-
1
-
-
84860494889
-
Transcatheter aortic-valve replacement for inoperable severe aortic stenosis
-
Makkar RR, Fontana GP, Jilaihawi H, Kapadia S, Pichard AD, Douglas PS, Thourani VH, Babaliaros VC, Webb JG, Herrmann HC, Bavaria JE, Kodali S, Brown DL, Bowers B, Dewey TM, Svensson LG, Tuzcu M, Moses JW, Williams MR, Siegel RJ, Akin JJ, Anderson WN, Pocock S, Smith CR, Leon MB (2012) Transcatheter aortic-valve replacement for inoperable severe aortic stenosis. N Engl J Med 366:1696-1704
-
(2012)
N Engl J Med
, vol.366
, pp. 1696-1704
-
-
Makkar, R.R.1
Fontana, G.P.2
Jilaihawi, H.3
Kapadia, S.4
Pichard, A.D.5
Douglas, P.S.6
Thourani, V.H.7
Babaliaros, V.C.8
Webb, J.G.9
Herrmann, H.C.10
Bavaria, J.E.11
Kodali, S.12
Brown, D.L.13
Bowers, B.14
Dewey, T.M.15
Svensson, L.G.16
Tuzcu, M.17
Moses, J.W.18
Williams, M.R.19
Siegel, R.J.20
Akin, J.J.21
Anderson, W.N.22
Pocock, S.23
Smith, C.R.24
Leon, M.B.25
more..
-
2
-
-
84860466759
-
Two-year outcomes after transcatheter or surgical aortic-valve replacement
-
Kodali SK, Williams MR, Smith CR, Svensson LG, Webb JG, Makkar RR, Fontana GP, Dewey TM, Thourani VH, Pichard AD, Fischbein M, Szeto WY, Lim S, Greason KL, Teirstein PS, Malaisrie SC, Douglas PS, Hahn RT, Whisenant B, Zajarias A, Wang D, Akin JJ, Anderson WN, Leon MB (2012) Two-year outcomes after transcatheter or surgical aortic-valve replacement. N Engl J Med 366:1686-1695
-
(2012)
N Engl J Med
, vol.366
, pp. 1686-1695
-
-
Kodali, S.K.1
Williams, M.R.2
Smith, C.R.3
Svensson, L.G.4
Webb, J.G.5
Makkar, R.R.6
Fontana, G.P.7
Dewey, T.M.8
Thourani, V.H.9
Pichard, A.D.10
Fischbein, M.11
Szeto, W.Y.12
Lim, S.13
Greason, K.L.14
Teirstein, P.S.15
Malaisrie, S.C.16
Douglas, P.S.17
Hahn, R.T.18
Whisenant, B.19
Zajarias, A.20
Wang, D.21
Akin, J.J.22
Anderson, W.N.23
Leon, M.B.24
more..
-
3
-
-
84859883685
-
Patient selection for transcatheter aortic valve implantation: Patient risk profile and anatomical selection criteria
-
Piazza N, Lange R, Martucci G, Serruys PW (2012) Patient selection for transcatheter aortic valve implantation: patient risk profile and anatomical selection criteria. Arch Cardiovasc Dis 105:165-173
-
(2012)
Arch Cardiovasc Dis
, vol.105
, pp. 165-173
-
-
Piazza, N.1
Lange, R.2
Martucci, G.3
Serruys, P.W.4
-
4
-
-
84867283287
-
Guidelines on the management of valvular heart disease (version 2012)
-
Vahanian A, Alfieri O, Andreotti F, Antunes MJ, Baron-Esquivias G, Baumgartner H, Borger MA, Carrel TP, De Bonis M, Evangelista A, Falk V, Iung B, Lancellotti P, Pierard L, Price S, Schafers HJ, Schuler G, Stepinska J, Swedberg K, Takkenberg J, Von Oppell UO, Windecker S, Zamorano JL, Zembala M (2012) Guidelines on the management of valvular heart disease (version 2012). Eur Heart J 33:2451-2496
-
(2012)
Eur Heart J
, vol.33
, pp. 2451-2496
-
-
Vahanian, A.1
Alfieri, O.2
Andreotti, F.3
Antunes, M.J.4
Baron-Esquivias, G.5
Baumgartner, H.6
Borger, M.A.7
Carrel, T.P.8
De Bonis, M.9
Evangelista, A.10
Falk, V.11
Iung, B.12
Lancellotti, P.13
Pierard, L.14
Price, S.15
Schafers, H.J.16
Schuler, G.17
Stepinska, J.18
Swedberg, K.19
Takkenberg, J.20
Von Oppell, U.O.21
Windecker, S.22
Zamorano, J.L.23
Zembala, M.24
more..
-
5
-
-
84859479104
-
Esc working group on valvular heart disease position paper: Assessing the risk of interventions in patients with valvular heart disease
-
Rosenhek R, Iung B, Tornos P, Antunes MJ, Prendergast BD, Otto CM, Kappetein AP, Stepinska J, Kaden JJ, Naber CK, Acarturk E, Gohlke-Barwolf C (2012) Esc working group on valvular heart disease position paper: assessing the risk of interventions in patients with valvular heart disease. Eur Heart J.33:822-828, 828a, 828b
-
(2012)
Eur Heart J
, vol.33
-
-
Rosenhek, R.1
Iung, B.2
Tornos, P.3
Antunes, M.J.4
Prendergast, B.D.5
Otto, C.M.6
Kappetein, A.P.7
Stepinska, J.8
Kaden, J.J.9
Naber, C.K.10
Acarturk, E.11
Gohlke-Barwolf, C.12
-
6
-
-
79955806321
-
Risk scores for predicting outcomes in valvular heart disease: How useful?
-
Mack MJ (2011) Risk scores for predicting outcomes in valvular heart disease: How useful? Curr Cardiol Rep 13:107-112
-
(2011)
Curr Cardiol Rep
, vol.13
, pp. 107-112
-
-
Mack, M.J.1
-
7
-
-
84859567725
-
A practical guide to multimodality imaging of transcatheter aortic valve replacement
-
Bloomfield GS, Gillam LD, Hahn RT, Kapadia S, Leipsic J, Lerakis S, Tuzcu M, Douglas PS (2012) A practical guide to multimodality imaging of transcatheter aortic valve replacement. JACC Cardiovasc Imaging 5:441-455
-
(2012)
JACC Cardiovasc Imaging
, vol.5
, pp. 441-455
-
-
Bloomfield, G.S.1
Gillam, L.D.2
Hahn, R.T.3
Kapadia, S.4
Leipsic, J.5
Lerakis, S.6
Tuzcu, M.7
Douglas, P.S.8
-
8
-
-
62949095752
-
Anatomy of the aortic valvar complex and its implications for transcatheter implantation of the aortic valve
-
Piazza N, de Jaegere P, Schultz C, Becker AE, Serruys PW, Anderson RH (2008) Anatomy of the aortic valvar complex and its implications for transcatheter implantation of the aortic valve. Circ Cardiovasc Interv 1:74-81
-
(2008)
Circ Cardiovasc Interv
, vol.1
, pp. 74-81
-
-
Piazza, N.1
De Jaegere, P.2
Schultz, C.3
Becker, A.E.4
Serruys, P.W.5
Anderson, R.H.6
-
9
-
-
84866367272
-
Transcatheter aortic valve implantation: A Canadian Cardiovascular Society position statement
-
Webb J, Rodes-Cabau J, Fremes S, Pibarot P, Ruel M, Ibrahim R, Welsh R, Feindel C, Lichtenstein S (2012) Transcatheter aortic valve implantation: a Canadian Cardiovascular Society position statement. Can J Cardiol 28:520-528
-
(2012)
Can J Cardiol
, vol.28
, pp. 520-528
-
-
Webb, J.1
Rodes-Cabau, J.2
Fremes, S.3
Pibarot, P.4
Ruel, M.5
Ibrahim, R.6
Welsh, R.7
Feindel, C.8
Lichtenstein, S.9
-
10
-
-
84872685837
-
5-year outcome after transcatheter aortic valve implantation
-
Toggweiler S, Humphries KH, Lee M, Binder RK, Moss RR, Freeman M, Ye J, Cheung A, Wood DA, Webb JG (2013) 5-year outcome after transcatheter aortic valve implantation. J Am Coll Cardiol 61:413-419
-
(2013)
J Am Coll Cardiol
, vol.61
, pp. 413-419
-
-
Toggweiler, S.1
Humphries, K.H.2
Lee, M.3
Binder, R.K.4
Moss, R.R.5
Freeman, M.6
Ye, J.7
Cheung, A.8
Wood, D.A.9
Webb, J.G.10
-
11
-
-
0032801163
-
European system for cardiac operative risk evaluation (EuroSCORE)
-
DOI 10.1016/S1010-7940(99)00134-7, PII S1010794099001347
-
Nashef SA, Roques F, Michel P, Gauducheau E, Lemeshow S, Salamon R (1999) European system for cardiac operative risk evaluation (euroscore). Eur J Cardio-Thorac Surg Off J Eur Assoc Cardio-Thorac Surg 16:9-13 (Pubitemid 29336425)
-
(1999)
European Journal of Cardio-thoracic Surgery
, vol.16
, Issue.1
, pp. 9-13
-
-
Nashef, S.A.M.1
Roques, F.2
Michel, P.3
Gauducheau, E.4
Lemeshow, S.5
Salamon, R.6
-
13
-
-
67649816665
-
The society of thoracic surgeons 2008 cardiac surgery risk models part 2: Isolated valve surgery
-
O'Brien SM, Shahian DM, Filardo G, Ferraris VA, Haan CK, Rich JB, Normand SL, DeLong ER, Shewan CM, Dokholyan RS, Peterson ED, Edwards FH, Anderson RP (2009) The society of thoracic surgeons 2008 cardiac surgery risk models part 2: isolated valve surgery. Ann Thorac Surg 88:S23-S42
-
(2009)
Ann Thorac Surg
, vol.88
-
-
O'Brien, S.M.1
Shahian, D.M.2
Filardo, G.3
Ferraris, V.A.4
Haan, C.K.5
Rich, J.B.6
Normand, S.L.7
DeLong, E.R.8
Shewan, C.M.9
Dokholyan, R.S.10
Peterson, E.D.11
Edwards, F.H.12
Anderson, R.P.13
-
14
-
-
84861498351
-
Euroscore ii
-
discussion 744-735
-
Nashef SA, Roques F, Sharples LD, Nilsson J, Smith C, Goldstone AR, Lockowandt U (2012) Euroscore ii. Eur J Cardio-Thorac Surg Off J Eur Assoc Cardio-Thorac Surg 41:734-744 discussion 744-735
-
(2012)
Eur J Cardio-Thorac Surg off J Eur Assoc Cardio-Thorac Surg
, vol.41
, pp. 734-744
-
-
Nashef, S.A.1
Roques, F.2
Sharples, L.D.3
Nilsson, J.4
Smith, C.5
Goldstone, A.R.6
Lockowandt, U.7
-
15
-
-
22144443823
-
Generic, simple risk stratification model for heart valve surgery
-
DOI 10.1161/CIRCULATIONAHA.104.515049
-
Ambler G, Omar RZ, Royston P, Kinsman R, Keogh BE, Taylor KM (2005) Generic, simple risk stratification model for heart valve surgery. Circulation 112:224-231 (Pubitemid 40982305)
-
(2005)
Circulation
, vol.112
, Issue.2
, pp. 224-231
-
-
Ambler, G.1
Omar, R.Z.2
Royston, P.3
Kinsman, R.4
Keogh, B.E.5
Taylor, K.M.6
-
16
-
-
84876849595
-
German aortic valve score: A new scoring system for prediction of mortality related to aortic valve procedures in adults
-
Kotting J, Schiller W, Beckmann A, Schafer E, Dobler K, Hamm C, Veit C, Welz A (2013) German aortic valve score: a new scoring system for prediction of mortality related to aortic valve procedures in adults. Eur J Cardio-Thorac Surg Off J Eur Assoc Cardio-Thorac Surg 43:971-977
-
(2013)
Eur J Cardio-Thorac Surg off J Eur Assoc Cardio-Thorac Surg
, vol.43
, pp. 971-977
-
-
Kotting, J.1
Schiller, W.2
Beckmann, A.3
Schafer, E.4
Dobler, K.5
Hamm, C.6
Veit, C.7
Welz, A.8
-
17
-
-
2542469557
-
Multivariable prediction of in-hospital mortality associated with aortic and mitral valve surgery in Northern New England
-
DOI 10.1016/j.athoracsur.2003.12.035, PII S0003497504001158
-
Nowicki ER, Birkmeyer NJ, Weintraub RW, Leavitt BJ, Sanders JH, Dacey LJ, Clough RA, Quinn RD, Charlesworth DC, Sisto DA, Uhlig PN, Olmstead EM, O'Connor GT (2004) Multivariable prediction of in-hospital mortality associated with aortic and mitral valve surgery in northern New England. Ann Thorac Surg 77:1966-1977 (Pubitemid 38686568)
-
(2004)
Annals of Thoracic Surgery
, vol.77
, Issue.6
, pp. 1966-1977
-
-
Nowicki, E.R.1
Birkmeyer, N.J.O.2
Weintraub, R.W.3
Leavitt, B.J.4
Sanders, J.H.5
Dacey, L.J.6
Clough, R.A.7
Quinn, R.D.8
Charlesworth, D.C.9
Sisto, D.A.10
Uhlig, P.N.11
Olmstead, E.M.12
O'Connor, G.T.13
-
18
-
-
33847263945
-
Risk Index for Predicting In-Hospital Mortality for Cardiac Valve Surgery
-
DOI 10.1016/j.athoracsur.2006.09.051, PII S0003497506018753
-
Hannan EL, Wu C, Bennett EV, Carlson RE, Culliford AT, Gold JP, Higgins RS, Smith CR, Jones RH (2007) Risk index for predicting in-hospital mortality for cardiac valve surgery. Ann Thorac Surg 83:921-929 (Pubitemid 46328805)
-
(2007)
Annals of Thoracic Surgery
, vol.83
, Issue.3
, pp. 921-929
-
-
Hannan, E.L.1
Wu, C.2
Bennett, E.V.3
Carlson, R.E.4
Culliford, A.T.5
Gold, J.P.6
Higgins, R.S.D.7
Smith, C.R.8
Jones, R.H.9
-
19
-
-
22544479420
-
Validation and refinement of mortality risk models for heart valve surgery
-
DOI 10.1016/j.athoracsur.2005.02.066, PII S0003497505003346
-
Jin R, Grunkemeier GL, Starr A (2005) Validation and refinement of mortality risk models for heart valve surgery. Ann Thorac Surg 80:471-479 (Pubitemid 41019464)
-
(2005)
Annals of Thoracic Surgery
, vol.80
, Issue.2
, pp. 471-479
-
-
Jin, R.1
Grunkemeier, G.L.2
Starr, A.3
-
20
-
-
79958204372
-
Transcatheter versus surgical aortic-valve replacement in high-risk patients
-
Smith CR, Leon MB, Mack MJ, Miller DC, Moses JW, Svensson LG, Tuzcu EM, Webb JG, Fontana GP, Makkar RR, Williams M, Dewey T, Kapadia S, Babaliaros V, Thourani VH, Corso P, Pichard AD, Bavaria JE, Herrmann HC, Akin JJ, Anderson WN, Wang D, Pocock SJ (2011) Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Engl J Med 364:2187-2198
-
(2011)
N Engl J Med
, vol.364
, pp. 2187-2198
-
-
Smith, C.R.1
Leon, M.B.2
Mack, M.J.3
Miller, D.C.4
Moses, J.W.5
Svensson, L.G.6
Tuzcu, E.M.7
Webb, J.G.8
Fontana, G.P.9
Makkar, R.R.10
Williams, M.11
Dewey, T.12
Kapadia, S.13
Babaliaros, V.14
Thourani, V.H.15
Corso, P.16
Pichard, A.D.17
Bavaria, J.E.18
Herrmann, H.C.19
Akin, J.J.20
Anderson, W.N.21
Wang, D.22
Pocock, S.J.23
more..
-
21
-
-
84875453727
-
Performance analysis of euroscore ii compared to the original logistic euroscore and sts scores for predicting 30-day mortality after transcatheter aortic valve replacement
-
Durand E, Borz B, Godin M, Tron C, Litzler PY, Bessou JP, Dacher JN, Bauer F, Cribier A, Eltchaninoff H (2013) Performance analysis of euroscore ii compared to the original logistic euroscore and sts scores for predicting 30-day mortality after transcatheter aortic valve replacement. Am J Cardiol 111:891-897
-
(2013)
Am J Cardiol
, vol.111
, pp. 891-897
-
-
Durand, E.1
Borz, B.2
Godin, M.3
Tron, C.4
Litzler, P.Y.5
Bessou, J.P.6
Dacher, J.N.7
Bauer, F.8
Cribier, A.9
Eltchaninoff, H.10
-
22
-
-
84886407504
-
The revised euroscore ii for the prediction of mortality in patients undergoing transcatheter aortic valve implantation
-
Sedaghat A, Sinning JM, Vasa-Nicotera M, Ghanem A, Hammerstingl C, Grube E, Nickenig G, Werner N (2013) The revised euroscore ii for the prediction of mortality in patients undergoing transcatheter aortic valve implantation. Clin Res Cardiol Off J Ger Cardiac Soc
-
(2013)
Clin Res Cardiol off J Ger Cardiac Soc
-
-
Sedaghat, A.1
Sinning, J.M.2
Vasa-Nicotera, M.3
Ghanem, A.4
Hammerstingl, C.5
Grube, E.6
Nickenig, G.7
Werner, N.8
-
23
-
-
84860389030
-
Transfemoral aortic valve implantation new criteria to predict vascular complications
-
Hayashida K, Lefevre T, Chevalier B, Hovasse T, Romano M, Garot P, Mylotte D, Uribe J, Farge A, Donzeau-Gouge P, Bouvier E, Cormier B, Morice MC (2011) Transfemoral aortic valve implantation new criteria to predict vascular complications. JACC Cardiovasc Interv 4:851-858
-
(2011)
JACC Cardiovasc Interv
, vol.4
, pp. 851-858
-
-
Hayashida, K.1
Lefevre, T.2
Chevalier, B.3
Hovasse, T.4
Romano, M.5
Garot, P.6
Mylotte, D.7
Uribe, J.8
Farge, A.9
Donzeau-Gouge, P.10
Bouvier, E.11
Cormier, B.12
Morice, M.C.13
-
24
-
-
84855403379
-
Percutaneous aortic valve replacement: Vascular outcomes with a fully percutaneous procedure
-
Toggweiler S, Gurvitch R, Leipsic J, Wood DA, Willson AB, Binder RK, Cheung A, Ye J, Webb JG (2012) Percutaneous aortic valve replacement: vascular outcomes with a fully percutaneous procedure. J Am Coll Cardiol 59:113-118
-
(2012)
J Am Coll Cardiol
, vol.59
, pp. 113-118
-
-
Toggweiler, S.1
Gurvitch, R.2
Leipsic, J.3
Wood, D.A.4
Willson, A.B.5
Binder, R.K.6
Cheung, A.7
Ye, J.8
Webb, J.G.9
-
25
-
-
77950503224
-
Aorto-iliac angiography as a screening tool in selecting patients for transfemoral aortic valve implantation with the edwards sapien bioprosthesis
-
Eltchaninoff H, Kerkeni M, Zajarias A, Tron C, Godin M, Sanchez Giron C, Baala B, Cribier A (2009) Aorto-iliac angiography as a screening tool in selecting patients for transfemoral aortic valve implantation with the edwards sapien bioprosthesis. Euro-Interv J EuroPCR Collab Work Gr Interv Cardiol Eur Soc Cardiol 5:438-442
-
(2009)
Euro-Interv J EuroPCR Collab Work Gr Interv Cardiol Eur Soc Cardiol
, vol.5
, pp. 438-442
-
-
Eltchaninoff, H.1
Kerkeni, M.2
Zajarias, A.3
Tron, C.4
Godin, M.5
Sanchez Giron, C.6
Baala, B.7
Cribier, A.8
-
26
-
-
84870743337
-
Scct expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (tavi)/transcatheter aortic valve replacement (tavr)
-
Achenbach S, Delgado V, Hausleiter J, Schoenhagen P, Min JK, Leipsic JA (2012) Scct expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (tavi)/transcatheter aortic valve replacement (tavr). J Cardiovasc Comput Tomogr 6:366-380
-
(2012)
J Cardiovasc Comput Tomogr
, vol.6
, pp. 366-380
-
-
Achenbach, S.1
Delgado, V.2
Hausleiter, J.3
Schoenhagen, P.4
Min, J.K.5
Leipsic, J.A.6
-
28
-
-
78651293118
-
Anatomical suitability for transcatheter aortic valve implantation with complementary roles for 2 rivals
-
Wenaweser P, Windecker S (2010) Anatomical suitability for transcatheter aortic valve implantation with complementary roles for 2 rivals. JACC Cardiovasc Interv 3:867-869
-
(2010)
JACC Cardiovasc Interv
, vol.3
, pp. 867-869
-
-
Wenaweser, P.1
Windecker, S.2
-
29
-
-
84881330796
-
Standardized imaging for aortic annular sizing: Implications for transcatheter valve selection
-
Kasel AM, Cassese S, Bleiziffer S, Amaki M, Hahn RT, Kastrati A, Sengupta PP (2013) Standardized imaging for aortic annular sizing: implications for transcatheter valve selection. JACC Cardiovasc Imaging 6:249-262
-
(2013)
JACC Cardiovasc Imaging
, vol.6
, pp. 249-262
-
-
Kasel, A.M.1
Cassese, S.2
Bleiziffer, S.3
Amaki, M.4
Hahn, R.T.5
Kastrati, A.6
Sengupta, P.P.7
-
30
-
-
84880355851
-
Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement
-
Barbanti M, Yang TH, Rodes Cabau J, Tamburino C, Wood DA, Jilaihawi H, Blanke P, Makkar RR, Latib A, Colombo A, Tarantini G, Raju R, Binder RK, Nguyen G, Freeman M, Ribeiro HB, Kapadia S, Min J, Feuchtner G, Gurtvich R, Alqoofi F, Pelletier M, Ussia GP, Napodano M, De Brito FS Jr, Kodali S, Norgaard BL, Hansson NC, Pache G, Canovas SJ, Zhang H, Leon MB, Webb JG, Leipsic J (2013) Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement. Circulation 128:244-253
-
(2013)
Circulation
, vol.128
, pp. 244-253
-
-
Barbanti, M.1
Yang, T.H.2
Rodes Cabau, J.3
Tamburino, C.4
Wood, D.A.5
Jilaihawi, H.6
Blanke, P.7
Makkar, R.R.8
Latib, A.9
Colombo, A.10
Tarantini, G.11
Raju, R.12
Binder, R.K.13
Nguyen, G.14
Freeman, M.15
Ribeiro, H.B.16
Kapadia, S.17
Min, J.18
Feuchtner, G.19
Gurtvich, R.20
Alqoofi, F.21
Pelletier, M.22
Ussia, G.P.23
Napodano, M.24
De Brito Jr., F.S.25
Kodali, S.26
Norgaard, B.L.27
Hansson, N.C.28
Pache, G.29
Canovas, S.J.30
Zhang, H.31
Leon, M.B.32
Webb, J.G.33
Leipsic, J.34
more..
-
31
-
-
80052572953
-
Eae/ase recommendations for the use of echocardiography in new transcatheter interventions for valvular heart disease
-
Zamorano JL, Badano LP, Bruce C, Chan KL, Goncalves A, Hahn RT, Keane MG, La Canna G, Monaghan MJ, Nihoyannopoulos P, Silvestry FE, Vanoverschelde JL, Gillam LD (2011) Eae/ase recommendations for the use of echocardiography in new transcatheter interventions for valvular heart disease. Eur Heart J 32:2189-2214
-
(2011)
Eur Heart J
, vol.32
, pp. 2189-2214
-
-
Zamorano, J.L.1
Badano, L.P.2
Bruce, C.3
Chan, K.L.4
Goncalves, A.5
Hahn, R.T.6
Keane, M.G.7
La Canna, G.8
Monaghan, M.J.9
Nihoyannopoulos, P.10
Silvestry, F.E.11
Vanoverschelde, J.L.12
Gillam, L.D.13
-
32
-
-
84872807244
-
Aortic root dimensions among patients with severe aortic stenosis undergoing transcatheter aortic valve replacement
-
Buellesfeld L, Stortecky S, Kalesan B, Gloekler S, Khattab AA, Nietlispach F, Delfine V, Huber C, Eberle B, Meier B, Wenaweser P, Windecker S (2013) Aortic root dimensions among patients with severe aortic stenosis undergoing transcatheter aortic valve replacement. JACC Cardiovasc Interv 6:72-83
-
(2013)
JACC Cardiovasc Interv
, vol.6
, pp. 72-83
-
-
Buellesfeld, L.1
Stortecky, S.2
Kalesan, B.3
Gloekler, S.4
Khattab, A.A.5
Nietlispach, F.6
Delfine, V.7
Huber, C.8
Eberle, B.9
Meier, B.10
Wenaweser, P.11
Windecker, S.12
-
33
-
-
77950501005
-
Three dimensional evaluation of the aortic annulus using multislice computer tomography: Are manufacturer's guidelines for sizing for percutaneous aortic valve replacement helpful?
-
Schultz CJ, Moelker A, Piazza N, Tzikas A, Otten A, Nuis RJ, Neefjes LA, van Geuns RJ, de Feyter P, Krestin G, Serruys PW, de Jaegere PP (2010) Three dimensional evaluation of the aortic annulus using multislice computer tomography: are manufacturer's guidelines for sizing for percutaneous aortic valve replacement helpful? Eur Heart J 31:849-856
-
(2010)
Eur Heart J
, vol.31
, pp. 849-856
-
-
Schultz, C.J.1
Moelker, A.2
Piazza, N.3
Tzikas, A.4
Otten, A.5
Nuis, R.J.6
Neefjes, L.A.7
Van Geuns, R.J.8
De Feyter, P.9
Krestin, G.10
Serruys, P.W.11
De Jaegere, P.P.12
-
34
-
-
81855227692
-
Aortic annulus diameter determination by multidetector computed tomography: Reproducibility, applicability, and implications for transcatheter aortic valve implantation
-
Gurvitch R, Webb JG, Yuan R, Johnson M, Hague C, Willson AB, Toggweiler S, Wood DA, Ye J, Moss R, Thompson CR, Achenbach S, Min JK, Labounty TM, Cury R, Leipsic J (2011) Aortic annulus diameter determination by multidetector computed tomography: reproducibility, applicability, and implications for transcatheter aortic valve implantation. JACC Cardiovasc Interv 4:1235-1245
-
(2011)
JACC Cardiovasc Interv
, vol.4
, pp. 1235-1245
-
-
Gurvitch, R.1
Webb, J.G.2
Yuan, R.3
Johnson, M.4
Hague, C.5
Willson, A.B.6
Toggweiler, S.7
Wood, D.A.8
Ye, J.9
Moss, R.10
Thompson, C.R.11
Achenbach, S.12
Min, J.K.13
Labounty, T.M.14
Cury, R.15
Leipsic, J.16
-
35
-
-
84859164235
-
Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of paravalvular aortic regurgitation
-
Jilaihawi H, Kashif M, Fontana G, Furugen A, Shiota T, Friede G, Makhija R, Doctor N, Leon MB, Makkar RR (2012) Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of paravalvular aortic regurgitation. J Am Coll Cardiol 59:1275-1286
-
(2012)
J Am Coll Cardiol
, vol.59
, pp. 1275-1286
-
-
Jilaihawi, H.1
Kashif, M.2
Fontana, G.3
Furugen, A.4
Shiota, T.5
Friede, G.6
Makhija, R.7
Doctor, N.8
Leon, M.B.9
Makkar, R.R.10
-
36
-
-
84865791990
-
Chronic kidney disease is not associated with a higher risk for mortality or acute kidney injury in transcatheter aortic valve implantation
-
Wessely M, Rau S, Lange P, Kehl K, Renz V, Schonermarck U, Steinbeck G, Fischereder M, Boekstegers P (2012) Chronic kidney disease is not associated with a higher risk for mortality or acute kidney injury in transcatheter aortic valve implantation. Nephrol Dial Transplantat Off Publ Eur Dial Transpl Assoc Eur Renal Assoc 27:3502-3508
-
(2012)
Nephrol Dial Transplantat off Publ Eur Dial Transpl Assoc Eur Renal Assoc
, vol.27
, pp. 3502-3508
-
-
Wessely, M.1
Rau, S.2
Lange, P.3
Kehl, K.4
Renz, V.5
Schonermarck, U.6
Steinbeck, G.7
Fischereder, M.8
Boekstegers, P.9
-
37
-
-
84859160648
-
3-dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement: A multicenter retrospective analysis
-
Willson AB, Webb JG, Labounty TM, Achenbach S, Moss R, Wheeler M, Thompson C, Min JK, Gurvitch R, Norgaard BL, Hague CJ, Toggweiler S, Binder R, Freeman M, Poulter R, Poulsen S, Wood DA, Leipsic J (2012) 3-dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement: a multicenter retrospective analysis. J Am Coll Cardiol 59:1287-1294
-
(2012)
J Am Coll Cardiol
, vol.59
, pp. 1287-1294
-
-
Willson, A.B.1
Webb, J.G.2
Labounty, T.M.3
Achenbach, S.4
Moss, R.5
Wheeler, M.6
Thompson, C.7
Min, J.K.8
Gurvitch, R.9
Norgaard, B.L.10
Hague, C.J.11
Toggweiler, S.12
Binder, R.13
Freeman, M.14
Poulter, R.15
Poulsen, S.16
Wood, D.A.17
Leipsic, J.18
-
38
-
-
84880614039
-
The impact of integration of a multidetector computed tomography annulus area sizing algorithm on outcomes of transcatheter aortic valve replacement: A prospective, multicenter, controlled trial
-
Binder RK, Webb JG, Willson AB, Urena M, Hansson NC, Norgaard BL, Pibarot P, Barbanti M, Larose E, Freeman M, Dumont E, Thompson C, Wheeler M, Moss RR, Yang TH, Pasian S, Hague CJ, Nguyen G, Raju R, Toggweiler S, Min JK, Wood DA, Rodes-Cabau J, Leipsic J (2013) The impact of integration of a multidetector computed tomography annulus area sizing algorithm on outcomes of transcatheter aortic valve replacement: a prospective, multicenter, controlled trial. J Am Coll Cardiol 62:431-438
-
(2013)
J Am Coll Cardiol
, vol.62
, pp. 431-438
-
-
Binder, R.K.1
Webb, J.G.2
Willson, A.B.3
Urena, M.4
Hansson, N.C.5
Norgaard, B.L.6
Pibarot, P.7
Barbanti, M.8
Larose, E.9
Freeman, M.10
Dumont, E.11
Thompson, C.12
Wheeler, M.13
Moss, R.R.14
Yang, T.H.15
Pasian, S.16
Hague, C.J.17
Nguyen, G.18
Raju, R.19
Toggweiler, S.20
Min, J.K.21
Wood, D.A.22
Rodes-Cabau, J.23
Leipsic, J.24
more..
-
39
-
-
84855403987
-
Deformation dynamics and mechanical properties of the aortic annulus by 4-dimensional computed tomography: Insights into the functional anatomy of the aortic valve complex and implications for transcatheter aortic valve therapy
-
Hamdan A, Guetta V, Konen E, Goitein O, Segev A, Raanani E, Spiegelstein D, Hay I, Di Segni E, Eldar M, Schwammenthal E (2012) Deformation dynamics and mechanical properties of the aortic annulus by 4-dimensional computed tomography: insights into the functional anatomy of the aortic valve complex and implications for transcatheter aortic valve therapy. J Am Coll Cardiol 59:119-127
-
(2012)
J Am Coll Cardiol
, vol.59
, pp. 119-127
-
-
Hamdan, A.1
Guetta, V.2
Konen, E.3
Goitein, O.4
Segev, A.5
Raanani, E.6
Spiegelstein, D.7
Hay, I.8
Di Segni, E.9
Eldar, M.10
Schwammenthal, E.11
-
40
-
-
84884479213
-
Implications of bicuspid aortic valves for transcatheter aortic valve implantation
-
O'Sullivan CJ, Windecker S (2013) Implications of bicuspid aortic valves for transcatheter aortic valve implantation. Circ Cardiovasc Interv 6:204-206
-
(2013)
Circ Cardiovasc Interv
, vol.6
, pp. 204-206
-
-
O'Sullivan, C.J.1
Windecker, S.2
-
41
-
-
84877102732
-
Paravalvular leak after transcatheter aortic valve replacement: The new achilles' heel? A comprehensive review of the literature
-
Genereux P, Head SJ, Hahn R, Daneault B, Kodali S, Williams MR, van Mieghem NM, Alu MC, Serruys PW, Kappetein AP, Leon MB (2013) Paravalvular leak after transcatheter aortic valve replacement: the new achilles' heel? A comprehensive review of the literature. J Am Coll Cardiol 61:1125-1136
-
(2013)
J Am Coll Cardiol
, vol.61
, pp. 1125-1136
-
-
Genereux, P.1
Head, S.J.2
Hahn, R.3
Daneault, B.4
Kodali, S.5
Williams, M.R.6
Van Mieghem, N.M.7
Alu, M.C.8
Serruys, P.W.9
Kappetein, A.P.10
Leon, M.B.11
-
42
-
-
82955169607
-
Transcatheter aortic valve implantation: Current principles of patient and technique selection and future perspectives
-
Al-Lamee R, Godino C, Colombo A (2011) Transcatheter aortic valve implantation: current principles of patient and technique selection and future perspectives. Circu Cardiovasc Interv 4:387-395
-
(2011)
Circu Cardiovasc Interv
, vol.4
, pp. 387-395
-
-
Al-Lamee, R.1
Godino, C.2
Colombo, A.3
-
43
-
-
84879370254
-
Severe aortic stenosis and coronary artery disease-implications for management in the transcatheter aortic valve replacement era: A comprehensive review
-
Goel SS, Ige M, Tuzcu EM, Ellis SG, Stewart WJ, Svensson LG, Lytle BW, Kapadia SR (2013) Severe aortic stenosis and coronary artery disease-implications for management in the transcatheter aortic valve replacement era: a comprehensive review. J Am Coll Cardiol 62:1-10
-
(2013)
J Am Coll Cardiol
, vol.62
, pp. 1-10
-
-
Goel, S.S.1
Ige, M.2
Tuzcu, E.M.3
Ellis, S.G.4
Stewart, W.J.5
Svensson, L.G.6
Lytle, B.W.7
Kapadia, S.R.8
-
44
-
-
80055119455
-
Impact of coronary artery disease and percutaneous coronary intervention on outcomes in patients with severe aortic stenosis undergoing transcatheter aortic valve implantation
-
Wenaweser P, Pilgrim T, Guerios E, Stortecky S, Huber C, Khattab AA, Kadner A, Buellesfeld L, Gloekler S, Meier B, Carrel T, Windecker S (2011) Impact of coronary artery disease and percutaneous coronary intervention on outcomes in patients with severe aortic stenosis undergoing transcatheter aortic valve implantation. EuroInterv J EuroPCR Collab Work Gr Interv Cardiol Eur Soc Cardiol 7:541-548
-
(2011)
EuroInterv J EuroPCR Collab Work Gr Interv Cardiol Eur Soc Cardiol
, vol.7
, pp. 541-548
-
-
Wenaweser, P.1
Pilgrim, T.2
Guerios, E.3
Stortecky, S.4
Huber, C.5
Khattab, A.A.6
Kadner, A.7
Buellesfeld, L.8
Gloekler, S.9
Meier, B.10
Carrel, T.11
Windecker, S.12
-
45
-
-
80755176825
-
Clinical outcome of high-risk patients with severe aortic stenosis and reduced left ventricular ejection fraction undergoing medical treatment or tavi
-
Pilgrim T, Wenaweser P, Meuli F, Huber C, Stortecky S, Seiler C, Zbinden S, Meier B, Carrel T, Windecker S (2011) Clinical outcome of high-risk patients with severe aortic stenosis and reduced left ventricular ejection fraction undergoing medical treatment or tavi. PLoS One 6:e27556
-
(2011)
PLoS One
, vol.6
-
-
Pilgrim, T.1
Wenaweser, P.2
Meuli, F.3
Huber, C.4
Stortecky, S.5
Seiler, C.6
Zbinden, S.7
Meier, B.8
Carrel, T.9
Windecker, S.10
-
46
-
-
0030921467
-
Aortic valve replacement for aortic stenosis with severe left ventricular dysfunction: Prognostic indicators
-
Connolly HM, Oh JK, Orszulak TA, Osborn SL, Roger VL, Hodge DO, Bailey KR, Seward JB, Tajik AJ (1997) Aortic valve replacement for aortic stenosis with severe left ventricular dysfunction. Progn Indic Circ 95:2395-2400 (Pubitemid 27224734)
-
(1997)
Circulation
, vol.95
, Issue.10
, pp. 2395-2400
-
-
Connolly, H.M.1
Oh, J.K.2
Orszulak, T.A.3
Osborn, S.L.4
Roger, V.L.5
Hodge, D.O.6
Bailey, K.R.7
Seward, J.B.8
Tajik, A.J.9
-
47
-
-
84868197706
-
Low-flow, low-gradient aortic stenosis with normal and depressed left ventricular ejection fraction
-
Pibarot P, Dumesnil JG (2012) Low-flow, low-gradient aortic stenosis with normal and depressed left ventricular ejection fraction. J Am Coll Cardiol 60:1845-1853
-
(2012)
J Am Coll Cardiol
, vol.60
, pp. 1845-1853
-
-
Pibarot, P.1
Dumesnil, J.G.2
-
48
-
-
65549091065
-
Outcome after aortic valve replacement for low-flow/low-gradient aortic stenosis without contractile reserve on dobutamine stress echocardiography
-
Tribouilloy C, Levy F, Rusinaru D, Gueret P, Petit-Eisenmann H, Baleynaud S, Jobic Y, Adams C, Lelong B, Pasquet A, Chauvel C, Metz D, Quere JP, Monin JL (2009) Outcome after aortic valve replacement for low-flow/low-gradient aortic stenosis without contractile reserve on dobutamine stress echocardiography. J Am Coll Cardiol 53:1865-1873
-
(2009)
J Am Coll Cardiol
, vol.53
, pp. 1865-1873
-
-
Tribouilloy, C.1
Levy, F.2
Rusinaru, D.3
Gueret, P.4
Petit-Eisenmann, H.5
Baleynaud, S.6
Jobic, Y.7
Adams, C.8
Lelong, B.9
Pasquet, A.10
Chauvel, C.11
Metz, D.12
Quere, J.P.13
Monin, J.L.14
-
49
-
-
84878924763
-
Predictors of mortality and outcomes of therapy in low-flow severe aortic stenosis: A placement of aortic transcatheter valves (partner) trial analysis
-
Herrmann HC, Pibarot P, Hueter I, Gertz ZM, Stewart WJ, Kapadia S, Tuzcu EM, Babaliaros V, Thourani V, Szeto WY, Bavaria JE, Kodali S, Hahn RT, Williams M, Miller DC, Douglas PS, Leon MB (2013) Predictors of mortality and outcomes of therapy in low-flow severe aortic stenosis: a placement of aortic transcatheter valves (partner) trial analysis. Circulation 127:2316-2326
-
(2013)
Circulation
, vol.127
, pp. 2316-2326
-
-
Herrmann, H.C.1
Pibarot, P.2
Hueter, I.3
Gertz, Z.M.4
Stewart, W.J.5
Kapadia, S.6
Tuzcu, E.M.7
Babaliaros, V.8
Thourani, V.9
Szeto, W.Y.10
Bavaria, J.E.11
Kodali, S.12
Hahn, R.T.13
Williams, M.14
Miller, D.C.15
Douglas, P.S.16
Leon, M.B.17
-
50
-
-
84890500394
-
Clinical outcomes of patients with low-flow, low-gradient, severe aortic stenosis and either preserved or reduced ejection fraction undergoing transcatheter aortic valve implantation
-
O'Sullivan CJ, Stortecky S, Heg D, Pilgrim T, Hosek N, Buellesfeld L, Khattab AA, Nietlispach F, Moschovitis A, Zanchin T, Meier B, Windecker S, Wenaweser P (2013) Clinical outcomes of patients with low-flow, low-gradient, severe aortic stenosis and either preserved or reduced ejection fraction undergoing transcatheter aortic valve implantation. Eur Heart J 34:3437-3450
-
(2013)
Eur Heart J
, vol.34
, pp. 3437-3450
-
-
O'Sullivan, C.J.1
Stortecky, S.2
Heg, D.3
Pilgrim, T.4
Hosek, N.5
Buellesfeld, L.6
Khattab, A.A.7
Nietlispach, F.8
Moschovitis, A.9
Zanchin, T.10
Meier, B.11
Windecker, S.12
Wenaweser, P.13
-
51
-
-
34249868221
-
Paradoxical low-flow, low-gradient severe aortic stenosis despite preserved ejection fraction is associated with higher afterload and reduced survival
-
DOI 10.1161/CIRCULATIONAHA.106.668681
-
Hachicha Z, Dumesnil JG, Bogaty P, Pibarot P (2007) Paradoxical low-flow, low-gradient severe aortic stenosis despite preserved ejection fraction is associated with higher afterload and reduced survival. Circulation 115:2856-2864 (Pubitemid 46869673)
-
(2007)
Circulation
, vol.115
, Issue.22
, pp. 2856-2864
-
-
Hachicha, Z.1
Dumesnil, J.G.2
Bogaty, P.3
Pibarot, P.4
-
52
-
-
84885437303
-
Invasive hemodynamic assessment of "paradoxical" low-flow severe aortic stenosis
-
O'Sullivan CJ, Stortecky S, Wenaweser P (2013) Invasive hemodynamic assessment of "paradoxical" low-flow severe aortic stenosis. J Am Coll Cardiol 62:1492-1493
-
(2013)
J Am Coll Cardiol
, vol.62
, pp. 1492-1493
-
-
O'Sullivan, C.J.1
Stortecky, S.2
Wenaweser, P.3
-
53
-
-
76049099723
-
Current balloon-expandable transcatheter heart valve and delivery systems
-
Nietlispach F, Wijesinghe N, Wood D, Carere RG, Webb JG (2010) Current balloon-expandable transcatheter heart valve and delivery systems. Catheter Cardiovasc Interv Off J Soc Cardiac Angiogr Interv 75:295-300
-
(2010)
Catheter Cardiovasc Interv off J Soc Cardiac Angiogr Interv
, vol.75
, pp. 295-300
-
-
Nietlispach, F.1
Wijesinghe, N.2
Wood, D.3
Carere, R.G.4
Webb, J.G.5
-
54
-
-
84869055716
-
Transcatheter aortic valve implantation: The procedure
-
Stortecky S, Buellesfeld L, Wenaweser P, Windecker S (2012) Transcatheter aortic valve implantation: the procedure. Heart 98(Suppl 4):44-51
-
(2012)
Heart
, vol.98
, Issue.SUPPL. 4
, pp. 44-51
-
-
Stortecky, S.1
Buellesfeld, L.2
Wenaweser, P.3
Windecker, S.4
-
55
-
-
84856264422
-
Local versus general anesthesia for transfemoral aortic valve implantation
-
Motloch LJ, Rottlaender D, Reda S, Larbig R, Bruns M, Muller-Ehmsen J, Strauch J, Madershahian N, Erdmann E, Wahlers T, Hoppe UC (2012) Local versus general anesthesia for transfemoral aortic valve implantation. Clin Res Cardiol Off J Ger Cardiac Soc 101:45-53
-
(2012)
Clin Res Cardiol off J Ger Cardiac Soc
, vol.101
, pp. 45-53
-
-
Motloch, L.J.1
Rottlaender, D.2
Reda, S.3
Larbig, R.4
Bruns, M.5
Muller-Ehmsen, J.6
Strauch, J.7
Madershahian, N.8
Erdmann, E.9
Wahlers, T.10
Hoppe, U.C.11
-
56
-
-
84870993083
-
Effect of local anesthetic management with conscious sedation in patients undergoing transcatheter aortic valve implantation
-
Yamamoto M, Meguro K, Mouillet G, Bergoend E, Monin JL, Lim P, Dubois-Rande JL, Teiger E (2013) Effect of local anesthetic management with conscious sedation in patients undergoing transcatheter aortic valve implantation. Am J Cardiol 111:94-99
-
(2013)
Am J Cardiol
, vol.111
, pp. 94-99
-
-
Yamamoto, M.1
Meguro, K.2
Mouillet, G.3
Bergoend, E.4
Monin, J.L.5
Lim, P.6
Dubois-Rande, J.L.7
Teiger, E.8
-
57
-
-
84866097368
-
Vascular complications after transcatheter aortic valve replacement: Insights from the partner (placement of aortic transcatheter valve) trial
-
Genereux P, Webb JG, Svensson LG, Kodali SK, Satler LF, Fearon WF, Davidson CJ, Eisenhauer AC, Makkar RR, Bergman GW, Babaliaros V, Bavaria JE, Velazquez OC, Williams MR, Hueter I, Xu K, Leon MB (2012) Vascular complications after transcatheter aortic valve replacement: insights from the partner (placement of aortic transcatheter valve) trial. J Am Coll Cardiol 60:1043-1052
-
(2012)
J Am Coll Cardiol
, vol.60
, pp. 1043-1052
-
-
Genereux, P.1
Webb, J.G.2
Svensson, L.G.3
Kodali, S.K.4
Satler, L.F.5
Fearon, W.F.6
Davidson, C.J.7
Eisenhauer, A.C.8
Makkar, R.R.9
Bergman, G.W.10
Babaliaros, V.11
Bavaria, J.E.12
Velazquez, O.C.13
Williams, M.R.14
Hueter, I.15
Xu, K.16
Leon, M.B.17
-
58
-
-
84860436228
-
Registry of transcatheter aortic-valve implantation in high-risk patients
-
Gilard M, Eltchaninoff H, Iung B, Donzeau-Gouge P, Chevreul K, Fajadet J, Leprince P, Leguerrier A, Lievre M, Prat A, Teiger E, Lefevre T, Himbert D, Tchetche D, Carrie D, Albat B, Cribier A, Rioufol G, Sudre A, Blanchard D, Collet F, Dos Santos P, Meneveau N, Tirouvanziam A, Caussin C, Guyon P, Boschat J, Le Breton H, Collart F, Houel R, Delpine S, Souteyrand G, Favereau X, Ohlmann P, Doisy V, Grollier G, Gommeaux A, Claudel JP, Bourlon F, Bertrand B, Van Belle E, Laskar M (2012) Registry of transcatheter aortic-valve implantation in high-risk patients. N Engl J Med 366:1705-1715
-
(2012)
N Engl J Med
, vol.366
, pp. 1705-1715
-
-
Gilard, M.1
Eltchaninoff, H.2
Iung, B.3
Donzeau-Gouge, P.4
Chevreul, K.5
Fajadet, J.6
Leprince, P.7
Leguerrier, A.8
Lievre, M.9
Prat, A.10
Teiger, E.11
Lefevre, T.12
Himbert, D.13
Tchetche, D.14
Carrie, D.15
Albat, B.16
Cribier, A.17
Rioufol, G.18
Sudre, A.19
Blanchard, D.20
Collet, F.21
Dos Santos, P.22
Meneveau, N.23
Tirouvanziam, A.24
Caussin, C.25
Guyon, P.26
Boschat, J.27
Le Breton, H.28
Collart, F.29
Houel, R.30
Delpine, S.31
Souteyrand, G.32
Favereau, X.33
Ohlmann, P.34
Doisy, V.35
Grollier, G.36
Gommeaux, A.37
Claudel, J.P.38
Bourlon, F.39
Bertrand, B.40
Van Belle, E.41
Laskar, M.42
more..
-
59
-
-
84864744842
-
Current status of transcatheter aortic valve replacement
-
Webb JG, Wood DA (2012) Current status of transcatheter aortic valve replacement. J Am Coll Cardiol 60:483-492
-
(2012)
J Am Coll Cardiol
, vol.60
, pp. 483-492
-
-
Webb, J.G.1
Wood, D.A.2
-
60
-
-
84883010258
-
Safety and efficacy of the subclavian access route for tavi in cases of missing transfemoral access
-
Muensterer A, Mazzitelli D, Ruge H, Wagner A, Hettich I, Piazza N, Lange R, Bleiziffer S (2013) Safety and efficacy of the subclavian access route for tavi in cases of missing transfemoral access. Clin Res Cardiol Off J Ger Cardiac Soc 102:627-636
-
(2013)
Clin Res Cardiol off J Ger Cardiac Soc
, vol.102
, pp. 627-636
-
-
Muensterer, A.1
Mazzitelli, D.2
Ruge, H.3
Wagner, A.4
Hettich, I.5
Piazza, N.6
Lange, R.7
Bleiziffer, S.8
-
61
-
-
84880317778
-
Management of vascular access in transcatheter aortic valve replacement part 1: Basic anatomy, imaging, sheaths, wires, and access routes
-
Toggweiler S, Leipsic J, Binder RK, Freeman M, Barbanti M, Heijmen RH, Wood DA, Webb JG (2013) Management of vascular access in transcatheter aortic valve replacement part 1: basic anatomy, imaging, sheaths, wires, and access routes. JACC Cardiovasc Interv 6:643-653
-
(2013)
JACC Cardiovasc Interv
, vol.6
, pp. 643-653
-
-
Toggweiler, S.1
Leipsic, J.2
Binder, R.K.3
Freeman, M.4
Barbanti, M.5
Heijmen, R.H.6
Wood, D.A.7
Webb, J.G.8
-
62
-
-
84861563917
-
Direct percutaneous access technique for transaxillary transcatheter aortic valve implantation: The hamburg sankt georg approach
-
Schafer U, Ho Y, Frerker C, Schewel D, Sanchez-Quintana D, Schofer J, Bijuklic K, Meincke F, Thielsen T, Kreidel F, Kuck KH (2012) Direct percutaneous access technique for transaxillary transcatheter aortic valve implantation: the hamburg sankt georg approach. JACC Cardiovasc Interv 5:477-486
-
(2012)
JACC Cardiovasc Interv
, vol.5
, pp. 477-486
-
-
Schafer, U.1
Ho, Y.2
Frerker, C.3
Schewel, D.4
Sanchez-Quintana, D.5
Schofer, J.6
Bijuklic, K.7
Meincke, F.8
Thielsen, T.9
Kreidel, F.10
Kuck, K.H.11
-
63
-
-
84859085367
-
Completely percutaneous transcatheter aortic valve implantation through transaxillary route: An evolving concept
-
van Mieghem NM, Luthen C, Oei F, Schultz C, Ligthart J, Kappetein AP, de Jaegere PP (2012) Completely percutaneous transcatheter aortic valve implantation through transaxillary route: an evolving concept. EuroInterv J EuroPCR Collab Work Gr Interv Cardiol Eur Soc Cardiol 7:1340-1342
-
(2012)
EuroInterv J EuroPCR Collab Work Gr Interv Cardiol Eur Soc Cardiol
, vol.7
, pp. 1340-1342
-
-
Van Mieghem, N.M.1
Luthen, C.2
Oei, F.3
Schultz, C.4
Ligthart, J.5
Kappetein, A.P.6
De Jaegere, P.P.7
-
65
-
-
84874092606
-
Balloon expandable sheath for transfemoral aortic valve implantation: A viable option for patients with challenging access
-
Dimitriadis Z, Scholtz W, Faber L, Borgermann J, Kleikamp G, Horstkotte D, Wiemer M (2013) Balloon expandable sheath for transfemoral aortic valve implantation: a viable option for patients with challenging access. J Interv Cardiol 26:84-89
-
(2013)
J Interv Cardiol
, vol.26
, pp. 84-89
-
-
Dimitriadis, Z.1
Scholtz, W.2
Faber, L.3
Borgermann, J.4
Kleikamp, G.5
Horstkotte, D.6
Wiemer, M.7
-
66
-
-
79961022681
-
One-year outcomes of cohort 1 in the edwards sapien aortic bioprosthesis european outcome (source) registry: The european registry of transcatheter aortic valve implantation using the edwards sapien valve
-
Thomas M, Schymik G, Walther T, Himbert D, Lefevre T, Treede H, Eggebrecht H, Rubino P, Colombo A, Lange R, Schwarz RR, Wendler O (2011) One-year outcomes of cohort 1 in the edwards sapien aortic bioprosthesis european outcome (source) registry: the european registry of transcatheter aortic valve implantation using the edwards sapien valve. Circulation 124:425-433
-
(2011)
Circulation
, vol.124
, pp. 425-433
-
-
Thomas, M.1
Schymik, G.2
Walther, T.3
Himbert, D.4
Lefevre, T.5
Treede, H.6
Eggebrecht, H.7
Rubino, P.8
Colombo, A.9
Lange, R.10
Schwarz, R.R.11
Wendler, O.12
-
67
-
-
77958594295
-
Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery
-
Leon MB, Smith CR, Mack M, Miller DC, Moses JW, Svensson LG, Tuzcu EM, Webb JG, Fontana GP, Makkar RR, Brown DL, Block PC, Guyton RA, Pichard AD, Bavaria JE, Herrmann HC, Douglas PS, Petersen JL, Akin JJ, Anderson WN, Wang D, Pocock S (2010) Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med 363:1597-1607
-
(2010)
N Engl J Med
, vol.363
, pp. 1597-1607
-
-
Leon, M.B.1
Smith, C.R.2
Mack, M.3
Miller, D.C.4
Moses, J.W.5
Svensson, L.G.6
Tuzcu, E.M.7
Webb, J.G.8
Fontana, G.P.9
Makkar, R.R.10
Brown, D.L.11
Block, P.C.12
Guyton, R.A.13
Pichard, A.D.14
Bavaria, J.E.15
Herrmann, H.C.16
Douglas, P.S.17
Petersen, J.L.18
Akin, J.J.19
Anderson, W.N.20
Wang, D.21
Pocock, S.22
more..
-
68
-
-
84899996340
-
One-year outcomes from the source xt post approval study
-
Presented at
-
Windecker S (2013) One-year outcomes from the source xt post approval study. Presented at EuroPCR 2013
-
(2013)
EuroPCR 2013
-
-
Windecker, S.1
-
69
-
-
84880584190
-
A randomized evaluation of the sapien xt transcatheter valve system in patients with aortic stenosis who are not candidates for surgery: Partner ii, inoperable cohort
-
Presented at the
-
Leon MB (2013) A randomized evaluation of the sapien xt transcatheter valve system in patients with aortic stenosis who are not candidates for surgery: Partner ii, inoperable cohort. Presented at the American College of Cardiology Scientific Sessions, 10 March 2013
-
(2013)
American College of Cardiology Scientific Sessions, 10 March 2013
-
-
Leon, M.B.1
-
70
-
-
84863338349
-
Transcatheter (tavr) versus surgical (avr) aortic valve replacement: Occurrence, hazard, risk factors, and consequences of neurologic events in the partner trial
-
Miller DC, Blackstone EH, Mack MJ, Svensson LG, Kodali SK, Kapadia S, Rajeswaran J, Anderson WN, Moses JW, Tuzcu EM, Webb JG, Leon MB, Smith CR (2012) Transcatheter (tavr) versus surgical (avr) aortic valve replacement: occurrence, hazard, risk factors, and consequences of neurologic events in the partner trial. J Thorac Cardiovasc Surg 143(832-843):e813
-
(2012)
J Thorac Cardiovasc Surg
, vol.143
, Issue.832-843
-
-
Miller, D.C.1
Blackstone, E.H.2
Mack, M.J.3
Svensson, L.G.4
Kodali, S.K.5
Kapadia, S.6
Rajeswaran, J.7
Anderson, W.N.8
Moses, J.W.9
Tuzcu, E.M.10
Webb, J.G.11
Leon, M.B.12
Smith, C.R.13
-
71
-
-
84864285945
-
New conduction abnormalities after tavi-frequency and causes
-
van der Boon RM, Nuis RJ, Van Mieghem NM, Jordaens L, Rodes-Cabau J, van Domburg RT, Serruys PW, Anderson RH, de Jaegere PP (2012) New conduction abnormalities after tavi-frequency and causes. Nat Rev Cardiol 9:454-463
-
(2012)
Nat Rev Cardiol
, vol.9
, pp. 454-463
-
-
Van Der Boon, R.M.1
Nuis, R.J.2
Van Mieghem, N.M.3
Jordaens, L.4
Rodes-Cabau, J.5
Van Domburg, R.T.6
Serruys, P.W.7
Anderson, R.H.8
De Jaegere, P.P.9
-
72
-
-
79952738239
-
Permanent pacemaker insertion after corevalve transcatheter aortic valve implantation: Incidence and contributing factors (the UK corevalve collaborative)
-
Khawaja MZ, Rajani R, Cook A, Khavandi A, Moynagh A, Chowdhary S, Spence MS, Brown S, Khan SQ, Walker N, Trivedi U, Hutchinson N, De Belder AJ, Moat N, Blackman DJ, Levy RD, Manoharan G, Roberts D, Khogali SS, Crean P, Brecker SJ, Baumbach A, Mullen M, Laborde JC, Hildick-Smith D (2011) Permanent pacemaker insertion after corevalve transcatheter aortic valve implantation: incidence and contributing factors (the UK corevalve collaborative). Circulation 123:951-960
-
(2011)
Circulation
, vol.123
, pp. 951-960
-
-
Khawaja, M.Z.1
Rajani, R.2
Cook, A.3
Khavandi, A.4
Moynagh, A.5
Chowdhary, S.6
Spence, M.S.7
Brown, S.8
Khan, S.Q.9
Walker, N.10
Trivedi, U.11
Hutchinson, N.12
De Belder, A.J.13
Moat, N.14
Blackman, D.J.15
Levy, R.D.16
Manoharan, G.17
Roberts, D.18
Khogali, S.S.19
Crean, P.20
Brecker, S.J.21
Baumbach, A.22
Mullen, M.23
Laborde, J.C.24
Hildick-Smith, D.25
more..
-
73
-
-
84864760529
-
Impact of permanent pacemaker implantation on clinical outcome among patients undergoing transcatheter aortic valve implantation
-
Buellesfeld L, Stortecky S, Heg D, Hausen S, Mueller R, Wenaweser P, Pilgrim T, Gloekler S, Khattab AA, Huber C, Carrel T, Eberle B, Meier B, Boekstegers P, Juni P, Gerckens U, Grube E, Windecker S (2012) Impact of permanent pacemaker implantation on clinical outcome among patients undergoing transcatheter aortic valve implantation. J Am Coll Cardiol 60:493-501
-
(2012)
J Am Coll Cardiol
, vol.60
, pp. 493-501
-
-
Buellesfeld, L.1
Stortecky, S.2
Heg, D.3
Hausen, S.4
Mueller, R.5
Wenaweser, P.6
Pilgrim, T.7
Gloekler, S.8
Khattab, A.A.9
Huber, C.10
Carrel, T.11
Eberle, B.12
Meier, B.13
Boekstegers, P.14
Juni, P.15
Gerckens, U.16
Grube, E.17
Windecker, S.18
-
74
-
-
84877347266
-
Evaluation and management of paravalvular aortic regurgitation after transcatheter aortic valve replacement
-
Sinning JM, Vasa-Nicotera M, Chin D, Hammerstingl C, Ghanem A, Bence J, Kovac J, Grube E, Nickenig G, Werner N (2013) Evaluation and management of paravalvular aortic regurgitation after transcatheter aortic valve replacement. J Am Coll Cardiol 62:11-20
-
(2013)
J Am Coll Cardiol
, vol.62
, pp. 11-20
-
-
Sinning, J.M.1
Vasa-Nicotera, M.2
Chin, D.3
Hammerstingl, C.4
Ghanem, A.5
Bence, J.6
Kovac, J.7
Grube, E.8
Nickenig, G.9
Werner, N.10
-
75
-
-
79955891681
-
Aortic regurgitation after transcatheter aortic valve implantation: Incidence and early outcome. Results from the german transcatheter aortic valve interventions registry
-
Abdel-Wahab M, Zahn R, Horack M, Gerckens U, Schuler G, Sievert H, Eggebrecht H, Senges J, Richardt G (2011) Aortic regurgitation after transcatheter aortic valve implantation: incidence and early outcome. Results from the german transcatheter aortic valve interventions registry. Heart 97:899-906
-
(2011)
Heart
, vol.97
, pp. 899-906
-
-
Abdel-Wahab, M.1
Zahn, R.2
Horack, M.3
Gerckens, U.4
Schuler, G.5
Sievert, H.6
Eggebrecht, H.7
Senges, J.8
Richardt, G.9
-
76
-
-
79251565276
-
Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis
-
Tamburino C, Capodanno D, Ramondo A, Petronio AS, Ettori F, Santoro G, Klugmann S, Bedogni F, Maisano F, Marzocchi A, Poli A, Antoniucci D, Napodano M, De Carlo M, Fiorina C, Ussia GP (2011) Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis. Circulation 123:299-308
-
(2011)
Circulation
, vol.123
, pp. 299-308
-
-
Tamburino, C.1
Capodanno, D.2
Ramondo, A.3
Petronio, A.S.4
Ettori, F.5
Santoro, G.6
Klugmann, S.7
Bedogni, F.8
Maisano, F.9
Marzocchi, A.10
Poli, A.11
Antoniucci, D.12
Napodano, M.13
De Carlo, M.14
Fiorina, C.15
Ussia, G.P.16
-
77
-
-
84880591192
-
Transcatheter aortic valve replacement with the sapien 3: A new balloon-expandable transcatheter heart valve
-
Binder RK, Rodes-Cabau J, Wood DA, Mok M, Leipsic J, De Larochelliere R, Toggweiler S, Dumont E, Freeman M, Willson AB, Webb JG (2013) Transcatheter aortic valve replacement with the sapien 3: a new balloon-expandable transcatheter heart valve. JACC Cardiovasc Interv 6:293-300
-
(2013)
JACC Cardiovasc Interv
, vol.6
, pp. 293-300
-
-
Binder, R.K.1
Rodes-Cabau, J.2
Wood, D.A.3
Mok, M.4
Leipsic, J.5
De Larochelliere, R.6
Toggweiler, S.7
Dumont, E.8
Freeman, M.9
Willson, A.B.10
Webb, J.G.11
-
78
-
-
84880238447
-
Clinical outcomes of patients with estimated low or intermediate surgical risk undergoing transcatheter aortic valve implantation
-
Wenaweser P, Stortecky S, Schwander S, Heg D, Huber C, Pilgrim T, Gloekler S, O'Sullivan CJ, Meier B, Juni P, Carrel T, Windecker S (2013) Clinical outcomes of patients with estimated low or intermediate surgical risk undergoing transcatheter aortic valve implantation. Eur Heart J 34:1894-1905
-
(2013)
Eur Heart J
, vol.34
, pp. 1894-1905
-
-
Wenaweser, P.1
Stortecky, S.2
Schwander, S.3
Heg, D.4
Huber, C.5
Pilgrim, T.6
Gloekler, S.7
O'Sullivan, C.J.8
Meier, B.9
Juni, P.10
Carrel, T.11
Windecker, S.12
|