메뉴 건너뛰기




Volumn 6, Issue 3, 2013, Pages 293-300

Transcatheter aortic valve replacement with the SAPIEN 3: A new balloon-expandable transcatheter heart valve

Author keywords

Balloon expandable; SAPIEN 3; Transcatheter aortic valve replacement; Transfemoral

Indexed keywords

AGED; AORTA STENOSIS; AORTA VALVE REGURGITATION; ARTICLE; BALLOON CATHETER; BALLOON EXPANDABLE TRANSCATHETER HEART VALVE; CLINICAL ARTICLE; FEASIBILITY STUDY; FEMALE; HEART VALVE PROSTHESIS; HOSPITAL DISCHARGE; HUMAN; LENGTH OF STAY; MULTIDETECTOR COMPUTED TOMOGRAPHY; NEW YORK HEART ASSOCIATION CLASS; PRIORITY JOURNAL; TRANSCATHETER AORTIC VALVE IMPLANTATION; TREATMENT OUTCOME; ALGORITHM; AORTA VALVE STENOSIS; CANADA; COMPUTER ASSISTED DIAGNOSIS; ECHOCARDIOGRAPHY; EQUIPMENT; HEART CATHETERIZATION; HEART VALVE REPLACEMENT; MALE; METHODOLOGY; MULTICENTER STUDY; PREDICTIVE VALUE; PROSTHESIS; SEVERITY OF ILLNESS INDEX; TIME; TRANSLUMINAL VALVULOPLASTY; VERY ELDERLY;

EID: 84880591192     PISSN: 19368798     EISSN: 18767605     Source Type: Journal    
DOI: 10.1016/j.jcin.2012.09.019     Document Type: Article
Times cited : (188)

References (14)
  • 1
    • 77958594295 scopus 로고    scopus 로고
    • Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery
    • Leon MB, Smith CR, Mack M, et al. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med 2010;363:1597-607.
    • (2010) N Engl J Med , vol.363 , pp. 1597-1607
    • Leon, M.B.1    Smith, C.R.2    Mack, M.3
  • 2
    • 84860466759 scopus 로고    scopus 로고
    • Two-year outcomes after transcatheter or surgical aortic-valve replacement
    • Kodali SK, Williams MR, Smith CR, et al. Two-year outcomes after transcatheter or surgical aortic-valve replacement. N Engl J Med 2012;266:1686 -95.
    • (2012) N Engl J Med , vol.266 , pp. 1686-1695
    • Kodali, S.K.1    Williams, M.R.2    Smith, C.R.3
  • 3
    • 79958204372 scopus 로고    scopus 로고
    • Transcatheter versus surgical aortic-valve replacement in high-risk patients
    • Smith CR, Leon MB, Mack MJ, et al. Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Engl J Med 2011; 364:2187-98.
    • (2011) N Engl J Med , vol.364 , pp. 2187-2198
    • Smith, C.R.1    Leon, M.B.2    Mack, M.J.3
  • 4
    • 84860466759 scopus 로고    scopus 로고
    • Two-year outcomes after transcatheter or surgical aortic-valve replacement
    • Kodali SK, Williams MR, Smith CR, et al. Two-year outcomes after transcatheter or surgical aortic-valve replacement. N Engl J Med 2012;388:1686 -95.
    • (2012) N Engl J Med , vol.388 , pp. 1686-1695
    • Kodali, S.K.1    Williams, M.R.2    Smith, C.R.3
  • 5
    • 0037058854 scopus 로고    scopus 로고
    • Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: First human case description
    • Cribier A, Eltchaninoff H, Bash A, et al. Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description. Circulation 2002;106:3006-8.
    • (2002) Circulation , vol.106 , pp. 3006-3008
    • Cribier, A.1    Eltchaninoff, H.2    Bash, A.3
  • 6
    • 33644860328 scopus 로고    scopus 로고
    • Percutaneous aortic valve implantation retrograde from the femoral artery
    • Webb JG, Chandavimol M, Thompson CR, et al. Percutaneous aortic valve implantation retrograde from the femoral artery. Circulation 2006;113:842-50.
    • (2006) Circulation , vol.113 , pp. 842-850
    • Webb, J.G.1    Chandavimol, M.2    Thompson, C.R.3
  • 7
    • 78651337155 scopus 로고    scopus 로고
    • Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: A consensus report from the valve academic Research Consortium
    • Leon MB, Piazza N, Nikolsky E, et al. Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: a consensus report from the valve academic Research Consortium. J Am Coll Cardiol 2011;57:253-69.
    • (2011) J Am Coll Cardiol , vol.57 , pp. 253-269
    • Leon, M.B.1    Piazza, N.2    Nikolsky, E.3
  • 8
    • 84859160648 scopus 로고    scopus 로고
    • 3-dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement: A multicenter retrospective analysis
    • Willson AB, Webb JG, Labounty TM, et al. 3-dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement: a multicenter retrospective analysis. J Am Coll Cardiol 2012;59:1287-94.
    • (2012) J Am Coll Cardiol , vol.59 , pp. 1287-1294
    • Willson, A.B.1    Webb, J.G.2    Labounty, T.M.3
  • 9
    • 77956623683 scopus 로고    scopus 로고
    • Vascular complications with transcatheter aortic valve implantation using the 18 Fr Medtronic CoreValve system: The Rotterdam experience
    • Van Mieghem NM, Nuis RJ, Piazza N, et al. Vascular complications with transcatheter aortic valve implantation using the 18 Fr Medtronic CoreValve system: the Rotterdam experience. EuroIntervention 2010;5:673-9.
    • (2010) EuroIntervention , vol.5 , pp. 673-679
    • Van Mieghem, N.M.1    Nuis, R.J.2    Piazza, N.3
  • 10
    • 84855403379 scopus 로고    scopus 로고
    • Percutaneous aortic valve replacement: Vascular outcomes with a fully percutaneous procedure
    • Toggweiler S, Gurvitch R, Leipsic J, et al. Percutaneous aortic valve replacement: vascular outcomes with a fully percutaneous procedure. J Am Coll Cardiol 2012;59:113-8.
    • (2012) J Am Coll Cardiol , vol.59 , pp. 113-118
    • Toggweiler, S.1    Gurvitch, R.2    Leipsic, J.3
  • 11
    • 79955891681 scopus 로고    scopus 로고
    • Aortic regurgitation after transcatheter aortic valve implantation: Incidence and early outcome. Results from the German transcatheter aortic valve interventions registry
    • Abdel-Wahab M, Zahn R, Horack M, et al. Aortic regurgitation after transcatheter aortic valve implantation: incidence and early outcome. Results from the German transcatheter aortic valve interventions registry. Heart 2011;97:899 -906.
    • (2011) Heart , vol.97 , pp. 899-906
    • Abdel-Wahab, M.1    Zahn, R.2    Horack, M.3
  • 12
    • 81855227692 scopus 로고    scopus 로고
    • Aortic annulus diameter determination by multidetector computed tomography: Reproducibility, applicability, and implications for transcatheter aortic valve implantation
    • Gurvitch R, Webb JG, Yuan R, et al. Aortic annulus diameter determination by multidetector computed tomography: reproducibility, applicability, and implications for transcatheter aortic valve implantation. J Am Coll Cardiol Intv 2011;4:1235-45.
    • (2011) J Am Coll Cardiol Intv , vol.4 , pp. 1235-1245
    • Gurvitch, R.1    Webb, J.G.2    Yuan, R.3
  • 13
    • 80255137247 scopus 로고    scopus 로고
    • Long-term outcomes after transcatheter aortic valve implantation in high-risk patients with severe aortic stenosis: The UK Tavi (United Kingdom Transcatheter Aortic Valve Implantation) registry
    • Moat NE, Ludman P, de Belder MA, et al. Long-term outcomes after transcatheter aortic valve implantation in high-risk patients with severe aortic stenosis: the UK Tavi (United Kingdom Transcatheter Aortic Valve Implantation) registry. J Am Coll Cardiol 2011;58: 2130 -8.
    • (2011) J Am Coll Cardiol , vol.58 , pp. 2130-2138
    • Moat, N.E.1    Ludman, P.2    De Belder, M.A.3
  • 14
    • 84860436228 scopus 로고    scopus 로고
    • Registry of transcatheter aortic-valve implantation in high-risk patients
    • Gilard M, Eltchaninoff H, Iung B, et al. Registry of transcatheter aortic-valve implantation in high-risk patients. N Engl J Med 2012; 366:1705-15.
    • (2012) N Engl J Med , vol.366 , pp. 1705-1715
    • Gilard, M.1    Eltchaninoff, H.2    Iung, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.