메뉴 건너뛰기




Volumn 52, Issue 2, 2011, Pages 210-217

Cardiac dedicated ultrafast SPECT cameras: New designs and clinical implications

Author keywords

Camera; Cardiac; Cardiac dedicated ultrafast SPECT cameras

Indexed keywords

TETROFOSMIN TC 99M;

EID: 79851487935     PISSN: 01615505     EISSN: None     Source Type: Journal    
DOI: 10.2967/jnumed.110.081323     Document Type: Review
Times cited : (159)

References (33)
  • 1
    • 36849139664 scopus 로고
    • Scintillation camera
    • Anger HO. Scintillation camera. Rev Sci Instrum. 1958;29:27-33.
    • (1958) Rev Sci Instrum , vol.29 , pp. 27-33
    • Anger, H.O.1
  • 2
    • 0001169360 scopus 로고
    • On the determination of functions from their integrals along certain manifolds
    • in German
    • Radon J. On the determination of functions from their integrals along certain manifolds [in German]. Berichte Saechsische Akademie der Wissenschaften. 1917;29:262-277.
    • (1917) Berichte Saechsische Akademie der Wissenschaften , vol.29 , pp. 262-277
    • Radon, J.1
  • 3
    • 34547418771 scopus 로고    scopus 로고
    • Clinical results of a novel wide beam reconstruction method for shortening scan time of Tc-99m cardiac SPECT perfusion studies
    • DOI 10.1016/j.nuclcard.2007.04.022, PII S1071358107002061
    • Borges-Neto S, Pagnanelli RA, Shaw LK, et al. Clinical results of a novel wide beam reconstruction method for shortening scan time of Tc-99m cardiac SPECT perfusion studies. J Nucl Cardiol. 2007;14:555-565. (Pubitemid 47163559)
    • (2007) Journal of Nuclear Cardiology , vol.14 , Issue.4 SPEC. ISS , pp. 555-565
    • Borges-Neto, S.1    Pagnanelli, R.A.2    Shaw, L.K.3    Honeycutt, E.4    Shwartz, S.C.5    Adams, G.L.6    Coleman, R.E.7
  • 4
    • 47949091363 scopus 로고    scopus 로고
    • Ordered subset expectation maximization and wide beam reconstruction "half-time" gated myocardial perfusion SPECT functional imaging: A comparison to "full-time" filtered backprojection
    • DePuey EG, Gadraju R, Clark J, Thompson L, Anstett F, Shwartz SC. Ordered subset expectation maximization and wide beam reconstruction "half-time" gated myocardial perfusion SPECT functional imaging: a comparison to "full-time" filtered backprojection. J Nucl Cardiol. 2008;15:547-563.
    • (2008) J Nucl Cardiol , vol.15 , pp. 547-563
    • DePuey, E.G.1    Gadraju, R.2    Clark, J.3    Thompson, L.4    Anstett, F.5    Shwartz, S.C.6
  • 5
    • 70349651967 scopus 로고    scopus 로고
    • A multicenter evaluation of a new post-processing method with depth-dependent collimator resolution applied to full and half-time acquisitions with and without AC
    • Venero CV, Heller GV, Bateman TM, et al. A multicenter evaluation of a new post-processing method with depth-dependent collimator resolution applied to full and half-time acquisitions with and without AC. J Nucl Cardiol. 2009;16: 714-725.
    • (2009) J Nucl Cardiol , vol.16 , pp. 714-725
    • Venero, C.V.1    Heller, G.V.2    Bateman, T.M.3
  • 6
    • 11844304121 scopus 로고    scopus 로고
    • Analysis of a SPECT OSEM reconstruction method with 3D beam modeling and optional attenuation correction: Phantom studies
    • M10-265, 2003 IEEE Nuclear Science Symposium Conference Record - Nuclear Science Symposium, Medical Imaging Conference
    • Vija AH, Hawman EG, Engdahl JC. Analysis of a SPECT OSEM reconstruction method with 3D beam modeling and optional attenuation correction: phantom studies. Nucl Sci Symp Conf Rec. 2003;4:2662-2666. (Pubitemid 40088784)
    • (2003) IEEE Nuclear Science Symposium Conference Record , vol.4 , pp. 2662-2666
    • Vija, A.H.1    Hawman, E.G.2    Engdahl, J.C.3
  • 7
    • 68049118726 scopus 로고    scopus 로고
    • Prospective multi-center evaluation of rapid gated SPECT myocardial perfusion upright imaging
    • Maddahi J, Mendez R, Mahmarian J, et al. Prospective multi-center evaluation of rapid gated SPECT myocardial perfusion upright imaging. J Nucl Cardiol. 2009;16:351-357.
    • (2009) J Nucl Cardiol , vol.16 , pp. 351-357
    • Maddahi, J.1    Mendez, R.2    Mahmarian, J.3
  • 8
    • 70349652316 scopus 로고    scopus 로고
    • Wide beam reconstruction "quarter-time" gated myocardial perfusion SPECT functional imaging: A comparison to "full-time" ordered subset expectation maximization
    • DePuey EG, Bommireddipally S, Clark J, Thompson L, Srour Y. Wide beam reconstruction "quarter-time" gated myocardial perfusion SPECT functional imaging: a comparison to "full-time" ordered subset expectation maximization. J Nucl Cardiol. 2009;16:736-752.
    • (2009) J Nucl Cardiol , vol.16 , pp. 736-752
    • DePuey, E.G.1    Bommireddipally, S.2    Clark, J.3    Thompson, L.4    Srour, Y.5
  • 9
    • 41249099375 scopus 로고    scopus 로고
    • High-Speed Myocardial Perfusion Imaging. Initial Clinical Comparison with Conventional Dual Detector Anger Camera Imaging
    • DOI 10.1016/j.jcmg.2007.12.004, PII S1936878X08000077
    • Sharir T, Ben-Haim S, Merzon K, et al. High-speed myocardial perfusion imaging: initial clinical comparison with conventional dual detector anger camera imaging. J Am Coll Cardiol Imaging. 2008;1:156-163. (Pubitemid 351445405)
    • (2008) JACC: Cardiovascular Imaging , vol.1 , Issue.2 , pp. 156-163
    • Sharir, T.1    Ben-Haim, S.2    Merzon, K.3    Prochorov, V.4    Dickman, D.5    Ben-Haim, S.6    Berman, D.S.7
  • 10
    • 77952294334 scopus 로고    scopus 로고
    • Multicenter trial of high-speed versus conventional single-photon emission computed tomography imaging: Quantitative results of myocardial perfusion and left ventricular function
    • Sharir T, Slomka PJ, Hayes SW, et al. Multicenter trial of high-speed versus conventional single-photon emission computed tomography imaging: quantitative results of myocardial perfusion and left ventricular function. J Am Coll Cardiol. 2010;55:1965-1974.
    • (2010) J Am Coll Cardiol , vol.55 , pp. 1965-1974
    • Sharir, T.1    Slomka, P.J.2    Hayes, S.W.3
  • 11
    • 61649124737 scopus 로고    scopus 로고
    • Stress thallium-201/rest technetium-99m sequential dual isotope high-speed myocardial perfusion imaging
    • Berman DS, Kang X, Tamarappoo B, et al. Stress thallium-201/rest technetium-99m sequential dual isotope high-speed myocardial perfusion imaging. JACC Cardiovasc Imaging. 2009;2:273-282.
    • (2009) JACC Cardiovasc Imaging , vol.2 , pp. 273-282
    • Berman, D.S.1    Kang, X.2    Tamarappoo, B.3
  • 12
    • 77956185250 scopus 로고    scopus 로고
    • Simultaneous dual-radionuclide myocardial perfusion imaging with a solid-state dedicated cardiac camera
    • Ben-Haim S, Hutton BF, Van Grantberg D. Simultaneous dual-radionuclide myocardial perfusion imaging with a solid-state dedicated cardiac camera. Eur J Nucl Med Mol Imaging. 2010;37:1710-1721.
    • (2010) Eur J Nucl Med Mol Imaging , vol.37 , pp. 1710-1721
    • Ben-Haim, S.1    Hutton, B.F.2    Van Grantberg, D.3
  • 13
    • 62549137960 scopus 로고    scopus 로고
    • A new solid state ultra fast cardiac multi-detector SPECT system
    • abstract
    • Garcia EV, Tsukerman L, Keidar Z. A new solid state ultra fast cardiac multi-detector SPECT system [abstract]. J Nucl Cardiol. 2008;15(suppl):S3.
    • (2008) J Nucl Cardiol , vol.15 , Issue.SUPPL.
    • Garcia, E.V.1    Tsukerman, L.2    Keidar, Z.3
  • 14
    • 72249112561 scopus 로고    scopus 로고
    • Novel solid-state-detector dedicated cardiac camera for fast myocardial perfusion imaging: Multicenter comparison with standard dual detector cameras
    • Esteves FP, Raggi P, Folks RD, et al. Novel solid-state-detector dedicated cardiac camera for fast myocardial perfusion imaging: multicenter comparison with standard dual detector cameras. J Nucl Cardiol. 2009;16:927-934.
    • (2009) J Nucl Cardiol , vol.16 , pp. 927-934
    • Esteves, F.P.1    Raggi, P.2    Folks, R.D.3
  • 15
    • 77952095021 scopus 로고    scopus 로고
    • Ultrafast nuclear myocardial perfusion imaging on a new gamma camera with semiconductor detector technique: First clinical validation
    • Buechel RR, Herzog BA, Husmann L, et al. Ultrafast nuclear myocardial perfusion imaging on a new gamma camera with semiconductor detector technique: first clinical validation. Eur J Nucl Med Mol Imaging. 2010;37:773-778.
    • (2010) Eur J Nucl Med Mol Imaging , vol.37 , pp. 773-778
    • Buechel, R.R.1    Herzog, B.A.2    Husmann, L.3
  • 16
    • 75149152483 scopus 로고    scopus 로고
    • Nuclear myocardial perfusion imaging with a cadmium-zinc-telluride detector technique: Optimized protocol for scan time reduction
    • Herzog BA, Buechel RR, Katz R, et al. Nuclear myocardial perfusion imaging with a cadmium-zinc-telluride detector technique: optimized protocol for scan time reduction. J Nucl Med. 2010;51:46-51.
    • (2010) J Nucl Med , vol.51 , pp. 46-51
    • Herzog, B.A.1    Buechel, R.R.2    Katz, R.3
  • 17
    • 79952109566 scopus 로고    scopus 로고
    • Real-time breath-hold triggering of myocardial perfusion imaging with a novel cadmium-zinc-telluride detector gamma camera
    • Buechel RR, Pazhenkottil AP, Herzog BA, et al. Real-time breath-hold triggering of myocardial perfusion imaging with a novel cadmium-zinc-telluride detector gamma camera. Eur J Nucl Med Mol Imaging. 2010;37:1903-1908.
    • (2010) Eur J Nucl Med Mol Imaging , vol.37 , pp. 1903-1908
    • Buechel, R.R.1    Pazhenkottil, A.P.2    Herzog, B.A.3
  • 18
    • 77958503750 scopus 로고    scopus 로고
    • Ultrafast assessment of left ventricular dyssynchrony from nuclear myocardial perfusion imaging on a new highspeed gamma camera
    • Pazhenkottil AP, Buechel RR, Herzog BA, et al. Ultrafast assessment of left ventricular dyssynchrony from nuclear myocardial perfusion imaging on a new highspeed gamma camera. Eur J Nucl Med Mol Imaging. 2010;37:2086-2092.
    • (2010) Eur J Nucl Med Mol Imaging , vol.37 , pp. 2086-2092
    • Pazhenkottil, A.P.1    Buechel, R.R.2    Herzog, B.A.3
  • 19
    • 79851503326 scopus 로고    scopus 로고
    • Validation of CT attenuation correction for high-speed myocardial perfusion imaging using a novel cadmium-zinc-telluride detector technique
    • Herzog BA, Buechel RR, Husmann L, et al. Validation of CT attenuation correction for high-speed myocardial perfusion imaging using a novel cadmium-zinc-telluride detector technique. J Nucl Med. 2010;51:1539-1544.
    • (2010) J Nucl Med , vol.51 , pp. 1539-1544
    • Herzog, B.A.1    Buechel, R.R.2    Husmann, L.3
  • 20
    • 78649903646 scopus 로고    scopus 로고
    • Cardiac hybrid imaging with high-speed single-photon emission computed tomography/CT camera to detect ischaemia and coronary artery obstruction
    • Pazhenkottil AP, Husmann L, Kaufmann PA: Cardiac hybrid imaging with high-speed single-photon emission computed tomography/CT camera to detect ischaemia and coronary artery obstruction. Heart. 2010;96:2050.
    • (2010) Heart , vol.96 , pp. 2050
    • Pazhenkottil, A.P.1    Husmann, L.2    Kaufmann, P.A.3
  • 21
    • 62549160374 scopus 로고    scopus 로고
    • New trends in camera and software technology in nuclear cardiology
    • Garcia EV, Faber TL. New trends in camera and software technology in nuclear cardiology. Cardiol Clin. 2009;27:227-236.
    • (2009) Cardiol Clin , vol.27 , pp. 227-236
    • Garcia, E.V.1    Faber, T.L.2
  • 22
    • 77953323106 scopus 로고    scopus 로고
    • Phantom evaluation of a cardiac SPECT/VCT system that uses a common set of solid-state detectors for both emission and transmission scans
    • Bai C, Conwell R, Kindem J, et al. Phantom evaluation of a cardiac SPECT/VCT system that uses a common set of solid-state detectors for both emission and transmission scans. J Nucl Cardiol. 2010;17:459-469.
    • (2010) J Nucl Cardiol , vol.17 , pp. 459-469
    • Bai, C.1    Conwell, R.2    Kindem, J.3
  • 23
    • 79851473874 scopus 로고    scopus 로고
    • Clinical validation of attenuation corrected cardiac imaging with IQ-SPECT SPECT/CT
    • abstract
    • Corbett J, Meden J, Ficaro E. Clinical validation of attenuation corrected cardiac imaging with IQ-SPECT SPECT/CT [abstract]. J Nucl Med. 2010;51(suppl 2): 360P.
    • (2010) J Nucl Med , vol.51 , Issue.SUPPL. 2 , pp. 360
    • Corbett, J.1    Meden, J.2    Ficaro, E.3
  • 24
    • 79851496319 scopus 로고    scopus 로고
    • Quantification of myocardial perfusion reserve using dynamic SPECT imaging in humans
    • abstract
    • Breault C, Roth N, Slomka PJ, et al. Quantification of myocardial perfusion reserve using dynamic SPECT imaging in humans [abstract]. J Nucl Cardiol. 2010;4(suppl):733.
    • (2010) J Nucl Cardiol , vol.4 , Issue.SUPPL. , pp. 733
    • Breault, C.1    Roth, N.2    Slomka, P.J.3
  • 25
    • 41249088091 scopus 로고    scopus 로고
    • High-speed myocardial perfusion imaging: Dawn of a new era in nuclear cardiology?
    • Bonow RO. High-speed myocardial perfusion imaging: dawn of a new era in nuclear cardiology? J Am Coll Cardiol Imaging. 2008;1:164-166.
    • (2008) J Am Coll Cardiol Imaging , vol.1 , pp. 164-166
    • Bonow, R.O.1
  • 26
    • 77956358748 scopus 로고    scopus 로고
    • Recommendations for reducing radiation exposure in myocardial perfusion imaging
    • Cerqueira MD, Allman KC, Ficaro EP, et al. Recommendations for reducing radiation exposure in myocardial perfusion imaging. J Nucl Cardiol. 2010;17: 709-718.
    • (2010) J Nucl Cardiol , vol.17 , pp. 709-718
    • Cerqueira, M.D.1    Allman, K.C.2    Ficaro, E.P.3
  • 27
    • 77956949443 scopus 로고    scopus 로고
    • Single photon-emission computed tomography
    • Holly TA, Abbott BG, Al-Mallah M, et al. Single photon-emission computed tomography. J Nucl Cardiol. 2010;17:941-973.
    • (2010) J Nucl Cardiol , vol.17 , pp. 941-973
    • Holly, T.A.1    Abbott, B.G.2    Al-Mallah, M.3
  • 28
    • 51349105820 scopus 로고    scopus 로고
    • Procedure guideline for myocardial perfusion imaging 3.3
    • Strauss HW, Miller DD, Wittry MD, et al. Procedure guideline for myocardial perfusion imaging 3.3. J Nucl Med Technol. 2008;36:155-161.
    • (2008) J Nucl Med Technol , vol.36 , pp. 155-161
    • Strauss, H.W.1    Miller, D.D.2    Wittry, M.D.3
  • 29
    • 34447306296 scopus 로고    scopus 로고
    • Frequent diagnostic errors in cardiac PET/CT due to misregistration of CT attenuation and emission PET images: A definitive analysis of causes, consequences, and corrections
    • DOI 10.2967/jnumed.107.039792
    • Gould KL, Pan T, Johnson NP, et al. Frequent diagnostic errors in cardiac PET/CT due to misregistration of CT attenuation and emission PET images: a definitive analysis of causes, consequences, and corrections. J Nucl Med. 2007;48: 1112-1121. (Pubitemid 47052651)
    • (2007) Journal of Nuclear Medicine , vol.48 , Issue.7 , pp. 1112-1121
    • Gould, K.L.1    Pan, T.2    Loghin, C.3    Johnson, N.P.4    Guha, A.5    Sdringola, S.6
  • 30
    • 45849099102 scopus 로고    scopus 로고
    • Investigation of the emission-transmission misalignment artifacts on rubidium-82 cardiac PET with adenosine pharmacologic stress
    • Schuster DM, Halkar RK, Esteves FP, et al. Investigation of the emission-transmission misalignment artifacts on rubidium-82 cardiac PET with adenosine pharmacologic stress. Mol Imaging Biol. 2008;10:201-208.
    • (2008) Mol Imaging Biol , vol.10 , pp. 201-208
    • Schuster, D.M.1    Halkar, R.K.2    Esteves, F.P.3
  • 32
    • 34147101153 scopus 로고    scopus 로고
    • New technology for noninvasive evaluation of coronary artery disease
    • DOI 10.1161/CIRCULATIONAHA.106.629808, PII 0000301720070320000020
    • Di Carli MF, Hachamovich R. New technology for noninvasive evaluation of coronary artery disease. Circulation. 2007;115:1464-1480. (Pubitemid 46648384)
    • (2007) Circulation , vol.115 , Issue.11 , pp. 1464-1480
    • Di, C.M.F.1    Hachamovitch, R.2
  • 33
    • 32044440579 scopus 로고    scopus 로고
    • Should PET replace SPECT for evaluating CAD? The end of the beginning
    • DOI 10.1016/j.nuclcard.2005.12.001, PII S1071358105005842
    • Di Carli MF, Hachamovitch R. Should PET replace SPECT for evaluating CAD? The end of the beginning. J Nucl Cardiol. 2006;13:2-7. (Pubitemid 43192722)
    • (2006) Journal of Nuclear Cardiology , vol.13 , Issue.1 , pp. 2-7
    • Di, C.M.F.1    Hachamovitch, R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.