메뉴 건너뛰기




Volumn 29, Issue 2, 2014, Pages 127-133

Moderate patient-prosthesis mismatch predicts cardiac events and advanced functional class in young and middle-aged patients undergoing surgery due to severe aortic stenosis

Author keywords

[No Author keywords available]

Indexed keywords

ACUTE HEART INFARCTION; ADULT; AGED; ANGINA PECTORIS; AORTA PROSTHESIS; AORTA STENOSIS; AORTA VALVE REPLACEMENT; ARTICLE; ARTIFICIAL HEART PACEMAKER; CARDIOVASCULAR MORTALITY; CEREBROVASCULAR ACCIDENT; CONTROLLED STUDY; COUNTERPULSATION; EVENT FREE SURVIVAL; EXTUBATION; FAINTNESS; FEMALE; HEART ATRIUM FIBRILLATION; HEART DEATH; HEART DISEASE; HEART FAILURE; HEART FUNCTION; HEART SURGERY; HOSPITAL READMISSION; HUMAN; MAJOR CLINICAL STUDY; MALE; MIDDLE AGED; NEW YORK HEART ASSOCIATION CLASS; PATIENT PROSTHESIS MISMATCH; PNEUMONIA; POSTOPERATIVE COMPLICATION; POSTOPERATIVE HEMORRHAGE; PROPENSITY SCORE; QUALITY OF LIFE; REOPERATION; SUDDEN DEATH; SURGICAL TECHNIQUE;

EID: 84895516950     PISSN: 08860440     EISSN: 15408191     Source Type: Journal    
DOI: 10.1111/jocs.12265     Document Type: Article
Times cited : (15)

References (24)
  • 1
    • 0018104133 scopus 로고
    • The problem of valve prosthesis-patient mismatch
    • Rahimtoola SH:, The problem of valve prosthesis-patient mismatch. Circulation 1978; 58: 20-24.
    • (1978) Circulation , vol.58 , pp. 20-24
    • Rahimtoola, S.1
  • 2
    • 57949105389 scopus 로고    scopus 로고
    • Impact of prosthesis-patient mismatch on long-term survival after aortic valve replacement: Influence of age, obesity and left ventricular dysfunction
    • Mohty D, Dumesnil JG, Echahidi N, et al. Impact of prosthesis-patient mismatch on long-term survival after aortic valve replacement: Influence of age, obesity and left ventricular dysfunction. J Am Coll Cardiol 2009; 53: 39-47.
    • (2009) J Am Coll Cardiol , vol.53 , pp. 39-47
    • Mohty, D.1    Dumesnil, J.G.2    Echahidi, N.3
  • 3
    • 34247842851 scopus 로고    scopus 로고
    • Prevention of valve prosthesis-patient mismatch before aortic valve replacement: Does it matter and is it feasible
    • Pibarot P, Dumesnil JG:, Prevention of valve prosthesis-patient mismatch before aortic valve replacement: Does it matter and is it feasible ? Heart 2007; 93: 549-551.
    • (2007) Heart , vol.93 , pp. 549-551
    • Pibarot, P.1    Dumesnil, J.2
  • 4
    • 33746393625 scopus 로고    scopus 로고
    • Prosthesis-patient mismatch: Definition, clinical impact, and prevention
    • Pibarot P, Dumesnil JG:, Prosthesis-patient mismatch: Definition, clinical impact, and prevention. Heart 2006; 92: 1022-1029.
    • (2006) Heart , vol.92 , pp. 1022-1029
    • Pibarot, P.1    Dumesnil, J.2
  • 5
    • 77951264043 scopus 로고    scopus 로고
    • Prevention of moderate prosthesis-patient mismatch: Individualization vs generalization
    • Dumesnil JG, Pibarot P:, Prevention of moderate prosthesis-patient mismatch: Individualization vs generalization. Rev Esp Cardiol 2010; 63: 387-389.
    • (2010) Rev Esp Cardiol , vol.63 , pp. 387-389
    • Dumesnil, J.G.1    Pibarot, P.2
  • 6
    • 31044436430 scopus 로고    scopus 로고
    • Prosthesis-patient mismatch after aortic valve replacement: Impact on age and body size on late survival
    • Moon MR, Pasque MK, Munfakh NA, et al. Prosthesis-patient mismatch after aortic valve replacement: Impact on age and body size on late survival. Ann Thorac Surg 2006; 81: 481-489.
    • (2006) Ann Thorac Surg , vol.81 , pp. 481-489
    • Moon, M.R.1    Pasque, M.K.2    Munfakh, N.A.3
  • 7
    • 0036900518 scopus 로고    scopus 로고
    • Hemodynamics and early clinical performance of the St. Jude Medical Regent mechanical aortic valve
    • Bach DS, Sakwa MP, Goldbach M, et al. Hemodynamics and early clinical performance of the St. Jude Medical Regent mechanical aortic valve. Ann Thorac Surg 2002; 74: 2003-2009.
    • (2002) Ann Thorac Surg , vol.74 , pp. 2003-2009
    • Bach, D.S.1    Sakwa, M.P.2    Goldbach, M.3
  • 8
    • 0027499532 scopus 로고
    • Echocardiographic description of the CarboMedics bileaflet prosthetic heart valve
    • Chambers J, Cross J, Deverall P, et al. Echocardiographic description of the CarboMedics bileaflet prosthetic heart valve. J Am Coll Cardiol 1993; 21: 398-405.
    • (1993) J Am Coll Cardiol , vol.21 , pp. 398-405
    • Chambers, J.1    Cross, J.2    Deverall, P.3
  • 9
    • 24644520436 scopus 로고    scopus 로고
    • A randomized comparison of the MCRI On-X and CarboMedics Top Hat bileaflet mechanical replacement aortic valves: Early postoperative hemodynamic function and clinical events
    • Chambers J, Roxburgh J, Blauth C, et al. A randomized comparison of the MCRI On-X and CarboMedics Top Hat bileaflet mechanical replacement aortic valves: Early postoperative hemodynamic function and clinical events. J Thorac Cardiovasc Surg 2005; 130: 759-764.
    • (2005) J Thorac Cardiovasc Surg , vol.130 , pp. 759-764
    • Chambers, J.1    Roxburgh, J.2    Blauth, C.3
  • 10
    • 0031692713 scopus 로고    scopus 로고
    • Early postoperative echocardiographic hemodynamic performance of the On-X prosthetic heart valve: A multicenter study
    • Chambers J, Ely JL:, Early postoperative echocardiographic hemodynamic performance of the On-X prosthetic heart valve: A multicenter study. J Heart Valve Dis 1998; 7: 569-573.
    • (1998) J Heart Valve Dis , vol.7 , pp. 569-573
    • Chambers, J.1    Ely, J.2
  • 11
    • 33644858444 scopus 로고    scopus 로고
    • Impact of patient-prosthesis mismatch on cardiac events and midterm mortality after aortic valve replacement in patients with pure aortic stenosis
    • Tasca G, Mhagna Z, Perotti S, et al. Impact of patient-prosthesis mismatch on cardiac events and midterm mortality after aortic valve replacement in patients with pure aortic stenosis. Circulation 2006; 113: 570-576.
    • (2006) Circulation , vol.113 , pp. 570-576
    • Tasca, G.1    Mhagna, Z.2    Perotti, S.3
  • 12
    • 0033778112 scopus 로고    scopus 로고
    • An echocardiographic description of the Sulzer Carbomedics Synergy ST (Labcor) porcine valve in the aortic position
    • Chambers J, Dolman W, Jawetz J, et al. An echocardiographic description of the Sulzer Carbomedics Synergy ST (Labcor) porcine valve in the aortic position. J Heart Valve Dis 2000; 9: 661-666.
    • (2000) J Heart Valve Dis , vol.9 , pp. 661-666
    • Chambers, J.1    Dolman, W.2    Jawetz, J.3
  • 13
    • 0035004531 scopus 로고    scopus 로고
    • Patient-prosthesis mismatch can be predicted at the time of operation
    • Pibarot P, Dumesnil JG, Cartier PC, et al. Patient-prosthesis mismatch can be predicted at the time of operation. Ann Thorac Surg 2001; 71: S265-S268.
    • (2001) Ann Thorac Surg , vol.71
    • Pibarot, P.1    Dumesnil, J.G.2    Cartier, P.C.3
  • 14
    • 0033819953 scopus 로고    scopus 로고
    • Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention
    • Pibarot P, Dumesnil JG:, Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention. J Am Coll Cardiol 2000; 36: 1131-1141.
    • (2000) J Am Coll Cardiol , vol.36 , pp. 1131-1141
    • Pibarot, P.1    Dumesnil, J.2
  • 15
    • 0034619384 scopus 로고    scopus 로고
    • Prosthesis-patient mismatch affects survival after aortic valve replacement
    • Rao V, Jamieson WR, Ivanov J, et al. Prosthesis-patient mismatch affects survival after aortic valve replacement. Circulation 2000; 102: 5-9.
    • (2000) Circulation , vol.102 , pp. 5-9
    • Rao, V.1    Jamieson, W.R.2    Ivanov, J.3
  • 16
    • 34948905374 scopus 로고    scopus 로고
    • The influence of patient-prosthesis mismatch on in-hospital complications and early mortality after aortic valve replacement
    • Nozohoor S, Nilsson J, Lührs C, et al. The influence of patient-prosthesis mismatch on in-hospital complications and early mortality after aortic valve replacement. J Heart Valve Dis 2007; 16: 475-482.
    • (2007) J Heart Valve Dis , vol.16 , pp. 475-482
    • Nozohoor, S.1    Nilsson, J.2    Lührs, C.3
  • 17
    • 76549135679 scopus 로고    scopus 로고
    • Patient-prosthesis mismatch in patients with aortic stenosis undergoing isolated aortic valve replacement does not affect survival
    • Howell NJ, Keogh BE, Ray D, et al. Patient-prosthesis mismatch in patients with aortic stenosis undergoing isolated aortic valve replacement does not affect survival. Ann Thorac Surg 2010; 89: 60-64.
    • (2010) Ann Thorac Surg , vol.89 , pp. 60-64
    • Howell, N.J.1    Keogh, B.E.2    Ray, D.3
  • 18
    • 80051548519 scopus 로고    scopus 로고
    • Influence of patient-prosthesis mismatch in the octogenarian undergoing surgery for aortic valve replacement due to severe stenosis
    • Hernandez-Vaquero D, Calvo D, Garcia JM, et al. Influence of patient-prosthesis mismatch in the octogenarian undergoing surgery for aortic valve replacement due to severe stenosis. Rev Esp Cardiol 2011; 64: 774-779.
    • (2011) Rev Esp Cardiol , vol.64 , pp. 774-779
    • Hernandez-Vaquero, D.1    Calvo, D.2    Garcia, J.M.3
  • 19
    • 56049114889 scopus 로고    scopus 로고
    • Prosthesis-patient mismatch in the elderly: Survival, ventricular mass regression, and quality of life
    • Vicchio M, Della Corte A, De Santo LS, et al. Prosthesis-patient mismatch in the elderly: Survival, ventricular mass regression, and quality of life. Ann Thorac Surg 2008; 86: 1791-1797.
    • (2008) Ann Thorac Surg , vol.86 , pp. 1791-1797
    • Vicchio, M.1    Della Corte, A.2    De Santo, L.S.3
  • 20
    • 46749127787 scopus 로고    scopus 로고
    • Patient-prosthesis mismatch after aortic valve replacement in the elderly
    • Ryomoto M, Mitsuno M, Yamamura M, et al. Patient-prosthesis mismatch after aortic valve replacement in the elderly. Gen Thorac Cardiovasc Surg 2008; 56: 330-334.
    • (2008) Gen Thorac Cardiovasc Surg , vol.56 , pp. 330-334
    • Ryomoto, M.1    Mitsuno, M.2    Yamamura, M.3
  • 21
    • 42549118097 scopus 로고    scopus 로고
    • Impact of patient-prosthesis mismatch on exercise capacity in patients after bioprosthetic valve replacement
    • Bleiziffer S, Eichinger WB, Hettich I, et al. Impact of patient-prosthesis mismatch on exercise capacity in patients after bioprosthetic valve replacement. Heart 2008; 94: 637-641.
    • (2008) Heart , vol.94 , pp. 637-641
    • Bleiziffer, S.1    Eichinger, W.B.2    Hettich, I.3
  • 22
    • 0032862269 scopus 로고    scopus 로고
    • Cardiopulmonary exercise testing in patients with 21 mm St. Jude Medical aortic prosthesis
    • De Carlo M, Milano A, Musumeci G, et al. Cardiopulmonary exercise testing in patients with 21 mm St. Jude Medical aortic prosthesis. J Heart Valve Dis 1999; 8: 522-528.
    • (1999) J Heart Valve Dis , vol.8 , pp. 522-528
    • De Carlo, M.1    Milano, A.2    Musumeci, G.3
  • 23
    • 34247847791 scopus 로고    scopus 로고
    • Prediction of valve prosthesis-patient mismatch prior to aortic valve replacement: Which is the best method
    • et al: ?.
    • Bleiziffer S, Eichinger WB, Hettich I, et al. Prediction of valve prosthesis-patient mismatch prior to aortic valve replacement: Which is the best method ? Heart 2007; 93: 615-620.
    • (2007) Heart , vol.93 , pp. 615-620
    • Bleiziffer, S.1    Eichinger, W.B.2    Hettich, I.3
  • 24
    • 84866413576 scopus 로고    scopus 로고
    • Valve prosthesis-patient mismatch. 1978 to 2011: From original concept to compelling evidence
    • Pibarot P, Dumesnil JG:, Valve prosthesis-patient mismatch. 1978 to 2011: From original concept to compelling evidence. J Am Coll Cardiol 2012; 60: 1136-1139.
    • (2012) J Am Coll Cardiol , vol.60 , pp. 1136-1139
    • Pibarot, P.1    Dumesnil, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.