메뉴 건너뛰기




Volumn 37, Issue 5, 2009, Pages 276-280

Transcranial Doppler detection of venous-to-arterial circulation shunts: Criteria for patent foramen ovale

Author keywords

Contrast agents; Patent foramen ovale; Transcranial Doppler; Transesophageal echocardiography; Venous to arterial circulation shunts

Indexed keywords

ECHO CONTRAST MEDIUM;

EID: 66749150484     PISSN: 00912751     EISSN: 10970096     Source Type: Journal    
DOI: 10.1002/jcu.20564     Document Type: Article
Times cited : (20)

References (19)
  • 1
    • 23444445673 scopus 로고
    • Patent foramen ovale and brain infarct. Echocardiographic predictors, recurrence, and prevention
    • Hanna JP, Sun JP, Furlan AJ, et al. Patent foramen ovale and brain infarct. Echocardiographic predictors, recurrence, and prevention. Stroke 1994;25:782.
    • (1994) Stroke , vol.25 , pp. 782
    • Hanna, J.P.1    Sun, J.P.2    Furlan, A.J.3
  • 2
    • 0029084846 scopus 로고
    • Paradoxical embolism: An underrecognized problem
    • Ward R, Jones D, Haponik EF. Paradoxical embolism: an underrecognized problem. Chest 1995;108:549.
    • (1995) Chest , vol.108 , pp. 549
    • Ward, R.1    Jones, D.2    Haponik, E.F.3
  • 3
    • 0034711135 scopus 로고    scopus 로고
    • Interatrial septal abnormalities and stroke: A meta-analysis of casecontrol studies
    • Overell JR, Bone I, Lees KR. Interatrial septal abnormalities and stroke: a meta-analysis of casecontrol studies. Neurology 2000;55:1172.
    • (2000) Neurology , vol.55 , pp. 1172
    • Overell, J.R.1    Bone, I.2    Lees, K.R.3
  • 4
    • 0026071709 scopus 로고
    • Superiority of transesophageal echocardiography in detecting cardiac source of embolism in patients with cerebral ischemia of uncertain etiology
    • Pearson AC, Labovitz AJ, Tatineni S, et al. Superiority of transesophageal echocardiography in detecting cardiac source of embolism in patients with cerebral ischemia of uncertain etiology. J Am Coll Cardiol 1991;17:66.
    • (1991) J Am Coll Cardiol , vol.17 , pp. 66
    • Pearson, A.C.1    Labovitz, A.J.2    Tatineni, S.3
  • 5
    • 0027994381 scopus 로고
    • Comparison of transesophageal and transthoracic echocardiography with contrast and color flow Doppler in the detection of patent foramen ovale
    • DOI 10.1016/0002-8703(94)90626-2
    • Belkin RN, Pollack BD, Ruggiero ML, et al. Comparison of transesophageal and transthoracic echocardiography with contrast and color flow Doppler in the detection of patent foramen ovale. Am Heart J 1994;128:520. (Pubitemid 24298305)
    • (1994) American Heart Journal , vol.128 , Issue.3 , pp. 520-525
    • Belkin, R.N.1    Pollack, B.D.2    Ruggiero, M.L.3    Alas, L.L.4    Tatini, U.5
  • 6
    • 0033773515 scopus 로고    scopus 로고
    • Detection of right-to-left shunt with ultrasound contrast agent and transcranial Doppler sonography
    • Jauss M, Zanette E. Detection of right-to-left shunt with ultrasound contrast agent and transcranial Doppler sonography. Cerebrovasc Dis 2000;10:490.
    • (2000) Cerebrovasc Dis , vol.10 , pp. 490
    • Jauss, M.1    Zanette, E.2
  • 7
    • 0027466066 scopus 로고
    • The cough test is superior to the Valsalva maneuver in the delineation of right-to-left shunting through a patent foramen ovale during contrast transesophageal echocardiography
    • DOI 10.1016/0002-8703(93)90073-I
    • Stoddard MF, Keedy DL, Dawkins PR. The cough test is superior to the Valsalva maneuver in the delineation of right-to-left shunting through a patent foramen ovale during contrast transesophageal echocardiography. Am Heart J 1993;125:185. (Pubitemid 23021642)
    • (1993) American Heart Journal , vol.125 , Issue.1 , pp. 185-189
    • Stoddard, M.F.1    Keedy, D.L.2    Dawkins, P.R.3
  • 9
    • 0027324975 scopus 로고
    • Comparison of diagnostic techniques for the detection of a patent foramen ovale in stroke patients
    • Di Tullio M, Sacco RL, Venketasubramanian N, et al. Comparison of diagnostic techniques for the detection of a patent foramen ovale in stroke patients. Stroke 1993;24:1020. (Pubitemid 23201460)
    • (1993) Stroke , vol.24 , Issue.7 , pp. 1020-1024
    • Di Tullio, M.1    Sacco, R.L.2    Venketasubramanian, N.3    Sherman, D.4    Mohr, J.P.5    Homma, S.6
  • 10
    • 0027932157 scopus 로고
    • Comparison of transcranial contrast Doppler sonography and transesophageal contrast echocardiography for the detection of patent foramen ovale in young stroke patients
    • DOI 10.1016/0002-9149(94)90407-3
    • Job FP, Ringelstein EB, Grafen Y, et al. Comparison of transcranial contrast Doppler sonography and transesophageal contrast echocardiography for the detection of patent foramen ovale in young stroke patients. Am J Cardiol 1994;74:381. (Pubitemid 24253477)
    • (1994) American Journal of Cardiology , vol.74 , Issue.4 , pp. 381-384
    • Job, F.P.1    Ringelstein, E.B.2    Grafen, Y.3    Flachskampf, F.A.4    Doherty, C.5    Stockmanns, A.6    Hanrath, P.7
  • 11
    • 0001735680 scopus 로고
    • Validation of transcranial Doppler sonography in the assessment of patent foramen ovale
    • Anzola GP, Renaldini E, Magoni M, et al. Validation of transcranial Doppler sonography in the assessment of patent foramen ovale. Cerebrovasc Dis 1995;5:194.
    • (1995) Cerebrovasc Dis , vol.5 , pp. 194
    • Anzola, G.P.1    Renaldini, E.2    Magoni, M.3
  • 12
    • 0030481612 scopus 로고    scopus 로고
    • Patent foramen ovale and transcranial Doppler. Comparison of different procedures
    • Zanette EM, Mancini G, De Castro S, et al. Patent foramen ovale and transcranial Doppler. Comparison of different procedures. Stroke 1996;27:2251.
    • (1996) Stroke , vol.27 , pp. 2251
    • Zanette, E.M.1    Mancini, G.2    De Castro, S.3
  • 14
    • 34248366417 scopus 로고    scopus 로고
    • Is transcranial doppler for the detection of venous-to-arterial circulation shunts reproducible?
    • Sastry S, Daly K, Chengodu T, et al. Is transcranial doppler for the detection of venous-to-arterial circulation shunts reproducible? Cerebrovasc Dis 2007;23:424.
    • (2007) Cerebrovasc Dis , vol.23 , pp. 424
    • Sastry, S.1    Daly, K.2    Chengodu, T.3
  • 15
    • 0000182992 scopus 로고
    • Patent foramen ovale: A potential source of cerebral embolism?
    • Schminke U, Ries S, Daffertshofer M, et al. Patent foramen ovale: a potential source of cerebral embolism? Cerebrovasc Dis 1995;5:133.
    • (1995) Cerebrovasc Dis , vol.5 , pp. 133
    • Schminke, U.1    Ries, S.2    Daffertshofer, M.3
  • 16
    • 0028059955 scopus 로고
    • Transesophageal echocardiography and contrast-TCD in the detection of a patent foramen ovale: Experiences with 111 patients
    • Klotzsch C, Janssen G, Berlit P. Transesophageal echocardiography and contrast-TCD in the detection of a patent foramen ovale: experiences with 111 patients. Neurology 1994;44:1603. (Pubitemid 24286633)
    • (1994) Neurology , vol.44 , Issue.9 , pp. 1603-1606
    • Klotzsch, C.1    Janssen, G.2    Berlit, P.3
  • 17
    • 0028082344 scopus 로고
    • Characteristics of patent foramen ovale associated with cryptogenic stroke. A biplane transesophageal echocardiographic study
    • Homma S, Di Tullio MR, Sacco RL, et al. Characteristics of patent foramen ovale associated with cryptogenic stroke. A biplane transesophageal echocardiographic study. Stroke 1994;25:582.
    • (1994) Stroke , vol.25 , pp. 582
    • Homma, S.1    Di Tullio, M.R.2    Sacco, R.L.3
  • 18
    • 0031861858 scopus 로고    scopus 로고
    • The need to quantify right-to-left shunt in acute ischemic stroke a case-control study
    • Serena J, Segura T, Perez-Ayuso MJ, et al. The need to quantify right-to-left shunt in acute ischemic stroke: a case-control study. Stroke 1998;29:1322. (Pubitemid 28300064)
    • (1998) Stroke , vol.29 , Issue.7 , pp. 1322-1328
    • Serena, J.1    Segura, T.2    Perez-Ayuso, M.J.3    Bassaganyas, J.4    Molins, A.5    Davalos, A.6
  • 19
    • 0030816621 scopus 로고    scopus 로고
    • Insufficient and absent acoustic temporal bone window: Potential and limitations of transcranial contrast-enhanced color-coded sonography and contrast-enhanced power-based sonography
    • DOI 10.1016/S0301-5629(97)00047-1, PII S0301562997000471
    • Postert T, Federlein J, Przuntek H, et al. Insufficient and absent acoustic temporal bone window: potential and limitations of transcranial contrast-enhanced color-coded sonography and contrast-enhanced power-based sonography. Ultrasound Med Biol 1997;23:857. (Pubitemid 27349533)
    • (1997) Ultrasound in Medicine and Biology , vol.23 , Issue.6 , pp. 857-862
    • Postert, T.1    Federlein, J.2    Przuntek, H.3    Buttner, T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.