메뉴 건너뛰기




Volumn 18, Issue 5, 2009, Pages 343-348

Transcranial Doppler and Transesophageal Echocardiography: Comparison of Both Techniques and Prospective Clinical Relevance of Transcranial Doppler in Patent Foramen Ovale Detection

Author keywords

patent foramen ovale; right to left shunt; stroke; Transcranial Doppler; transesophageal echocardiography

Indexed keywords

ARTICLE; CLINICAL ASSESSMENT; CLINICAL FEATURE; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DOPPLER ECHOGRAPHY; FEMALE; GOLD STANDARD; HUMAN; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; NEUROSURGERY; PATENT FORAMEN OVALE; PRIORITY JOURNAL; SENSITIVITY AND SPECIFICITY; STANDARD; TRANSESOPHAGEAL ECHOCARDIOGRAPHY;

EID: 69149099372     PISSN: 10523057     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jstrokecerebrovasdis.2008.12.001     Document Type: Article
Times cited : (72)

References (42)
  • 1
    • 0021352808 scopus 로고
    • Incidence and size of patent foramen ovale during the first 10 decades of life: An autopsy study of 965 normal hearts
    • Hagen P.T., Scholz D.G., and Edwards W.D. Incidence and size of patent foramen ovale during the first 10 decades of life: An autopsy study of 965 normal hearts. Mayo Clin Proc 59 (1984) 17-20
    • (1984) Mayo Clin Proc , vol.59 , pp. 17-20
    • Hagen, P.T.1    Scholz, D.G.2    Edwards, W.D.3
  • 2
    • 0035009913 scopus 로고    scopus 로고
    • Patent foramen ovale and cryptogenic cerebral infarction [review]
    • McGaw D., and Harper R. Patent foramen ovale and cryptogenic cerebral infarction [review]. Intern Med J 31 (2001) 42-47
    • (2001) Intern Med J , vol.31 , pp. 42-47
    • McGaw, D.1    Harper, R.2
  • 3
    • 0034711135 scopus 로고    scopus 로고
    • Interatrial septal abnormalities and stroke: A meta-analysis of case-control studies
    • Overell J.R., Bone I., and Lees K.R. Interatrial septal abnormalities and stroke: A meta-analysis of case-control studies. Neurology 24 (2000) 1172-1179
    • (2000) Neurology , vol.24 , pp. 1172-1179
    • Overell, J.R.1    Bone, I.2    Lees, K.R.3
  • 4
    • 0027371189 scopus 로고
    • Atrial septal aneurysm and patent foramen ovale as risk factors for cryptogenic stroke in patients less than 55 years of age: A study using transesophageal echocardiography
    • Cabanes L., Mas J.L., Cohen A., et al. Atrial septal aneurysm and patent foramen ovale as risk factors for cryptogenic stroke in patients less than 55 years of age: A study using transesophageal echocardiography. Stroke 24 (1993) 1865-1873
    • (1993) Stroke , vol.24 , pp. 1865-1873
    • Cabanes, L.1    Mas, J.L.2    Cohen, A.3
  • 5
    • 0026639871 scopus 로고    scopus 로고
    • Patent foramen ovale as a risk factor for cryptogenic stroke. Ann Intern Med 1192;15:461-465
    • Di Tullio M, Sacco RL, Gopal A, et al. Patent foramen ovale as a risk factor for cryptogenic stroke. Ann Intern Med 1192;15:461-465.
    • Di Tullio, M.1    Sacco, R.L.2    Gopal, A.3    et al4
  • 6
    • 0027441338 scopus 로고
    • Patent foramen ovale: Is stroke due to paradoxical embolism?
    • Ranoux D., Cohen A., Cabanes L., et al. Patent foramen ovale: Is stroke due to paradoxical embolism?. Stroke 24 (1993) 31-34
    • (1993) Stroke , vol.24 , pp. 31-34
    • Ranoux, D.1    Cohen, A.2    Cabanes, L.3
  • 7
    • 0033549030 scopus 로고    scopus 로고
    • Potential source of cerebral embolism in migraine with aura: A transcranial Doppler study
    • Anzola G.P., Magoni M., Guindani M., et al. Potential source of cerebral embolism in migraine with aura: A transcranial Doppler study. Neurology 12 (1999) 1622-1625
    • (1999) Neurology , vol.12 , pp. 1622-1625
    • Anzola, G.P.1    Magoni, M.2    Guindani, M.3
  • 8
    • 0036184441 scopus 로고    scopus 로고
    • Patent foramen ovale, a possible cause of symptomatic migraine: A study of 74 patients with acute ischemic stroke
    • Sztajzel R., Genoud D., Roth S., et al. Patent foramen ovale, a possible cause of symptomatic migraine: A study of 74 patients with acute ischemic stroke. Cerebrovasc Dis 13 (2002) 102-106
    • (2002) Cerebrovasc Dis , vol.13 , pp. 102-106
    • Sztajzel, R.1    Genoud, D.2    Roth, S.3
  • 9
    • 0026049389 scopus 로고
    • Patent foramen ovale associated with platypnea and orthodeoxia
    • Sorrentino M., and Resnekov L. Patent foramen ovale associated with platypnea and orthodeoxia. Chest 100 (1991) 1157-1158
    • (1991) Chest , vol.100 , pp. 1157-1158
    • Sorrentino, M.1    Resnekov, L.2
  • 10
    • 12844264134 scopus 로고    scopus 로고
    • Patent foramen ovale and diving
    • Germonpre P. Patent foramen ovale and diving. Cardiol Clin 23 (2005) 97-104
    • (2005) Cardiol Clin , vol.23 , pp. 97-104
    • Germonpre, P.1
  • 11
    • 0031041076 scopus 로고    scopus 로고
    • Cohort study of multiple brain lesions in sport divers: Role of a patent foramen ovale
    • Knauth M, Ries S, Pohimann S, et al. Cohort study of multiple brain lesions in sport divers: Role of a patent foramen ovale. BMJ 1197;8:701-705.
    • BMJ , vol.1197 , Issue.8 , pp. 701-705
    • Knauth, M.1    Ries, S.2    Pohimann, S.3    et al4
  • 12
    • 0033775154 scopus 로고    scopus 로고
    • Transcranial Doppler ultrasonography as a screening technique for detection of a patent foramen ovale before surgery in the sitting position
    • Stendel R., Gramm H.J., Schroeder K., et al. Transcranial Doppler ultrasonography as a screening technique for detection of a patent foramen ovale before surgery in the sitting position. Anesthesiology 93 (2000) 971-975
    • (2000) Anesthesiology , vol.93 , pp. 971-975
    • Stendel, R.1    Gramm, H.J.2    Schroeder, K.3
  • 13
    • 0029931512 scopus 로고    scopus 로고
    • Diagnosis of patent foramen ovale by transesophageal echocardiography and correlation with autopsy findings
    • Schneider B., Zienkiewicz T., Jansen V., et al. Diagnosis of patent foramen ovale by transesophageal echocardiography and correlation with autopsy findings. Am J Cardiol 1 (1996) 1202-1209
    • (1996) Am J Cardiol , vol.1 , pp. 1202-1209
    • Schneider, B.1    Zienkiewicz, T.2    Jansen, V.3
  • 14
    • 0026733037 scopus 로고
    • Diagnosis of patent foramen ovale by transesophageal echocardiography and association with cerebral and peripheral embolic events
    • Hausmann D., Mugge A., Becht I., et al. Diagnosis of patent foramen ovale by transesophageal echocardiography and association with cerebral and peripheral embolic events. Am J Cardiol 1 (1992) 668-672
    • (1992) Am J Cardiol , vol.1 , pp. 668-672
    • Hausmann, D.1    Mugge, A.2    Becht, I.3
  • 15
    • 0026071709 scopus 로고
    • Superiority of transesophageal echocardiography in detecting cardiac source of embolism in patients with cerebral ischemia of uncertain etiology
    • Pearson A.C., Labovitz A.J., Tatineni S., et al. Superiority of transesophageal echocardiography in detecting cardiac source of embolism in patients with cerebral ischemia of uncertain etiology. J Am Coll Cardiol 17 (1991) 66-72
    • (1991) J Am Coll Cardiol , vol.17 , pp. 66-72
    • Pearson, A.C.1    Labovitz, A.J.2    Tatineni, S.3
  • 16
    • 0025204697 scopus 로고
    • Safety and usefulness of transesophageal echocardiography in persons aged greater than or equal to 70 years
    • Ofili E.O., and Rich M.W. Safety and usefulness of transesophageal echocardiography in persons aged greater than or equal to 70 years. Am J Cardiol 15 (1990) 1279-1280
    • (1990) Am J Cardiol , vol.15 , pp. 1279-1280
    • Ofili, E.O.1    Rich, M.W.2
  • 17
    • 0028013222 scopus 로고
    • Atrial septal aneurysm as a potential source of neurological ischemic events [review]
    • Zabalgoitia M., Norris L.P., and Garcia M. Atrial septal aneurysm as a potential source of neurological ischemic events [review]. Am J Card Imaging 8 (1994) 39-44
    • (1994) Am J Card Imaging , vol.8 , pp. 39-44
    • Zabalgoitia, M.1    Norris, L.P.2    Garcia, M.3
  • 18
    • 0029024221 scopus 로고
    • The incidence of patent foramen ovale in 1,000 consecutive patients: A contrast transesophageal echocardiography study
    • Fisher D.C., Fisher E.A., Budd J.H., et al. The incidence of patent foramen ovale in 1,000 consecutive patients: A contrast transesophageal echocardiography study. Chest 107 (1995) 1504-1509
    • (1995) Chest , vol.107 , pp. 1504-1509
    • Fisher, D.C.1    Fisher, E.A.2    Budd, J.H.3
  • 19
    • 0026331863 scopus 로고
    • Transcranial Doppler ultrasound identifies patients with right-to-left cardiac or pulmonary shunts
    • Chimowitz M.I., Nemec J.J., Marwick T.H., et al. Transcranial Doppler ultrasound identifies patients with right-to-left cardiac or pulmonary shunts. Neurology 41 (1991) 1902-1904
    • (1991) Neurology , vol.41 , pp. 1902-1904
    • Chimowitz, M.I.1    Nemec, J.J.2    Marwick, T.H.3
  • 20
    • 0027416414 scopus 로고
    • Transcranial Doppler with contrast injection for the detection of patent foramen ovale in stroke patients
    • Di Tullio M., Sacco R.L., Massaro A., et al. Transcranial Doppler with contrast injection for the detection of patent foramen ovale in stroke patients. Int J Card Imaging 9 (1993) 1-5
    • (1993) Int J Card Imaging , vol.9 , pp. 1-5
    • Di Tullio, M.1    Sacco, R.L.2    Massaro, A.3
  • 21
    • 0028337578 scopus 로고
    • A comparison of transesophageal echocardiography and transcranial Doppler sonography with contrast medium for detection of patent foramen ovale
    • Jauss M., Kaps M., Keberle M., et al. A comparison of transesophageal echocardiography and transcranial Doppler sonography with contrast medium for detection of patent foramen ovale. Stroke 25 (1994) 1265-1267
    • (1994) Stroke , vol.25 , pp. 1265-1267
    • Jauss, M.1    Kaps, M.2    Keberle, M.3
  • 22
    • 0027932157 scopus 로고
    • Comparison of transcranial contrast Doppler sonography and transesophageal contrast echocardiography for the detection of patent foramen ovale in young stroke patients
    • Job F.P., Ringelstein E.B., Grafen Y., et al. Comparison of transcranial contrast Doppler sonography and transesophageal contrast echocardiography for the detection of patent foramen ovale in young stroke patients. Am J Cardiol 15 (1994) 381-384
    • (1994) Am J Cardiol , vol.15 , pp. 381-384
    • Job, F.P.1    Ringelstein, E.B.2    Grafen, Y.3
  • 23
    • 0345062319 scopus 로고    scopus 로고
    • Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts: Comparison of different procedures and different contrast agents
    • Droste D.W., Kriete J.U., Stypmann J., et al. Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts: Comparison of different procedures and different contrast agents. Stroke 30 (1999) 1827-1832
    • (1999) Stroke , vol.30 , pp. 1827-1832
    • Droste, D.W.1    Kriete, J.U.2    Stypmann, J.3
  • 24
    • 0030788936 scopus 로고    scopus 로고
    • Complementarity of contrast transcranial Doppler and contrast transesophageal echocardiography for the detection of patent foramen ovale in stroke patients
    • Devuyst G., Despland P.A., Bogousslavsky J., et al. Complementarity of contrast transcranial Doppler and contrast transesophageal echocardiography for the detection of patent foramen ovale in stroke patients. Eur Neurol 38 (1997) 21-25
    • (1997) Eur Neurol , vol.38 , pp. 21-25
    • Devuyst, G.1    Despland, P.A.2    Bogousslavsky, J.3
  • 25
    • 0030786384 scopus 로고    scopus 로고
    • Simultaneous bilateral contrast transcranial Doppler monitoring in patients with intracardiac and intrapulmonary shunts
    • Horner S., Ni X.S., Weihs W., et al. Simultaneous bilateral contrast transcranial Doppler monitoring in patients with intracardiac and intrapulmonary shunts. J Neurol Sci 1 (1997) 49-57
    • (1997) J Neurol Sci , vol.1 , pp. 49-57
    • Horner, S.1    Ni, X.S.2    Weihs, W.3
  • 26
    • 0001735680 scopus 로고
    • Validation of transcranial Doppler sonography in the assessment of patent foramen ovale
    • Anzola G.P., Renaldini E., Magoni M., et al. Validation of transcranial Doppler sonography in the assessment of patent foramen ovale. Cerebrovasc Dis 5 (1995) 194-198
    • (1995) Cerebrovasc Dis , vol.5 , pp. 194-198
    • Anzola, G.P.1    Renaldini, E.2    Magoni, M.3
  • 27
    • 0032899810 scopus 로고    scopus 로고
    • Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts: Reproducibility, comparison of 2 agents, and distribution of microemboli
    • Droste D.W., Reisener M., Kemeny V., et al. Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts: Reproducibility, comparison of 2 agents, and distribution of microemboli. Stroke 30 (1999) 1014-1018
    • (1999) Stroke , vol.30 , pp. 1014-1018
    • Droste, D.W.1    Reisener, M.2    Kemeny, V.3
  • 28
    • 0033773515 scopus 로고    scopus 로고
    • Detection of right-to-left shunt with ultrasound contrast agent and transcranial Doppler sonography
    • Jauss M., and Zanette E. Detection of right-to-left shunt with ultrasound contrast agent and transcranial Doppler sonography. Cerebrovasc Dis 10 (2000) 490-496
    • (2000) Cerebrovasc Dis , vol.10 , pp. 490-496
    • Jauss, M.1    Zanette, E.2
  • 29
    • 0033067564 scopus 로고    scopus 로고
    • Methodological parameters influence the detection of right-to-left shunts by contrast transcranial Doppler ultrasonography
    • Schwarze J.J., Sander D., Kukla C., et al. Methodological parameters influence the detection of right-to-left shunts by contrast transcranial Doppler ultrasonography. Stroke 30 (1999) 1234-1239
    • (1999) Stroke , vol.30 , pp. 1234-1239
    • Schwarze, J.J.1    Sander, D.2    Kukla, C.3
  • 30
    • 0027324975 scopus 로고
    • Comparison of diagnostic techniques for the detection of a patent foramen ovale in stroke patients
    • Di Tullio M.R., Sacco R.L., Venketasubramanian N., et al. Comparison of diagnostic techniques for the detection of a patent foramen ovale in stroke patients. Stroke 24 (1993) 1020-1024
    • (1993) Stroke , vol.24 , pp. 1020-1024
    • Di Tullio, M.R.1    Sacco, R.L.2    Venketasubramanian, N.3
  • 31
    • 0026052264 scopus 로고
    • Atrial septal aneurysm and stroke: A transesophageal study
    • Pearson A., Nagelhout D., Castello R., et al. Atrial septal aneurysm and stroke: A transesophageal study. J Am Coll Cardiol 18 (1991) 1223-1229
    • (1991) J Am Coll Cardiol , vol.18 , pp. 1223-1229
    • Pearson, A.1    Nagelhout, D.2    Castello, R.3
  • 32
    • 0031751103 scopus 로고    scopus 로고
    • Migraine with aura and right-to-left shunt on transcranial Doppler: A case-control study
    • Del Sette M., Angeli S., Leandri M., et al. Migraine with aura and right-to-left shunt on transcranial Doppler: A case-control study. Cerebrovasc Dis 8 (1998) 327-330
    • (1998) Cerebrovasc Dis , vol.8 , pp. 327-330
    • Del Sette, M.1    Angeli, S.2    Leandri, M.3
  • 33
    • 25144519137 scopus 로고    scopus 로고
    • Prevalence of patent foramen ovale in a large series of patients with migraine with aura, migraine without aura and cluster headache, and relationship with clinical phenotype
    • Dalla Volta G., Guindani M., Zavarise P., et al. Prevalence of patent foramen ovale in a large series of patients with migraine with aura, migraine without aura and cluster headache, and relationship with clinical phenotype. J Headache Pain 6 (2005) 328-330
    • (2005) J Headache Pain , vol.6 , pp. 328-330
    • Dalla Volta, G.1    Guindani, M.2    Zavarise, P.3
  • 34
    • 0032717814 scopus 로고    scopus 로고
    • Transcranial Doppler of a paradoxical brain embolism associated with a pulmonary arteriovenous fistula
    • Kimura K., Minematsu K., Wada K., et al. Transcranial Doppler of a paradoxical brain embolism associated with a pulmonary arteriovenous fistula. AJNR Am J Neuroradiol 20 (1999) 1881-1884
    • (1999) AJNR Am J Neuroradiol , vol.20 , pp. 1881-1884
    • Kimura, K.1    Minematsu, K.2    Wada, K.3
  • 35
    • 0019837693 scopus 로고
    • Paradoxical cerebral air embolism without an intracardiac septal defect: Case report
    • Marquez J., Sladen A., Gendell H., et al. Paradoxical cerebral air embolism without an intracardiac septal defect: Case report. J Neurosurg 55 (1981) 997-1000
    • (1981) J Neurosurg , vol.55 , pp. 997-1000
    • Marquez, J.1    Sladen, A.2    Gendell, H.3
  • 36
    • 0034269162 scopus 로고    scopus 로고
    • Case 3, pulmonary arteriovenous malformation (PAVM): Paradoxical embolism through the arteriovenous fistula can cause brain abscess and infarct
    • Natarajan K., Khabiri H., and Jung S. Case 3, pulmonary arteriovenous malformation (PAVM): Paradoxical embolism through the arteriovenous fistula can cause brain abscess and infarct. AJR Am J Roentgenol 175 (2000) 854-858
    • (2000) AJR Am J Roentgenol , vol.175 , pp. 854-858
    • Natarajan, K.1    Khabiri, H.2    Jung, S.3
  • 37
    • 0030481612 scopus 로고    scopus 로고
    • Patent foramen ovale and transcranial Doppler: Comparison of different procedures
    • Zanette E.M., Mancini G., De Castro S., et al. Patent foramen ovale and transcranial Doppler: Comparison of different procedures. Stroke 27 (1996) 2251-2255
    • (1996) Stroke , vol.27 , pp. 2251-2255
    • Zanette, E.M.1    Mancini, G.2    De Castro, S.3
  • 38
    • 0027249379 scopus 로고
    • Vascular distribution of paradoxical emboli by transcranial Doppler
    • Venketasubramanian N., Sacco R.L., Di Tullio M., et al. Vascular distribution of paradoxical emboli by transcranial Doppler. Neurology 43 (1993) 1533-1535
    • (1993) Neurology , vol.43 , pp. 1533-1535
    • Venketasubramanian, N.1    Sacco, R.L.2    Di Tullio, M.3
  • 39
    • 2442571141 scopus 로고    scopus 로고
    • The identification of right-to-left shunts using contrast transcranial Doppler ultrasound: Performance and interpretation modalities, and absence of a significant side difference of cardiac micro-emboli
    • Droste D.W., Lakemeier H., Ritter M., et al. The identification of right-to-left shunts using contrast transcranial Doppler ultrasound: Performance and interpretation modalities, and absence of a significant side difference of cardiac micro-emboli. Neurol Res 26 (2004) 325-330
    • (2004) Neurol Res , vol.26 , pp. 325-330
    • Droste, D.W.1    Lakemeier, H.2    Ritter, M.3
  • 40
    • 32944463757 scopus 로고    scopus 로고
    • Comparison of transthoracic echocardiography using second harmonic imaging, transcranial Doppler and transesophageal echocardiography for the detection of patent foramen ovale in stroke patients
    • Souteyrand G., Motreff P., Lusson J.R., et al. Comparison of transthoracic echocardiography using second harmonic imaging, transcranial Doppler and transesophageal echocardiography for the detection of patent foramen ovale in stroke patients. Eur J Echocardiogr 7 (2006) 147-154
    • (2006) Eur J Echocardiogr , vol.7 , pp. 147-154
    • Souteyrand, G.1    Motreff, P.2    Lusson, J.R.3
  • 41
    • 33746499061 scopus 로고    scopus 로고
    • Feasibility and clinical impact of live three-dimensional echocardiography in the management of congenital heart disease
    • De Castro S., Caselli S., Papetti F., et al. Feasibility and clinical impact of live three-dimensional echocardiography in the management of congenital heart disease. Echocardiography 23 (2006) 553-561
    • (2006) Echocardiography , vol.23 , pp. 553-561
    • De Castro, S.1    Caselli, S.2    Papetti, F.3
  • 42
    • 0037177070 scopus 로고    scopus 로고
    • "Economy class" stroke syndrome?
    • Isayev Y., Chan R.K., and Pullicino P.M. "Economy class" stroke syndrome?. Neurology 26 (2002) 960-961
    • (2002) Neurology , vol.26 , pp. 960-961
    • Isayev, Y.1    Chan, R.K.2    Pullicino, P.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.