메뉴 건너뛰기




Volumn 53, Issue 6, 2012, Pages 977-984

Variable lung density consideration in attenuation correction of whole-body PET/MRI

Author keywords

Attenuation correction; Lung density; PET MRI; Segmentation; Whole body imaging

Indexed keywords

FLUORODEOXYGLUCOSE F 18;

EID: 84861883596     PISSN: 01615505     EISSN: None     Source Type: Journal    
DOI: 10.2967/jnumed.111.098350     Document Type: Article
Times cited : (51)

References (36)
  • 1
    • 71849117812 scopus 로고    scopus 로고
    • The current state, challenges, and perspectives of MR-PET
    • Herzog H, Pietrzyk U, Shah NJ, Ziemons K. The current state, challenges, and perspectives of MR-PET. Neuroimage. 2010;49:2072-2082.
    • (2010) Neuroimage , vol.49 , pp. 2072-2082
    • Herzog, H.1    Pietrzyk, U.2    Shah, N.J.3    Ziemons, K.4
  • 2
    • 60549093826 scopus 로고    scopus 로고
    • The potential of PET/MR for brain imaging
    • Heiss W-D. The potential of PET/MR for brain imaging. Eur J Nucl Med Mol Imaging. 2009;36(suppl 1):S105-S112.
    • (2009) Eur J Nucl Med Mol Imaging , vol.36 , Issue.SUPPL. 1
    • Heiss, W.-D.1
  • 4
    • 60649120728 scopus 로고    scopus 로고
    • PET and MRI in cardiac imaging: From validation studies to integrated applications
    • Nekolla SG, Martinez-Moeller A, Saraste A. PET and MRI in cardiac imaging: From validation studies to integrated applications. Eur J Nucl Med Mol Imaging. 2009;36(suppl 1):S121-S130.
    • (2009) Eur J Nucl Med Mol Imaging , vol.36 , Issue.SUPPL. 1
    • Nekolla, S.G.1    Martinez-Moeller, A.2    Saraste, A.3
  • 5
    • 77956216707 scopus 로고    scopus 로고
    • Hybrid PET/MRI of intracranial masses: Initial experiences and comparison to PET/CT
    • Boss A, Bisdas S, Kolb A, et al. Hybrid PET/MRI of intracranial masses: initial experiences and comparison to PET/CT. J Nucl Med. 2010;51:1198-1205.
    • (2010) J Nucl Med , vol.51 , pp. 1198-1205
    • Boss, A.1    Bisdas, S.2    Kolb, A.3
  • 6
    • 79952284188 scopus 로고    scopus 로고
    • Bimodal thrombus imaging: Simultaneous PET/MR imaging with a fibrin-targeted dual PET/MR probe - Feasibility study in rat model
    • Uppal R, Catana C, Ay I, Benner T, Sorensen AG, Caravan P. Bimodal thrombus imaging: simultaneous PET/MR imaging with a fibrin-targeted dual PET/MR probe - feasibility study in rat model. Radiology. 2011;258:812-820.
    • (2011) Radiology , vol.258 , pp. 812-820
    • Uppal, R.1    Catana, C.2    Ay, I.3    Benner, T.4    Sorensen, A.G.5    Caravan, P.6
  • 7
    • 77952358732 scopus 로고    scopus 로고
    • MR-based attenuation correction for hybrid PET-MR brain imaging systems using deformable image registration
    • Schreibmann E, Nye JA, Schuster DM, Martin DR, Votaw J, Fox T. MR-based attenuation correction for hybrid PET-MR brain imaging systems using deformable image registration. Med Phys. 2010;37:2101-2109.
    • (2010) Med Phys , vol.37 , pp. 2101-2109
    • Schreibmann, E.1    Nye, J.A.2    Schuster, D.M.3    Martin, D.R.4    Votaw, J.5    Fox, T.6
  • 8
    • 57349155316 scopus 로고    scopus 로고
    • MRI-based attenuation correction for PET/MRI: A novel approach combining pattern recognition and atlas registration
    • Hofmann M, Steinke F, Scheel V, et al. MRI-based attenuation correction for PET/MRI: a novel approach combining pattern recognition and atlas registration. J Nucl Med. 2008;49:1875-1883.
    • (2008) J Nucl Med , vol.49 , pp. 1875-1883
    • Hofmann, M.1    Steinke, F.2    Scheel, V.3
  • 9
    • 63849338624 scopus 로고    scopus 로고
    • Tissue classification as a potential approach for attenuation correction in whole-body PET/MRI: Evaluation with PET/CT data
    • Martinez-Möller A, Souvatzoglou M, Delso G, et al. Tissue classification as a potential approach for attenuation correction in whole-body PET/MRI: evaluation with PET/CT data. J Nucl Med. 2009;50:520-526.
    • (2009) J Nucl Med , vol.50 , pp. 520-526
    • Martinez-Möller, A.1    Souvatzoglou, M.2    Delso, G.3
  • 10
    • 77957038794 scopus 로고    scopus 로고
    • Toward implementing an MRI-based PET attenuation-correction method for neurologic studies on the MR-PET brain prototype
    • Catana C, van der Kouwe A, Benner T, et al. Toward implementing an MRI-based PET attenuation-correction method for neurologic studies on the MR-PET brain prototype. J Nucl Med. 2010;51:1431-1438.
    • (2010) J Nucl Med , vol.51 , pp. 1431-1438
    • Catana, C.1    Van Der Kouwe, A.2    Benner, T.3
  • 12
    • 79551523276 scopus 로고    scopus 로고
    • Automatic, three-segment, MR-based attenuation correction for whole-body PET/MR data
    • Schulz V, Torres-Espallardo I, Renisch S, et al. Automatic, three-segment, MR-based attenuation correction for whole-body PET/MR data. Eur J Nucl Med Mol Imaging. 2011;38:138-152.
    • (2011) Eur J Nucl Med Mol Imaging , vol.38 , pp. 138-152
    • Schulz, V.1    Torres-Espallardo, I.2    Renisch, S.3
  • 13
    • 76949090527 scopus 로고    scopus 로고
    • Three-region MRI-based whole-body attenuation correction for automated PET reconstruction
    • Steinberg J, Jia G, Sammet S, Zhang J, Hall N, Knopp MV. Three-region MRI-based whole-body attenuation correction for automated PET reconstruction. Nucl Med Biol. 2010;37:227-235.
    • (2010) Nucl Med Biol , vol.37 , pp. 227-235
    • Steinberg, J.1    Jia, G.2    Sammet, S.3    Zhang, J.4    Hall, N.5    Knopp, M.V.6
  • 15
    • 80052644918 scopus 로고    scopus 로고
    • MRI-based attenuation correction for whole-body PET/MRI: Quantitative evaluation of segmentation- And atlas-based methods
    • Hofmann M, Bezrukov I, Mantlik F, et al. MRI-based attenuation correction for whole-body PET/MRI: quantitative evaluation of segmentation- and atlas-based methods. J Nucl Med. 2011;52:1392-1399.
    • (2011) J Nucl Med , vol.52 , pp. 1392-1399
    • Hofmann, M.1    Bezrukov, I.2    Mantlik, F.3
  • 16
    • 0026728203 scopus 로고
    • Measurement of lung density by means of quantitative CT scanning. A study of correlations with pulmonary function tests
    • Heremans A, Verschakelen L. Van fraeyenhoven L, Demedts M. Measurement of lung density by means of quantitative CT scanning. A study of correlations with pulmonary function tests. Chest. 1992;102:805-811.
    • (1992) Chest , vol.102 , pp. 805-811
    • Heremans, A.1    Verschakelen, L.2    Van Fraeyenhoven, L.3    Demedts, M.4
  • 17
    • 0025349284 scopus 로고
    • Measurement of pulmonary parenchymal attenuation: Use of spirometric gating with quantitative CT
    • Kalender WA, Rienmüller R, Seissler W, Behr J, Welke M, Fichte H. Measurement of pulmonary parenchymal attenuation: use of spirometric gating with quantitative CT. Radiology. 1990;175:265-268. (Pubitemid 20108578)
    • (1990) Radiology , vol.175 , Issue.1 , pp. 265-268
    • Kalendar, W.A.1    Rienmuller, R.2    Seissler, W.3    Behr, J.4    Welke, M.5    Fichte, H.6
  • 18
    • 0025810122 scopus 로고
    • Body position changes redistribute lung computed-tomography density in patients with acute respiratory failure
    • Gattinoni L, Pelosi P, Vitale G, Pesenti A, D'Andrea L, Mascheroni D. Body position changes redistribute lung computed-tomography density in patients with acute respiratory failure. Anesthesiology. 1991;74:15-23.
    • (1991) Anesthesiology , vol.74 , pp. 15-23
    • Gattinoni, L.1    Pelosi, P.2    Vitale, G.3    Pesenti, A.4    D'Andrea, L.5    Mascheroni, D.6
  • 21
    • 0025101237 scopus 로고
    • Quantitation of emphysema by computed tomography using a 'density mask' program and correlation with pulmonary function tests
    • Kinsella M, Müller NL, Abboud RT, Morrison NJ. DyBuncio A. Quantitation of emphysema by computed tomography using a "density mask" program and correlation with pulmonary function tests. Chest. 1990;97:315-321. (Pubitemid 20050666)
    • (1990) Chest , vol.97 , Issue.2 , pp. 315-321
    • Kinsella, M.1    Muller, N.L.2    Abboud, R.T.3    Morrison, N.J.4    DyBuncio, A.5
  • 23
    • 0002926370 scopus 로고
    • A mathematical model of diamagnetic line broadening in lung tissue and similar heterogeneous systems: Calculations and measurements
    • Case TA, Durney CH, Ailion DC, Cutillo AG, Morris AH. A mathematical model of diamagnetic line broadening in lung tissue and similar heterogeneous systems: calculations and measurements. J Magn Reson. 1987;73:304-314.
    • (1987) J Magn Reson , vol.73 , pp. 304-314
    • Case, T.A.1    Durney, C.H.2    Ailion, D.C.3    Cutillo, A.G.4    Morris, A.H.5
  • 24
    • 0032587625 scopus 로고    scopus 로고
    • T2*and proton density measurement of normal human lung parenchyma using submillisecond echo time gradient echo magnetic resonance imaging
    • DOI 10.1016/S0720-048X(98)00169-7, PII S0720048X98001697
    • Hatabu H, Alsop DC, Listerud J, Bonnet M, Gefter WB. T2*and proton density measurement of normal human lung parenchyma using submillisecond echo time gradient echo magnetic resonance imaging. Eur J Radiol. 1999;29:245-252. (Pubitemid 29268376)
    • (1999) European Journal of Radiology , vol.29 , Issue.3 , pp. 245-252
    • Hatabu, H.1    Alsop, D.C.2    Listerud, J.3    Bonnet, M.4    Gefter, W.B.5
  • 27
    • 79960368346 scopus 로고    scopus 로고
    • A comparison of MR-based attenuation correction in PET versus SPECT
    • Marshall HR, Stodilka RZ, Theberge J, et al. A comparison of MR-based attenuation correction in PET versus SPECT. Phys Med Biol. 2011;56:4613-4629.
    • (2011) Phys Med Biol , vol.56 , pp. 4613-4629
    • Marshall, H.R.1    Stodilka, R.Z.2    Theberge, J.3
  • 28
    • 33744930583 scopus 로고    scopus 로고
    • User-guided 3D active contour segmentation of anatomical structures: Significantly improved efficiency and reliability
    • DOI 10.1016/j.neuroimage.2006.01.015, PII S1053811906000632
    • Yushkevich PA, Piven J, Hazlett HC, et al. User-guided 3D active contour segmentation of anatomical structures: significantly improved efficiency and reliability. Neuroimage. 2006;31:1116-1128. (Pubitemid 43851334)
    • (2006) NeuroImage , vol.31 , Issue.3 , pp. 1116-1128
    • Yushkevich, P.A.1    Piven, J.2    Hazlett, H.C.3    Smith, R.G.4    Ho, S.5    Gee, J.C.6    Gerig, G.7
  • 30
    • 70449393519 scopus 로고    scopus 로고
    • 18F-Fluorodeoxyglucose-PET/CT imaging of lungs in patients with cystic fibrosis
    • 18F- Fluorodeoxyglucose-PET/CT imaging of lungs in patients with cystic fibrosis. Chest. 2009;136:1220-1228.
    • (2009) Chest , vol.136 , pp. 1220-1228
    • Klein, M.1    Cohen-Cymberknoh, M.2    Armoni, S.3
  • 32
    • 78649677882 scopus 로고    scopus 로고
    • Lung perfusion measured using magnetic resonance imaging: New tools for physiological insights into the pulmonary circulation
    • Hopkins SR, Prisk GK. Lung perfusion measured using magnetic resonance imaging: new tools for physiological insights into the pulmonary circulation. J Magn Reson Imaging. 2010;32:1287-1301.
    • (2010) J Magn Reson Imaging , vol.32 , pp. 1287-1301
    • Hopkins, S.R.1    Prisk, G.K.2
  • 33
    • 78649646574 scopus 로고    scopus 로고
    • Multimodality molecular imaging of the lung
    • Chen DL, Kinahan PE. Multimodality molecular imaging of the lung. J Magn Reson Imaging. 2010;32:1409-1420.
    • (2010) J Magn Reson Imaging , vol.32 , pp. 1409-1420
    • Chen, D.L.1    Kinahan, P.E.2
  • 34
    • 77954244658 scopus 로고    scopus 로고
    • The effect of inaccurate bone attenuation coefficient and segmentation on reconstructed PET images
    • Schleyer PJ, Schaeffter T, Marsden PK. The effect of inaccurate bone attenuation coefficient and segmentation on reconstructed PET images. Nucl Med Commun. 2010;31:708-716.
    • (2010) Nucl Med Commun , vol.31 , pp. 708-716
    • Schleyer, P.J.1    Schaeffter, T.2    Marsden, P.K.3
  • 36
    • 78349261177 scopus 로고    scopus 로고
    • Ultrashort echo time (UTE) MRI of the lung: Assessment of tissue density in the lung parenchyma
    • Togao O, Tsuji R, Ohno Y, Dimitrov I, Takahashi M. Ultrashort echo time (UTE) MRI of the lung: assessment of tissue density in the lung parenchyma. Magn Reson Med. 2010;64:1491-1498.
    • (2010) Magn Reson Med , vol.64 , pp. 1491-1498
    • Togao, O.1    Tsuji, R.2    Ohno, Y.3    Dimitrov, I.4    Takahashi, M.5