메뉴 건너뛰기




Volumn 1, Issue 2, 2011, Pages 70-81

Positron emission tomography (PET) detectors with depth-of- interaction (DOI) capability

Author keywords

Depth of interaction (DOI); Dual ended readout; Multi layer detector; Positron emission tomography (PET); Single ended readout

Indexed keywords


EID: 84862895366     PISSN: 20939868     EISSN: 2093985X     Source Type: Journal    
DOI: 10.1007/s13534-011-0019-6     Document Type: Review
Times cited : (153)

References (76)
  • 1
    • 0034798179 scopus 로고    scopus 로고
    • PET as a potential tool for imaging molecular mechanisms of oncology in man
    • Price P. PET as a potential tool for imaging molecular mechanisms of oncology in man. Trends Mol Med. 2001; 7(10): 442-426.
    • (2001) Trends Mol Med , vol.7 , Issue.10 , pp. 426-442
    • Price, P.1
  • 2
    • 3042789514 scopus 로고    scopus 로고
    • Experiment assessment of mass effects in the rat: implications for small animal PET imaging
    • Jagoda EM, Vaquero JJ, Seidel J, Green MV, Eckelman WC. Experiment assessment of mass effects in the rat: implications for small animal PET imaging. Nucl Med Biol. 2004; 31(6): 771-779.
    • (2004) Nucl Med Biol , vol.31 , Issue.6 , pp. 771-779
    • Jagoda, E.M.1    Vaquero, J.J.2    Seidel, J.3    Green, M.V.4    Eckelman, W.C.5
  • 4
    • 0012114277 scopus 로고    scopus 로고
    • Trends in PET imaging
    • Moses WW. Trends in PET imaging. Nucl Instrum Meth A. 2001; 471: 209-214.
    • (2001) Nucl Instrum Meth A , vol.471 , pp. 209-214
    • Moses, W.W.1
  • 7
    • 0032136644 scopus 로고    scopus 로고
    • Parallax correction in PET using depth of interaction information
    • MacDonald LR, Dahlbom M. Parallax correction in PET using depth of interaction information. IEEE T Nucl Sci. 1998; 45(4): 2232-2237.
    • (1998) IEEE T Nucl Sci , vol.45 , Issue.4 , pp. 2232-2237
    • Macdonald, L.R.1    Dahlbom, M.2
  • 8
    • 79954582561 scopus 로고    scopus 로고
    • Technical advances in current PET and hybrid imaging systems
    • Lee JS. Technical advances in current PET and hybrid imaging systems. Open Nucl Med J. 2010; 2: 192-208.
    • (2010) Open Nucl Med J , vol.2 , pp. 192-208
    • Lee, J.S.1
  • 10
    • 79551693751 scopus 로고    scopus 로고
    • Investigating the temporal resolution limits of scintillation detection from pixelated elements: comparison between experiment and simulation
    • Spanoudaki VCh, Levin CS. Investigating the temporal resolution limits of scintillation detection from pixelated elements: comparison between experiment and simulation. Phys Med Biol. 2011; 56(3): 735-756.
    • (2011) Phys Med Biol , vol.56 , Issue.3 , pp. 735-756
    • Spanoudaki, V.1    Levin, C.S.2
  • 11
    • 45749106305 scopus 로고    scopus 로고
    • Design considerations for a limited angle, dedicated breast, TOF PET scanner
    • Surti S, Karp JS. Design considerations for a limited angle, dedicated breast, TOF PET scanner. Phys Med Biol. 2008; 53(11): 2911-2921.
    • (2008) Phys Med Biol , vol.53 , Issue.11 , pp. 2911-2921
    • Surti, S.1    Karp, J.S.2
  • 12
    • 51849109068 scopus 로고    scopus 로고
    • Recent developments in PET detector technology
    • Lewellen TK. Recent developments in PET detector technology. Phys Med Biol. 2008; 53: R287-R317.
    • (2008) Phys Med Biol , vol.53
    • Lewellen, T.K.1
  • 13
    • 70350142876 scopus 로고    scopus 로고
    • Monte Carlo simulation study on the time resolution of a PMT-quadrant-sharing LSO detector block for time-of-flight PET
    • Liu S, Li H, Zhang Y, Ramirez RA, Baghaei H, An S, Wang C, Liu J, Wong WH. Monte Carlo simulation study on the time resolution of a PMT-quadrant-sharing LSO detector block for time-of-flight PET. IEEE T Nucl Sci. 2009; 56(5): 2614-2620.
    • (2009) IEEE T Nucl Sci , vol.56 , Issue.5 , pp. 2614-2620
    • Liu, S.1    Li, H.2    Zhang, Y.3    Ramirez, R.A.4    Baghaei, H.5    An, S.6    Wang, C.7    Liu, J.8    Wong, W.H.9
  • 14
    • 0033337104 scopus 로고    scopus 로고
    • Prospects for time-of-flight PET using LSO scintillator
    • Moses WW, Derenzo SE. Prospects for time-of-flight PET using LSO scintillator. IEEE T Nucl Sci. 1999; 46(3): 474-477.
    • (1999) IEEE T Nucl Sci , vol.46 , Issue.3 , pp. 474-477
    • Moses, W.W.1    Derenzo, S.E.2
  • 15
    • 34548503918 scopus 로고    scopus 로고
    • Recent advances and future advances in time-offlight PET
    • Moses WW. Recent advances and future advances in time-offlight PET. Nucl Instrum Meth A. 2007; 580(2): 919-924.
    • (2007) Nucl Instrum Meth A , vol.580 , Issue.2 , pp. 919-924
    • Moses, W.W.1
  • 16
    • 0021575667 scopus 로고
    • A study of light collection efficiency in scintillation detectors
    • Xiaobuang Y. A study of light collection efficiency in scintillation detectors. Nucl Instrum Meth A. 1984; 228(1): 101-104.
    • (1984) Nucl Instrum Meth A , vol.228 , Issue.1 , pp. 101-104
    • Xiaobuang, Y.1
  • 17
    • 33746335330 scopus 로고    scopus 로고
    • Recent timing performance of Hi-Rez detector for time-of-flight (TOF) PET
    • Aykac M, Bauer F, Williams CW, Loope M, Schmand M. Recent timing performance of Hi-Rez detector for time-of-flight (TOF) PET. IEEE T Nucl Sci. 2008; 53(3): 1084-1089.
    • (2008) IEEE T Nucl Sci , vol.53 , Issue.3 , pp. 1084-1089
    • Aykac, M.1    Bauer, F.2    Williams, C.W.3    Loope, M.4    Schmand, M.5
  • 18
    • 0031338124 scopus 로고    scopus 로고
    • Simulating the performances of an LSO based position encoding detector for PET
    • Moisan C, Vozza D, Loope M. Simulating the performances of an LSO based position encoding detector for PET. IEEE T Nucl Sci. 1997; 44(6): 2450-2458.
    • (1997) IEEE T Nucl Sci , vol.44 , Issue.6 , pp. 2450-2458
    • Moisan, C.1    Vozza, D.2    Loope, M.3
  • 20
    • 45849123920 scopus 로고    scopus 로고
    • An investigation into the use of Geiger-mode solide-state photomultipliers for simultaneous PET and MRI acquisition
    • Hong SJ, Song IC, Ito M, Kwon SI, Lee GS, Sim KS, Park KS, Rhee JT, Lee JS. An investigation into the use of Geiger-mode solide-state photomultipliers for simultaneous PET and MRI acquisition. IEEE T Nucl Sci. 2008; 55(3): 882-888.
    • (2008) IEEE T Nucl Sci , vol.55 , Issue.3 , pp. 882-888
    • Hong, S.J.1    Song, I.C.2    Ito, M.3    Kwon, S.I.4    Lee, G.S.5    Sim, K.S.6    Park, K.S.7    Rhee, J.T.8    Lee, J.S.9
  • 21
    • 84871751912 scopus 로고    scopus 로고
    • Geiger-mode avalanche photodiodes for PET/MRI
    • K. Iniewski (Ed.), Boca Raton: CRC Press LLC
    • Lee JS, Hong SJ. Geiger-mode avalanche photodiodes for PET/MRI. In: Iniewski K, editor. Electronic circuits for radiation detection. Boca Raton: CRC Press LLC; 2010. pp. 179-200.
    • (2010) Electronic Circuits for Radiation Detection , pp. 179-200
    • Lee, J.S.1    Hong, S.J.2
  • 23
    • 0023426484 scopus 로고
    • Depth-of-interaction determination in NaI(TI) and BGO scintillation crystals using a temperature gradient
    • Karp JS, Daube-Withespoon ME. Depth-of-interaction determination in NaI(TI) and BGO scintillation crystals using a temperature gradient. Nucl Instrum Meth A. 1987; 260: 509-517.
    • (1987) Nucl Instrum Meth A , vol.260 , pp. 509-517
    • Karp, J.S.1    Daube-Withespoon, M.E.2
  • 25
    • 0033311839 scopus 로고    scopus 로고
    • Depth identification accuracy of a three layer phoswich PET detector module
    • Seidel J, Vaquero JJ, Siegel S, Gandler WR, Green MV. Depth identification accuracy of a three layer phoswich PET detector module. IEEE T Nucl Sci. 1999; 46(3): 485-490.
    • (1999) IEEE T Nucl Sci , vol.46 , Issue.3 , pp. 485-490
    • Seidel, J.1    Vaquero, J.J.2    Siegel, S.3    Gandler, W.R.4    Green, M.V.5
  • 26
    • 34247281562 scopus 로고    scopus 로고
    • Comparison of pulse shape discrimination methods for phoswich and CsI:Tl detectors
    • Chandrikamohan P, DeVol TA. Comparison of pulse shape discrimination methods for phoswich and CsI: Tl detectors. IEEE T Nucl Sci. 2007; 54(2): 398-403.
    • (2007) IEEE T Nucl Sci , vol.54 , Issue.2 , pp. 398-403
    • Chandrikamohan, P.1    Devol, T.A.2
  • 27
    • 63649092601 scopus 로고    scopus 로고
    • Continuous depth-of-interaction encoding using phosphor-coated scintillators
    • Du H, Yang Y, Glodo J, Wu Y, Shah K, Cherry SR. Continuous depth-of-interaction encoding using phosphor-coated scintillators. Phys Med Biol. 2009; 54(6): 1757-1771.
    • (2009) Phys Med Biol , vol.54 , Issue.6 , pp. 1757-1771
    • Du, H.1    Yang, Y.2    Glodo, J.3    Wu, Y.4    Shah, K.5    Cherry, S.R.6
  • 28
    • 0038720472 scopus 로고    scopus 로고
    • Pulse shape discrimination of LSO and LuYAP scintillators for depth of interaction detection in PET
    • Streun M, Brandenburg G, Larue H, Saleh H, Zimmermann E, Ziemons K, Halling H. Pulse shape discrimination of LSO and LuYAP scintillators for depth of interaction detection in PET. IEEE T Nucl Sci. 2003; 50(3): 344-347.
    • (2003) IEEE T Nucl Sci , vol.50 , Issue.3 , pp. 344-347
    • Streun, M.1    Brandenburg, G.2    Larue, H.3    Saleh, H.4    Zimmermann, E.5    Ziemons, K.6    Halling, H.7
  • 29
    • 0034825229 scopus 로고    scopus 로고
    • Development of a depth of interaction detector for gamma-rays
    • Liu H, Omura T, Watanabe M, Yamashita T. Development of a depth of interaction detector for gamma-rays. Nucl Instrum Meth A. 2001; 459: 182-190.
    • (2001) Nucl Instrum Meth A , vol.459 , pp. 182-190
    • Liu, H.1    Omura, T.2    Watanabe, M.3    Yamashita, T.4
  • 30
    • 0036816184 scopus 로고    scopus 로고
    • Anode position and last dynode timing circuits for dual-layer BGO scintillator with PS-PMT based modular PET detectors
    • Zhang N, Thompson CJ, Togane D, Cayouette F, Nguyen KQ. Anode position and last dynode timing circuits for dual-layer BGO scintillator with PS-PMT based modular PET detectors. IEEE T Nucl Sci. 2002; 49(5): 2203-2207.
    • (2002) IEEE T Nucl Sci , vol.49 , Issue.5 , pp. 2203-2207
    • Zhang, N.1    Thompson, C.J.2    Togane, D.3    Cayouette, F.4    Nguyen, K.Q.5
  • 40
    • 22244440239 scopus 로고    scopus 로고
    • A true singles list-mode data acquisition system for a small animal PET scanner with independent crystal readout
    • McElroy DP, Hoose M, Pimpl W, Spanoudaki V, Schüler T, Ziegler SI. A true singles list-mode data acquisition system for a small animal PET scanner with independent crystal readout. Phys Med Biol. 2005; 50(14): 3323-3335.
    • (2005) Phys Med Biol , vol.50 , Issue.14 , pp. 3323-3335
    • McElroy, D.P.1    Hoose, M.2    Pimpl, W.3    Spanoudaki, V.4    Schüler, T.5    Ziegler, S.I.6
  • 41
    • 0036815754 scopus 로고    scopus 로고
    • Design of a high-resolution and high-sensitivity scintillation crystal array for PET with nearly complete light collection
    • Levin CS. Design of a high-resolution and high-sensitivity scintillation crystal array for PET with nearly complete light collection. IEEE T Nucl Sci. 2000; 49(5): 2236-2243.
    • (2000) IEEE T Nucl Sci , vol.49 , Issue.5 , pp. 2236-2243
    • Levin, C.S.1
  • 42
    • 77957718627 scopus 로고    scopus 로고
    • Performance characterization of a new high resolution PET scintillation detector
    • Vandenbroucke A, Foudray AM, Olcott PD, Levin CS. Performance characterization of a new high resolution PET scintillation detector. Phys Med Biol. 2010; 55(19): 5895-5911.
    • (2010) Phys Med Biol , vol.55 , Issue.19 , pp. 5895-5911
    • Vandenbroucke, A.1    Foudray, A.M.2    Olcott, P.D.3    Levin, C.S.4
  • 47
    • 33645990583 scopus 로고    scopus 로고
    • Depth of interaction resolution measurements for a high resolution PET detector using position sensitive avalanche photodiodes
    • Yang Y, Dokhale PA, Silverman RW, Shah KS, McClish MA, Farrell R, Entine G, Cherry SR. Depth of interaction resolution measurements for a high resolution PET detector using position sensitive avalanche photodiodes. Phys Med Biol. 2006; 51(9): 2131-2142.
    • (2006) Phys Med Biol , vol.51 , Issue.9 , pp. 2131-2142
    • Yang, Y.1    Dokhale, P.A.2    Silverman, R.W.3    Shah, K.S.4    McClish, M.A.5    Farrell, R.6    Entine, G.7    Cherry, S.R.8
  • 49
    • 34548486507 scopus 로고    scopus 로고
    • Initial experimental studies of using solidstate photomultiplier for PET applications
    • Shao Y, Li H, Gao K. Initial experimental studies of using solidstate photomultiplier for PET applications. Nucl Instrum Meth A. 2007; 580(2): 944-950.
    • (2007) Nucl Instrum Meth A , vol.580 , Issue.2 , pp. 944-950
    • Shao, Y.1    Li, H.2    Gao, K.3
  • 52
    • 34249093003 scopus 로고    scopus 로고
    • Measurements of wavelength shifting (WLS) fibre readout for a highly multiplexed, depthencoding PET detector
    • Du H, Yang Y, Cherry SR. Measurements of wavelength shifting (WLS) fibre readout for a highly multiplexed, depthencoding PET detector. Phys Med Biol. 2007; 52(9): 2499-2514.
    • (2007) Phys Med Biol , vol.52 , Issue.9 , pp. 2499-2514
    • Du, H.1    Yang, Y.2    Cherry, S.R.3
  • 53
    • 77955609487 scopus 로고    scopus 로고
    • The challenge of detector designs for PET
    • Lewellen TK. The challenge of detector designs for PET. AJR Am J Roentgenol. 2010; 195(2): 301-309.
    • (2010) AJR Am J Roentgenol , vol.195 , Issue.2 , pp. 301-309
    • Lewellen, T.K.1
  • 55
    • 0037151412 scopus 로고    scopus 로고
    • cMiCE: a high resolution animal PET using continuous LSO with a statistics based positioning scheme
    • Joung J, Miyaoka RS, Lewellen TK. cMiCE: a high resolution animal PET using continuous LSO with a statistics based positioning scheme. Nucl Instrum Meth A. 2002; 489(1-3): 584-598.
    • (2002) Nucl Instrum Meth A , vol.489 , Issue.1-3 , pp. 584-598
    • Joung, J.1    Miyaoka, R.S.2    Lewellen, T.K.3
  • 56
    • 34147139307 scopus 로고    scopus 로고
    • Depth of interaction decoding of a continuous crystal detector module
    • Ling T, Lewellen TK, Miyaoka RS. Depth of interaction decoding of a continuous crystal detector module. Phys Med Biol. 2007; 52(8): 2213-2228.
    • (2007) Phys Med Biol , vol.52 , Issue.8 , pp. 2213-2228
    • Ling, T.1    Lewellen, T.K.2    Miyaoka, R.S.3
  • 58
    • 10744231688 scopus 로고    scopus 로고
    • Study of spatial resolution and depth of interaction of APD-based PET detector modules using light sharing schemes
    • Bruyndonckx P, Leonard S, Liu J, Tavernier S, Szupryczynski P, Fedorov A. Study of spatial resolution and depth of interaction of APD-based PET detector modules using light sharing schemes. IEEE T Nucl Sci. 2003; 50(5): 1415-1419.
    • (2003) IEEE T Nucl Sci , vol.50 , Issue.5 , pp. 1415-1419
    • Bruyndonckx, P.1    Leonard, S.2    Liu, J.3    Tavernier, S.4    Szupryczynski, P.5    Fedorov, A.6
  • 62
    • 77957914852 scopus 로고    scopus 로고
    • Time walk correction for TOF-PET detectors based on a monolithic scintillation crystal coupled to a photosensor array
    • Vinke R, Löhner H, Schaart DR, van Dam HT, Seifert S, Beekman FJ, Dendooven P. Time walk correction for TOF-PET detectors based on a monolithic scintillation crystal coupled to a photosensor array. Nucl Instrum Meth A. 2010; 621(1-3): 595-604.
    • (2010) Nucl Instrum Meth A , vol.621 , Issue.1-3 , pp. 595-604
    • Vinke, R.1    Löhner, H.2    Schaart, D.R.3    van Dam, H.T.4    Seifert, S.5    Beekman, F.J.6    Dendooven, P.7
  • 63
    • 48049110712 scopus 로고    scopus 로고
    • New design of a quasimonolithic detector module with DOI capability for small animal PET
    • Chung YH, Lee S-J, Beak C-H, Choi Y. New design of a quasimonolithic detector module with DOI capability for small animal PET. Nucl Instrum Meth A. 2008; 593(3): 588-591.
    • (2008) Nucl Instrum Meth A , vol.593 , Issue.3 , pp. 588-591
    • Chung, Y.H.1    Lee, S.-J.2    Beak, C.-H.3    Choi, Y.4
  • 64
    • 77957915070 scopus 로고    scopus 로고
    • Preliminary experimental results of a quasi-monolithic detector with DOI capability for a small animal PET
    • Lee S-J, Baek C-H, Hwang JY, Choi Y, Chung YH. Preliminary experimental results of a quasi-monolithic detector with DOI capability for a small animal PET. Nucl Instrum Meth A. 2010; 621: 590-594.
    • (2010) Nucl Instrum Meth A , vol.621 , pp. 590-594
    • Lee, S.-J.1    Baek, C.-H.2    Hwang, J.Y.3    Choi, Y.4    Chung, Y.H.5
  • 65
    • 67649194813 scopus 로고    scopus 로고
    • A cross-stack quasimonolithic detector with DOI capability for a small animal PET
    • Lee S-J, Baek C-H, Chung YH, Choi Y. A cross-stack quasimonolithic detector with DOI capability for a small animal PET. Conf Rec IEEE NSS MIC, 2008; M06-M81.
    • (2008) Conf Rec IEEE NSS MIC
    • Lee, S.-J.1    Baek, C.-H.2    Chung, Y.H.3    Choi, Y.4
  • 66
    • 0032096198 scopus 로고    scopus 로고
    • Design of a depth of interaction^(DOI) PET detector module
    • Miyaoka RS, Lewellen TK. Design of a depth of interaction (DOI) PET detector module. IEEE T Nucl Sci. 1998; 45(4): 1069-1073.
    • (1998) IEEE T Nucl Sci , vol.45 , Issue.4 , pp. 1069-1073
    • Miyaoka, R.S.1    Lewellen, T.K.2
  • 67
    • 84863009364 scopus 로고    scopus 로고
    • DMice-a depth-ofinteraction detector design for PET scanners
    • Lewellen TK, Janes M, Miyaoka RS. DMice-a depth-ofinteraction detector design for PET scanners. Conf Rec IEEE NSS MIC. 2002; 2288-92.
    • (2002) Conf Rec IEEE NSS MIC , pp. 2288-2292
    • Lewellen, T.K.1    Janes, M.2    Miyaoka, R.S.3
  • 69
    • 70350136716 scopus 로고    scopus 로고
    • Investigation of depth of interaction encoding for a pixelated LSO array with a single multi-channel PMT
    • Yang Y, Wu Y, Cherry SR. Investigation of depth of interaction encoding for a pixelated LSO array with a single multi-channel PMT. IEEE T Nucl Sci. 2009; 56(5): 2594-2599.
    • (2009) IEEE T Nucl Sci , vol.56 , Issue.5 , pp. 2594-2599
    • Yang, Y.1    Wu, Y.2    Cherry, S.R.3
  • 70
    • 77953819441 scopus 로고    scopus 로고
    • Design and simulation of a novel method for determining depth-of-interaction in a PET scintillation crystal array using a singleended readout by a multi-anode PMT
    • Ito M, Lee JS, Park MJ, Sim KS, Hong SJ. Design and simulation of a novel method for determining depth-of-interaction in a PET scintillation crystal array using a singleended readout by a multi-anode PMT. Phys Med Biol. 2010; 55(13): 3827-3841.
    • (2010) Phys Med Biol , vol.55 , Issue.13 , pp. 3827-3841
    • Ito, M.1    Lee, J.S.2    Park, M.J.3    Sim, K.S.4    Hong, S.J.5
  • 71
    • 79952108281 scopus 로고    scopus 로고
    • Simplified simulation of four-layer depth of interaction detector for PET
    • Haneishi H, Sato M, Inadama N, Murayama H. Simplified simulation of four-layer depth of interaction detector for PET. Radiol Phys Technol. 2008; 1(1): 106-114.
    • (2008) Radiol Phys Technol , vol.1 , Issue.1 , pp. 106-114
    • Haneishi, H.1    Sato, M.2    Inadama, N.3    Murayama, H.4
  • 72
    • 84862982797 scopus 로고
    • Resolution and sensitivity improvement in positron emission tomography by the first interaction point determination
    • Cho ZH, Juh SC. Resolution and sensitivity improvement in positron emission tomography by the first interaction point determination. Conf Rec IEEE NSS MIC. 1991; 1623-7.
    • (1991) Conf Rec IEEE NSS MIC , pp. 1623-1627
    • Cho, Z.H.1    Juh, S.C.2
  • 73
    • 0030211634 scopus 로고    scopus 로고
    • Algorithms to identify detector Compton scatter in PET modules
    • Comanor KA, Virador PRG, Moses WW. Algorithms to identify detector Compton scatter in PET modules. IEEE T Nucl Sci. 1996; 43(4): 2213-2219.
    • (1996) IEEE T Nucl Sci , vol.43 , Issue.4 , pp. 2213-2219
    • Comanor, K.A.1    Virador, P.R.G.2    Moses, W.W.3
  • 74
    • 0034245271 scopus 로고    scopus 로고
    • Effect of detector scatter on the decoding accuracy of a DOI detector
    • Miyaoka RS, Lewellen TK. Effect of detector scatter on the decoding accuracy of a DOI detector. IEEE T Nucl Sci. 2000; 47(4): 1614-1619.
    • (2000) IEEE T Nucl Sci , vol.47 , Issue.4 , pp. 1614-1619
    • Miyaoka, R.S.1    Lewellen, T.K.2
  • 75
    • 11844282781 scopus 로고    scopus 로고
    • Effect of inter-crystal Compton scatter on efficiency and image noise in small animal PET module
    • Park S-J, Rogers WL, Clinthorne NH. Effect of inter-crystal Compton scatter on efficiency and image noise in small animal PET module. Conf Rec IEEE NSS MIC. 2003; M3-M115.
    • (2003) Conf Rec IEEE NSS MIC
    • Park, S.-J.1    Rogers, W.L.2    Clinthorne, N.H.3
  • 76
    • 78349267891 scopus 로고    scopus 로고
    • The influence of crystal material on intercrystal scattering and the parallax effect in PET block detectors: A Monte Carlo study
    • Lashkari S, Sarkar S, Ay MR, Rahmim A. The influence of crystal material on intercrystal scattering and the parallax effect in PET block detectors: A Monte Carlo study. IFMBE Proc. 2008; 21(8): 633-636.
    • (2008) IFMBE Proc , vol.21 , Issue.8 , pp. 633-636
    • Lashkari, S.1    Sarkar, S.2    Ay, M.R.3    Rahmim, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.