
-
Lacroix, K.J.1
Tsui, B.M.2
Hasegawa, B.H.3
Brown, J.K.4
-
13
-
-
0030216396
-
Attenuation correction of spect using x-ray ct on an emissiontransmission ct system: Myocardial perfusion assessment
-
Blankespoor S. C., Xu X., Kaiki K., et al. Attenuation correction of SPECT using X-ray CT on an emission-transmission CT system: myocardial perfusion assessment. IEEE Trans Nucl Sci: 1996; 43 4 2263 2274 (Pubitemid 126771606)
-
(1996)
IEEE Transactions on Nuclear Science
, vol.43
, Issue.4 PART 1
, pp. 2263-2274
-
-
Blankespoor, S.C.1
Wu, X.2
Kalki, K.3
Brown, J.K.4
Tang, H.R.5
Cann, C.E.6
Hasegawa, B.H.7
-
14
-
-
41549139159
-
Technological Development and Advances in Single-Photon Emission Computed Tomography/Computed Tomography
-
DOI 10.1053/j.semnuclmed.2008.01.001, PII S0001299808000202
-
Seo Y., Mari C., Hasegawa B. H. Technological development and advances in single-photon emission computed tomography/computed tomography. Semin Nucl Med: 2008; 38 3 177 198 (Pubitemid 351466914)
-
(2008)
Seminars in Nuclear Medicine
, vol.38
, Issue.3
, pp. 177-198
-
-
Seo, Y.1
Mari, C.2
Hasegawa, B.H.3
-
15
-
-
0033870513
-
A combined PET/CT scanner for clinical oncology
-
Beyer T., Townsend D. W., Brun T., et al. A combined PET/CT scanner for clinical oncology. J Nucl Med: 2000; 41 8 1369 1379 (Pubitemid 30643379)
-
(2000)
Journal of Nuclear Medicine
, vol.41
, Issue.8
, pp. 1369-1379
-
-
Beyer, T.1
Townsend, D.W.2
Brun, T.3
Kinahan, P.E.4
Charron, M.5
Roddy, R.6
Jerin, J.7
Young, J.8
Byars, L.9
Nutt, R.10
-
16
-
-
44849092884
-
Dual-modality imaging: Combining anatomy and function
-
DOI 10.2967/jnumed.108.051276
-
Townsend D. W. Dual-modality imaging: combining anatomy and function. J Nucl Med: 2008; 49 6 938 955 (Pubitemid 351793435)
-
(2008)
Journal of Nuclear Medicine
, vol.49
, Issue.6
, pp. 938-955
-
-
Townsend, D.W.1
-
17
-
-
46849087258
-
Current trends in PET and combined (PET/CT and PET/MR) systems design
-
Zaidi H., Alavi A. Current trends in PET and combined (PET/CT and PET/MR) systems design. PET Clin: 2007; 2 2 109 123
-
(2007)
PET Clin
, vol.2
, Issue.2
, pp. 109-123
-
-
Zaidi, H.1
Alavi, A.2
-
18
-
-
79954582561
-
Technical advances in current PET and hybrid imaging systems
-
Lee J. S. Technical advances in current PET and hybrid imaging systems. Open Nucl Med J: 2010; 2 192 208
-
(2010)
Open Nucl Med J
, vol.2
, pp. 192-208
-
-
Lee, J.S.1
-
19
-
-
0030801355
-
Simultaneous PET and MR imaging
-
DOI 10.1088/0031-9155/42/10/010, PII S003191559781007X
-
Shao Y., Cherry S. R., Farahani K., et al. Simultaneous PET and MR imaging. Phys Med Biol: 1997; 42 10 1965 1970 (Pubitemid 27448997)
-
(1997)
Physics in Medicine and Biology
, vol.42
, Issue.10
, pp. 1965-1970
-
-
Shao, Y.1
Cherry, S.R.2
Farahani, K.3
Meadors, K.4
Siegel, S.5
Silverman, R.W.6
Marsden, P.K.7
-
20
-
-
33846873900
-
Simultaneous MRI and PET imaging of a rat brain
-
DOI 10.1088/0031-9155/51/24/006, PII S0031915506283106, 006
-
Raylman R. R., Majewski S., Lemieux S. K., et al. Simultaneous MRI and PET imaging of a rat brain. Phys Med Biol: 2006; 51 24 6371 6379 (Pubitemid 46217627)
-
(2006)
Physics in Medicine and Biology
, vol.51
, Issue.24
, pp. 6371-6379
-
-
Raylman, R.R.1
Majewski, S.2
Lemieux, S.K.3
Velan, S.S.4
Kross, B.5
Popov, V.6
Smith, M.F.7
Weisenberger, A.G.8
Zorn, C.9
Marano, G.D.10
-
21
-
-
67651083548
-
Multimodality imaging: Beyond PET/CT and SPECT/CT
-
Cherry S. R. Multimodality imaging: beyond PET/CT and SPECT/CT. Semin Nucl Med: 2009; 39 5 348 353
-
(2009)
Semin Nucl Med
, vol.39
, Issue.5
, pp. 348-353
-
-
Cherry, S.R.1
-
22
-
-
84870464483
-
Is there still a role for SPECT-CT in oncology in the PET-CT era
-
Hicks R. J., Hofman M. S. Is there still a role for SPECT-CT in oncology in the PET-CT era? Nat Rev Clin Oncol: 2012; 9 12 712 720
-
(2012)
Nat Rev Clin Oncol
, vol.9
, Issue.12
, pp. 712-720
-
-
Hicks, R.J.1
Hofman, M.S.2
-
23
-
-
84886644841
-
SPECT-CT: Applications in musculoskeletal radiology
-
Saha S., Burke C., Desai A., Vijayanathan S., Gnanasegaran G. SPECT-CT: applications in musculoskeletal radiology. Br J Radiol: 2013; 86 1031 20120519
-
(2013)
Br J Radiol
, vol.86
, Issue.1031
, pp. 20120519
-
-
Saha, S.1
Burke, C.2
Desai, A.3
Vijayanathan, S.4
Gnanasegaran, G.5
-
24
-
-
84876084161
-
Development of correction schemes for a small field of view gamma camera
-
Hung N. M., Joung J., Lee K., Kim Y. Development of correction schemes for a small field of view gamma camera. Biomed Eng Lett: 2012; 2 4 215 222
-
(2012)
Biomed Eng Lett
, vol.2
, Issue.4
, pp. 215-222
-
-
Hung, N.M.1
Joung, J.2
Lee, K.3
Kim, Y.4
-
26
-
-
36849139664
-
Scintillation camera
-
Anger H. O. Scintillation camera. Rev Sci Instrum: 1957; 29 27 33
-
(1957)
Rev Sci Instrum
, vol.29
, pp. 27-33
-
-
Anger, H.O.1
-
27
-
-
0001288893
-
Scintillation camera with multichannel collimators
-
Anger H. O. Scintillation camera with multichannel collimators. J Nucl Med: 1964; 5 515 531
-
(1964)
J Nucl Med
, vol.5
, pp. 515-531
-
-
Anger, H.O.1
-
28
-
-
52949153354
-
-
In: Wernick M.N. Aarsvold J.N. eds. Emission Tomography: The Fundamentals of PET and SPECT San Diego, CA Elsevier
-
Zeng G. L., Galt J. R., Wernick M. N., Mintzer R. A., Aarsvold J. N. Single-photon emission computed tomography. In: Wernick M. N., Aarsvold J. N., eds. Emission Tomography: The Fundamentals of PET and SPECT. San Diego, CA Elsevier: 2004; 127 152
-
(2004)
Single-photon Emission Computed Tomography
, pp. 127-152
-
-
Zeng, G.L.1
Galt, J.R.2
Wernick, M.N.3
Mintzer, R.A.4
Aarsvold, J.N.5
-
29
-
-
80052073056
-
SPECT detectors: The Anger Camera and beyond
-
Peterson T. E., Furenlid L. R. SPECT detectors: the Anger Camera and beyond. Phys Med Biol: 2011; 56 17 R145 R182
-
(2011)
Phys Med Biol
, vol.56
, Issue.17
-
-
Peterson, T.E.1
Furenlid, L.R.2
-
30
-
-
84898444587
-
-
GE Heathcare White Paper 2010 Accessed on March 18, 2014
-
CZT technology: fundamentals and applications. GE Heathcare White Paper 2010. Available at: http://www3.gehealthcare.com/~/media/Downloads/us/Product/ Categories/Nuclear-Medicine/Cardiac%20Scanners/Discovery-NM570c/ GEHealthcare-Whitepaper-CZT-Technology-20111201.pdf. Accessed on March 18, 2014
-
CZT Technology: Fundamentals and Applications
-
-
-
31
-
-
34547397567
-
Recent technologic advances in nuclear cardiology
-
DOI 10.1016/j.nuclcard.2007.06.003, PII S1071358107002917
-
Patton J. A., Slomka P. J., Germano G., Berman D. S. Recent technologic advances in nuclear cardiology. J Nucl Cardiol: 2007; 14 4 501 513 (Pubitemid 47163564)
-
(2007)
Journal of Nuclear Cardiology
, vol.14
, Issue.4 SPEC. ISS.
, pp. 501-513
-
-
Patton, J.A.1
Slomka, P.J.2
Germano, G.3
Berman, D.S.4
-
32
-
-
67649891804
-
Performance evaluation of D-SPECT: A novel SPECT system for nuclear cardiology
-
Erlandsson K., Kacperski K., van Gramberg D., Hutton B. F. Performance evaluation of D-SPECT: a novel SPECT system for nuclear cardiology. Phys Med Biol: 2009; 54 9 2635 2649
-
(2009)
Phys Med Biol
, vol.54
, Issue.9
, pp. 2635-2649
-
-
Erlandsson, K.1
Kacperski, K.2
Van Gramberg, D.3
Hutton, B.F.4
-
33
-
-
72249112561
-
Novel solid-state-detector dedicated cardiac camera for fast myocardial perfusion imaging: Multicenter comparison with standard dual detector cameras
-
Esteves F. P., Raggi P., Folks R. D., et al. Novel solid-state-detector dedicated cardiac camera for fast myocardial perfusion imaging: multicenter comparison with standard dual detector cameras. J Nucl Cardiol: 2009; 16 6 927 934
-
(2009)
J Nucl Cardiol
, vol.16
, Issue.6
, pp. 927-934
-
-
Esteves, F.P.1
Raggi, P.2
Folks, R.D.3
-
34
-
-
84864032095
-
Advances in SPECT camera software and hardware: Currently available and new on the horizon
-
quiz 585
-
DePuey E. G. Advances in SPECT camera software and hardware: currently available and new on the horizon. J Nucl Cardiol: 2012; 19 3 551 581; quiz 585
-
(2012)
J Nucl Cardiol
, vol.19
, Issue.3
, pp. 551-581
-
-
Depuey, E.G.1
-
35
-
-
79851487935
-
Cardiac dedicated ultrafast SPECT cameras: New designs and clinical implications
-
Garcia E. V., Faber T. L., Esteves F. P. Cardiac dedicated ultrafast SPECT cameras: new designs and clinical implications. J Nucl Med: 2011; 52 2 210 217
-
(2011)
J Nucl Med
, vol.52
, Issue.2
, pp. 210-217
-
-
Garcia, E.V.1
Faber, T.L.2
Esteves, F.P.3
-
36
-
-
33747872173
-
-
In: Zaidi H. ed. Quantitative Analysis of Nuclear Medicine Images New York, NY Springer
-
Frey E., Tsui B. Collimator-detector response compensation in SPECT. In: Zaidi H., ed. Quantitative Analysis of Nuclear Medicine Images. New York, NY Springer: 2006; 141 166
-
(2006)
Collimator-detector Response Compensation in SPECT
, pp. 141-166
-
-
Frey, E.1
Tsui, B.2
-
37
-
-
41849104653
-
PET versus SPECT: Strengths, limitations and challenges
-
DOI 10.1097/MNM.0b013e3282f3a515, PII 0000623120080300000002
-
Rahmim A., Zaidi H. PET versus SPECT: strengths, limitations and challenges. Nucl Med Commun: 2008; 29 3 193 207 (Pubitemid 351499295)
-
(2008)
Nuclear Medicine Communications
, vol.29
, Issue.3
, pp. 193-207
-
-
Rahmim, A.1
Zaidi, H.2
-
39
-
-
78649645686
-
Pediatric 99mTc-MDP bone SPECT with ordered subset expectation maximization iterative reconstruction with isotropic 3D resolution recovery
-
Stansfield E. C., Sheehy N., Zurakowski D., Vija A. H., Fahey F. H., Treves S. T. Pediatric 99mTc-MDP bone SPECT with ordered subset expectation maximization iterative reconstruction with isotropic 3D resolution recovery. Radiology: 2010; 257 3 793 801
-
(2010)
Radiology
, vol.257
, Issue.3
, pp. 793-801
-
-
Stansfield, E.C.1
Sheehy, N.2
Zurakowski, D.3
Vija, A.H.4
Fahey, F.H.5
Treves, S.T.6
-
40
-
-
84872047523
-
An evidence-based review of quantitative SPECT imaging and potential clinical applications
-
Bailey D. L., Willowson K. P. An evidence-based review of quantitative SPECT imaging and potential clinical applications. J Nucl Med: 2013; 54 1 83 89
-
(2013)
J Nucl Med
, vol.54
, Issue.1
, pp. 83-89
-
-
Bailey, D.L.1
Willowson, K.P.2
-
41
-
-
0031847790
-
Transmission scanning in emission tomography
-
DOI 10.1007/s002590050282
-
Bailey D. L. Transmission scanning in emission tomography. Eur J Nucl Med: 1998; 25 7 774 787 (Pubitemid 28377042)
-
(1998)
European Journal of Nuclear Medicine
, vol.25
, Issue.7
, pp. 774-787
-
-
Bailey, D.L.1
-
42
-
-
0037315301
-
Determination of the attenuation map in emission tomography
-
Zaidi H., Hasegawa B. Determination of the attenuation map in emission tomography. J Nucl Med: 2003; 44 2 291 315
-
(2003)
J Nucl Med
, vol.44
, Issue.2
, pp. 291-315
-
-
Zaidi, H.1
Hasegawa, B.2
-
43
-
-
84898407926
-
-
Siemens Medical Solutions USA Inc. White Paper 2013 Accessed on: March 18, 2014
-
Vija H. Introduction to xSPECT technology: evolving multi-modal SPECT to become context-based and quantitative. Siemens Medical Solutions USA Inc. White Paper 2013. Available at: http://www.healthcare.siemens.com/siemens-hwem-hwen- ssxa-websites-context-root/wcm/idc/groups/public/@global/@imaging/@molecular/ documents/download/mdax/ote3/~edisp/xspect-technical-white-paper-00957532.pdf. Accessed on: March 18, 2014
-
Introduction to XSPECT Technology: Evolving Multi-modal SPECT to Become Context-based and Quantitative
-
-
Vija, H.1
-
44
-
-
70349560881
-
Musculoskeletal pitfalls in 18F-FDG PET/CT: Pictorial review
-
(3, Suppl): quiz S26-S30
-
Costelloe C. M., Murphy W. A. Jr, Chasen B. A. Musculoskeletal pitfalls in 18F-FDG PET/CT: pictorial review. AJR Am J Roentgenol: 2009; 193 (3, Suppl): WS1 WS13; quiz S26-S30
-
(2009)
AJR Am J Roentgenol
, vol.193
-
-
Costelloe, C.M.1
Murphy Jr., W.A.2
Chasen, B.A.3
-
45
-
-
78650307602
-
PET/CT in primary musculoskeletal tumours: A step forward
-
Lakkaraju A., Patel C. N., Bradley K. M., Scarsbrook A. F. PET/CT in primary musculoskeletal tumours: a step forward. Eur Radiol: 2010; 20 12 2959 2972
-
(2010)
Eur Radiol
, vol.20
, Issue.12
, pp. 2959-2972
-
-
Lakkaraju, A.1
Patel, C.N.2
Bradley, K.M.3
Scarsbrook, A.F.4
-
46
-
-
84885157313
-
Musculoskeletal imaging using fluoride PET
-
Fischer D. R. Musculoskeletal imaging using fluoride PET. Semin Nucl Med: 2013; 43 6 427 433
-
(2013)
Semin Nucl Med
, vol.43
, Issue.6
, pp. 427-433
-
-
Fischer, D.R.1
-
47
-
-
84874196114
-
Usefulness of 18F-fluoride PET/CT in breast cancer patients with osteosclerotic bone metastases
-
Yoon S. H., Kim K. S., Kang S. Y., et al. Usefulness of 18F-fluoride PET/CT in breast cancer patients with osteosclerotic bone metastases. Nucl Med Mol Imaging: 2013; 47 1 27 35
-
(2013)
Nucl Med Mol Imaging
, vol.47
, Issue.1
, pp. 27-35
-
-
Yoon, S.H.1
Kim, K.S.2
Kang, S.Y.3
-
48
-
-
37649024143
-
Skeletal PET with 18F-fluoride: Applying new technology to an old tracer
-
Grant F. D., Fahey F. H., Packard A. B., Davis R. T., Alavi A., Treves S. T. Skeletal PET with 18F-fluoride: applying new technology to an old tracer. J Nucl Med: 2008; 49 1 68 78
-
(2008)
J Nucl Med
, vol.49
, Issue.1
, pp. 68-78
-
-
Grant, F.D.1
Fahey, F.H.2
Packard, A.B.3
Davis, R.T.4
Alavi, A.5
Treves, S.T.6
-
50
-
-
51849109068
-
Recent developments in PET detector technology
-
Lewellen T. K. Recent developments in PET detector technology. Phys Med Biol: 2008; 53 17 R287 R317
-
(2008)
Phys Med Biol
, vol.53
, Issue.17
-
-
Lewellen, T.K.1
-
51
-
-
84862895366
-
Positron emission tomography (PET) detectors with depth-of-interaction (DOI) capability
-
Ito M., Hong S. J., Lee J. S. Positron emission tomography (PET) detectors with depth-of-interaction (DOI) capability. Biomed Eng Lett: 2011; 1 2 70 81
-
(2011)
Biomed Eng Lett
, vol.1
, Issue.2
, pp. 70-81
-
-
Ito, M.1
Hong, S.J.2
Lee, J.S.3
-
52
-
-
79958037890
-
Focus on time-of-flight PET: The benefits of improved time resolution
-
Conti M. Focus on time-of-flight PET: the benefits of improved time resolution. Eur J Nucl Med Mol Imaging: 2011; 38 6 1147 1157
-
(2011)
Eur J Nucl Med Mol Imaging
, vol.38
, Issue.6
, pp. 1147-1157
-
-
Conti, M.1
-
53
-
-
84878952408
-
Resolution modeling in PET imaging: Theory, practice, benefits, and pitfalls
-
Rahmim A., Qi J., Sossi V. Resolution modeling in PET imaging: theory, practice, benefits, and pitfalls. Med Phys: 2013; 40 6 064301
-
(2013)
Med Phys
, vol.40
, Issue.6
, pp. 064301
-
-
Rahmim, A.1
Qi, J.2
Sossi, V.3
-
54
-
-
23844543772
-
Modeling and incorporation of system response functions in 3D whole body PET
-
M10-228, 2004 IEEE Nuclear Science Symposium Conference Record
-
Alessio A. M., Kinahan P. E., Lewellen T. K. Modeling and incorporation of system response functions in 3D whole body PET. IEEE Nucl Sci Symp Conf Rec: 2004; 6 3992 3996 (Pubitemid 41147813)
-
(2004)
IEEE Nuclear Science Symposium Conference Record
, vol.6
, pp. 3992-3996
-
-
Alessio, A.M.1
Kinahan, P.E.2
Lewellen, T.K.3
-
55
-
-
68249147411
-
Impact of time-of-flight on PET tumor detection
-
Kadrmas D. J., Casey M. E., Conti M., Jakoby B. W., Lois C., Townsend D. W. Impact of time-of-flight on PET tumor detection. J Nucl Med: 2009; 50 8 1315 1323
-
(2009)
J Nucl Med
, vol.50
, Issue.8
, pp. 1315-1323
-
-
Kadrmas, D.J.1
Casey, M.E.2
Conti, M.3
Jakoby, B.W.4
Lois, C.5
Townsend, D.W.6
-
56
-
-
84868314165
-
Improvement in PET/CT image quality with a combination of point-spread function and time-of-flight in relation to reconstruction parameters
-
Akamatsu G., Ishikawa K., Mitsumoto K., et al. Improvement in PET/CT image quality with a combination of point-spread function and time-of-flight in relation to reconstruction parameters. J Nucl Med: 2012; 53 11 1716 1722
-
(2012)
J Nucl Med
, vol.53
, Issue.11
, pp. 1716-1722
-
-
Akamatsu, G.1
Ishikawa, K.2
Mitsumoto, K.3
-
57
-
-
84878946487
-
Clinical impact of time-of-flight and point response modeling in PET reconstructions: A lesion detection study
-
Schaefferkoetter J., Casey M., Townsend D., El Fakhri G. Clinical impact of time-of-flight and point response modeling in PET reconstructions: a lesion detection study. Phys Med Biol: 2013; 58 5 1465 1478
-
(2013)
Phys Med Biol
, vol.58
, Issue.5
, pp. 1465-1478
-
-
Schaefferkoetter, J.1
Casey, M.2
Townsend, D.3
El Fakhri, G.4
-
58
-
-
84858637982
-
Estimating effective model kernel widths for PSF reconstruction in PET
-
Watson C. C. Estimating effective model kernel widths for PSF reconstruction in PET. IEEE Nucl Sci Symp Conf Rec: 2011; 2368 2374
-
(2011)
IEEE Nucl Sci Symp Conf Rec
, pp. 2368-2374
-
-
Watson, C.C.1
-
59
-
-
84898480295
-
-
National Council on Radiation Protection & Measurements (NCRP) Report no. 160: Ionizing radiation exposure of the population of the United States (2009) Accessed January 9, 2014
-
National Council on Radiation Protection & Measurements (NCRP) Report no. 160: Ionizing radiation exposure of the population of the United States (2009). Available at: http://www.ncrppublications.org/Reports/160. Accessed January 9, 2014
-
-
-
-
60
-
-
38849164794
-
Prior image constrained compressed sensing (PICCS): A method to accurately reconstruct dynamic CT images from highly undersampled projection data sets
-
DOI 10.1118/1.2836423
-
Chen G. H., Tang J., Leng S. Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets. Med Phys: 2008; 35 2 660 663 (Pubitemid 351190885)
-
(2008)
Medical Physics
, vol.35
, Issue.2
, pp. 660-663
-
-
Chen, G.-H.1
Tang, J.2
Leng, S.3
-
61
-
-
51849124226
-
Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization
-
Sidky E. Y., Pan X. Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization. Phys Med Biol: 2008; 53 17 4777 4807
-
(2008)
Phys Med Biol
, vol.53
, Issue.17
, pp. 4777-4807
-
-
Sidky, E.Y.1
Pan, X.2
-
62
-
-
0034919923
-
Ordered subset reconstruction for x-ray CT
-
DOI 10.1088/0031-9155/46/7/307
-
Beekma F. J., Kamphuis C. Ordered subset reconstruction for x-ray CT. Phys Med Biol: 2001; 46 7 1835 1844 (Pubitemid 32677542)
-
(2001)
Physics in Medicine and Biology
, vol.46
, Issue.7
, pp. 1835-1844
-
-
Beekman, F.J.1
Kamphuis, C.2
-
63
-
-
33645301494
-
Evaluation of accelerated iterative x-ray CT image reconstruction using floating point graphics hardware
-
Kole J. S., Beekman F. J. Evaluation of accelerated iterative x-ray CT image reconstruction using floating point graphics hardware. Phys Med Biol: 2006; 51 4 875 889
-
(2006)
Phys Med Biol
, vol.51
, Issue.4
, pp. 875-889
-
-
Kole, J.S.1
Beekman, F.J.2
-
64
-
-
34748901307
-
GPU-based streaming architectures for fast cone-beam CT image reconstruction and demons deformable registration
-
DOI 10.1088/0031-9155/52/19/003, PII S0031915507526217, 003
-
Sharp G. C., Kandasamy N., Singh H., Folkert M. GPU-based streaming architectures for fast cone-beam CT image reconstruction and demons deformable registration. Phys Med Biol: 2007; 52 19 5771 5783 (Pubitemid 47485412)
-
(2007)
Physics in Medicine and Biology
, vol.52
, Issue.19
, pp. 5771-5783
-
-
Sharp, G.C.1
Kandasamy, N.2
Singh, H.3
Folkert, M.4
-
65
-
-
74749087439
-
Innovations in CT dose reduction strategy: Application of the adaptive statistical iterative reconstruction algorithm
-
Silva A. C., Lawder H. J., Hara A., Kujak J., Pavlicek W. Innovations in CT dose reduction strategy: application of the adaptive statistical iterative reconstruction algorithm. AJR Am J Roentgenol: 2010; 194 1 191 199
-
(2010)
AJR Am J Roentgenol
, vol.194
, Issue.1
, pp. 191-199
-
-
Silva, A.C.1
Lawder, H.J.2
Hara, A.3
Kujak, J.4
Pavlicek, W.5
-
66
-
-
33645562681
-
CT dose reduction and dose management tools: Overview of available options
-
DOI 10.1148/rg.262055138
-
McCollough C. H., Bruesewitz M. R., Kofler J. M. Jr. CT dose reduction and dose management tools: overview of available options. Radiographics: 2006; 26 2 503 512 (Pubitemid 43515321)
-
(2006)
Radiographics
, vol.26
, Issue.2
, pp. 503-512
-
-
McCollough, C.H.1
Bruesewitz, M.R.2
Kofler Jr., J.M.3
-
67
-
-
84930353395
-
-
In: Kim E.E. Lee M.C. Inoue T. Wong W.-H. eds. Clinical PET and PET/CT: Principles and Applications New York, NY Springer
-
Lee J. S., Kang K. W. PET/MRI. In: Kim E. E., Lee M. C., Inoue T., Wong W-H., eds. Clinical PET and PET/CT: Principles and Applications. New York, NY Springer: 2013; 373 390
-
(2013)
PET/MRI
, pp. 373-390
-
-
Lee, J.S.1
Kang, K.W.2
-
68
-
-
41549089557
-
Positron Emission Tomography/Magnetic Resonance Imaging: The Next Generation of Multimodality Imaging?
-
DOI 10.1053/j.semnuclmed.2008.02.001, PII S000129980800024X
-
Pichler B. J., Wehrl H. F., Kolb A., Judenhofer M. S. Positron emission tomography/magnetic resonance imaging: the next generation of multimodality imaging? Semin Nucl Med: 2008; 38 3 199 208 (Pubitemid 351466918)
-
(2008)
Seminars in Nuclear Medicine
, vol.38
, Issue.3
, pp. 199-208
-
-
Pichler, B.J.1
Wehrl, H.F.2
Kolb, A.3
Judenhofer, M.S.4
-
69
-
-
79955416013
-
Design and performance evaluation of a whole-body Ingenuity TF PET-MRI system
-
Zaidi H., Ojha N., Morich M., et al. Design and performance evaluation of a whole-body Ingenuity TF PET-MRI system. Phys Med Biol: 2011; 56 10 3091 3106
-
(2011)
Phys Med Biol
, vol.56
, Issue.10
, pp. 3091-3106
-
-
Zaidi, H.1
Ojha, N.2
Morich, M.3
-
70
-
-
34247230296
-
Performance of Philips Gemini TF PET/CT scanner with special consideration for its time-of-flight imaging capabilities
-
Surti S., Kuhn A., Werner M. E., Perkins A. E., Kolthammer J., Karp J. S. Performance of Philips Gemini TF PET/CT scanner with special consideration for its time-of-flight imaging capabilities. J Nucl Med: 2007; 48 3 471 480 (Pubitemid 47604933)
-
(2007)
Journal of Nuclear Medicine
, vol.48
, Issue.3
, pp. 471-480
-
-
Surti, S.1
Kuhn, A.2
Werner, M.E.3
Perkins, A.E.4
Kolthammer, J.5
Karp, J.S.6
-
71
-
-
34247199659
-
Simultaneous acquisition of multislice PET and MR images: Initial results with a MR-compatible PET scanner
-
Catana C., Wu Y., Judenhofer M. S., Qi J., Pichler B. J., Cherry S. R. Simultaneous acquisition of multislice PET and MR images: initial results with a MR-compatible PET scanner. J Nucl Med: 2006; 47 12 1968 1976 (Pubitemid 47544984)
-
(2006)
Journal of Nuclear Medicine
, vol.47
, Issue.12
, pp. 1968-1976
-
-
Catana, C.1
Wu, Y.2
Judenhofer, M.S.3
Qi, J.4
Pichler, B.J.5
Cherry, S.R.6
-
72
-
-
33745111311
-
Performance test of an LSO-APD detector in a 7-T MRI scanner for simultaneous PET/MRI
-
Pichler B. J., Judenhofer M. S., Catana C., et al. Performance test of an LSO-APD detector in a 7-T MRI scanner for simultaneous PET/MRI. J Nucl Med: 2006; 47 4 639 647 (Pubitemid 46768465)
-
(2006)
Journal of Nuclear Medicine
, vol.47
, Issue.4
, pp. 639-647
-
-
Pichler, B.J.1
Judenhofer, M.S.2
Catana, C.3
Walton, J.H.4
Kneilling, M.5
Nutt, R.E.6
Siegel, S.B.7
Claussen, C.D.8
Cherry, S.R.9
-
73
-
-
51549120220
-
Simultaneous MR/PET imaging of the human brain: Feasibility study
-
Schlemmer H. P., Pichler B. J., Schmand M., et al. Simultaneous MR/PET imaging of the human brain: feasibility study. Radiology: 2008; 248 3 1028 1035
-
(2008)
Radiology
, vol.248
, Issue.3
, pp. 1028-1035
-
-
Schlemmer, H.P.1
Pichler, B.J.2
Schmand, M.3
-
74
-
-
83755161889
-
Performance measurements of the Siemens mMR integrated whole-body PET/MR scanner
-
Delso G., Fürst S., Jakoby B., et al. Performance measurements of the Siemens mMR integrated whole-body PET/MR scanner. J Nucl Med: 2011; 52 12 1914 1922
-
(2011)
J Nucl Med
, vol.52
, Issue.12
, pp. 1914-1922
-
-
Delso, G.1
Fürst, S.2
Jakoby, B.3
-
75
-
-
84871751912
-
-
In: Iniewski K. ed. Electronic Circuits for Radiation Detection Boca Raton, FL CRC Press
-
Lee J. S., Hong S. J. Geiger-mode avalanche photodiodes for PET/MRI. In: Iniewski K., ed. Electronic Circuits for Radiation Detection. Boca Raton, FL CRC Press: 2010; 179 200
-
(2010)
Geiger-mode Avalanche Photodiodes for PET/MRI
, pp. 179-200
-
-
Lee, J.S.1
Hong, S.J.2
-
76
-
-
79954421803
-
Application of silicon photomultipliers to positron emission tomography
-
Roncali E., Cherry S. R. Application of silicon photomultipliers to positron emission tomography. Ann Biomed Eng: 2011; 39 4 1358 1377
-
(2011)
Ann Biomed Eng
, vol.39
, Issue.4
, pp. 1358-1377
-
-
Roncali, E.1
Cherry, S.R.2
-
77
-
-
45849123920
-
An investigation into the use of Geiger-mode solid-state photomultipliers for simultaneous PET and MRI acquisition
-
Hong S. J., Song I. C., Ito M., et al. An investigation into the use of Geiger-mode solid-state photomultipliers for simultaneous PET and MRI acquisition. IEEE Trans Nucl Sci: 2008; 55 3 882 888
-
(2008)
IEEE Trans Nucl Sci
, vol.55
, Issue.3
, pp. 882-888
-
-
Hong, S.J.1
Song, I.C.2
Ito, M.3
-
78
-
-
78249266285
-
Development of a Si-PM-based high-resolution PET system for small animals
-
Yamamoto S., Imaizumi M., Watabe T., et al. Development of a Si-PM-based high-resolution PET system for small animals. Phys Med Biol: 2010; 55 19 5817 5831
-
(2010)
Phys Med Biol
, vol.55
, Issue.19
, pp. 5817-5831
-
-
Yamamoto, S.1
Imaizumi, M.2
Watabe, T.3
-
79
-
-
79954611852
-
Development of small-animal PET prototype using silicon photomultiplier (SiPM): Initial results of phantom and animal imaging studies
-
Kwon S. I., Lee J. S., Yoon H. S., et al. Development of small-animal PET prototype using silicon photomultiplier (SiPM): initial results of phantom and animal imaging studies. J Nucl Med: 2011; 52 4 572 579
-
(2011)
J Nucl Med
, vol.52
, Issue.4
, pp. 572-579
-
-
Kwon, S.I.1
Lee, J.S.2
Yoon, H.S.3
-
80
-
-
80054817186
-
A SiPM-based isotropic-3D PET detector X'tal cube with a three-dimensional array of 1 mm(3) crystals
-
Yamaya T., Mitsuhashi T., Matsumoto T., et al. A SiPM-based isotropic-3D PET detector X'tal cube with a three-dimensional array of 1 mm(3) crystals. Phys Med Biol: 2011; 56 21 6793 6807
-
(2011)
Phys Med Biol
, vol.56
, Issue.21
, pp. 6793-6807
-
-
Yamaya, T.1
Mitsuhashi, T.2
Matsumoto, T.3
-
81
-
-
84870773520
-
Development of a front-end analog circuit for multi-channel SiPM readout and performance verification for various PET detector designs
-
Ko G. B., Yoon H. S., Kwon S. I., et al. Development of a front-end analog circuit for multi-channel SiPM readout and performance verification for various PET detector designs. Nucl Instr Meth A: 2013; 703 38 44
-
(2013)
Nucl Instr Meth A
, vol.703
, pp. 38-44
-
-
Ko, G.B.1
Yoon, H.S.2
Kwon, S.I.3
-
82
-
-
84859416678
-
Initial results of simultaneous PET/MRI experiments with an MRI-compatible silicon photomultiplier PET scanner
-
Yoon H. S., Ko G. B., Kwon S. I., et al. Initial results of simultaneous PET/MRI experiments with an MRI-compatible silicon photomultiplier PET scanner. J Nucl Med: 2012; 53 4 608 614
-
(2012)
J Nucl Med
, vol.53
, Issue.4
, pp. 608-614
-
-
Yoon, H.S.1
Ko, G.B.2
Kwon, S.I.3
-
83
-
-
84887198253
-
Prototype time-of-flight PET ring integrated with a 3T MRI system for simultaneous whole-body PET/MR imaging
-
02
-
Levin C., Glover G., Deller T., McDaniel D., Peterson W., Maramraju S. H. Prototype time-of-flight PET ring integrated with a 3T MRI system for simultaneous whole-body PET/MR imaging. J Nucl Med: 2013; 54 02 148
-
(2013)
J Nucl Med
, vol.54
, pp. 148
-
-
Levin, C.1
Glover, G.2
Deller, T.3
McDaniel, D.4
Peterson, W.5
Maramraju, S.H.6
-
84
-
-
0036093165
-
PET attenuation coefficients from CT images: Experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients
-
DOI 10.1007/s00259-002-0796-3
-
Burger C., Goerres G., Schoenes S., Buck A., Lonn A. H., Von Schulthess G. K. PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients. Eur J Nucl Med Mol Imaging: 2002; 29 7 922 927 (Pubitemid 34671298)
-
(2002)
European Journal of Nuclear Medicine
, vol.29
, Issue.7
, pp. 922-927
-
-
Burger, C.1
Goerres, G.2
Schoenes, S.3
Buck, A.4
Lonn, A.5
Von Schulthess, G.6
-
85
-
-
0037811001
-
X-ray-based attenuation correction for positron emission tomography/computed tomography scanners
-
DOI 10.1053/snuc.2003.127307
-
Kinahan P. E., Hasegawa B. H., Beyer T. X-ray-based attenuation correction for positron emission tomography/computed tomography scanners. Semin Nucl Med: 2003; 33 3 166 179 (Pubitemid 36859496)
-
(2003)
Seminars in Nuclear Medicine
, vol.33
, Issue.3
, pp. 166-179
-
-
Kinahan, P.E.1
Hasegawa, B.H.2
Beyer, T.3
-
86
-
-
33645510085
-
Method for transforming CT images for attenuation correction in PET/CT imaging
-
Carney J. P., Townsend D. W., Rappoport V., Bendriem B. Method for transforming CT images for attenuation correction in PET/CT imaging. Med Phys: 2006; 33 4 976 983
-
(2006)
Med Phys
, vol.33
, Issue.4
, pp. 976-983
-
-
Carney, J.P.1
Townsend, D.W.2
Rappoport, V.3
Bendriem, B.4
-
87
-
-
57349155316
-
MRI-based attenuation correction for PET/MRI: A novel approach combining pattern recognition and atlas registration
-
Hofmann M., Steinke F., Scheel V., et al. MRI-based attenuation correction for PET/MRI: a novel approach combining pattern recognition and atlas registration. J Nucl Med: 2008; 49 11 1875 1883
-
(2008)
J Nucl Med
, vol.49
, Issue.11
, pp. 1875-1883
-
-
Hofmann, M.1
Steinke, F.2
Scheel, V.3
-
88
-
-
77952358732
-
MR-based attenuation correction for hybrid PET-MR brain imaging systems using deformable image registration
-
Schreibmann E., Nye J. A., Schuster D. M., Martin D. R., Votaw J., Fox T. MR-based attenuation correction for hybrid PET-MR brain imaging systems using deformable image registration. Med Phys: 2010; 37 5 2101 2109
-
(2010)
Med Phys
, vol.37
, Issue.5
, pp. 2101-2109
-
-
Schreibmann, E.1
Nye, J.A.2
Schuster, D.M.3
Martin, D.R.4
Votaw, J.5
Fox, T.6
-
89
-
-
77956679334
-
Feasibility of template-guided attenuation correction in cat brain PET imaging
-
Kim J. S., Lee J. S., Park M. H., et al. Feasibility of template-guided attenuation correction in cat brain PET imaging. Mol Imaging Biol: 2010; 12 3 250 258
-
(2010)
Mol Imaging Biol
, vol.12
, Issue.3
, pp. 250-258
-
-
Kim, J.S.1
Lee, J.S.2
Park, M.H.3
-
90
-
-
79960336732
-
Attenuation correction methods suitable for brain imaging with a PET/MRI scanner: A comparison of tissue atlas and template attenuation map approaches
-
Malone I. B., Ansorge R. E., Williams G. B., Nestor P. J., Carpenter T. A., Fryer T. D. Attenuation correction methods suitable for brain imaging with a PET/MRI scanner: a comparison of tissue atlas and template attenuation map approaches. J Nucl Med: 2011; 52 7 1142 1149
-
(2011)
J Nucl Med
, vol.52
, Issue.7
, pp. 1142-1149
-
-
Malone, I.B.1
Ansorge, R.E.2
Williams, G.B.3
Nestor, P.J.4
Carpenter, T.A.5
Fryer, T.D.6
-
91
-
-
79551523276
-
Automatic, three-segment, MR-based attenuation correction for whole-body PET/MR data
-
Schulz V., Torres-Espallardo I., Renisch S., et al. Automatic, three-segment, MR-based attenuation correction for whole-body PET/MR data. Eur J Nucl Med Mol Imaging: 2011; 38 1 138 152
-
(2011)
Eur J Nucl Med Mol Imaging
, vol.38
, Issue.1
, pp. 138-152
-
-
Schulz, V.1
Torres-Espallardo, I.2
Renisch, S.3
-
92
-
-
63849338624
-
Tissue classification as a potential approach for attenuation correction in whole-body PET/MRI: Evaluation with PET/CT data
-
Martinez-Möller A., Souvatzoglou M., Delso G., et al. Tissue classification as a potential approach for attenuation correction in whole-body PET/MRI: evaluation with PET/CT data. J Nucl Med: 2009; 50 4 520 526
-
(2009)
J Nucl Med
, vol.50
, Issue.4
, pp. 520-526
-
-
Martinez-Möller, A.1
Souvatzoglou, M.2
Delso, G.3
-
93
-
-
60549086399
-
Towards quantitative PET/MRI: A review of MR-based attenuation correction techniques
-
01
-
Hofmann M., Pichler B., Schölkopf B., Beyer T. Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques. Eur J Nucl Med Mol Imaging: 2009; 36 01 S93 S104
-
(2009)
Eur J Nucl Med Mol Imaging
, vol.36
-
-
Hofmann, M.1
Pichler, B.2
Schölkopf, B.3
Beyer, T.4
-
94
-
-
79959534469
-
CT substitute derived from MRI sequences with ultrashort echo time
-
Johansson A., Karlsson M., Nyholm T. CT substitute derived from MRI sequences with ultrashort echo time. Med Phys: 2011; 38 5 2708 2714
-
(2011)
Med Phys
, vol.38
, Issue.5
, pp. 2708-2714
-
-
Johansson, A.1
Karlsson, M.2
Nyholm, T.3
-
95
-
-
77957038794
-
Toward implementing an MRI-based PET attenuation-correction method for neurologic studies on the MR-PET brain prototype
-
Catana C., van der Kouwe A., Benner T., et al. Toward implementing an MRI-based PET attenuation-correction method for neurologic studies on the MR-PET brain prototype. J Nucl Med: 2010; 51 9 1431 1438
-
(2010)
J Nucl Med
, vol.51
, Issue.9
, pp. 1431-1438
-
-
Catana, C.1
Van Der Kouwe, A.2
Benner, T.3
-
96
-
-
77952302436
-
MRI-based attenuation correction for PET/MRI using ultrashort echo time sequences
-
Keereman V., Fierens Y., Broux T., De Deene Y., Lonneux M., Vandenberghe S. MRI-based attenuation correction for PET/MRI using ultrashort echo time sequences. J Nucl Med: 2010; 51 5 812 818
-
(2010)
J Nucl Med
, vol.51
, Issue.5
, pp. 812-818
-
-
Keereman, V.1
Fierens, Y.2
Broux, T.3
De Deene, Y.4
Lonneux, M.5
Vandenberghe, S.6
-
97
-
-
84870329352
-
Comparison of segmentation-based attenuation correction methods for PET/MRI: Evaluation of bone and liver standardized uptake value with oncologic PET/CT data
-
Kim J. H., Lee J. S., Song I. C., Lee D. S. Comparison of segmentation-based attenuation correction methods for PET/MRI: evaluation of bone and liver standardized uptake value with oncologic PET/CT data. J Nucl Med: 2012; 53 12 1878 1882
-
(2012)
J Nucl Med
, vol.53
, Issue.12
, pp. 1878-1882
-
-
Kim, J.H.1
Lee, J.S.2
Song, I.C.3
Lee, D.S.4
-
98
-
-
84898470380
-
18F-FDG PET/MR in comparison to PET/CT for evaluation of malignant bone lesions
-
18F-FDG PET/MR in comparison to PET/CT for evaluation of malignant bone lesions. J Nucl Med: 2013
-
(2013)
J Nucl Med
-
-
Eiber, M.1
Takei, T.2
Souvatzoglou, M.3
-
99
-
-
84861883596
-
Variable lung density consideration in attenuation correction of whole-body PET/MRI
-
Marshall H. R., Prato F. S., Deans L., Théberge J., Thompson R. T., Stodilka R. Z. Variable lung density consideration in attenuation correction of whole-body PET/MRI. J Nucl Med: 2012; 53 6 977 984
-
(2012)
J Nucl Med
, vol.53
, Issue.6
, pp. 977-984
-
-
Marshall, H.R.1
Prato, F.S.2
Deans, L.3
Théberge, J.4
Thompson, R.T.5
Stodilka, R.Z.6
|