-
1
-
-
33746393625
-
Prosthesis-patient mismatch: Definition, clinical impact, and prevention
-
DOI 10.1136/hrt.2005.067363
-
Pibarot P, Dumesnil JG (2006) Prosthesis-patient mismatch: definition, clinical impact, and prevention. Heart 92(8):1022-1029. doi: 10.1136/hrt.2005.067363 (Pubitemid 44125207)
-
(2006)
Heart
, vol.92
, Issue.8
, pp. 1022-1029
-
-
Pibarot, P.1
Dumesnil, J.G.2
-
2
-
-
0018104133
-
The problem of valve prosthesis-patient mismatch
-
Rahimtoola SH (1978) The problem of valve prosthesis-patient mismatch. Circulation 58(1):20-24 (Pubitemid 8376654)
-
(1978)
Circulation
, vol.58
, Issue.1
, pp. 20-24
-
-
Rahimtoola, S.H.1
-
3
-
-
0026438436
-
Valve prosthesis hemodynamics and the problem of high transprosthetic pressure gradients
-
1389276 10.1016/1010-7940(92)90019-T (discussion S38)
-
Dumesnil JG, Yoganathan AP (1992) Valve prosthesis hemodynamics and the problem of high transprosthetic pressure gradients. Eur J Cardiothorac Surg 6(Suppl 1):S34-S37 (discussion S38)
-
(1992)
Eur J Cardiothorac Surg
, vol.6
, Issue.SUPPL. 1
-
-
Dumesnil, J.G.1
Yoganathan, A.P.2
-
4
-
-
0025179228
-
Validation and applications of indexed aortic prosthetic valve areas calculated by Doppler echocardiography
-
Dumesnil JG, Honos GN, Lemieux M, Beauchemin J (1990) Validation and applications of indexed aortic prosthetic valve areas calculated by Doppler echocardiography. J Am Coll Cardiol 16(3):637-643 (Pubitemid 20296128)
-
(1990)
Journal of the American College of Cardiology
, vol.16
, Issue.3
, pp. 637-643
-
-
Dumesnil, J.G.1
Honos, G.N.2
Lemieux, M.3
Beauchemin, J.4
-
5
-
-
0033819953
-
Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention
-
1:STN:280:DC%2BD3cvnslSqsA%3D%3D 11028462 10.1016/S0735-1097(00)00859-7 (pii:S0735-1097(00)00859-7)
-
Pibarot P, Dumesnil JG (2000) Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention. J Am Coll Cardiol 36(4):1131-1141 (pii:S0735-1097(00)00859-7)
-
(2000)
J Am Coll Cardiol
, vol.36
, Issue.4
, pp. 1131-1141
-
-
Pibarot, P.1
Dumesnil, J.G.2
-
6
-
-
13244251182
-
Impact of valve prosthesis-patient mismatch on left ventricular mass regression following aortic valve replacement
-
DOI 10.1016/j.athoracsur.2004.04.042, PII S0003497504009695
-
Tasca G, Brunelli F, Cirillo M, DallaTomba M, Mhagna Z, Troise G, Quaini E (2005) Impact of valve prosthesis-patient mismatch on left ventricular mass regression following aortic valve replacement. Ann Thorac Surg 79(2):505-510. doi: 10.1016/j.athoracsur.2004.04.042 (Pubitemid 40186547)
-
(2005)
Annals of Thoracic Surgery
, vol.79
, Issue.2
, pp. 505-510
-
-
Tasca, G.1
Brunelli, F.2
Cirillo, M.3
Dallatomba, M.4
Mhagna, Z.5
Troise, G.6
Quaini, E.7
-
7
-
-
79951966661
-
Defining patient-prosthesis mismatch and its effect on survival in patients with impaired ejection fraction
-
10.1016/j.athoracsur.2010.11.033 21352981 10.1016/j.athoracsur.2010.11. 033
-
Cotoni DA, Palac RT, Dacey LJ, O'Rourke DJ (2011) Defining patient-prosthesis mismatch and its effect on survival in patients with impaired ejection fraction. Ann Thorac Surg 91(3):692-699. doi: 10.1016/j.athoracsur. 2010.11.033
-
(2011)
Ann Thorac Surg
, vol.91
, Issue.3
, pp. 692-699
-
-
Cotoni, D.A.1
Palac, R.T.2
Dacey, L.J.3
O'Rourke, D.J.4
-
9
-
-
0023257685
-
Aortic valve replacement with a small prosthesis
-
1:STN:280:DyaL2szgt1WksQ%3D%3D 3621535
-
Teoh KH, Fulop JC, Weisel RD, Ivanov J, Tong CP, Slattery SA, Rakowski H (1987) Aortic valve replacement with a small prosthesis. Circulation 76(3 Pt 2):III123-III131
-
(1987)
Circulation
, vol.76
, Issue.3 PART 2
-
-
Teoh, K.H.1
Fulop, J.C.2
Weisel, R.D.3
Ivanov, J.4
Tong, C.P.5
Slattery, S.A.6
Rakowski, H.7
-
10
-
-
0025175559
-
Clinical and Doppler echocardiographic evaluation of bioprosthetic valve failure after 10 years
-
1:STN:280:DyaK3M%2FivF2gtQ%3D%3D 2225395
-
Teoh KH, Ivanov J, Weisel RD, Daniel LB, Darcel IC, Rakowski H (1990) Clinical and Doppler echocardiographic evaluation of bioprosthetic valve failure after 10 years. Circulation 82(5 Suppl):IV110-IV116
-
(1990)
Circulation
, vol.82
, Issue.5 SUPPL.
-
-
Teoh, K.H.1
Ivanov, J.2
Weisel, R.D.3
Daniel, L.B.4
Darcel, I.C.5
Rakowski, H.6
-
11
-
-
0026533821
-
Value of exercise Doppler echocardiography in patients with prosthetic or bioprosthetic cardiac valves
-
1734650 10.1016/0002-9149(92)90235-Q
-
van den Brink RB, Verheul HA, Visser CA, Koelemay MJ, Dunning AJ (1992) Value of exercise Doppler echocardiography in patients with prosthetic or bioprosthetic cardiac valves. Am J Cardiol 69(4):367-372
-
(1992)
Am J Cardiol
, vol.69
, Issue.4
, pp. 367-372
-
-
Van Den Brink, R.B.1
Verheul, H.A.2
Visser, C.A.3
Koelemay, M.J.4
Dunning, A.J.5
-
12
-
-
0027425314
-
Criteria to select proper valve prosthesis for aortic valve replacement. Comparative assessment of various valve prostheses via continuous wave Doppler echocardiography
-
Shigenobu M, Sano S (1993) Criteria to select proper valve prosthesis for aortic valve replacement. Comparative assessment of various valve prostheses via continuous wave Doppler echocardiography. J Cardiovasc Surg (Torino) 34(3):203-208 (Pubitemid 23287371)
-
(1993)
Journal of Cardiovascular Surgery
, vol.34
, Issue.3
, pp. 203-208
-
-
Shigenobu, M.1
Sano, S.2
-
13
-
-
0034619384
-
Prosthesis-patient mismatch affects survival after aortic valve replacement
-
1:STN:280:DC%2BD3M%2FlvFyjtw%3D%3D 11082354
-
Rao V, Jamieson WR, Ivanov J, Armstrong S, David TE (2000) Prosthesis-patient mismatch affects survival after aortic valve replacement. Circulation 102(19 Suppl 3):III5-III9
-
(2000)
Circulation
, vol.102
, Issue.19 SUPPL. 3
-
-
Rao, V.1
Jamieson, W.R.2
Ivanov, J.3
Armstrong, S.4
David, T.E.5
-
14
-
-
0042859863
-
Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement
-
DOI 10.1161/01.CIR.0000085167.67105.32
-
Blais C, Dumesnil JG, Baillot R, Simard S, Doyle D, Pibarot P (2003) Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement. Circulation 108(8):983-988. doi: 10.1161/01.CIR.0000085167. 67105.32 (Pubitemid 37048229)
-
(2003)
Circulation
, vol.108
, Issue.8
, pp. 983-988
-
-
Blais, C.1
Dumesnil, J.G.2
Baillot, R.3
Simard, S.4
Doyle, D.5
Pibarot, P.6
-
15
-
-
33644858444
-
Impact of prosthesis-patient mismatch on cardiac events and midterm mortality after aortic valve replacement in patients with pure aortic stenosis
-
10.1161/CIRCULATIONAHA.105.587022 16401767 10.1161/CIRCULATIONAHA.105. 587022
-
Tasca G, Mhagna Z, Perotti S, Centurini PB, Sabatini T, Amaducci A, Brunelli F, Cirillo M, Dalla Tomba M, Quaini E, Troise G, Pibarot P (2006) Impact of prosthesis-patient mismatch on cardiac events and midterm mortality after aortic valve replacement in patients with pure aortic stenosis. Circulation 113(4):570-576. doi: 10.1161/CIRCULATIONAHA.105.587022
-
(2006)
Circulation
, vol.113
, Issue.4
, pp. 570-576
-
-
Tasca, G.1
Mhagna, Z.2
Perotti, S.3
Centurini, P.B.4
Sabatini, T.5
Amaducci, A.6
Brunelli, F.7
Cirillo, M.8
Dalla Tomba, M.9
Quaini, E.10
Troise, G.11
Pibarot, P.12
-
16
-
-
33745044871
-
Patient prosthesis mismatch affects short- and long-term outcomes after aortic valve replacement
-
DOI 10.1016/j.ejcts.2006.04.007, PII S1010794006004118
-
Walther T, Rastan A, Falk V, Lehmann S, Garbade J, Funkat AK, Mohr FW, Gummert JF (2006) Patient prosthesis mismatch affects short- and long-term outcomes after aortic valve replacement. Eur J Cardiothorac Surg 30(1):15-19. doi: 10.1016/j.ejcts.2006.04.007 (Pubitemid 44183638)
-
(2006)
European Journal of Cardio-thoracic Surgery
, vol.30
, Issue.1
, pp. 15-19
-
-
Walther, T.1
Rastan, A.2
Falk, V.3
Lehmann, S.4
Garbade, J.5
Funkat, A.K.6
Mohr, F.W.7
Gummert, J.F.8
-
17
-
-
0034087385
-
Aortic valve replacement: Is valve size important?
-
Medalion B, Blackstone EH, Lytle BW, White J, Arnold JH, Cosgrove DM (2000) Aortic valve replacement: is valve size important? J Thorac Cardiovasc Surg 119(5):963-974 (pii:S0022522300163834) (Pubitemid 30327416)
-
(2000)
Journal of Thoracic and Cardiovascular Surgery
, vol.119
, Issue.5
, pp. 963-974
-
-
Medalion, B.1
Blackstone, E.H.2
Lytle, B.W.3
White, J.4
Arnold, J.H.5
Cosgrove, D.M.6
-
18
-
-
0036316479
-
Influence of patient-prosthesis mismatch on long-term results after aortic valve replacement with a stented bioprosthesis
-
Frapier JM, Rouviere P, Razcka F, Aymard T, Albat B, Chaptal PA (2002) Influence of patient-prosthesis mismatch on long-term results after aortic valve replacement with a stented bioprosthesis. J Heart Valve Dis 11(4):543-551 (Pubitemid 34814522)
-
(2002)
Journal of Heart Valve Disease
, vol.11
, Issue.4
, pp. 543-551
-
-
Frapier, J.M.1
Rouviere, P.2
Razcka, F.3
Aymard, T.4
Albat, B.5
Chaptal, P.A.6
-
19
-
-
33746210044
-
Prosthesis-Patient Mismatch is Not Clinically Relevant in Aortic Valve Replacement Using the Carpentier-Edwards Perimount Valve
-
DOI 10.1016/j.athoracsur.2006.03.089, PII S0003497506006497
-
Flameng W, Meuris B, Herijgers P, Herregods MC (2006) Prosthesis-patient mismatch is not clinically relevant in aortic valve replacement using the Carpentier-Edwards Perimount valve. Ann Thorac Surg 82(2):530-536. doi: 10.1016/j.athoracsur.2006.03.089 (Pubitemid 44088650)
-
(2006)
Annals of Thoracic Surgery
, vol.82
, Issue.2
, pp. 530-536
-
-
Flameng, W.1
Meuris, B.2
Herijgers, P.3
Herregods, M.-C.4
-
20
-
-
31044436430
-
Prosthesis-patient mismatch after aortic valve replacement: Impact of age and body size on late survival
-
DOI 10.1016/j.athoracsur.2005.07.084, PII S0003497505013640
-
Moon MR, Pasque MK, Munfakh NA, Melby SJ, Lawton JS, Moazami N, Codd JE, Crabtree TD, Barner HB, Damiano RJ Jr (2006) Prosthesis-patient mismatch after aortic valve replacement: impact of age and body size on late survival. Ann Thorac Surg 81(2):481-488. doi: 10.1016/j.athoracsur.2005.07.084 (discussion 489) (Pubitemid 43120540)
-
(2006)
Annals of Thoracic Surgery
, vol.81
, Issue.2
, pp. 481-489
-
-
Moon, M.R.1
Pasque, M.K.2
Munfakh, N.A.3
Melby, S.J.4
Lawton, J.S.5
Moazami, N.6
Codd, J.E.7
Crabtree, T.D.8
Barner, H.B.9
Damiano Jr., R.J.10
-
21
-
-
35948945665
-
Low-gradient aortic stenosis: Impact of prosthesis-patient mismatch on survival
-
DOI 10.1093/eurheartj/ehm393
-
Monin JL, Monchi M, Kirsch ME, Petit-Eisenmann H, Baleynaud S, Chauvel C, Metz D, Adams C, Quere JP, Gueret P, Tribouilloy C (2007) Low-gradient aortic stenosis: impact of prosthesis-patient mismatch on survival. Eur Heart J 28(21):2620-2626. doi: 10.1093/eurheartj/ehm393 (Pubitemid 350071524)
-
(2007)
European Heart Journal
, vol.28
, Issue.21
, pp. 2620-2626
-
-
Monin, J.-L.1
Monchi, M.2
Kirsch, M.E.W.3
Petit-Eisenmann, H.4
Baleynaud, S.5
Chauvel, C.6
Metz, D.7
Adams, C.8
Quere, J.-P.9
Gueret, P.10
Tribouilloy, C.11
-
22
-
-
34948905374
-
The influence of patient-prosthesis mismatch on in-hospital complications and early mortality after aortic valve replacement
-
Nozohoor S, Nilsson J, Luhrs C, Roijer A, Sjogren J (2007) The influence of patient-prosthesis mismatch on in-hospital complications and early mortality after aortic valve replacement. J Heart Valve Dis 16(5):475-482 (Pubitemid 47527395)
-
(2007)
Journal of Heart Valve Disease
, vol.16
, Issue.5
, pp. 475-482
-
-
Nozohoor, S.1
Nilsson, J.2
Luhrs, C.3
Roijer, A.4
Sjogren, J.5
-
23
-
-
56749165459
-
Moderate patient-prosthesis mismatch after valve replacement for severe aortic stenosis has no impact on short-term and long-term mortality
-
10.1136/hrt.2008.142596 1:STN:280:DC%2BD1cjktVGmtQ%3D%3D 18450841 10.1136/hrt.2008.142596
-
Mascherbauer J, Rosenhek R, Fuchs C, Pernicka E, Klaar U, Scholten C, Heger M, Wollenek G, Maurer G, Baumgartner H (2008) Moderate patient-prosthesis mismatch after valve replacement for severe aortic stenosis has no impact on short-term and long-term mortality. Heart 94(12):1639-1645. doi: 10.1136/hrt.2008.142596
-
(2008)
Heart
, vol.94
, Issue.12
, pp. 1639-1645
-
-
Mascherbauer, J.1
Rosenhek, R.2
Fuchs, C.3
Pernicka, E.4
Klaar, U.5
Scholten, C.6
Heger, M.7
Wollenek, G.8
Maurer, G.9
Baumgartner, H.10
-
24
-
-
33744947842
-
Patient-prosthesis mismatch does not affect survival following aortic valve replacement
-
DOI 10.1016/j.ejcts.2006.03.046, PII S1010794006003587
-
Howell NJ, Keogh BE, Barnet V, Bonser RS, Graham TR, Rooney SJ, Wilson IC, Pagano D (2006) Patient-prosthesis mismatch does not affect survival following aortic valve replacement. Eur J Cardiothorac Surg 30(1):10-14. doi: 10.1016/j.ejcts.2006.03.046 (Pubitemid 43850318)
-
(2006)
European Journal of Cardio-thoracic Surgery
, vol.30
, Issue.1
, pp. 10-14
-
-
Howell, N.J.1
Keogh, B.E.2
Barnet, V.3
Bonser, R.S.4
Graham, T.R.5
Rooney, S.J.6
Wilson, I.C.7
Pagano, D.8
-
25
-
-
84858681268
-
Prognostic value of mild-to-moderate pulmonary hypertension in patients with severe aortic valve stenosis undergoing aortic valve replacement
-
10.1007/s00392-011-0367-3 21969256 10.1007/s00392-011-0367-3
-
Zuern CS, Eick C, Rizas K, Stoleriu C, Woernle B, Wildhirt S, Herdeg C, Stock U, Gawaz M, Bauer A (2012) Prognostic value of mild-to-moderate pulmonary hypertension in patients with severe aortic valve stenosis undergoing aortic valve replacement. Clin Res Cardiol 101(2):81-88. doi: 10.1007/s00392-011-0367-3
-
(2012)
Clin Res Cardiol
, vol.101
, Issue.2
, pp. 81-88
-
-
Zuern, C.S.1
Eick, C.2
Rizas, K.3
Stoleriu, C.4
Woernle, B.5
Wildhirt, S.6
Herdeg, C.7
Stock, U.8
Gawaz, M.9
Bauer, A.10
-
26
-
-
33846612705
-
Prevalence and prognostic impact of comorbidities in patients with severe aortic valve stenosis
-
DOI 10.1007/s00392-006-0452-1
-
Bruch C, Kauling D, Reinecke H, Rothenburger M, Scheld HH, Breithardt G, Wichter T (2007) Prevalence and prognostic impact of comorbidities in patients with severe aortic valve stenosis. Clin Res Cardiol 96(1):23-29. doi: 10.1007/s00392-006-0452-1 (Pubitemid 46175367)
-
(2007)
Clinical Research in Cardiology
, vol.96
, Issue.1
, pp. 23-29
-
-
Bruch, C.1
Kauling, D.2
Reinecke, H.3
Rothenburger, M.4
Scheld, H.H.5
Breithardt, G.6
Wichter, T.7
-
27
-
-
33646522248
-
Systemic mechanical heart valve replacement in children under 16 years of age
-
10.1007/s00392-006-0376-9 1:STN:280:DC%2BD2s3gslaguw%3D%3D 16680580 10.1007/s00392-006-0376-9
-
Tiete AR, Sachweh JS, Groetzner J, Gulbins H, Muehler EG, Messmer BJ, Daebritz SH (2006) Systemic mechanical heart valve replacement in children under 16 years of age. Clin Res Cardiol 95(5):281-288. doi: 10.1007/s00392-006-0376-9
-
(2006)
Clin Res Cardiol
, vol.95
, Issue.5
, pp. 281-288
-
-
Tiete, A.R.1
Sachweh, J.S.2
Groetzner, J.3
Gulbins, H.4
Muehler, E.G.5
Messmer, B.J.6
Daebritz, S.H.7
-
28
-
-
0030932398
-
Obstruction of mechanical mitral prostheses: Analysis of pathologic findings
-
DOI 10.1016/S0003-4975(96)01391-4, PII S0003497596013914
-
Vitale N, Renzulli A, Agozzino L, Pollice A, Tedesco N, de Luca Tupputi S, Chinosa L, Cotrufo M (1997) Obstruction of mechanical mitral prostheses: analysis of pathologic findings. Ann Thorac Surg 63(4):1101-1106 (pii:S0003497596013914) (Pubitemid 27191669)
-
(1997)
Annals of Thoracic Surgery
, vol.63
, Issue.4
, pp. 1101-1106
-
-
Vitale, N.1
Renzulli, A.2
Agozzino, L.3
Pollice, A.4
Tedesco, N.5
De Luca Tupputi Schinosa, L.6
Cotrufo, M.7
-
29
-
-
0036149895
-
Mitral stenosis after mitral valve repair for non-rheumatic mitral regurgitation
-
DOI 10.1016/S0003-4975(01)03305-7, PII S0003497501033057
-
Ibrahim MF, David TE (2002) Mitral stenosis after mitral valve repair for non-rheumatic mitral regurgitation. Ann Thorac Surg 73(1):34-36 (Pubitemid 34084530)
-
(2002)
Annals of Thoracic Surgery
, vol.73
, Issue.1
, pp. 34-36
-
-
Ibrahim, M.F.1
David, T.E.2
-
30
-
-
84878563265
-
Early SAPIEN transcatheter heart valve dysfunction due to tissue ingrowth in an octogenarian
-
10.1007/s00392-012-0518-1 1:STN:280:DC%2BC3s%2FotVahsg%3D%3D 23097135 10.1007/s00392-012-0518-1
-
Blumenstein J, Van Linden A, Kim WK, Skwara W, Schoenburg M, Arsalan M, Moellmann H, Niederhagen M, Kempfert J, Walther T (2013) Early SAPIEN transcatheter heart valve dysfunction due to tissue ingrowth in an octogenarian. Clin Res Cardiol 102(3):237-240. doi: 10.1007/s00392-012-0518-1
-
(2013)
Clin Res Cardiol
, vol.102
, Issue.3
, pp. 237-240
-
-
Blumenstein, J.1
Van Linden, A.2
Kim, W.K.3
Skwara, W.4
Schoenburg, M.5
Arsalan, M.6
Moellmann, H.7
Niederhagen, M.8
Kempfert, J.9
Walther, T.10
-
31
-
-
0041353788
-
Obstruction of St Jude medical valves in the aortic position: Histology and immunohistochemistry of pannus
-
DOI 10.1016/S0022-5223(03)00702-5
-
Teshima H, Hayashida N, Yano H, Nishimi M, Tayama E, Fukunaga S, Akashi H, Kawara T, Aoyagi S (2003) Obstruction of St Jude Medical valves in the aortic position: histology and immunohistochemistry of pannus. J Thorac Cardiovasc Surg 126(2):401-407 (pii:S0022522303007025) (Pubitemid 37048504)
-
(2003)
Journal of Thoracic and Cardiovascular Surgery
, vol.126
, Issue.2
, pp. 401-407
-
-
Teshima, H.1
Hayashida, N.2
Yano, H.3
Nishimi, M.4
Tayama, E.5
Fukunaga, S.6
Akashi, H.7
Kawara, T.8
Aoyagi, S.9
-
32
-
-
0035371010
-
Pathobiologic features and prevention of thrombotic complications associated with prosthetic heart valves: Fundamental principles and the contribution of platelets and thrombin
-
DOI 10.1067/mhj.2001.115492
-
Becker RC, Eisenberg P, Turpie AG (2001) Pathobiologic features and prevention of thrombotic complications associated with prosthetic heart valves: fundamental principles and the contribution of platelets and thrombin. Am Heart J 141(6):1025-1037. doi: 10.1067/mhj.2001.115492 (Pubitemid 32477017)
-
(2001)
American Heart Journal
, vol.141
, Issue.6
, pp. 1025-1037
-
-
Becker, R.C.1
Eisenberg, P.2
Turpie, A.G.G.3
-
33
-
-
10744225814
-
Pannus formation in aortic valve prostheses in the late postoperative period
-
DOI 10.1007/s10047-003-0226-8
-
Kuniyoshi Y, Koja K, Miyagi K, Shimoji M, Uezu T, Arakaki K, Yamashiro S, Mabuni K, Senaha S, Nakasone Y (2003) Pannus formation in aortic valve prostheses in the late postoperative period. J Artif Organs 6(3):179-182. doi: 10.1007/s10047-003-0226-8 (Pubitemid 37229239)
-
(2003)
Journal of Artificial Organs
, vol.6
, Issue.3
, pp. 179-182
-
-
Kuniyoshi, Y.1
Koja, K.2
Miyagi, K.3
Shimoji, M.4
Uezu, T.5
Arakaki, K.6
Yamashiro, S.7
Mabuni, K.8
Senaha, S.9
Nakasone, Y.10
-
34
-
-
0025777562
-
Obstruction of mechanical heart valve prostheses: Clinical aspects and surgical management
-
1:STN:280:DyaK3M7jtFyquw%3D%3D 1993782 10.1016/S0735-1097(10)80178-0
-
Deviri E, Sareli P, Wisenbaugh T, Cronje SL (1991) Obstruction of mechanical heart valve prostheses: clinical aspects and surgical management. J Am Coll Cardiol 17(3):646-650
-
(1991)
J Am Coll Cardiol
, vol.17
, Issue.3
, pp. 646-650
-
-
Deviri, E.1
Sareli, P.2
Wisenbaugh, T.3
Cronje, S.L.4
-
35
-
-
84863718941
-
The risk-to-benefit ratio of transcatheter aortic valve implantation in specific patient cohorts: A single-centre experience
-
10.1007/s00392-012-0426-4 3377897 22350751 10.1007/s00392-012-0426-4
-
Puls M, Viel T, Danner BC, Jacobshagen C, Teucher N, Hanekop G, Schondube F, Hasenfuss G, Seipelt RG, Schillinger W (2012) The risk-to-benefit ratio of transcatheter aortic valve implantation in specific patient cohorts: a single-centre experience. Clin Res Cardiol 101(7):553-563. doi: 10.1007/s00392-012-0426-4
-
(2012)
Clin Res Cardiol
, vol.101
, Issue.7
, pp. 553-563
-
-
Puls, M.1
Viel, T.2
Danner, B.C.3
Jacobshagen, C.4
Teucher, N.5
Hanekop, G.6
Schondube, F.7
Hasenfuss, G.8
Seipelt, R.G.9
Schillinger, W.10
-
36
-
-
0030854354
-
Long-term doppler echocardiographic follow up in normally functioning aortic St. Jude Medical prosthesis
-
Zimmerli M, Kipfer B, Wagdi P (1997) Long-term Doppler echocardiographic follow up in normally functioning aortic St. Jude Medical prosthesis. J Heart Valve Dis 6(5):531-534 (Pubitemid 27405129)
-
(1997)
Journal of Heart Valve Disease
, vol.6
, Issue.5
, pp. 531-534
-
-
Zimmerli, M.1
Kipfer, B.2
Wagdi, P.3
-
37
-
-
33750954927
-
Klappenvitien im erwachsenenalter
-
DOI 10.1007/s00392-006-0458-8
-
Daniel WG, Baumgartner H, Gohlke-Barwolf C, Hanrath P, Horstkotte D, Koch KC, Mugge A, Schafers HJ, Flachskampf FA (2006) Aortic stenosis. Clin Res Cardiol 95(11):620-641. doi: 10.1007/s00392-006-0458-8 (Pubitemid 44732156)
-
(2006)
Clinical Research in Cardiology
, vol.95
, Issue.11
, pp. 620-641
-
-
Daniel, W.G.1
Baumgartner, H.2
Gohlke-Barwolf, C.3
Hanrath, P.4
Horstkotte, D.5
Koch, K.C.6
Mugge, A.7
Schafers, H.J.8
Flachskampf, F.A.9
-
38
-
-
67651155814
-
EuroSCORE overestimates the risk of cardiac surgery: Results from the national registry of the German Society of Thoracic and Cardiovascular Surgery
-
10.1007/s00392-009-0010-8 1:STN:280:DC%2BD1MvivFeiuw%3D%3D 19262978 10.1007/s00392-009-0010-8
-
Gummert JF, Funkat A, Osswald B, Beckmann A, Schiller W, Krian A, Beyersdorf F, Haverich A, Cremer J (2009) EuroSCORE overestimates the risk of cardiac surgery: results from the national registry of the German Society of Thoracic and Cardiovascular Surgery. Clin Res Cardiol 98(6):363-369. doi: 10.1007/s00392-009-0010-8
-
(2009)
Clin Res Cardiol
, vol.98
, Issue.6
, pp. 363-369
-
-
Gummert, J.F.1
Funkat, A.2
Osswald, B.3
Beckmann, A.4
Schiller, W.5
Krian, A.6
Beyersdorf, F.7
Haverich, A.8
Cremer, J.9
-
39
-
-
44049106527
-
Combined cardiac surgical procedures in octogenarians: Operative outcome
-
DOI 10.1007/s00392-007-0615-8
-
Gulbins H, Malkoc A, Ennker J (2008) Combined cardiac surgical procedures in octogenarians: operative outcome. Clin Res Cardiol 97(3):176-180. doi: 10.1007/s00392-007-0615-8 (Pubitemid 351712815)
-
(2008)
Clinical Research in Cardiology
, vol.97
, Issue.3
, pp. 176-180
-
-
Gulbins, H.1
Malkoc, A.2
Ennker, J.3
-
40
-
-
56049114889
-
Prosthesis-patient mismatch in the elderly: Survival, ventricular mass regression, and quality of life
-
10.1016/j.athoracsur.2008.09.005 19021978 10.1016/j.athoracsur.2008.09. 005
-
Vicchio M, Della Corte A, De Santo LS, De Feo M, Caianiello G, Scardone M, Cotrufo M (2008) Prosthesis-patient mismatch in the elderly: survival, ventricular mass regression, and quality of life. Ann Thorac Surg 86(6):1791-1797. doi: 10.1016/j.athoracsur.2008.09.005
-
(2008)
Ann Thorac Surg
, vol.86
, Issue.6
, pp. 1791-1797
-
-
Vicchio, M.1
Della Corte, A.2
De Santo, L.S.3
De Feo, M.4
Caianiello, G.5
Scardone, M.6
Cotrufo, M.7
-
41
-
-
77950574569
-
Moderate patient-prosthesis mismatch has no independent effect on 30-day mortality after isolated aortic valve replacement
-
20334806 10.1016/S0300-8932(10)70061-0 (pii:S0300-8932(10)70061-0)
-
Urso S, Sadaba R, Monleon-Getino T, Aldamiz-Echevarria G (2010) Moderate patient-prosthesis mismatch has no independent effect on 30-day mortality after isolated aortic valve replacement. Rev Esp Cardiol 63(4):409-414 (pii:S0300-8932(10)70061-0)
-
(2010)
Rev Esp Cardiol
, vol.63
, Issue.4
, pp. 409-414
-
-
Urso, S.1
Sadaba, R.2
Monleon-Getino, T.3
Aldamiz-Echevarria, G.4
-
42
-
-
76549135679
-
Patient-prosthesis mismatch in patients with aortic stenosis undergoing isolated aortic valve replacement does not affect survival
-
10.1016/j.athoracsur.2009.07.037 20103206 10.1016/j.athoracsur.2009.07. 037
-
Howell NJ, Keogh BE, Ray D, Bonser RS, Graham TR, Mascaro J, Rooney SJ, Wilson IC, Pagano D (2010) Patient-prosthesis mismatch in patients with aortic stenosis undergoing isolated aortic valve replacement does not affect survival. Ann Thorac Surg 89(1):60-64. doi: 10.1016/j.athoracsur.2009.07.037
-
(2010)
Ann Thorac Surg
, vol.89
, Issue.1
, pp. 60-64
-
-
Howell, N.J.1
Keogh, B.E.2
Ray, D.3
Bonser, R.S.4
Graham, T.R.5
Mascaro, J.6
Rooney, S.J.7
Wilson, I.C.8
Pagano, D.9
-
43
-
-
34547419075
-
Impact of valve prosthesis-patient mismatch on long-term survival and left ventricular mass regression after aortic valve replacement for aortic stenosis
-
DOI 10.1111/j.1540-8191.2007.00414.x
-
Kato Y, Suehiro S, Shibata T, Sasaki Y, Hirai H (2007) Impact of valve prosthesis-patient mismatch on long-term survival and left ventricular mass regression after aortic valve replacement for aortic stenosis. J Card Surg 22(4):314-319. doi: 10.1111/j.1540-8191.2007.00414.x (Pubitemid 47174332)
-
(2007)
Journal of Cardiac Surgery
, vol.22
, Issue.4
, pp. 314-319
-
-
Kato, Y.1
Suehiro, S.2
Shibata, T.3
Sasaki, Y.4
Hirai, H.5
-
44
-
-
84876076856
-
Impact of prosthesis-patient mismatch on early and late mortality after aortic valve replacement
-
10.1186/1749-8090-8-96 3639861 23594366 10.1186/1749-8090-8-96
-
Koene BM, Soliman Hamad MA, Bouma W, Mariani MA, Peels KC, van Dantzig JM, van Straten AH (2013) Impact of prosthesis-patient mismatch on early and late mortality after aortic valve replacement. J Cardiothorac Surg 8(1):96. doi: 10.1186/1749-8090-8-96
-
(2013)
J Cardiothorac Surg
, vol.8
, Issue.1
, pp. 96
-
-
Koene, B.M.1
Soliman Hamad, M.A.2
Bouma, W.3
Mariani, M.A.4
Peels, K.C.5
Van Dantzig, J.M.6
Van Straten, A.H.7
|