메뉴 건너뛰기




Volumn 64, Issue 2, 2011, Pages 133-139

Diagnosis and quantification of patent foramen ovale. Which is the reference technique? Simultaneous study with transcranial doppler, transthoracic and transesophageal echocardiography;Diagnóstico y cuantificación del foramen oval permeable. ¿cuál es la técnica de referencia? Estudio simultáneo con Doppler transcraneal, ecocardiografía transtorácica y transesofágica

Author keywords

Echocardiography; Patent foramen ovale; Transcranial Doppler

Indexed keywords

SODIUM CHLORIDE;

EID: 79951720906     PISSN: 03008932     EISSN: 15792242     Source Type: Journal    
DOI: 10.1016/j.recesp.2010.10.009     Document Type: Article
Times cited : (76)

References (37)
  • 1
    • 0034668078 scopus 로고    scopus 로고
    • The association between the diameter of a patent foramen ovale and the risk of embolic cerebrovascular events
    • H.W. Schuchlenz, W. Weihs, S. Horner, and F. Quehenberger The association between the diameter of a patent foramen ovale and the risk of embolic cerebrovascular events Am J Med. 109 2000 456 462
    • (2000) Am J Med. , vol.109 , pp. 456-462
    • Schuchlenz, H.W.1    Weihs, W.2    Horner, S.3    Quehenberger, F.4
  • 2
    • 0031041076 scopus 로고    scopus 로고
    • Cohort study of multiple brain lesions in sport divers: Role of a patent foramen ovale
    • M. Knauth, S. Ries, S. Pohimann, T. Kerby, M. Forsting, and M. Daffertshofer Cohort study of multiple brain lesions in sport divers: role of a patent foramen ovale BMJ. 314 1997 701 705
    • (1997) BMJ , vol.314 , pp. 701-705
    • Knauth, M.1    Ries, S.2    Pohimann, S.3    Kerby, T.4    Forsting, M.5    Daffertshofer, M.6
  • 3
    • 0033994080 scopus 로고    scopus 로고
    • Atrial right-to-left shunting causing severe hipoxaemia despite normal right-sided pressures: Report of 11 consecutive cases corrected by percutaneous closure
    • F. Godart, C. Rey, A. Prat, A. Vincentelli, A. Chmait, and C. Francart Atrial right-to-left shunting causing severe hipoxaemia despite normal right-sided pressures: report of 11 consecutive cases corrected by percutaneous closure Eur Heart J. 21 2000 483 489
    • (2000) Eur Heart J. , vol.21 , pp. 483-489
    • Godart, F.1    Rey, C.2    Prat, A.3    Vincentelli, A.4    Chmait, A.5    Francart, C.6
  • 5
    • 0034840351 scopus 로고    scopus 로고
    • Patent foramen ovale: A review of associated conditions and the impact of physiological size
    • E.K. Kerut, W.T. Norfleet, G.D. Plotnick, and T.D. Giles Patent foramen ovale: a review of associated conditions and the impact of physiological size J Am Coll Cardiol. 38 2001 613 623
    • (2001) J Am Coll Cardiol. , vol.38 , pp. 613-623
    • Kerut, E.K.1    Norfleet, W.T.2    Plotnick, G.D.3    Giles, T.D.4
  • 6
    • 58149334924 scopus 로고    scopus 로고
    • Recurrent stroke and massive right-to-left shunt. Results from the prospective spanish multicenter (CODICIA) Study
    • J. Serena, J. Martí-Fbregas, E. Santamarina, J.J. Rodríguez, M.J. Pérez-Ayuso, and J. Masjuán Recurrent stroke and massive right-to-left shunt. Results from the prospective spanish multicenter (CODICIA) Study Stroke. 39 2008 3131 3136
    • (2008) Stroke. , vol.39 , pp. 3131-3136
    • Serena, J.1    Martí-Fbregas, J.2    Santamarina, E.3    Rodríguez, J.J.4    Pérez-Ayuso, M.J.5    Masjuán, J.6
  • 7
    • 0042121204 scopus 로고    scopus 로고
    • Prevalencia de foramen oval permeable en pacientes jóvenes con accidente isquémico cerebral de causa desconocida
    • D. Mesa, M. Franco, J. Suárez de Lezo, J. Muñoz, C. Rus, and M. Delgado Prevalencia de foramen oval permeable en pacientes jóvenes con accidente isquémico cerebral de causa desconocida Rev Esp Cardiol. 56 2003 662 668
    • (2003) Rev Esp Cardiol. , vol.56 , pp. 662-668
    • Mesa, D.1    Franco, M.2    Suárez De Lezo, J.3    Muñoz, J.4    Rus, C.5    Delgado, M.6
  • 8
    • 70449482411 scopus 로고    scopus 로고
    • Catheter-based closure of the patent foramen ovale
    • B. Meier Catheter-based closure of the patent foramen ovale Circulation. 120 2009 1837 1841
    • (2009) Circulation. , vol.120 , pp. 1837-1841
    • Meier, B.1
  • 9
    • 0037271795 scopus 로고    scopus 로고
    • Patent foramen ovale: Anatomy versus pathophysiology. Which determines stroke risk?
    • A. Natanzon, and M.E. Goldman Patent foramen ovale: anatomy versus pathophysiology. Which determines stroke risk? J Am Soc Echocardiogr. 16 2003 71 76
    • (2003) J Am Soc Echocardiogr. , vol.16 , pp. 71-76
    • Natanzon, A.1    Goldman, M.E.2
  • 11
    • 31944446347 scopus 로고    scopus 로고
    • A critical review of patent foramen ovale. Detection using saline contraste echocardiography: When bubbles lie
    • T. Woods, and A. Patel A critical review of patent foramen ovale. Detection using saline contraste echocardiography: when bubbles lie J Am Soc Echocardiogr. 19 2006 215 222
    • (2006) J Am Soc Echocardiogr. , vol.19 , pp. 215-222
    • Woods, T.1    Patel, A.2
  • 12
    • 33746572045 scopus 로고    scopus 로고
    • Procol for optimal detection and exclusion of a patent foramen ovale using transthoracic echocardiography with agitated saline microbubbles
    • R.R. Attaran, I. Ata, V. Kudithipudi, L. Foster, and V.L. Sorrell Procol for optimal detection and exclusion of a patent foramen ovale using transthoracic echocardiography with agitated saline microbubbles Echocardiography. 23 2006 616 622
    • (2006) Echocardiography. , vol.23 , pp. 616-622
    • Attaran, R.R.1    Ata, I.2    Kudithipudi, V.3    Foster, L.4    Sorrell, V.L.5
  • 13
    • 0036713359 scopus 로고    scopus 로고
    • Optimizing the technique of contrast transcranial Doppler ultrasound in the detection of right-to-left shunts
    • D.W. Droste, S. Lakemeier, T. Wichter, J. Stypmann, R. Dittrich, and M. Ritter Optimizing the technique of contrast transcranial Doppler ultrasound in the detection of right-to-left shunts Stroke. 33 2002 2211 2216
    • (2002) Stroke. , vol.33 , pp. 2211-2216
    • Droste, D.W.1    Lakemeier, S.2    Wichter, T.3    Stypmann, J.4    Dittrich, R.5    Ritter, M.6
  • 14
    • 0345325556 scopus 로고    scopus 로고
    • Transthoracic echocardiography using second harmonic imaging diagnostic alternative to transesophageal echocardiography for atrial right to left shunt in patients with cerebral embolic events
    • H.P. Kühl, R. Hoffmann, M.W. Merx, A. Franke, C. Klötzsch, and W. Lepper Transthoracic echocardiography using second harmonic imaging diagnostic alternative to transesophageal echocardiography for atrial right to left shunt in patients with cerebral embolic events J Am Coll Cardiol. 34 1999 1823 1830
    • (1999) J Am Coll Cardiol. , vol.34 , pp. 1823-1830
    • Kühl, H.P.1    Hoffmann, R.2    Merx, M.W.3    Franke, A.4    Klötzsch, C.5    Lepper, W.6
  • 15
    • 32944463757 scopus 로고    scopus 로고
    • Comparison of transthoracic echocardiography using second harmonic imaging, transcranial Doppler and transesophageal echocardiography fort he detection of patent foramen ovale in stroke patients
    • G. Souteyrand, P. Motreff, J.R. Lusson, R. Rodríguez, E. Geoffroy, and C. Dauphin Comparison of transthoracic echocardiography using second harmonic imaging, transcranial Doppler and transesophageal echocardiography fort he detection of patent foramen ovale in stroke patients Eur J Echocardiogr. 7 2006 147 154
    • (2006) Eur J Echocardiogr. , vol.7 , pp. 147-154
    • Souteyrand, G.1    Motreff, P.2    Lusson, J.R.3    Rodríguez, R.4    Geoffroy, E.5    Dauphin, C.6
  • 16
    • 0034565904 scopus 로고    scopus 로고
    • Comparison of transthoracic echocardiography with second harmonic imaging with transesophageal echocardiography in the detection of right to left shunts
    • G. Van Camp, P. Franken, P. Melis, B. Cosyns, D. Schoors, and J.L. Vanoverschelde Comparison of transthoracic echocardiography with second harmonic imaging with transesophageal echocardiography in the detection of right to left shunts Am J Cardiol. 86 2000 1284 1287
    • (2000) Am J Cardiol. , vol.86 , pp. 1284-1287
    • Van Camp, G.1    Franken, P.2    Melis, P.3    Cosyns, B.4    Schoors, D.5    Vanoverschelde, J.L.6
  • 17
    • 11044221169 scopus 로고    scopus 로고
    • Second harmonic transthoracic echocardiography: The new reference screening method fort he detection of patent foramen ovale
    • C. Daniels, C. Weytjens, B. Cosyns, D. Schoors, J. De Sutter, and B. Paelinck Second harmonic transthoracic echocardiography: the new reference screening method fort he detection of patent foramen ovale Eur J Echocardiogr. 5 2004 449 452
    • (2004) Eur J Echocardiogr. , vol.5 , pp. 449-452
    • Daniels, C.1    Weytjens, C.2    Cosyns, B.3    Schoors, D.4    De Sutter, J.5    Paelinck, B.6
  • 18
    • 0037242921 scopus 로고    scopus 로고
    • Association between atrial septal aneurysm and patent foramen ovale in young patients with recent stroke and normal carotid arteries
    • A.V. Mattioli, L. Bonetti, M. Aquilina, A. Olidani, C. Longhini, and G. Mattioli Association between atrial septal aneurysm and patent foramen ovale in young patients with recent stroke and normal carotid arteries Cerebrovasc Dis. 15 2003 4 10
    • (2003) Cerebrovasc Dis. , vol.15 , pp. 4-10
    • Mattioli, A.V.1    Bonetti, L.2    Aquilina, M.3    Olidani, A.4    Longhini, C.5    Mattioli, G.6
  • 19
    • 0028082344 scopus 로고
    • Characteristics of patent foramen ovale associated with cryptogenic stroke: A biplane transesophageal echocardiographic study
    • S. Homma, M.R. Di Tullio, R.L. Sacco, D. Mihalatos, G. Li Mandri, and J.P. Mohr Characteristics of patent foramen ovale associated with cryptogenic stroke: a biplane transesophageal echocardiographic study Stroke. 25 1994 582 586
    • (1994) Stroke. , vol.25 , pp. 582-586
    • Homma, S.1    Di Tullio, M.R.2    Sacco, R.L.3    Mihalatos, D.4    Li Mandri, G.5    Mohr, J.P.6
  • 20
    • 33749179497 scopus 로고    scopus 로고
    • Comparison of transthoracic echocardiography with harmonic imaging with transoesophageal echocardiography fort he diagnosis of patent foramen ovale
    • J. Trevelyan, and R.P. Steeds Comparison of transthoracic echocardiography with harmonic imaging with transoesophageal echocardiography fort he diagnosis of patent foramen ovale Postgrad Med J. 82 2006 613 614
    • (2006) Postgrad Med J. , vol.82 , pp. 613-614
    • Trevelyan, J.1    Steeds, R.P.2
  • 21
    • 0030481612 scopus 로고    scopus 로고
    • Patent foramen ovale and transcranial Doppler. Comparison of different procedures
    • E.M. Zanette, G. Mancini, S. De Castro, M. Solaro, D. Cartoni, and F. Chiarotti Patent foramen ovale and transcranial Doppler. Comparison of different procedures Stroke. 27 1996 2251 2255
    • (1996) Stroke. , vol.27 , pp. 2251-2255
    • Zanette, E.M.1    Mancini, G.2    De Castro, S.3    Solaro, M.4    Cartoni, D.5    Chiarotti, F.6
  • 22
    • 0026342729 scopus 로고
    • Comparison of transcranial doppler ultrasound and transesophageal contrast echocardiography in the detection of interatrial right-to-left shunts
    • J.J. Nemec, T.H. Marwich, R.J. Lorig, M.B. Davison, M.I. Chimowitz, and H. Litowitz Comparison of transcranial doppler ultrasound and transesophageal contrast echocardiography in the detection of interatrial right-to-left shunts Am J Cardiol. 68 1991 1498 1502
    • (1991) Am J Cardiol. , vol.68 , pp. 1498-1502
    • Nemec, J.J.1    Marwich, T.H.2    Lorig, R.J.3    Davison, M.B.4    Chimowitz, M.I.5    Litowitz, H.6
  • 23
    • 0027932157 scopus 로고
    • Comparison of transcranial contrast doppler sonography and transesophageal contrast echocardiography for the detection of patent foramen ovale in young stroke patients
    • F.P. Job, E.B. Ringelstein, Y. Grafen, F.A. Frachskampf, C. Doherty, and A. Stockmanns Comparison of transcranial contrast doppler sonography and transesophageal contrast echocardiography for the detection of patent foramen ovale in young stroke patients Am J Cardiol. 74 1994 381 384
    • (1994) Am J Cardiol. , vol.74 , pp. 381-384
    • Job, F.P.1    Ringelstein, E.B.2    Grafen, Y.3    Frachskampf, F.A.4    Doherty, C.5    Stockmanns, A.6
  • 24
    • 0026733037 scopus 로고
    • Diagnosis of patent foramen ovale by transesophageal echocardiography and association with cerebral and peripheral embolic events
    • D. Hausmann, A. Mügge, I. Becht, and W.G. Daniel Diagnosis of patent foramen ovale by transesophageal echocardiography and association with cerebral and peripheral embolic events Am J Cardiol. 70 1992 668 672
    • (1992) Am J Cardiol. , vol.70 , pp. 668-672
    • Hausmann, D.1    Mügge, A.2    Becht, I.3    Daniel, W.G.4
  • 25
    • 0026071709 scopus 로고
    • Superiority of transesophageal echocardiography in detecting cardiac source of embolism in patients with cerebral ischemia of uncertain etiology
    • A.C. Pearson, A.J. Labovitz, S. Tatineni, and C.R. Gomez Superiority of transesophageal echocardiography in detecting cardiac source of embolism in patients with cerebral ischemia of uncertain etiology J Am Coll Cardiol. 17 1991 66 72
    • (1991) J Am Coll Cardiol. , vol.17 , pp. 66-72
    • Pearson, A.C.1    Labovitz, A.J.2    Tatineni, S.3    Gomez, C.R.4
  • 26
    • 0345062319 scopus 로고    scopus 로고
    • Contrast transcranial doppler ultrasound in the detection of right-to-left shunts
    • D.W. Droste, J.U. Kriete, J. Stypman, M. Castrucci, T. Wichter, and R. Tietje Contrast transcranial doppler ultrasound in the detection of right-to-left shunts Stroke. 30 1999 1827 1832
    • (1999) Stroke. , vol.30 , pp. 1827-1832
    • Droste, D.W.1    Kriete, J.U.2    Stypman, J.3    Castrucci, M.4    Wichter, T.5    Tietje, R.6
  • 27
    • 65349166276 scopus 로고    scopus 로고
    • Patent foramen ovale: Comparison among diagnostic strategies in cryptogenic stroke and migraine
    • C. Zito, G. Dattilo, G. Oreto, G. Di Bella, A. Lamari, and R. Iudicello Patent foramen ovale: comparison among diagnostic strategies in cryptogenic stroke and migraine Echocardiography. 26 2009 495 502
    • (2009) Echocardiography. , vol.26 , pp. 495-502
    • Zito, C.1    Dattilo, G.2    Oreto, G.3    Di Bella, G.4    Lamari, A.5    Iudicello, R.6
  • 28
    • 0027324975 scopus 로고
    • Comparison of diagnostic techniques for the detection of a patent foramen ovale in stroke patients
    • M. Di Tullio, R.L. Sacco, N. Venketasubramanian, D. Sherman, J.P. Mohr, and S. Homma Comparison of diagnostic techniques for the detection of a patent foramen ovale in stroke patients Stroke. 24 1993 1020 1024 (Pubitemid 23201460)
    • (1993) Stroke , vol.24 , Issue.7 , pp. 1020-1024
    • Di Tullio, M.1    Sacco, R.L.2    Venketasubramanian, N.3    Sherman, D.4    Mohr, J.P.5    Homma, S.6
  • 29
    • 0027994381 scopus 로고
    • Comparison of transesophageal and transthoracic echocardiography with contrast and color flow Doppler in the detection of patent foramen ovale
    • R.N. Belkin, B.D. Pollack, M.L. Ruggiero, L.L. Alas, and U. Tatini Comparison of transesophageal and transthoracic echocardiography with contrast and color flow Doppler in the detection of patent foramen ovale Am Heart J. 128 1994 520 525
    • (1994) Am Heart J. , vol.128 , pp. 520-525
    • Belkin, R.N.1    Pollack, B.D.2    Ruggiero, M.L.3    Alas, L.L.4    Tatini, U.5
  • 30
    • 2942661375 scopus 로고    scopus 로고
    • Transthoracic echocardiography using second harmonic imaging with Valsalva manoeuvre for the detection of right to left shunts
    • N.R. Clarke, J. Timperley, A.D. Kelion, and A.P. Banning Transthoracic echocardiography using second harmonic imaging with Valsalva manoeuvre for the detection of right to left shunts Eur J Echocardiogr. 5 2004 176 181
    • (2004) Eur J Echocardiogr. , vol.5 , pp. 176-181
    • Clarke, N.R.1    Timperley, J.2    Kelion, A.D.3    Banning, A.P.4
  • 32
    • 77951095971 scopus 로고    scopus 로고
    • Head-to-head of real-time three-dimensional transthoracic echocardiography with transthoracic and transesophageal two-dimensional contrast echocardiography for the detection of patent foramen ovale
    • I. Monte, S. Grasso, S. Licciardi, and L.P. Badano Head-to-head of real-time three-dimensional transthoracic echocardiography with transthoracic and transesophageal two-dimensional contrast echocardiography for the detection of patent foramen ovale Eur J Echocardiogr. 11 2010 245 249
    • (2010) Eur J Echocardiogr. , vol.11 , pp. 245-249
    • Monte, I.1    Grasso, S.2    Licciardi, S.3    Badano, L.P.4
  • 33
    • 74949096518 scopus 로고    scopus 로고
    • Transthoracic second harmonic two-and three-dimensional echocardiography for detection of patent foramen ovale
    • S. Maff, P. Dellavesa, F. Zenone, A.M. Paino, P. Paffoni, and A. Perucca Transthoracic second harmonic two-and three-dimensional echocardiography for detection of patent foramen ovale Eur J Echocardiogr. 11 2010 57 63
    • (2010) Eur J Echocardiogr. , vol.11 , pp. 57-63
    • Maff, S.1    Dellavesa, P.2    Zenone, F.3    Paino, A.M.4    Paffoni, P.5    Perucca, A.6
  • 34
    • 0034921864 scopus 로고    scopus 로고
    • Haemodynamic quantification of different provocation manoeuvres by simultaneous measurement of right and left atrial pressure: Implications for the echocardiographic detection of persistent foramen ovale
    • S. Pfleger, K. Haase, S. Stark, A. Latsch, B. Simonis, and A. Scherhag Haemodynamic quantification of different provocation manoeuvres by simultaneous measurement of right and left atrial pressure: implications for the echocardiographic detection of persistent foramen ovale Eur J Echocardiogr. 2 2001 88 93
    • (2001) Eur J Echocardiogr. , vol.2 , pp. 88-93
    • Pfleger, S.1    Haase, K.2    Stark, S.3    Latsch, A.4    Simonis, B.5    Scherhag, A.6
  • 35
    • 0031919334 scopus 로고    scopus 로고
    • Synergistic sedation with propofol and midazolam in intensive care patients after coronary artery bypass grafting
    • G. Carrasco, L. Cabré, G. Sobrepera, J. Costa, R. Molina, and A. Cruspinera Synergistic sedation with propofol and midazolam in intensive care patients after coronary artery bypass grafting Crit Care Med. 26 1998 844 851
    • (1998) Crit Care Med. , vol.26 , pp. 844-851
    • Carrasco, G.1    Cabré, L.2    Sobrepera, G.3    Costa, J.4    Molina, R.5    Cruspinera, A.6
  • 36
    • 0021117743 scopus 로고
    • Hemodynamic effects of 2 different doses of midazolam in combination with fentanyl for induction of anesthesia in surgery of the abdominal aorta
    • C. Pomane, M. Paullin, C. Fernández, E. Vignon, and G. Francois Hemodynamic effects of 2 different doses of midazolam in combination with fentanyl for induction of anesthesia in surgery of the abdominal aorta Ann Fr Anesth Reanim. 3 1984 168 170
    • (1984) Ann Fr Anesth Reanim. , vol.3 , pp. 168-170
    • Pomane, C.1    Paullin, M.2    Fernández, C.3    Vignon, E.4    Francois, G.5
  • 37
    • 0029002304 scopus 로고
    • Atrial septal aneurysm in adult patients. A multicenter study using transthoracic and transesophageal echocardiography
    • A. Mügge, W.G. Daniel, C. Angermann, C. Spes, B.K. Khandheria, and I. Kronzon Atrial septal aneurysm in adult patients. A multicenter study using transthoracic and transesophageal echocardiography Circulation. 91 1995 2785 2792
    • (1995) Circulation. , vol.91 , pp. 2785-2792
    • Mügge, A.1    Daniel, W.G.2    Angermann, C.3    Spes, C.4    Khandheria, B.K.5    Kronzon, I.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.