메뉴 건너뛰기




Volumn 52, Issue 4, 2011, Pages 572-579

Development of small-animal PET prototype using silicon photomultiplier (SiPM): Initial results of phantom and animal imaging studies

Author keywords

Geiger mode APD (G APD); PE.T.; PET MRI; Semi conductor photo sensor; Silicon photomultiplier (SiPM)

Indexed keywords

ARGINYLGLYCYLASPARTIC ACID GA 68; FLUORINE 18; FLUORODEOXYGLUCOSE F 18; LUTETIUM; LUTETIUM GADOLINIUM OXYORTHOSILICATE; SILICON; SODIUM 22; UNCLASSIFIED DRUG;

EID: 79954611852     PISSN: 01615505     EISSN: None     Source Type: Journal    
DOI: 10.2967/jnumed.110.079707     Document Type: Article
Times cited : (96)

References (34)
  • 1
    • 46749154311 scopus 로고    scopus 로고
    • Latest advances in molecular imaging instrumentation
    • DOI 10.2967/jnumed.108.045880
    • Pichler BJ, Wehrl HF, Judenhofer MS. Latest advances in molecular imaging instrumentation. J Nucl Med. 2008;49(suppl 2):5S-23S. (Pubitemid 351948034)
    • (2008) Journal of Nuclear Medicine , vol.49 , Issue.SUPPL.6
    • Pichler, B.J.1    Wehrl, H.F.2    Judenhofer, M.S.3
  • 2
    • 60549093719 scopus 로고    scopus 로고
    • Novel detector technology for clinical PET
    • Lecomte R. Novel detector technology for clinical PET. Eur J Nucl Med Mol Imaging. 2009;36(suppl 1):S69-S85.
    • (2009) Eur J Nucl Med Mol Imaging. , vol.36 , Issue.SUPPL. 1
    • Lecomte, R.1
  • 3
    • 0035117806 scopus 로고    scopus 로고
    • A prototype high-resolution animal positron tomograph with avalanche photodiode arrays and LSO crystals
    • Ziegler SI, Pichler BJ, Boening G, et al. A prototype high-resolution animal positron tomograph with avalanche photodiode arrays and LSO crystals. Eur J Nucl Med. 2001;28:136-143.
    • (2001) Eur J Nucl Med. , vol.28 , pp. 136-143
    • Ziegler, S.I.1    Pichler, B.J.2    Boening, G.3
  • 4
    • 60449085244 scopus 로고    scopus 로고
    • The hardware and signal processing architecture of LabPET (TM), a small animal APD-based digital PET scanner
    • Fontaine R, Belanger F, Viscogliosi N, et al. The hardware and signal processing architecture of LabPET (TM), a small animal APD-based digital PET scanner. IEEE Trans Nucl Sci. 2009;56:3-9.
    • (2009) IEEE Trans Nucl Sci. , vol.56 , pp. 3-9
    • Fontaine, R.1    Belanger, F.2    Viscogliosi, N.3
  • 6
    • 51549120220 scopus 로고    scopus 로고
    • Simultaneous MR/PET imaging of the human brain: Feasibility study
    • Schlemmer HP, Pichler BJ, Schmand M, et al. Simultaneous MR/PET imaging of the human brain: Feasibility study. Radiology. 2008;248:1028-1035.
    • (2008) Radiology. , vol.248 , pp. 1028-1035
    • Schlemmer, H.P.1    Pichler, B.J.2    Schmand, M.3
  • 7
    • 51849109068 scopus 로고    scopus 로고
    • Recent developments in PET detector technology
    • Lewellen TK. Recent developments in PET detector technology. Phys Med Biol. 2008;53:R287-R317.
    • (2008) Phys Med Biol. , vol.53
    • Lewellen, T.K.1
  • 8
    • 84871751912 scopus 로고    scopus 로고
    • Geiger-mode avalanche photodiodes for PET/MRI
    • In:*Iniewski K eds Boca Raton, FL: CRC Press LLC
    • Lee JS, Hong SJ. Geiger-mode avalanche photodiodes for PET/MRI. In: *Iniewski K, eds. Electronic Circuits for Radiation Detection. Boca Raton, FL: CRC Press LLC; 2010:179-200.
    • (2010) Electronic Circuits for Radiation Detection , pp. 179-200
    • Lee, J.S.1    Hong, S.J.2
  • 9
    • 70449381116 scopus 로고    scopus 로고
    • Advances in solid state photon detectors
    • Renker D, Lorenz E. Advances in solid state photon detectors. J Inst. 2009;4: P04004.
    • (2009) J Inst. , vol.4
    • Renker, D.1    Lorenz, E.2
  • 10
    • 34250156727 scopus 로고    scopus 로고
    • Investigation of solid-state photomultipliers for positron emission tomography scanners
    • Lee JS, Ito M, Sim KS, et al. Investigation of solid-state photomultipliers for positron emission tomography scanners. J Korean Phys Soc. 2007;50:1332-1339.
    • (2007) J Korean Phys Soc. , vol.50 , pp. 1332-1339
    • Lee, J.S.1    Ito, M.2    Sim, K.S.3
  • 11
    • 45849123920 scopus 로고    scopus 로고
    • An investigation into the use of Geiger-mode solid-state photomultipliers for simultaneous PET and MRI acquisition
    • Hong SJ, Song IC, Ito M, et al. An investigation into the use of Geiger-mode solid-state photomultipliers for simultaneous PET and MRI acquisition. IEEE Trans Nucl Sci. 2008;55:882-888.
    • (2008) IEEE Trans Nucl Sci. , vol.55 , pp. 882-888
    • Hong, S.J.1    Song, I.C.2    Ito, M.3
  • 12
    • 70350176156 scopus 로고    scopus 로고
    • Multi-pixel photon counters for TOF PET detector and its challengesqConcept verificatio
    • Kim CL, Wang GC, Dolinsky S. Multi-pixel photon counters for TOF PET detector and its challenges. IEEE Trans Nucl Sci. 2009;56:2580-2585.
    • (2009) IEEE Trans Nucl Sci. , vol.56 , pp. 2580-2585
    • Kim, C.L.1    Wang, G.C.2    Dolinsky, S.3
  • 13
    • 69249219386 scopus 로고    scopus 로고
    • A novel, SiPM-array-based, monolithic scintillator detector for PET
    • Schaart DR, van Dam HT, Seifert S, et al. A novel, SiPM-array-based, monolithic scintillator detector for PET. Phys Med Biol. 2009;54:3501-3512.
    • (2009) Phys Med Biol. , vol.54 , pp. 3501-3512
    • Schaart, D.R.1    Van Dam, H.T.2    Seifert, S.3
  • 14
    • 45849125819 scopus 로고    scopus 로고
    • Concept verification of three-layer DOI detectors for small animal PET
    • Hong SJ, Kwon SI, Ito M, et al. Concept verification of three-layer DOI detectors for small animal PET. IEEE Trans Nucl Sci. 2008;55:912-917.
    • (2008) IEEE Trans Nucl Sci. , vol.55 , pp. 912-917
    • Hong, S.J.1    Kwon, S.I.2    Ito, M.3
  • 15
    • 77953716267 scopus 로고    scopus 로고
    • Development of position encoding circuit for a multi-anode position sensitive photomultiplier tube
    • Kwon SI, Hong SJ, Ito M, et al. Development of position encoding circuit for a multi-anode position sensitive photomultiplier tube. Nucl Med Mol Imaging2008;42:469-477.
    • (2008) Nucl Med Mol Imaging , vol.42 , pp. 469-477
    • Kwon, S.I.1    Hong, S.J.2    Ito, M.3
  • 16
    • 77953718569 scopus 로고    scopus 로고
    • A four-layer DOI detector with a relative offset for use in an animal PET system
    • Ito M, Lee JS, Kwon SI, et al. A four-layer DOI detector with a relative offset for use in an animal PET system. IEEE Trans Nucl Sci. 2010;57:976-981.
    • (2010) IEEE Trans Nucl Sci. , vol.57 , pp. 976-981
    • Ito, M.1    Lee, J.S.2    Kwon, S.I.3
  • 18
    • 34247229328 scopus 로고    scopus 로고
    • Performance evaluation of the GE healthcare eXplore VISTA dual-ring small-animal PET scanner
    • Wang Y, Seidel J, Tsui BM, Vaquero JJ, Pomper MG. Performance evaluation of the GE Healthcare eXplore VISTA dual-ring small-animal PET scanner. J Nucl Med. 2006;47:1891-1900. (Pubitemid 47545013)
    • (2006) Journal of Nuclear Medicine , vol.47 , Issue.11 , pp. 1891-1900
    • Wang, Y.1    Seidel, J.2    Tsui, B.M.W.3    Vaquero, J.J.4    Pomper, M.G.5
  • 21
    • 34548580353 scopus 로고    scopus 로고
    • Performance measurement of the microPET Focus 120 scanner
    • Kim JS, Lee JS, Im KC, et al. Performance measurement of the microPET Focus 120 scanner. J Nucl Med. 2007;48:1527-1535.
    • (2007) J Nucl Med. , vol.48 , pp. 1527-1535
    • Kim, J.S.1    Lee, J.S.2    Im, K.C.3
  • 22
    • 44149120982 scopus 로고    scopus 로고
    • Preparation of a promising angiogenesis PET imaging agent: 68Ga-labeled c(RGDyK)-isothiocyanatobenzyl-1,4,7-triazacyclononane- 1, 4,7-triacetic acid and feasibility studies in mice
    • Jeong JM, Hong MK, Chang YS, et al. Preparation of a promising angiogenesis PET imaging agent: 68Ga-labeled c(RGDyK)-isothiocyanatobenzyl-1,4, 7-triazacyclononane- 1,4,7-triacetic acid and feasibility studies in mice. J Nucl Med.2008;49:830-836.
    • (2008) J Nucl Med. , vol.49 , pp. 830-836
    • Jeong, J.M.1    Hong, M.K.2    Chang, Y.S.3
  • 23
    • 79952735576 scopus 로고    scopus 로고
    • 68Ga-labeled radiopharmaceuticals for positron emission tomography
    • Shetty D, Lee Y-S, Jeong JM. 68Ga-labeled radiopharmaceuticals for positron emission tomography. Nucl Med Mol Imaging. 2010;44:233-240.
    • (2010) Nucl Med Mol Imaging. , vol.44 , pp. 233-240
    • Shetty, D.1    Lee, Y-.S.2    Jeong, J.M.3
  • 28
    • 79954582561 scopus 로고    scopus 로고
    • Technical advances in current PET and hybrid imaging systems
    • Lee JS. Technical advances in current PET and hybrid imaging systems. Open Nucl Med J. 2010;2:192-208.
    • (2010) Open Nucl Med J. , vol.2 , pp. 192-208
    • Lee, J.S.1
  • 29
    • 77951195515 scopus 로고    scopus 로고
    • The digital silicon photomultiplier: A novel sensor for the detection of scintillation light
    • Degenhardt C, Prescher G, Frach T, et al. The digital silicon photomultiplier: A novel sensor for the detection of scintillation light. IEEE Nucl Sci Symp Conf Rec. 2009:2383-2386.
    • (2009) IEEE Nucl Sci Symp Conf Rec. , pp. 2383-2386
    • Degenhardt, C.1    Prescher, G.2    Frach, T.3
  • 31
    • 84862895366 scopus 로고    scopus 로고
    • Positron emission tomography (PET) detectors with depth-of-interaction (DOI) capability
    • In press
    • Ito M, Hong SJ, Lee JS. Positron emission tomography (PET) detectors with depth-of-interaction (DOI) capability. Biomed Eng Lett. In press.
    • Biomed Eng Lett.
    • Ito, M.1    Hong, S.J.2    Lee, J.S.3
  • 32
    • 77953819441 scopus 로고    scopus 로고
    • Design and simulation of a novel method for determining depth-of-interaction in a PET scintillation crystal array using a single-ended readout by a multi-anode PMT
    • Ito M, Lee JS, Park MJ, Sim KS, Hong SJ. Design and simulation of a novel method for determining depth-of-interaction in a PET scintillation crystal array using a single-ended readout by a multi-anode PMT. Phys Med Biol. 2010;55:3827-3841.
    • (2010) Phys Med Biol. , vol.55 , pp. 3827-3841
    • Ito, M.1    Lee, J.S.2    Park, M.J.3    Sim, K.S.4    Hong, S.J.5
  • 33
    • 62449092307 scopus 로고    scopus 로고
    • Performance evaluation of the Inveon dedicated PET preclinical tomograph based on the NEMA NU-4 standards
    • Bao Q, Newport D, Chen M, Stout DB, Chatziioannou AF. Performance evaluation of the Inveon dedicated PET preclinical tomograph based on the NEMA NU-4 standards. J Nucl Med. 2009;50:401-408.
    • (2009) J Nucl Med. , vol.50 , pp. 401-408
    • Bao, Q.1    Newport, D.2    Chen, M.3    Stout, D.B.4    Chatziioannou, A.F.5
  • 34
    • 79954621704 scopus 로고    scopus 로고
    • Development of SSPMPET with digitally controlled bias voltage supply [abstract]
    • Kwon SI, Hong SJ, Ito M, Yoon HS, Song IC, Lee JS. Development of SSPMPET with digitally controlled bias voltage supply [abstract]. J Nucl Med. 2009;50 (suppl):93P.
    • (2009) J Nucl Med. , vol.50 , Issue.SUPPL.
    • Kwon, S.I.1    Hong, S.J.2    Ito, M.3    Yoon, H.S.4    Song, I.C.5    Lee, J.S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.