메뉴 건너뛰기




Volumn 63, Issue 3, 2014, Pages 479-490

Citrate versus heparin lock for hemodialysis catheters: A systematic review and meta-analysis of randomized controlled trials

Author keywords

antimicrobial solution; catheter lock; catheter related bacteremia; citrate; exit site infection; Hemodialysis; heparin; lock solution; renal replacement therapy; vascular access

Indexed keywords

ANTIMICROBIAL SOLUTION; CATHETER LOCK; CATHETER-RELATED BACTEREMIA; CITRATE; EXIT-SITE INFECTION; HEMODIALYSIS; HEPARIN; LOCK SOLUTION; RENAL REPLACEMENT THERAPY; VASCULAR ACCESS;

EID: 84894457558     PISSN: 02726386     EISSN: 15236838     Source Type: Journal    
DOI: 10.1053/j.ajkd.2013.08.016     Document Type: Article
Times cited : (97)

References (26)
  • 1
    • 0033042819 scopus 로고    scopus 로고
    • The hemodialysis catheter conundrum: Hate living with them, but can't live without them
    • S.J. Schwab, and G. Beathard The hemodialysis catheter conundrum: hate living with them, but can't live without them Kidney Int 56 1 1999 1 17
    • (1999) Kidney Int , vol.56 , Issue.1 , pp. 1-17
    • Schwab, S.J.1    Beathard, G.2
  • 2
    • 67349147029 scopus 로고    scopus 로고
    • Sodium citrate versus heparin catheter locks for cuffed central venous catheters: A single-center randomized controlled trial
    • A. Power, N. Duncan, and S.K. Singh et al. Sodium citrate versus heparin catheter locks for cuffed central venous catheters: A single-center randomized controlled trial Am J Kidney Dis 53 6 2009 1034 1041
    • (2009) Am J Kidney Dis , vol.53 , Issue.6 , pp. 1034-1041
    • Power, A.1    Duncan, N.2    Singh, S.K.3
  • 3
    • 83655201202 scopus 로고    scopus 로고
    • A randomized trial comparing gentamicin/citrate and heparin locks for central venous catheters in maintenance hemodialysis patients
    • J. Moran, S. Sun, and I. Khababa et al. A randomized trial comparing gentamicin/citrate and heparin locks for central venous catheters in maintenance hemodialysis patients Am J Kidney Dis 59 1 2012 102 107
    • (2012) Am J Kidney Dis , vol.59 , Issue.1 , pp. 102-107
    • Moran, J.1    Sun, S.2    Khababa, I.3
  • 4
  • 5
    • 42549150104 scopus 로고    scopus 로고
    • Citrate 4% Versus Heparin and the Reduction of Thrombosis Study (CHARTS)
    • J.M. MacRae, I. Dojcinovic, and O. Djurdjev et al. Citrate 4% Versus Heparin and the Reduction of Thrombosis Study (CHARTS) Clin J Am Soc Nephrol 3 2 2008 369 374
    • (2008) Clin J Am Soc Nephrol , vol.3 , Issue.2 , pp. 369-374
    • Macrae, J.M.1    Dojcinovic, I.2    Djurdjev, O.3
  • 6
    • 30944443546 scopus 로고    scopus 로고
    • Randomized, clinical trial comparison of trisodium citrate 30% and heparin as catheter-locking solution in hemodialysis patients
    • M.C. Weijmer, M.A. van den Dorpel, and P.J. Van de Ven et al. Randomized, clinical trial comparison of trisodium citrate 30% and heparin as catheter-locking solution in hemodialysis patients J Am Soc Nephrol 16 9 2005 2769 2777
    • (2005) J Am Soc Nephrol , vol.16 , Issue.9 , pp. 2769-2777
    • Weijmer, M.C.1    Van Den Dorpel, M.A.2    Van De Ven, P.J.3
  • 7
    • 0031730215 scopus 로고    scopus 로고
    • Filling hemodialysis catheters in the interdialytic period: Heparin versus citrate versus polygeline: A prospective randomized study
    • J. Buturovic, R. Ponikvar, and A. Kandus et al. Filling hemodialysis catheters in the interdialytic period: heparin versus citrate versus polygeline: A prospective randomized study Artif Organs 22 11 1998 945 947
    • (1998) Artif Organs , vol.22 , Issue.11 , pp. 945-947
    • Buturovic, J.1    Ponikvar, R.2    Kandus, A.3
  • 8
    • 0035017218 scopus 로고    scopus 로고
    • A comparative prospective study on the use of low concentrate citrate lock versus heparin lock in permanent dialysis catheters
    • L. Hendrickx, D. Kuypers, and P. Evenepoel et al. A comparative prospective study on the use of low concentrate citrate lock versus heparin lock in permanent dialysis catheters Int J Artif Organs 24 4 2001 208 211
    • (2001) Int J Artif Organs , vol.24 , Issue.4 , pp. 208-211
    • Hendrickx, L.1    Kuypers, D.2    Evenepoel, P.3
  • 9
    • 0036063589 scopus 로고    scopus 로고
    • Prevention of tunneled hemodialysis catheter-related infections using catheter-restricted filling with gentamicin and citrate: A randomized controlled study
    • G.K. Dogra, H. Herson, and B. Hutchison et al. Prevention of tunneled hemodialysis catheter-related infections using catheter-restricted filling with gentamicin and citrate: A randomized controlled study J Am Soc Nephrol 13 8 2002 2133 2139
    • (2002) J Am Soc Nephrol , vol.13 , Issue.8 , pp. 2133-2139
    • Dogra, G.K.1    Herson, H.2    Hutchison, B.3
  • 10
    • 0036660776 scopus 로고    scopus 로고
    • Antibiotic lock technique for prevention of cuffed tunnel catheter associated bacteremia
    • A. Pervez, M. Ahmed, and S. Ram et al. Antibiotic lock technique for prevention of cuffed tunnel catheter associated bacteremia J Vasc Access 3 3 2002 108 113
    • (2002) J Vasc Access , vol.3 , Issue.3 , pp. 108-113
    • Pervez, A.1    Ahmed, M.2    Ram, S.3
  • 11
    • 2942735234 scopus 로고    scopus 로고
    • Prevention of dialysis catheter-related sepsis with a citrate-taurolidine-containing lock solution
    • M.G. Betjes, and M. van Agteren Prevention of dialysis catheter-related sepsis with a citrate-taurolidine-containing lock solution Nephrol Dial Transplant 19 6 2004 1546 1551
    • (2004) Nephrol Dial Transplant , vol.19 , Issue.6 , pp. 1546-1551
    • Betjes, M.G.1    Van Agteren, M.2
  • 12
    • 33748748203 scopus 로고    scopus 로고
    • Comparison of low-dose gentamicin with minocycline as catheter lock solutions in the prevention of catheter-related bacteremia
    • U.S. Nori, A. Manoharan, J. Yee, and A. Besarab Comparison of low-dose gentamicin with minocycline as catheter lock solutions in the prevention of catheter-related bacteremia Am J Kidney Dis 48 4 2006 596 605
    • (2006) Am J Kidney Dis , vol.48 , Issue.4 , pp. 596-605
    • Nori, U.S.1    Manoharan, A.2    Yee, J.3    Besarab, A.4
  • 13
    • 77952542208 scopus 로고    scopus 로고
    • A randomized double-blind controlled trial of taurolidine-citrate catheter locks for the prevention of bacteremia in patients treated with hemodialysis
    • L.R. Solomon, J.S. Cheesbrough, and L. Ebah et al. A randomized double-blind controlled trial of taurolidine-citrate catheter locks for the prevention of bacteremia in patients treated with hemodialysis Am J Kidney Dis 55 6 2010 1060 1068
    • (2010) Am J Kidney Dis , vol.55 , Issue.6 , pp. 1060-1068
    • Solomon, L.R.1    Cheesbrough, J.S.2    Ebah, L.3
  • 14
    • 79952106935 scopus 로고    scopus 로고
    • Approaches to prolong the use of uncuffed hemodialysis catheters: Results of a randomized trial
    • V. Filiopoulos, D. Hadjiyannakos, and I. Koutis et al. Approaches to prolong the use of uncuffed hemodialysis catheters: results of a randomized trial Am J Nephrol 33 3 2011 260 268
    • (2011) Am J Nephrol , vol.33 , Issue.3 , pp. 260-268
    • Filiopoulos, V.1    Hadjiyannakos, D.2    Koutis, I.3
  • 15
    • 79953204575 scopus 로고    scopus 로고
    • A novel antimicrobial and antithrombotic lock solution for hemodialysis catheters: A multi-center, controlled, randomized trial
    • D.G. Maki, S.R. Ash, R.K. Winger, and P. Lavin A novel antimicrobial and antithrombotic lock solution for hemodialysis catheters: A multi-center, controlled, randomized trial Crit Care Med 39 4 2011 613 620
    • (2011) Crit Care Med , vol.39 , Issue.4 , pp. 613-620
    • Maki, D.G.1    Ash, S.R.2    Winger, R.K.3    Lavin, P.4
  • 16
    • 34548847483 scopus 로고    scopus 로고
    • Current management of vascular access
    • M. Allon Current management of vascular access Clin J Am Soc Nephrol 2 2007 786 800
    • (2007) Clin J Am Soc Nephrol , vol.2 , pp. 786-800
    • Allon, M.1
  • 17
    • 34547208226 scopus 로고    scopus 로고
    • Concentrated heparin lock is associated with major bleeding complications after tunneled hemodialysis catheter placement
    • A.S. Yevzlin, R.J. Sanchez, and J.G. Hiatt et al. Concentrated heparin lock is associated with major bleeding complications after tunneled hemodialysis catheter placement Semin Dial 20 4 2007 351 354
    • (2007) Semin Dial , vol.20 , Issue.4 , pp. 351-354
    • Yevzlin, A.S.1    Sanchez, R.J.2    Hiatt, J.G.3
  • 18
    • 38149018427 scopus 로고    scopus 로고
    • A meta-analysis of hemodialysis catheter locking solutions in the prevention of catheter-related infection
    • Y. Jaffer, N.M. Selby, M.W. Taal, R.J. Fluck, and C.W. McIntyre A meta-analysis of hemodialysis catheter locking solutions in the prevention of catheter-related infection Am J Kidney Dis 51 2 2008 233 241
    • (2008) Am J Kidney Dis , vol.51 , Issue.2 , pp. 233-241
    • Jaffer, Y.1    Selby, N.M.2    Taal, M.W.3    Fluck, R.J.4    McIntyre, C.W.5
  • 19
    • 44449152491 scopus 로고    scopus 로고
    • Preventing haemodialysis catheter-related bacteraemia with an antimicrobial lock solution: A meta-analysis of prospective randomized trials
    • L. Labriola, R. Crott, and M. Jadoul Preventing haemodialysis catheter-related bacteraemia with an antimicrobial lock solution: A meta-analysis of prospective randomized trials Nephrol Dial Transplant 23 5 2008 1666 1672
    • (2008) Nephrol Dial Transplant , vol.23 , Issue.5 , pp. 1666-1672
    • Labriola, L.1    Crott, R.2    Jadoul, M.3
  • 20
    • 46249086815 scopus 로고    scopus 로고
    • Antimicrobial lock solutions for the prevention of infections associated with intravascular catheters in patients undergoing hemodialysis: Systematic review and meta-analysis of randomized, controlled trials
    • D. Yahav, B. Rozen-Zvi, and A. Gafter-Gvili et al. Antimicrobial lock solutions for the prevention of infections associated with intravascular catheters in patients undergoing hemodialysis: systematic review and meta-analysis of randomized, controlled trials Clin Infect Dis 47 1 2008 83 93
    • (2008) Clin Infect Dis , vol.47 , Issue.1 , pp. 83-93
    • Yahav, D.1    Rozen-Zvi, B.2    Gafter-Gvili, A.3
  • 21
    • 77950207610 scopus 로고    scopus 로고
    • Reduction of biofilm formation with trisodium citrate in haemodialysis catheters: A randomized controlled trial
    • J.W. Bosma, C.E. Siegert, P.G. Peerbooms, and M.C. Weijmer Reduction of biofilm formation with trisodium citrate in haemodialysis catheters: A randomized controlled trial Nephrol Dial Transplant 25 4 2010 1213 1217
    • (2010) Nephrol Dial Transplant , vol.25 , Issue.4 , pp. 1213-1217
    • Bosma, J.W.1    Siegert, C.E.2    Peerbooms, P.G.3    Weijmer, M.C.4
  • 22
    • 33846657539 scopus 로고    scopus 로고
    • Sodium citrate 4% locking solution for central venous dialysis catheters - An effective, more cost-efficient alternative to heparin
    • L. Grudzinski, P. Quinan, S. Kwok, and A. Pierratos Sodium citrate 4% locking solution for central venous dialysis catheters - an effective, more cost-efficient alternative to heparin Nephrol Dial Transplant 22 2 2007 471 476
    • (2007) Nephrol Dial Transplant , vol.22 , Issue.2 , pp. 471-476
    • Grudzinski, L.1    Quinan, P.2    Kwok, S.3    Pierratos, A.4
  • 23
    • 54749107591 scopus 로고    scopus 로고
    • Locking solutions for hemodialysis catheters; Heparin and citrate - A position paper by ASDIN
    • J.E. Moran, and S.R. Ash Locking solutions for hemodialysis catheters; heparin and citrate - a position paper by ASDIN Semin Dial 21 5 2008 490 492
    • (2008) Semin Dial , vol.21 , Issue.5 , pp. 490-492
    • Moran, J.E.1    Ash, S.R.2
  • 24
    • 77952988363 scopus 로고    scopus 로고
    • Catheter-related blood stream infections (CRBSI): A European view
    • R. Vanholder, B. Canaud, and R. Fluck et al. Catheter-related blood stream infections (CRBSI): A European view Nephrol Dial Transplant 25 6 2010 1753 1756
    • (2010) Nephrol Dial Transplant , vol.25 , Issue.6 , pp. 1753-1756
    • Vanholder, R.1    Canaud, B.2    Fluck, R.3
  • 25
    • 84872360669 scopus 로고    scopus 로고
    • Sodium citrate 4% versus heparin as a lock solution in hemodialysis patients with central venous catheters
    • C.K. Yon, and C.L. Low Sodium citrate 4% versus heparin as a lock solution in hemodialysis patients with central venous catheters Am J Health Syst Pharm 70 2 2013 131 136
    • (2013) Am J Health Syst Pharm , vol.70 , Issue.2 , pp. 131-136
    • Yon, C.K.1    Low, C.L.2
  • 26
    • 78149300095 scopus 로고    scopus 로고
    • Trisodium citrate: An alternative to unfractionated heparin for hemodialysis catheter dwells
    • D.A. Pierce, and M.V. Rocco Trisodium citrate: An alternative to unfractionated heparin for hemodialysis catheter dwells Pharmacotherapy 30 11 2010 1150 1158
    • (2010) Pharmacotherapy , vol.30 , Issue.11 , pp. 1150-1158
    • Pierce, D.A.1    Rocco, M.V.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.