Volumn 6, Issue 2, 2013, Pages 249-262

Standardized imaging for aortic annular sizing: Implications for transcatheter valve selection

Author keywords

Aortic stenosis; Computed tomography; Echocardiography; Patient selection; Transcatheter aortic valve implantation

Indexed keywords

AORTA ROOT; AORTA SINUS; AORTA VALVE; AORTA VALVE PROSTHESIS; AORTA VALVE REPLACEMENT; AORTA VALVE STENOSIS; AORTIC ANNULAR SIZING; AORTIC VALVE REPAIR; ARTICLE; ASCENDING AORTA; CALCIFICATION; CARDIAC IMAGING; HEART LEFT VENTRICLE OUTFLOW TRACT; HEART VALVE BIOPROSTHESIS; HUMAN; IMAGE RECONSTRUCTION; INTERVENTIONAL CARDIOVASCULAR PROCEDURE; MULTIDETECTOR COMPUTED TOMOGRAPHY; PATIENT SELECTION; PERCUTANEOUS CORONARY INTERVENTION; PRIORITY JOURNAL; TRANSCATHETER AORTIC VALVE IMPLANTATION; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; TRANSLUMINAL VALVULOPLASTY; TRANSTHORACIC ECHOCARDIOGRAPHY; COMPUTER ASSISTED DIAGNOSIS; DIAGNOSTIC IMAGING; ECHOGRAPHY; HEART CATHETERIZATION; HEART VALVE PROSTHESIS; HEART VALVE REPLACEMENT; PATHOLOGY; PREDICTIVE VALUE; PROCEDURES; PROSTHESIS; RADIOGRAPHY; THREE DIMENSIONAL IMAGING; EQUIPMENT; METHODOLOGY; REVIEW;

EID: 84881330796     PISSN: 1936878X     EISSN: 18767591     Source Type: Journal    
DOI: 10.1016/j.jcmg.2012.12.005     Document Type: Review
Times cited : (222)

References (49)
  • 1
    • 84864744842 scopus 로고    scopus 로고
    • Current status of transcatheter aortic valve replacement
    • Webb JG, Wood DA. Current status of transcatheter aortic valve replacement. J Am Coll Cardiol 2012;60: 483-92.
    • (2012) J Am Coll Cardiol , vol.60 , pp. 483-492
    • Webb, J.G.1    Wood, D.A.2
  • 2
    • 84862181480 scopus 로고    scopus 로고
    • Clinical outcomes after transcatheter aortic valve replacement using valve academic research consortium definitions: A weighted meta-analysis of 3,519 patients from 16 studies
    • Genereux P, Head SJ, Van Mieghem NM, et al. Clinical outcomes after transcatheter aortic valve replacement using valve academic research consortium definitions: a weighted meta-analysis of 3,519 patients from 16 studies. J Am Coll Cardiol 2012; 59: 2317-26.
    • (2012) J Am Coll Cardiol , vol.59 , pp. 2317-2326
    • Genereux, P.1    Head, S.J.2    Van Mieghem, N.M.3
  • 3
    • 84867326319 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation 10-year anniversary: Review of current evidence and clinical implications
    • Genereux P, Head SJ, Wood DA, et al. Transcatheter aortic valve implantation 10-year anniversary: review of current evidence and clinical implications. Eur Heart J 2012;33: 2388 -98.
    • (2012) Eur Heart J , vol.33 , pp. 2388-2398
    • Genereux, P.1    Head, S.J.2    Wood, D.A.3
  • 4
    • 84867288685 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: 10-year anniversary. Part II: Clinical implications
    • Genereux P, Head SJ, Wood DA, et al. Transcatheter aortic valve implantation: 10-year anniversary. Part II: clinical implications. Eur Heart J 2012;33: 2399-402.
    • (2012) Eur Heart J , vol.33 , pp. 2399-2402
    • Genereux, P.1    Head, S.J.2    Wood, D.A.3
  • 5
    • 77958594295 scopus 로고    scopus 로고
    • Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery
    • Leon MB, Smith CR, Mack M, et al. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med 2010;363: 1597-607.
    • (2010) N Engl J Med , vol.363 , pp. 1597-1607
    • Leon, M.B.1    Smith, C.R.2    MacK, M.3
  • 6
    • 79958204372 scopus 로고    scopus 로고
    • Transcatheter versus surgical aortic-valve replacement in highrisk patients
    • Smith CR, Leon MB, Mack MJ, et al. Transcatheter versus surgical aortic-valve replacement in highrisk patients. N Engl J Med 2011; 364: 2187-98.
    • (2011) N Engl J Med , vol.364 , pp. 2187-2198
    • Smith, C.R.1    Leon, M.B.2    MacK, M.J.3
  • 7
    • 84923308366 scopus 로고    scopus 로고
    • Accessed January 4 2013
    • U.S. Food and Drug Administration. Edwards SAPIEN Transcatheter Heart Valve (THV)-P100041. Available at: http://www.fda.gov/MedicalDevices/ ProductsandMedical Procedures/DeviceApprovalsand Clearances/Recently-Approved Devices/ucm280840.htm. Accessed January 4, 2013.
    • Edwards SAPIEN Transcatheter Heart Valve (THV)-P100041
  • 8
    • 79953856919 scopus 로고    scopus 로고
    • 2-year follow-up of patients undergoing transcatheter aortic valve implantation using a self-expanding valve prosthesis
    • Buellesfeld L, Gerckens U, Schuler G, et al. 2-year follow-up of patients undergoing transcatheter aortic valve implantation using a self-expanding valve prosthesis. J Am Coll Cardiol 2011;57: 1650 -7.
    • (2011) J Am Coll Cardiol , vol.57 , pp. 1650-1657
    • Buellesfeld, L.1    Gerckens, U.2    Schuler, G.3
  • 9
    • 84858793217 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: 3-year outcomes of selfexpanding CoreValve prosthesis
    • Ussia GP, Barbanti M, Petronio AS, et al. Transcatheter aortic valve implantation: 3-year outcomes of selfexpanding CoreValve prosthesis. Eur Heart J 2012;33: 969 -76.
    • (2012) Eur Heart J , vol.33 , pp. 969-976
    • Ussia, G.P.1    Barbanti, M.2    Petronio, A.S.3
  • 11
    • 84863337787 scopus 로고    scopus 로고
    • 2012 ACCF/AATS/SCAI/STS expert consensus document on transcatheter aortic valve replacement
    • Holmes DR Jr, Mack MJ, Kaul S, et al. 2012 ACCF/AATS/SCAI/STS expert consensus document on transcatheter aortic valve replacement. J Am Coll Cardiol 2012;59: 1200 -54.
    • (2012) J Am Coll Cardiol , vol.59 , pp. 1200-1254
    • Holmes Jr., D.R.1    MacK, M.J.2    Kaul, S.3
  • 12
    • 77950526783 scopus 로고    scopus 로고
    • Prosthesis-patient mismatch after transcatheter aortic valve implantation with the Medtronic-CoreValve bioprosthesis
    • Jilaihawi H, Chin D, Spyt T, et al. Prosthesis-patient mismatch after transcatheter aortic valve implantation with the Medtronic-CoreValve bioprosthesis. Eur Heart J 2010;31: 857-64.
    • (2010) Eur Heart J , vol.31 , pp. 857-864
    • Jilaihawi, H.1    Chin, D.2    Spyt, T.3
  • 13
    • 0033646386 scopus 로고    scopus 로고
    • Clinical anatomy of the aortic root
    • Anderson RH. Clinical anatomy of the aortic root. Heart 2000;84: 670 -3.
    • (2000) Heart , vol.84 , pp. 670-673
    • Anderson, R.H.1
  • 14
    • 70349396032 scopus 로고    scopus 로고
    • Determinants of significant paravalvular regurgitation after transcatheter aortic valve: Implantation impact of device and annulus discongruence
    • Detaint D, Lepage L, Himbert D, et al. Determinants of significant paravalvular regurgitation after transcatheter aortic valve: implantation impact of device and annulus discongruence. J Am Coll Cardiol Intv 2009;2: 821-7.
    • (2009) J Am Coll Cardiol Intv , vol.2 , pp. 821-827
    • Detaint, D.1    Lepage, L.2    Himbert, D.3
  • 15
    • 79951963644 scopus 로고    scopus 로고
    • Outcome of patients after transcatheter aortic valve embolization
    • Tay EL, Gurvitch R, Wijeysinghe N, et al. Outcome of patients after transcatheter aortic valve embolization. J Am Coll Cardiol Intv 2011;4: 228-34.
    • (2011) J Am Coll Cardiol Intv , vol.4 , pp. 228-234
    • Tay, E.L.1    Gurvitch, R.2    Wijeysinghe, N.3
  • 16
    • 84868618362 scopus 로고    scopus 로고
    • Prosthesis oversizing in balloonexpandable transcatheter aortic valve implantation is associated with contained rupture of the aortic root
    • Blanke P, Reinohl J, Schlensak C, et al. Prosthesis oversizing in balloonexpandable transcatheter aortic valve implantation is associated with contained rupture of the aortic root. Circ Cardiovasc Interv 2012;5: 540-8.
    • (2012) Circ Cardiovasc Interv , vol.5 , pp. 540-548
    • Blanke, P.1    Reinohl, J.2    Schlensak, C.3
  • 17
    • 44949107279 scopus 로고    scopus 로고
    • Transcatheter valve implantation for patients with aortic stenosis
    • a position statement from the European Association of Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCI)
    • Vahanian A, Alfieri O, Al-Attar N, et al. Transcatheter valve implantation for patients with aortic stenosis: a position statement from the European Association of Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCI). Eur Heart J 2008;29: 1463-70.
    • (2008) Eur Heart J , vol.29 , pp. 1463-1470
    • Vahanian, A.1    Alfieri, O.2    Al-Attar, N.3
  • 18
    • 78650517239 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation in aortic stenosis: The role of echocardiography
    • Jayasuriya C, Moss RR, Munt B. Transcatheter aortic valve implantation in aortic stenosis: the role of echocardiography. J Am Soc Echocardiogr 2011;24: 15-27.
    • (2011) J Am Soc Echocardiogr , vol.24 , pp. 15-27
    • Jayasuriya, C.1    Moss, R.R.2    Munt, B.3
  • 19
    • 41249087660 scopus 로고    scopus 로고
    • Role of echocardiography in percutaneous aortic valve implantation
    • Moss RR, Ivens E, Pasupati S, et al. Role of echocardiography in percutaneous aortic valve implantation. J Am Coll Cardiol Img 2008;1: 15-24.
    • (2008) J Am Coll Cardiol Img , vol.1 , pp. 15-24
    • Moss, R.R.1    Ivens, E.2    Pasupati, S.3
  • 20
    • 73649096192 scopus 로고    scopus 로고
    • Multimodal assessment of the aortic annulus diameter: Implications for transcatheter aortic valve implantation
    • Messika-Zeitoun D, Serfaty JM, Brochet E, et al. Multimodal assessment of the aortic annulus diameter: implications for transcatheter aortic valve implantation. J Am Coll Cardiol 2010;55: 186 -94.
    • (2010) J Am Coll Cardiol , vol.55 , pp. 186-194
    • Messika-Zeitoun, D.1    Serfaty, J.M.2    Brochet, E.3
  • 21
    • 80052051390 scopus 로고    scopus 로고
    • EAE/ASE recommendations for the use of echocardiography in new transcatheter interventions for valvular heart disease
    • Zamorano JL, Badano LP, Bruce C, et al. EAE/ASE recommendations for the use of echocardiography in new transcatheter interventions for valvular heart disease. J Am Soc Echocardiogr 2011;24: 937-65.
    • (2011) J Am Soc Echocardiogr , vol.24 , pp. 937-965
    • Zamorano, J.L.1    Badano, L.P.2    Bruce, C.3
  • 22
    • 73649110271 scopus 로고    scopus 로고
    • Multimodality quantitative imaging of aortic root for transcatheter aortic valve implantation: More complex than it appears
    • Tuzcu EM, Kapadia SR, Schoenhagen P. Multimodality quantitative imaging of aortic root for transcatheter aortic valve implantation: more complex than it appears. J Am Coll Cardiol 2010;55: 195-7.
    • (2010) J Am Coll Cardiol , vol.55 , pp. 195-197
    • Tuzcu, E.M.1    Kapadia, S.R.2    Schoenhagen, P.3
  • 23
    • 78649323412 scopus 로고    scopus 로고
    • Assessment of aortic annulus dimensions for Edwards SAPIEN Transapical Heart Valve implantation by computed tomography: Calculating average diameter using a virtual ring method
    • Blanke P, Siepe M, Reinohl J, et al. Assessment of aortic annulus dimensions for Edwards SAPIEN Transapical Heart Valve implantation by computed tomography: calculating average diameter using a virtual ring method. Eur J Cardiothorac Surg 2010;38: 750-8.
    • (2010) Eur J Cardiothorac Surg , vol.38 , pp. 750-758
    • Blanke, P.1    Siepe, M.2    Reinohl, J.3
  • 24
    • 75749129479 scopus 로고    scopus 로고
    • Comparison of aortic root dimensions and geometries before and after transcatheter aortic valve implantation by 2- and 3-dimensional transesophageal echocardiography and multislice computed tomography
    • Ng AC, Delgado V, van der Kley F, et al. Comparison of aortic root dimensions and geometries before and after transcatheter aortic valve implantation by 2- and 3-dimensional transesophageal echocardiography and multislice computed tomography. Circ Cardiovasc Imaging 2010;3: 94 -102.
    • (2010) Circ Cardiovasc Imaging , vol.3 , pp. 94-102
    • Ng, A.C.1    Delgado, V.2    Van Der Kley, F.3
  • 25
    • 80052673562 scopus 로고    scopus 로고
    • Comparison of two-dimensional and three-dimensional imaging techniques for measurement of aortic annulus diameters before transcatheter aortic valve implantation
    • Altiok E, Koos R, Schroder J, et al. Comparison of two-dimensional and three-dimensional imaging techniques for measurement of aortic annulus diameters before transcatheter aortic valve implantation. Heart 2011;97: 1578-84.
    • (2011) Heart , vol.97 , pp. 1578-1584
    • Altiok, E.1    Koos, R.2    Schroder, J.3
  • 26
    • 84867515040 scopus 로고    scopus 로고
    • Prosthesis/annulus discongruence assessed by three-dimensional transoesophageal echocardiography: A predictor of significant paravalvular aortic regurgitation after transcatheter aortic valve implantation
    • Santos N, de Agustin JA, Almeria C, et al. Prosthesis/annulus discongruence assessed by three-dimensional transoesophageal echocardiography: a predictor of significant paravalvular aortic regurgitation after transcatheter aortic valve implantation. Eur Heart J Cardiovasc Imaging 2012;13: 931-7.
    • (2012) Eur Heart J Cardiovasc Imaging , vol.13 , pp. 931-937
    • Santos, N.1    De Agustin, J.A.2    Almeria, C.3
  • 27
    • 79952980048 scopus 로고    scopus 로고
    • Measurement of the aortic annulus size by real-time three-dimensional transesophageal echocardiography
    • Janosi RA, Kahlert P, Plicht B, et al. Measurement of the aortic annulus size by real-time three-dimensional transesophageal echocardiography. Minim Invasive Ther Allied Technol 2011;20: 85-94.
    • (2011) Minim Invasive Ther Allied Technol , vol.20 , pp. 85-94
    • Janosi, R.A.1    Kahlert, P.2    Plicht, B.3
  • 28
    • 43649086862 scopus 로고    scopus 로고
    • Noninvasive evaluation of the aortic root with multislice computed tomography implications for transcatheter aortic valve replacement
    • Tops LF, Wood DA, Delgado V, et al. Noninvasive evaluation of the aortic root with multislice computed tomography implications for transcatheter aortic valve replacement. J Am Coll Cardiol Img 2008;1: 321-30.
    • (2008) J Am Coll Cardiol Img , vol.1 , pp. 321-330
    • Tops, L.F.1    Wood, D.A.2    Delgado, V.3
  • 29
    • 69949174862 scopus 로고    scopus 로고
    • Threedimensional imaging of the aortic valve and aortic root with computed tomography: New standards in an era of transcatheter valve repair/implantation
    • Schoenhagen P, Tuzcu EM, Kapadia SR, Desai MY, Svensson LG. Threedimensional imaging of the aortic valve and aortic root with computed tomography: new standards in an era of transcatheter valve repair/implantation. Eur Heart J 2009;30: 2079-86.
    • (2009) Eur Heart J , vol.30 , pp. 2079-2086
    • Schoenhagen, P.1    Tuzcu, E.M.2    Kapadia, S.R.3    Desai, M.Y.4    Svensson, L.G.5
  • 30
    • 62849087967 scopus 로고    scopus 로고
    • Aortic root morphology in patients undergoing percutaneous aortic valve replacement: Evidence of aortic root remodeling
    • Akhtar M, Tuzcu EM, Kapadia SR, et al. Aortic root morphology in patients undergoing percutaneous aortic valve replacement: evidence of aortic root remodeling. The Journal of thoracic and cardiovascular surgery 2009; 137: 950-6.
    • (2009) The Journal of Thoracic and Cardiovascular Surgery , vol.137 , pp. 950-956
    • Akhtar, M.1    Tuzcu, E.M.2    Kapadia, S.R.3
  • 31
    • 78649380234 scopus 로고    scopus 로고
    • Three-dimensional imaging in the context of minimally invasive and transcatheter cardiovascular interventions using multi-detector computed tomography: From pre-operative planning to intra-operative guidance
    • Schoenhagen P, Numburi U, Halliburton SS, et al. Three-dimensional imaging in the context of minimally invasive and transcatheter cardiovascular interventions using multi-detector computed tomography: from pre-operative planning to intra-operative guidance. Eur Heart J 2010;31: 2727-40.
    • (2010) Eur Heart J , vol.31 , pp. 2727-2740
    • Schoenhagen, P.1    Numburi, U.2    Halliburton, S.S.3
  • 32
    • 79954492455 scopus 로고    scopus 로고
    • Multidetector computed tomography in transcatheter aortic valve implantation
    • Leipsic J, Gurvitch R, Labounty TM, et al. Multidetector computed tomography in transcatheter aortic valve implantation. J Am Coll Cardiol Img 2011;4: 416 -29.
    • (2011) J Am Coll Cardiol Img , vol.4 , pp. 416-429
    • Leipsic, J.1    Gurvitch, R.2    Labounty, T.M.3
  • 33
    • 80555156713 scopus 로고    scopus 로고
    • Integration of 3D imaging data in the assessment of aortic stenosis: Impact on classification of disease severity
    • O'Brien B, Schoenhagen P, Kapadia SR, et al. Integration of 3D imaging data in the assessment of aortic stenosis: impact on classification of disease severity. Circ Cardiovasc Imaging 2011;4: 566 -73.
    • (2011) Circ Cardiovasc Imaging , vol.4 , pp. 566-573
    • O'Brien, B.1    Schoenhagen, P.2    Kapadia, S.R.3
  • 34
    • 84860207668 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: Implications of multimodality imaging in patient selection, procedural guidance, and outcomes
    • Delgado V, Kapadia S, Schalij MJ, Schuijf JD, Tuzcu EM, Bax JJ. Transcatheter aortic valve implantation: implications of multimodality imaging in patient selection, procedural guidance, and outcomes. Heart 2012;98: 743-54.
    • (2012) Heart , vol.98 , pp. 743-754
    • Delgado, V.1    Kapadia, S.2    Schalij, M.J.3    Schuijf, J.D.4    Tuzcu, E.M.5    Bax, J.J.6
  • 35
    • 84859567725 scopus 로고    scopus 로고
    • A practical guide to multimodality imaging of transcatheter aortic valve replacement
    • Bloomfield GS, Gillam LD, Hahn RT, et al. A practical guide to multimodality imaging of transcatheter aortic valve replacement. J Am Coll Cardiol Img 2012;5: 441-55.
    • (2012) J Am Coll Cardiol Img , vol.5 , pp. 441-455
    • Bloomfield, G.S.1    Gillam, L.D.2    Hahn, R.T.3
  • 36
    • 77950501005 scopus 로고    scopus 로고
    • Three dimensional evaluation of the aortic annulus using multislice computer tomography: Are manufacturer's guidelines for sizing for percutaneous aortic valve replacement helpful?
    • Schultz CJ, Moelker A, Piazza N, et al. Three dimensional evaluation of the aortic annulus using multislice computer tomography: are manufacturer's guidelines for sizing for percutaneous aortic valve replacement helpful? Eur Heart J 2010;31: 849 -56.
    • (2010) Eur Heart J , vol.31 , pp. 849-856
    • Schultz, C.J.1    Moelker, A.2    Piazza, N.3
  • 37
    • 84859164235 scopus 로고    scopus 로고
    • Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of paravalvular aortic regurgitation
    • Jilaihawi H, Kashif M, Fontana G, et al. Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of paravalvular aortic regurgitation. J Am Coll Cardiol 2012;59: 1275-86.
    • (2012) J Am Coll Cardiol , vol.59 , pp. 1275-1286
    • Jilaihawi, H.1    Kashif, M.2    Fontana, G.3
  • 38
    • 79951980554 scopus 로고    scopus 로고
    • Preoperative assessment of aortic annulus dimensions: Comparison of noninvasive and intraoperative measurement
    • Dashkevich A, Blanke P, Siepe M, et al. Preoperative assessment of aortic annulus dimensions: comparison of noninvasive and intraoperative measurement. Ann Thorac Surg 2011;91: 709-14.
    • (2011) Ann Thorac Surg , vol.91 , pp. 709-714
    • Dashkevich, A.1    Blanke, P.2    Siepe, M.3
  • 39
    • 84864215288 scopus 로고    scopus 로고
    • Aortic annulus sizing: Echocardiographic vs. Computed tomography derived measurements in comparison with direct surgical sizing
    • Kempfert J, Van Linden A, Lehmkuhl L, et al. Aortic annulus sizing: echocardiographic vs. computed tomography derived measurements in comparison with direct surgical sizing. Eur J Cardiothorac Surg 2012;42: 627-33.
    • (2012) Eur J Cardiothorac Surg , vol.42 , pp. 627-633
    • Kempfert, J.1    Van Linden, A.2    Lehmkuhl, L.3
  • 40
    • 78449265988 scopus 로고    scopus 로고
    • Multislice computed tomography for prediction of optimal angiographic deployment projections during transcatheter aortic valve implantation
    • Gurvitch R, Wood DA, Leipsic J, et al. Multislice computed tomography for prediction of optimal angiographic deployment projections during transcatheter aortic valve implantation. J Am Coll Cardiol Intv 2010;3: 1157-65.
    • (2010) J Am Coll Cardiol Intv , vol.3 , pp. 1157-1165
    • Gurvitch, R.1    Wood, D.A.2    Leipsic, J.3
  • 41
    • 74049098326 scopus 로고    scopus 로고
    • Pre-procedural imaging of aortic root orientation and dimensions: Comparison between x-ray angiographic planar imaging and 3-dimensional multidetector row computed tomography
    • Kurra V, Kapadia SR, Tuzcu EM, et al. Pre-procedural imaging of aortic root orientation and dimensions: comparison between x-ray angiographic planar imaging and 3-dimensional multidetector row computed tomography. J Am Coll Cardiol Intv 2010;3: 105-13.
    • (2010) J Am Coll Cardiol Intv , vol.3 , pp. 105-113
    • Kurra, V.1    Kapadia, S.R.2    Tuzcu, E.M.3
  • 42
    • 84861434407 scopus 로고    scopus 로고
    • Sizing the annulus for transcatheter aortic valve implantation: More than a simple measure?
    • Cerillo AG, Mariani M, Glauber M, Berti S. Sizing the annulus for transcatheter aortic valve implantation: more than a simple measure? Eur J Cardiothorac Surg 2012;41: 717-8.
    • (2012) Eur J Cardiothorac Surg , vol.41 , pp. 717-718
    • Cerillo, A.G.1    Mariani, M.2    Glauber, M.3    Berti, S.4
  • 43
    • 0023155994 scopus 로고
    • Percutaneous transluminal balloon valvuloplasty of adult aortic stenosis: Report of 92 cases
    • Cribier A, Savin T, Berland J, et al. Percutaneous transluminal balloon valvuloplasty of adult aortic stenosis: report of 92 cases. J Am Coll Cardiol 1987;9: 381-6.
    • (1987) J Am Coll Cardiol , vol.9 , pp. 381-386
    • Cribier, A.1    Savin, T.2    Berland, J.3
  • 44
    • 54049102823 scopus 로고    scopus 로고
    • Can balloon aortic valvuloplasty help determine appropriate transcatheter aortic valve size?
    • Babaliaros VC, Liff D, Chen EP, et al. Can balloon aortic valvuloplasty help determine appropriate transcatheter aortic valve size? J Am Coll Cardiol Intv 2008;1: 580-6.
    • (2008) J Am Coll Cardiol Intv , vol.1 , pp. 580-586
    • Babaliaros, V.C.1    Liff, D.2    Chen, E.P.3
  • 45
    • 74049138751 scopus 로고    scopus 로고
    • Use of balloon aortic valvuloplasty to size the aortic annulus before implantation of a balloonexpandable transcatheter heart valve
    • Babaliaros VC, Junagadhwalla Z, Lerakis S, et al. Use of balloon aortic valvuloplasty to size the aortic annulus before implantation of a balloonexpandable transcatheter heart valve. J Am Coll Cardiol Intv 2010;3: 114-8.
    • (2010) J Am Coll Cardiol Intv , vol.3 , pp. 114-118
    • Babaliaros, V.C.1    Junagadhwalla, Z.2    Lerakis, S.3
  • 47
    • 78650510509 scopus 로고    scopus 로고
    • Anatomic suitability for present and next generation transcatheter aortic valve prostheses: Evidence for a complementary multidevice approach to treatment
    • Jilaihawi H, Bonan R, Asgar A, et al. Anatomic suitability for present and next generation transcatheter aortic valve prostheses: evidence for a complementary multidevice approach to treatment. J Am Coll Cardiol Intv 2010;3: 859-66.
    • (2010) J Am Coll Cardiol Intv , vol.3 , pp. 859-866
    • Jilaihawi, H.1    Bonan, R.2    Asgar, A.3
  • 48
    • 84862887730 scopus 로고    scopus 로고
    • Meta-analysis of complications in aortic valve replacement: Comparison of Medtronic-CoreValve, Edwards-SAPIEN and surgical aortic valve replacement in 8,536 patients
    • Jilaihawi H, Chakravarty T, Weiss RE, Fontana GP, Forrester J, Makkar RR. Meta-analysis of complications in aortic valve replacement: comparison of Medtronic-CoreValve, Edwards-SAPIEN and surgical aortic valve replacement in 8,536 patients. Catheter Cardiovasc Interv 2012;80: 128-38.
    • (2012) Catheter Cardiovasc Interv , vol.80 , pp. 128-138
    • Jilaihawi, H.1    Chakravarty, T.2    Weiss, R.E.3    Fontana, G.P.4    Forrester, J.5    Makkar, R.R.6
  • 49
    • 79959575420 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: Know the differences between the currently available technologies
    • MacDonald I, Pasupati S. Transcatheter aortic valve implantation: know the differences between the currently available technologies. Eur Heart J 2010;31: 1663-5.
    • (2010) Eur Heart J , vol.31 , pp. 1663-1665
    • MacDonald, I.1    Pasupati, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.