메뉴 건너뛰기




Volumn 56, Issue 1, 1999, Pages 1-17

The hemodialysis catheter conundrum: Hate living with them, but can't live without them

Author keywords

Arteriovenous fistula; Dialysis; Infection; Renal replacement therapy; Thrombosis; Vascular access

Indexed keywords

UROKINASE;

EID: 0033042819     PISSN: 00852538     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1523-1755.1999.00512.x     Document Type: Article
Times cited : (347)

References (10)
  • 1
    • 0030852921 scopus 로고    scopus 로고
    • The USRDS dialysis morbidity and mortality study. Wave 2
    • EXCERPTS FROM THE USRDS 1997 ANNUAL REPORT. IV. The USRDS dialysis morbidity and mortality study. Wave 2. Am J Kidney Dis 30 (Suppl 1):S67-S85, 1997
    • (1997) Am J Kidney Dis , vol.30 , Issue.1 SUPPL.
  • 2
    • 0028475361 scopus 로고
    • Acute vascular access: New advances
    • FAN PY: Acute vascular access: New advances. Adv Renal Replace Ther 1:90-98, 1994
    • (1994) Adv Renal Replace Ther , vol.1 , pp. 90-98
    • Fan, P.Y.1
  • 4
    • 0024242554 scopus 로고
    • Use of a silicon catheter with a Dacron cuff for dialysis short term access
    • MOSS AH, MCLAUGHLIN MM, LAMPERT KD, HOLLEY JI: Use of a silicon catheter with a Dacron cuff for dialysis short term access. Am J Kidney Dis 12:492-498, 1988
    • (1988) Am J Kidney Dis , vol.12 , pp. 492-498
    • Moss, A.H.1    Mclaughlin, M.M.2    Lampert, K.D.3    Holley, J.I.4
  • 5
    • 0022755673 scopus 로고
    • Minimum performance standards for double-lumen subclavian cannulas for hemodialysis
    • BREGMAN H, MILLER K, BERRY L: Minimum performance standards for double-lumen subclavian cannulas for hemodialysis. ASAIO Trans 32:500-502, 1986
    • (1986) ASAIO Trans , vol.32 , pp. 500-502
    • Bregman, H.1    Miller, K.2    Berry, L.3
  • 6
    • 0025457138 scopus 로고
    • Pressure effects on roller pump blood flow during hemodialysis
    • DEPNER TA, RIZWAN S, STASI TA: Pressure effects on roller pump blood flow during hemodialysis. ASAIO Trans 321:M456-M459, 1990
    • (1990) ASAIO Trans , vol.321
    • Depner, T.A.1    Rizwan, S.2    Stasi, T.A.3
  • 7
    • 0031951225 scopus 로고    scopus 로고
    • Adequacy of hemodialysis with cuffed central vein catheters
    • ATHIRAKUL K, SCHWAB SJ, CONLON P: Adequacy of hemodialysis with cuffed central vein catheters. Nephrol Dial Transplant 13:745-749, 1998
    • (1998) Nephrol Dial Transplant , vol.13 , pp. 745-749
    • Athirakul, K.1    Schwab, S.J.2    Conlon, P.3
  • 8
    • 0007651235 scopus 로고    scopus 로고
    • Treatment of tunneled cuffed catheter dysfunction
    • NKF-DOQI CLINICAL PRACTICE GUIDELINES FOR VASCULAR ACCESS. GUIDELINE 23: Treatment of tunneled cuffed catheter dysfunction. Am J Kidney Dis 30(Suppl 3):S175-S176, 1997
    • (1997) Am J Kidney Dis , vol.30 , Issue.3 SUPPL.
  • 9
    • 0027164327 scopus 로고
    • Factors affecting delivery of high-efficiency dialysis using temporary vascular access
    • KELBER J, DELMEZ JA, WINDUS DW: Factors affecting delivery of high-efficiency dialysis using temporary vascular access. Am J Kidney Dis 22:24-29, 1993
    • (1993) Am J Kidney Dis , vol.22 , pp. 24-29
    • Kelber, J.1    Delmez, J.A.2    Windus, D.W.3
  • 10
    • 84941817891 scopus 로고
    • Central vein catheterization: Failure and complication rates by three percutaneous approaches
    • SZNAJDER JI, ZVEIBIL FR, BITTERMAN H, WEINER P, BURSZTEIN S: Central vein catheterization: failure and complication rates by three percutaneous approaches. Arch Intern Med 146:259-261, 1986
    • (1986) Arch Intern Med , vol.146 , pp. 259-261
    • Sznajder, J.I.1    Zveibil, F.R.2    Bitterman, H.3    Weiner, P.4    Bursztein, S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.