메뉴 건너뛰기




Volumn 7, Issue 3, 2014, Pages 236-250

Accuracy of transcranial Doppler for the diagnosis of intracardiac right-to-left shunt: A bivariate meta-analysis of prospective studies

Author keywords

patent foramen ovale; right to left shunt; transcranial Doppler

Indexed keywords

ECHOVIST; GELATIN; SODIUM CHLORIDE; CONTRAST MEDIUM;

EID: 84896539242     PISSN: 1936878X     EISSN: 18767591     Source Type: Journal    
DOI: 10.1016/j.jcmg.2013.12.011     Document Type: Article
Times cited : (162)

References (51)
  • 1
    • 0021352808 scopus 로고
    • Incidence and size of patent foramen ovale during the first 10 decades of life: An autopsy study of 965 normal hearts
    • Hagen PT, Scholz DG, Edwards WD. Incidence and size of patent foramen ovale during the first 10 decades of life: an autopsy study of 965 normal hearts. Mayo Clin Proc 1984;59:17-20. (Pubitemid 14175830)
    • (1984) Mayo Clinic Proceedings , vol.59 , Issue.1 , pp. 17-20
    • Hagen, P.T.1    Scholz, D.G.2    Edwards, W.D.3
  • 3
    • 0033549030 scopus 로고    scopus 로고
    • Potential source of cerebral embolism in migraine with aura: A transcranial Doppler study
    • Anzola GP, Magoni M, Guendani M, Rozzini L, Dalla Volta G. Potential source of cerebral embolism in migraine with aura: a transcranial Doppler study. Neurology 1999;52:1622-5. (Pubitemid 29220637)
    • (1999) Neurology , vol.52 , Issue.8 , pp. 1622-1625
    • Anzola, G.P.1    Magoni, M.2    Guindani, M.3    Rozzini, L.4    Volta, G.D.5
  • 4
    • 0027050663 scopus 로고
    • Reversible orthodeoxia
    • Cheng TO. Reversible orthodeoxia. Ann Intern Med 1992;116:875.
    • (1992) Ann Intern Med , vol.116 , pp. 875
    • Cheng, T.O.1
  • 5
    • 0031751103 scopus 로고    scopus 로고
    • Migraine with aura and right-to-left shunt on transcranial Doppler: A case-control study
    • Del Sette M, Angeli S, Leandri M, et al. Migraine with aura and right-to-left shunt on transcranial Doppler: a case-control study. Cerebrovasc Dis 1998;8:327-30.
    • (1998) Cerebrovasc Dis , vol.8 , pp. 327-330
    • Del Sette, M.1    Angeli, S.2    Leandri, M.3
  • 6
    • 0031963545 scopus 로고    scopus 로고
    • Prevalence of patent foramen ovale and its contribution to hypoxemia in patients with obstructive sleep apnea
    • Shanoudy H, Soliman A, Raggi P, Liu JW, Russell DC, Jarmukli NF. Prevalence of patent foramen ovale and its contribution to hypoxemia in patients with obstructive sleep apnea. Chest 1998;113:91-6. (Pubitemid 28044930)
    • (1998) Chest , vol.113 , Issue.1 , pp. 91-96
    • Shanoudy, H.1    Soliman, A.2    Raggi, P.3    Liu, J.W.4    Russell, D.C.5    Jarmukli, N.F.6
  • 7
    • 84864055694 scopus 로고    scopus 로고
    • Meta-analysis of transcatheter closure versus medical therapy for patent foramen ovale in prevention of recurrent neurological events after presumed paradoxical embolism
    • Agarwal S, Bajaj NS, Kumbhani DJ, Tuzcu EM, Kapadia SR. Meta-analysis of transcatheter closure versus medical therapy for patent foramen ovale in prevention of recurrent neurological events after presumed paradoxical embolism. J Am Coll Cardiol Intv 2012;5:777-89.
    • (2012) J Am Coll Cardiol Intv , vol.5 , pp. 777-789
    • Agarwal, S.1    Bajaj, N.S.2    Kumbhani, D.J.3    Tuzcu, E.M.4    Kapadia, S.R.5
  • 8
    • 84886577238 scopus 로고    scopus 로고
    • Patent foramen ovale transcatheter closure vs. Medical therapy on recurrent vascular events: A systematic review and meta-analysis of randomized controlled trials
    • Rengifo-Moreno P, Palacios IF, Junpaparp P, Witzke CF, Morris DL, Romero-Corral A. Patent foramen ovale transcatheter closure vs. medical therapy on recurrent vascular events: a systematic review and meta-analysis of randomized controlled trials. Eur Heart J 2013;34:3342-52.
    • (2013) Eur Heart J , vol.34 , pp. 3342-3352
    • Rengifo-Moreno, P.1    Palacios, I.F.2    Junpaparp, P.3    Witzke, C.F.4    Morris, D.L.5    Romero-Corral, A.6
  • 9
    • 0026071709 scopus 로고
    • Superiority of transesophageal echocardiography in detecting cardiac sources of embolism in patients with cerebral ischemia of uncertain etiology
    • Pearson AC, Labovitz AJ, Tatineni S, Gomez CR. Superiority of transesophageal echocardiography in detecting cardiac sources of embolism in patients with cerebral ischemia of uncertain etiology. J Am Coll Cardiol 1991;17:66-72.
    • (1991) J Am Coll Cardiol , vol.17 , pp. 66-72
    • Pearson, A.C.1    Labovitz, A.J.2    Tatineni, S.3    Gomez, C.R.4
  • 10
    • 27244461533 scopus 로고
    • Transesophageal contrast echocardiography and color flow mapping: Methods of choice for the detection of shunts at the atrial level?
    • DOI 10.1016/0002-8703(92)90070-C
    • De Belder MA, Tourikis L, Griffith M. Transesophageal contrast echocardiography and color flow mapping: methods of choice for the detection of shunts at atrial level? Am Heart J 1992;124:1545-50. (Pubitemid 23003589)
    • (1992) American Heart Journal , vol.124 , Issue.6 , pp. 1545-1550
    • De Belder, M.A.1    Tourikis, L.2    Griffith, M.3    Leech, G.4    Camm, A.J.5
  • 11
    • 0026342729 scopus 로고
    • Comparison of transcranial Doppler ultrasound and transesophageal contrast echocardiography in the detection of interatrial right-to-left shunts
    • Nemec JJ, Marwick TH, Lorig RJ, et al. Comparison of transcranial Doppler ultrasound and transesophageal contrast echocardiography in the detection of interatrial right-to-left shunts. Am J Cardiol 1991;68:1498-502.
    • (1991) Am J Cardiol , vol.68 , pp. 1498-1502
    • Nemec, J.J.1    Marwick, T.H.2    Lorig, R.J.3
  • 12
  • 14
    • 0027932157 scopus 로고
    • Comparison of transcranial contrast Doppler sonography and transesophageal contrast echocardiography for the detection of patent foramen ovale in young stroke patients
    • DOI 10.1016/0002-9149(94)90407-3
    • Job FP, Ringelstein EB, Grafen Y, et al. Comparison of transcranial contrast Doppler sonography and transesophageal contrast echocardiography for the detection of patent foramen ovale in young stroke patients. Am J Cardiol 1994;74:381-4. (Pubitemid 24253477)
    • (1994) American Journal of Cardiology , vol.74 , Issue.4 , pp. 381-384
    • Job, F.P.1    Ringelstein, E.B.2    Grafen, Y.3    Flachskampf, F.A.4    Doherty, C.5    Stockmanns, A.6    Hanrath, P.7
  • 15
    • 0028337578 scopus 로고
    • A comparison of transesophageal echocardiography and transcranial Doppler sonography with contrast medium for detection of patent foramen ovale
    • Jauss M, Kaps M, Keberle M, Haberbosch W, Dorndorf W. A comparison of transesophageal echocardiography and transcranial Doppler sonography with contrast medium for detection of patent foramen ovale. Stroke 1994;25:1265-7. (Pubitemid 24164772)
    • (1994) Stroke , vol.25 , Issue.6 , pp. 1265-1267
    • Jauss, M.1    Kaps, M.2    Keberle, M.3    Haberbosch, W.4    Dorndorf, W.5
  • 16
    • 0028059955 scopus 로고
    • Transesophageal echocardiography and contrast-TCD in the detection of a patent foramen ovale: Experiences with 111 patients
    • Klötzsch C, Janssen G, Berlit P. Transesophageal echocardiography and contrast-TCD in the detection of a patent foramen ovale: experiences with 111 patients. Neurology 1994;44: 1603-6. (Pubitemid 24286633)
    • (1994) Neurology , vol.44 , Issue.9 , pp. 1603-1606
    • Klotzsch, C.1    Janssen, G.2    Berlit, P.3
  • 17
    • 0030855712 scopus 로고    scopus 로고
    • Optimized transcranial Doppler technique for the diagnosis of cardiac right-to-left shunts
    • Albert A, Müller HR, Hetzel A. Optimized transcranial Doppler technique for the diagnosis of cardiac right-to-left shunts. J Neuroimaging 1997;7:159-63. (Pubitemid 27310298)
    • (1997) Journal of Neuroimaging , vol.7 , Issue.3 , pp. 159-163
    • Albert, A.1    Muller, H.R.2    Hetzel, A.3
  • 18
    • 0030788936 scopus 로고    scopus 로고
    • Complementarity of contrast transcranial Doppler and contrast transesophageal echocardiography for the detection of patent foramen ovale in stroke patients
    • Devuyst G, Despland PA, Bogousslavsky J, Jeanrenaud X. Complementarity of contrast transcranial Doppler and contrast transesophageal echocardiography for the detection of patent foramen ovale in stroke patients. Eur Neurol 1997;38: 21-5. (Pubitemid 27283074)
    • (1997) European Neurology , vol.38 , Issue.1 , pp. 21-25
    • Devuyst, G.1    Despland, P.-A.2    Bogousslavsky, J.3    Jeanrenaud, X.4
  • 19
    • 0030786384 scopus 로고    scopus 로고
    • Simultaneous bilateral contrast transcranial doppler monitoring in patients with intracardiac and intrapulmonary shunts
    • DOI 10.1016/S0022-510X(97)05367-7, PII S0022510X97053677
    • Horner S, Ni XS, Weihs W, et al. Simultaneous bilateral contrast transcranial Doppler monitoring in patients with intracardiac and intrapulmonary shunts. J Neurol Sci 1997;150:49-57. (Pubitemid 27303793)
    • (1997) Journal of the Neurological Sciences , vol.150 , Issue.1 , pp. 49-57
    • Horner, S.1    Ni, X.S.2    Weihs, W.3    Harb, S.4    Augustin, M.5    Duft, M.6    Niederkorn, K.7
  • 20
    • 0345404427 scopus 로고    scopus 로고
    • Femoral injection of echo contrast medium may increase the sensitivity of testing for a patent foramen ovale
    • Hamann GF, Schätzer-Klotz D, Fröhlig G, et al. Femoral injection of echo contrast medium may increase the sensitivity of testing for a patent foramen ovale. Neurology 1998;50: 1423-8.
    • (1998) Neurology , vol.50 , pp. 1423-1428
    • Hamann, G.F.1    Schätzer-Klotz, D.2    Fröhlig, G.3
  • 21
    • 0031828512 scopus 로고    scopus 로고
    • Detection of patent foramen ovale by transcranial Doppler and carotid duplex ultrasonography: A comparison with transoesophageal echocardiography
    • Nygren AT, Jogestrand T. Detection of patent foramen ovale by transcranial Doppler and carotid duplex ultrasonography: a comparison with transoesophageal echocardiography. Clin Physiol 1998;18:327-30.
    • (1998) Clin Physiol , vol.18 , pp. 327-330
    • Nygren, A.T.1    Jogestrand, T.2
  • 22
    • 0032899810 scopus 로고    scopus 로고
    • Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts. Reproducibility, comparison of 2 agents, and distribution of microemboli
    • Droste DW, Reisener M, Kemény V, et al. Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts. Reproducibility, comparison of 2 agents, and distribution of microemboli. Stroke 1999;30: 1014 -8.
    • (1999) Stroke , vol.30 , pp. 1014-1018
    • Droste, D.W.1    Reisener, M.2    Kemény, V.3
  • 24
    • 0033565148 scopus 로고    scopus 로고
    • Detection of patent foramen ovale. Transesophageal echocardiography and transcranial Doppler sonography with ultrasound contrast media are "supplementary, not competing, diagnostic methods"
    • Munich
    • Heckmann JG, Niedermeier W, Brandt-Pohlmann M, Hilz MJ, Hecht M, Neundörfer B. [Detection of patent foramen ovale. Transesophageal echocardiography and transcranial Doppler sonography with ultrasound contrast media are "supplementary, not competing, diagnostic methods"]. Med Klin (Munich) 1999;94:367-70.
    • (1999) Med Klin , vol.94 , pp. 367-370
    • Heckmann, J.G.1    Niedermeier, W.2    Brandt-Pohlmann, M.3    Hilz, M.J.4    Hecht, M.5    Neundörfer, B.6
  • 25
    • 0033775154 scopus 로고    scopus 로고
    • Transcranial Doppler ultrasonography as a screening technique for detection of a patent foramen ovale before surgery in the sitting position
    • Stendel R, Gramm HJ, Schröder K, Lober C, Brock M. Transcranial Doppler ultrasonography as a screening technique for detection of a patent foramen ovale before surgery in the sitting position. Anesthesiology 2000; 93:971-5.
    • (2000) Anesthesiology , vol.93 , pp. 971-975
    • Stendel, R.1    Gramm, H.J.2    Schröder, K.3    Lober, C.4    Brock, M.5
  • 27
    • 0036000302 scopus 로고    scopus 로고
    • Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts: Comparison of echovist-200 and echovist-300, timing of the Valsalva maneuver, and general recommendations for the performance of the test
    • DOI 10.1159/000057849
    • Droste DW, Jekentaite R, Stypmann J, et al. Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts: comparison of Echovist-200 and Echovist-300, timing of the Valsalva maneuver, and general recommendations for the performance of the test. Cerebrovasc Dis 2002;13: 235-41. (Pubitemid 34518717)
    • (2002) Cerebrovascular Diseases , vol.13 , Issue.4 , pp. 235-241
    • Droste, D.W.1    Jekentaite, R.2    Stypmann, J.3    Grude, M.4    Hansberg, T.5    Ritter, M.6    Nabavi, D.7    Nam, E.-M.8    Dittrich, R.9    Wichter, T.10    Ringelstein, E.B.11
  • 30
    • 33645451063 scopus 로고    scopus 로고
    • Almost perfect concordance between simultaneous transcranial Doppler and transesophageal echocardiography in the quantification of right-to-left shunts
    • Belvís R, Leta RG, Martí-Fàbregas J, et al. Almost perfect concordance between simultaneous transcranial Doppler and transesophageal echocardiography in the quantification of right-to-left shunts. J Neuroimaging 2006;16:133-8.
    • (2006) J Neuroimaging , vol.16 , pp. 133-138
    • Belvís, R.1    Leta, R.G.2    Martí-Fàbregas, J.3
  • 31
    • 32944463757 scopus 로고    scopus 로고
    • Comparison of transthoracic echocardiography using second harmonic imaging, transcranial Doppler and transesophageal echocardiography for the detection of patent foramen ovale in stroke patients
    • DOI 10.1016/j.euje.2005.04.007, PII S1525216705000673
    • Souteyrand G, Motreff P, Lusson JR, et al. Comparison of transthoracic echocardiography using second harmonic imaging, transcranial Doppler and transesophageal echocardiography for the detection of patent foramen ovale in stroke patients. Eur J Echocardiogr 2006;7:147-54. (Pubitemid 43257200)
    • (2006) European Journal of Echocardiography , vol.7 , Issue.2 , pp. 147-154
    • Souteyrand, G.1    Motreff, P.2    Lusson, J.-R.3    Rodriguezz, R.4    Geoffroy, E.5    Dauphin, C.6    Boire, J.-Y.7    Lamaison, D.8    Cassagnes, J.9
  • 32
    • 69149099372 scopus 로고    scopus 로고
    • Transcranial Doppler and transesophageal echocardiography: Comparison of both techniques and prospective clinical relevance of transcranial Doppler in patent foramen ovale detection
    • Caputi L, Carriero MR, Falcone C, et al. Transcranial Doppler and transesophageal echocardiography: comparison of both techniques and prospective clinical relevance of transcranial Doppler in patent foramen ovale detection. J Stroke Cerebrovasc Dis 2009;18:343-8.
    • (2009) J Stroke Cerebrovasc Dis , vol.18 , pp. 343-348
    • Caputi, L.1    Carriero, M.R.2    Falcone, C.3
  • 33
    • 66749150484 scopus 로고    scopus 로고
    • Transcranial Doppler detection of venous-to-arterial circulation shunts: Criteria for patent foramen ovale
    • Sastry S, MacNab A, Daly K, Ray S, McCollum C. Transcranial Doppler detection of venous-to-arterial circulation shunts: criteria for patent foramen ovale. J Clin Ultrasound 2009;37: 276-80.
    • (2009) J Clin Ultrasound , vol.37 , pp. 276-280
    • Sastry, S.1    MacNab, A.2    Daly, K.3    Ray, S.4    McCollum, C.5
  • 34
    • 65349166276 scopus 로고    scopus 로고
    • Patent foramen ovale: Comparison among diagnostic strategies in cryptogenic stroke and migraine
    • Zito C, Dattilo G, Oreto G, et al. Patent foramen ovale: comparison among diagnostic strategies in cryptogenic stroke and migraine. Echocardiography 2009;26:495-503.
    • (2009) Echocardiography , vol.26 , pp. 495-503
    • Zito, C.1    Dattilo, G.2    Oreto, G.3
  • 35
    • 74949096518 scopus 로고    scopus 로고
    • Transthoracic second harmonic two-and three-dimensional echocardiography for detection of patent foramen ovale
    • Maffè S, Dellavesa P, Zenone F, et al. Transthoracic second harmonic two-and three-dimensional echocardiography for detection of patent foramen ovale. Eur J Echocardiogr 2010;11: 57- 63.
    • (2010) Eur J Echocardiogr , vol.11 , pp. 57-63
    • Maffè, S.1    Dellavesa, P.2    Zenone, F.3
  • 36
    • 77956396127 scopus 로고    scopus 로고
    • Follow-up of residual shunt after patent foramen ovale closure
    • Orzan F, Liboni W, Bonzano A, et al. Follow-up of residual shunt after patent foramen ovale closure. Acta Neurol Scand 2010;122:257-61.
    • (2010) Acta Neurol Scand , vol.122 , pp. 257-261
    • Orzan, F.1    Liboni, W.2    Bonzano, A.3
  • 37
    • 79951720906 scopus 로고    scopus 로고
    • Diagnosis and quantification of patent foramen ovale. Which is the reference technique? Simultaneous study with transcranial Doppler, transthoracic and transesophageal echocardiography
    • González-Alujas T, Evangelista A, Santamarina E, et al. Diagnosis and quantification of patent foramen ovale. Which is the reference technique? Simultaneous study with transcranial Doppler, transthoracic and transesophageal echocardiography. Rev Esp Cardiol 2011;64:133-9.
    • (2011) Rev Esp Cardiol , vol.64 , pp. 133-139
    • González-Alujas, T.1    Evangelista, A.2    Santamarina, E.3
  • 38
    • 80054740636 scopus 로고    scopus 로고
    • QUADAS-2: A revised tool for the quality assessment of diagnostic accuracy studies
    • Whiting PF, Rutjes AW, Westwood ME, et al. QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Ann Intern Med 2011;155:529-36.
    • (2011) Ann Intern Med , vol.155 , pp. 529-536
    • Whiting, P.F.1    Rutjes, A.W.2    Westwood, M.E.3
  • 39
  • 40
    • 0027715844 scopus 로고
    • Estimating diagnostic accuracy from multiple conflicting reports: A new meta-analytic method
    • DOI 10.1177/0272989X9301300408
    • Littenberg B, Moses LE. Estimating diagnostic accuracy from multiple conflicting reports: a new meta-analytic method. Med Decis Making 1993;13: 313-21. (Pubitemid 24013154)
    • (1993) Medical Decision Making , vol.13 , Issue.4 , pp. 313-321
    • Littenberg, B.1    Moses, L.E.2
  • 41
    • 23644432857 scopus 로고    scopus 로고
    • The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessed
    • DOI 10.1016/j.jclinepi.2005.01.016, PII S0895435605001423
    • Deeks JJ, Macaskill P, Irwig L. The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessed. J Clin Epidemiol 2005;58:882-93. (Pubitemid 41115772)
    • (2005) Journal of Clinical Epidemiology , vol.58 , Issue.9 , pp. 882-893
    • Deeks, J.J.1    Macaskill, P.2    Irwig, L.3
  • 42
    • 69949085912 scopus 로고    scopus 로고
    • Meta-analysis of diagnostic accuracy studies accounting for disease prevalence: Alternative parameterizations and model selection
    • Chu H, Nie L, Cole SR, Poole C. Meta-analysis of diagnostic accuracy studies accounting for disease prevalence: alternative parameterizations and model selection. Stat Med 2009; 28:2384-99.
    • (2009) Stat Med , vol.28 , pp. 2384-2399
    • Chu, H.1    Nie, L.2    Cole, S.R.3    Poole, C.4
  • 43
    • 0029931512 scopus 로고    scopus 로고
    • Diagnosis of patent foramen ovale by transesophageal echocardiography and correlation with autopsy findings
    • DOI 10.1016/S0002-9149(96)00163-4
    • Schneider B, Zienkiewicz T, Jansen V, Hofmann T, Noltenius H, Meinertz T. Diagnosis of patent foramen ovale by transesophageal echocardiography and correlation with autopsy findings. Am J Cardiol 1996;77:1202-9. (Pubitemid 26186962)
    • (1996) American Journal of Cardiology , vol.77 , Issue.14 , pp. 1202-1209
    • Schneider, B.1    Zienkiewicz, T.2    Jansen, V.3    Hofmann, T.4    Noltenius, H.5    Meinertz, T.6
  • 44
    • 0026018094 scopus 로고
    • Intraoperative detection of patent foramen ovale by transesophageal echocardiography
    • Konstadt SN, Louie EK, Black S, Rao TL, Scanlon P. Intraoperative detection of patent foramen ovale by transesophageal echocardiography. Anesthesiology 1991;74:212-6.
    • (1991) Anesthesiology , vol.74 , pp. 212-216
    • Konstadt, S.N.1    Louie, E.K.2    Black, S.3    Rao, T.L.4    Scanlon, P.5
  • 45
    • 0026710185 scopus 로고
    • Detection of patent foramen ovale by contrast transesophageal echocardiography
    • Chen WJ, Kuan P, Lien WP, Lin FY. Detection of patent foramen ovale by contrast transesophageal echocardiography. Chest 1992;101:1515-20.
    • (1992) Chest , vol.101 , pp. 1515-1520
    • Chen, W.J.1    Kuan, P.2    Lien, W.P.3    Lin, F.Y.4
  • 46
    • 4944240778 scopus 로고    scopus 로고
    • Power m-mode transcranial Doppler for diagnosis of patent foramen ovale and assessing transcatheter closure
    • DOI 10.1177/1051228404268743
    • Spencer MP, Moehring MA, Jesurum J, Gray WA, Olsen JV, Reisman M. Power m-mode transcranial Doppler for diagnosis of patent foramen ovale and assessing transcatheter closure. J Neuroimaging 2004; 14:342-9. (Pubitemid 39331618)
    • (2004) Journal of Neuroimaging , vol.14 , Issue.4 , pp. 342-349
    • Spencer, M.P.1    Moehring, M.A.2    Jesurum, J.3    Gray, W.A.4    Olsen, J.V.5    Reisman, M.6
  • 47
    • 84871398860 scopus 로고    scopus 로고
    • Detection of right-to-left atrial communication using agitated saline contrast imaging: Experience with 1162 patients and recommendations for echocardiography
    • Marriott K, Manins V, Forshaw A, Wright J, Pascoe R. Detection of right-to-left atrial communication using agitated saline contrast imaging: experience with 1162 patients and recommendations for echocardiography. J Am Soc Echocardiogr 2013;26: 96-102.
    • (2013) J Am Soc Echocardiogr , vol.26 , pp. 96-102
    • Marriott, K.1    Manins, V.2    Forshaw, A.3    Wright, J.4    Pascoe, R.5
  • 48
    • 33645084820 scopus 로고    scopus 로고
    • Therapeutic strategies after examination by transesophageal echocardiography in 503 patients with ischemic stroke
    • DOI 10.1161/01.STR.0000202592.87021.b7, PII 0000767020060300000032
    • Harloff A, Handke M, Reinhard M, Geibel A, Hetzel A. Therapeutic strategies after examination by transesophageal echocardiography in 503 patients with ischemic stroke. Stroke 2006;37:859-64. (Pubitemid 43731922)
    • (2006) Stroke , vol.37 , Issue.3 , pp. 859-864
    • Harloff, A.1    Handke, M.2    Reinhard, M.3    Geibel, A.4    Hetzel, A.5
  • 50
    • 0033773515 scopus 로고    scopus 로고
    • Detection of right-to-left shunt with ultrasound contrast agent and transcranial Doppler sonography
    • Jauss M, Zanette E. Detection of right-to-left shunt with ultrasound contrast agent and transcranial Doppler sonography. Cerebrovasc Dis 2000;10:490-6.
    • (2000) Cerebrovasc Dis , vol.10 , pp. 490-496
    • Jauss, M.1    Zanette, E.2
  • 51
    • 84930092345 scopus 로고    scopus 로고
    • Sensitivity of brachial versus femoral vein injection of agitated saline to detect right-to-left shunts with transcranial Doppler
    • Jan 9 [E-pub ahead of print]
    • Gevorgyan R, Perlowski A, Shenoda M, Mojadidi MK, Agrawal H, Tobis JM. Sensitivity of brachial versus femoral vein injection of agitated saline to detect right-to-left shunts with transcranial Doppler. Catheter Cardiovasc Interv 2014 Jan 9 [E-pub ahead of print], http://dx.doi.org/10.1002/ccd.25391.
    • (2014) Catheter Cardiovasc Interv
    • Gevorgyan, R.1    Perlowski, A.2    Shenoda, M.3    Mojadidi, M.K.4    Agrawal, H.5    Tobis, J.M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.