메뉴 건너뛰기




Volumn 94, Issue 7, 1999, Pages 367-370

Transesophageal echocardiography and contrast-transcranial doppler sonography yield a higher rate for the detection of patent foramen ovale than one method alone;Transosophageale echokardiographie und transkranielle dopplersonographie mit ultraschallkontrastmittel sind 'erganzende, nicht konkurrierende methoden'

Author keywords

Contrast transcranial doppler sonography; Paradoxic embolism; Patent foramen ovale; Transesophageal echocardiography

Indexed keywords

ADOLESCENT; ADULT; ARTICLE; BRAIN EMBOLISM; CLINICAL ARTICLE; DIAGNOSTIC ACCURACY; DIAGNOSTIC IMAGING; DOPPLER ECHOGRAPHY; FEMALE; HEART ATRIUM SEPTUM DEFECT; HUMAN; INTERMETHOD COMPARISON; MALE; PARADOXICAL EMBOLISM; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; COMPARATIVE STUDY; ECHOGRAPHY; HEART SEPTUM DEFECT; IMAGE ENHANCEMENT; MIDDLE AGED; SENSITIVITY AND SPECIFICITY; THROMBOEMBOLISM; TRANSIENT ISCHEMIC ATTACK;

EID: 0033565148     PISSN: 07235003     EISSN: None     Source Type: Journal    
DOI: 10.1007/bf03044900     Document Type: Article
Times cited : (37)

References (22)
  • 1
    • 0141576668 scopus 로고
    • Transesophageal echocardiography in the evaluation of young adults with ischemic stroke: Promises and concerns
    • Adams HP, Love BB. Transesophageal echocardiography in the evaluation of young adults with ischemic stroke: promises and concerns. Cerebrovasc Dis 1945;5:323-7.
    • (1945) Cerebrovasc Dis , vol.5 , pp. 323-327
    • Adams, H.P.1    Love, B.B.2
  • 2
    • 0001735680 scopus 로고
    • Validation of transcranial Doppler sonography in the assessment of patent foramen ovale
    • Anzola GP, Renaldini E, Magoni M, et al. Validation of transcranial Doppler sonography in the assessment of patent foramen ovale. Cerbrovasc Dis 1995;5:194-8.
    • (1995) Cerbrovasc Dis , vol.5 , pp. 194-198
    • Anzola, G.P.1    Renaldini, E.2    Magoni, M.3
  • 3
    • 0030810276 scopus 로고    scopus 로고
    • Transkatheterverschluß des persistierenden foramen ovale als möglichkeit zur vermeidung; paradoxer embolien
    • Berger F, Uhlemann F, Nürnberg JH, et al. Transkatheterverschluß des persistierenden Foramen ovale als Möglichkeit zur Vermeidung; paradoxer Embolien. Dtsch Med Wochenschr 1997;122:1371-6.
    • (1997) Dtsch Med Wochenschr , vol.122 , pp. 1371-1376
    • Berger, F.1    Uhlemann, F.2    Nürnberg, J.H.3
  • 4
    • 0031037994 scopus 로고    scopus 로고
    • Prevention of stroke recurrence with presumed paradoxical embolism
    • Bogousslavsky J, Devuyst G, Nendaz M, et al. Prevention of stroke recurrence with presumed paradoxical embolism. J Neurol 1997;244:71-5.
    • (1997) J Neurol , vol.244 , pp. 71-75
    • Bogousslavsky, J.1    Devuyst, G.2    Nendaz, M.3
  • 5
    • 0029785440 scopus 로고    scopus 로고
    • High-intensity transient signals in patients with zerebral ischemia
    • Daffertshofer M, Ries S, Schminke U, et al. High-intensity transient signals in patients with zerebral ischemia. Stroke 1996;27:1844-9.
    • (1996) Stroke , vol.27 , pp. 1844-1849
    • Daffertshofer, M.1    Ries, S.2    Schminke, U.3
  • 6
    • 10344234699 scopus 로고    scopus 로고
    • Prognosis after stroke followed by surgical closure of patent foramen ovale: A prospective follow-up study with brain MRI and simultaneous transesophageal and transcranial Doppler ultrasound
    • Devuyst G, Bougousslavsky J, Ruchat P, et al. Prognosis after stroke followed by surgical closure of patent foramen ovale: a prospective follow-up study with brain MRI and simultaneous transesophageal and transcranial Doppler ultrasound. Neurology (NY) 1996;47:1162-6.
    • (1996) Neurology (NY) , vol.47 , pp. 1162-1166
    • Devuyst, G.1    Bougousslavsky, J.2    Ruchat, P.3
  • 7
    • 0030788936 scopus 로고    scopus 로고
    • Complementarity of contrast transcranial Doppler and contrast transesophageal echocardiogiaphy for the detection of patent foramen ovale in stroke patients
    • Devuyst G, Despland PA, Bogousslavsky J, et al. Complementarity of contrast transcranial Doppler and contrast transesophageal echocardiogiaphy for the detection of patent foramen ovale in stroke patients. Eur Neurol 1997;38:21-5.
    • (1997) Eur Neurol , vol.38 , pp. 21-25
    • Devuyst, G.1    Despland, P.A.2    Bogousslavsky, J.3
  • 8
    • 0026639871 scopus 로고
    • Patent foramen ovale as a risk factor for cryptogenic stroke
    • Di Tullio M, Sacco RL, Gopal A, et al. Patent foramen ovale as a risk factor for cryptogenic stroke. Ann Intern Med 1992;117:461-5.
    • (1992) Ann Intern Med , vol.117 , pp. 461-465
    • Di Tullio, M.1    Sacco, R.L.2    Gopal, A.3
  • 9
    • 0027324975 scopus 로고
    • Comparison of diagnostic techniques for the detection of a patent foramen ovale in stroke patients
    • Di Tullio M, Sacco RL, Venketasubramanian N, et al. Comparison of diagnostic techniques for the detection of a patent foramen ovale in stroke patients. Stroke 1993;24:1020-4.
    • (1993) Stroke , vol.24 , pp. 1020-1024
    • Di Tullio, M.1    Sacco, R.L.2    Venketasubramanian, N.3
  • 10
    • 0021352808 scopus 로고
    • Incidence and size of patent foramen ovale during the first 10 decades of life: An autopsy study of 965 normal hearts
    • Hagen P, Scholz DG, Edwards W. Incidence and size of patent foramen ovale during the first 10 decades of life: an autopsy study of 965 normal hearts. Mayo Clin Proc 1984;59:17-20.
    • (1984) Mayo Clin Proc , vol.59 , pp. 17-20
    • Hagen, P.1    Scholz, D.G.2    Edwards, W.3
  • 11
    • 0026733037 scopus 로고
    • Diagnosis of patent foramen ovale by transesophageal echocardiography and association with cerebral and peripheral embolic events
    • Hausmann D, Mügge A, Becht I, et al. Diagnosis of patent foramen ovale by transesophageal echocardiography and association with cerebral and peripheral embolic events. Am J Cardiol 1992;70:668-72.
    • (1992) Am J Cardiol , vol.70 , pp. 668-672
    • Hausmann, D.1    Mügge, A.2    Becht, I.3
  • 12
    • 0032442649 scopus 로고    scopus 로고
    • Aktueller stand der diagnostik des offenen foramen ovale
    • Heckmann JH, Hilz MJ, Brandt-Pohlmann M, et al. Aktueller Stand der Diagnostik des offenen Foramen ovale. Nervenheilkunde 1998;17:458-60.
    • (1998) Nervenheilkunde , vol.17 , pp. 458-460
    • Heckmann, J.H.1    Hilz, M.J.2    Brandt-Pohlmann, M.3
  • 13
    • 0031441294 scopus 로고    scopus 로고
    • Surgical closure of patent foramen ovale in cryptogenic stroke patients
    • Homma S, Di Tullio MR, Sacco RL, et al. Surgical closure of patent foramen ovale in cryptogenic stroke patients. Stroke 1997;28:2376-81.
    • (1997) Stroke , vol.28 , pp. 2376-2381
    • Homma, S.1    Di Tullio, M.R.2    Sacco, R.L.3
  • 14
    • 0027932157 scopus 로고
    • Comparison of transcranail contrast Doppler sonography and transesophageal contrast echocardiography for the detection of patent foramen ovale in young stroke patients
    • Job FP, Ringelstein EB, Grafen U, et al. Comparison of transcranail contrast Doppler sonography and transesophageal contrast echocardiography for the detection of patent foramen ovale in young stroke patients. Am J Cardiol 1994;74:381-4.
    • (1994) Am J Cardiol , vol.74 , pp. 381-384
    • Job, F.P.1    Ringelstein, E.B.2    Grafen, U.3
  • 15
    • 0031944285 scopus 로고    scopus 로고
    • Dye dilution and oximetry for detection of patent foramen ovale
    • Kartunnen V, Ventilä M, Hillbom M, et al. Dye dilution and oximetry for detection of patent foramen ovale. Acta Neurol Scand 1998;97:231-6.
    • (1998) Acta Neurol Scand , vol.97 , pp. 231-236
    • Kartunnen, V.1    Ventilä, M.2    Hillbom, M.3
  • 16
    • 0028059955 scopus 로고
    • Transesophageal echocardiography and contrast-TCD in the detection of patent foramen ovale: Experience with 111 patients
    • Klötzsch C, Janssen G, Berlit P. Transesophageal echocardiography and contrast-TCD in the detection of patent foramen ovale: experience with 111 patients. Neurology (NY) 1994;44:1603-6.
    • (1994) Neurology (NY) , vol.44 , pp. 1603-1606
    • Klötzsch, C.1    Janssen, G.2    Berlit, P.3
  • 17
    • 0023895824 scopus 로고    scopus 로고
    • Prevalence of patent foramen ovale in patients with stroke
    • Lechat P, Mas JL, Lascault G, et al. Prevalence of patent foramen ovale in patients with stroke. N Engl J Med 1998;318:1148-52.
    • (1998) N Engl J Med , vol.318 , pp. 1148-1152
    • Lechat, P.1    Mas, J.L.2    Lascault, G.3
  • 18
    • 0030997868 scopus 로고    scopus 로고
    • How to prevent stroke recurrence in patients with patent foramen ovale: Anticoagulants, antiaggregants, foramen closure, or nothing?
    • Nendaz M, Sarasin FP, Bogousslavsky J. How to prevent stroke recurrence in patients with patent foramen ovale: anticoagulants, antiaggregants, foramen closure, or nothing? Eur Neurol 1997;37:199-204.
    • (1997) Eur Neurol , vol.37 , pp. 199-204
    • Nendaz, M.1    Sarasin, F.P.2    Bogousslavsky, J.3
  • 19
    • 0026071709 scopus 로고
    • Superiority of transesophageal echocardiography in detecting cardiac source of embolism in patients with cerebral ischemia of uncertain etiology
    • Pearson AC, Labovitz AJ, Tatineni S, et al. Superiority of transesophageal echocardiography in detecting cardiac source of embolism in patients with cerebral ischemia of uncertain etiology. J Am Coll Cardiol 1991;1:66-72.
    • (1991) J Am Coll Cardiol , vol.1 , pp. 66-72
    • Pearson, A.C.1    Labovitz, A.J.2    Tatineni, S.3
  • 20
    • 0030966603 scopus 로고    scopus 로고
    • Treatment of patent foramen ovale and stroke: To close or not to close, that is not yet the question
    • Sacco RL, Di Tullio M, Homma S. Treatment of patent foramen ovale and stroke: to close or not to close, that is not yet the question. Eur Neurol 1997;37:205-6.
    • (1997) Eur Neurol , vol.37 , pp. 205-206
    • Sacco, R.L.1    Di Tullio, M.2    Homma, S.3
  • 21
    • 0000182992 scopus 로고
    • Patent foramen ovale: A potential source of cerebral embolism?
    • Schminke U, Ries S, Daffertshofer M, et al. Patent foramen ovale: a potential source of cerebral embolism? Cerebrovasc Dis 1995;5:133-8.
    • (1995) Cerebrovasc Dis , vol.5 , pp. 133-138
    • Schminke, U.1    Ries, S.2    Daffertshofer, M.3
  • 22
    • 0028845695 scopus 로고
    • Bedeutung sogenannter "High-Intensity Transient Signals" (HITS) während der transkraniellen dopplersonographie
    • Sliwka U, Diehl RR, Noth J. Bedeutung sogenannter "High-Intensity Transient Signals" (HITS) während der transkraniellen Dopplersonographie. Dtsch Med Wochenschr 1995;120:1667-70.
    • (1995) Dtsch Med Wochenschr , vol.120 , pp. 1667-1670
    • Sliwka, U.1    Diehl, R.R.2    Noth, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.