메뉴 건너뛰기




Volumn 406, Issue 1, 2014, Pages 367-372

Amperometric bienzyme screen-printed biosensor for the determination of leucine

Author keywords

Amperometric; Biosensor; Leucine; Leucine dehydrogenase; P Hydroxybenzoate hydroxylase; Screen printed electrode

Indexed keywords

BIOSENSORS; BIOSYNTHESIS; ELECTRODES; PROTEINS; VOLTAGE REGULATORS;

EID: 84892995193     PISSN: 16182642     EISSN: 16182650     Source Type: Journal    
DOI: 10.1007/s00216-013-7443-7     Document Type: Article
Times cited : (11)

References (24)
  • 1
    • 84866251432 scopus 로고    scopus 로고
    • Determination of essential amino acids in human serum by a targeting method based on automated spe-lcms/ms: Discrimination between artherosclerotic patients
    • Calderon-Santiago M, Priego-Capote F, Galache-Osuna JG, Luque de Castro MD (2012) Determination of essential amino acids in human serum by a targeting method based on automated SPE-LCMS/MS: discrimination between artherosclerotic patients. J Pharm Biomed Anal 70:476-484
    • (2012) J Pharm Biomed Anal , vol.70 , pp. 476-484
    • Calderon-Santiago, M.1    Priego-Capote, F.2    Galache-Osuna, J.G.3    Luque De Castro, M.D.4
  • 2
    • 37149027613 scopus 로고    scopus 로고
    • Obesity-related elevations in plasma leucine are associated with alterations in enzymes involved in branched-chain amino acid metabolism
    • She PX, Van Horn C, Reid T, Hutson SM, Cooney RN, Lynch CJ (2007) Obesity-related elevations in plasma leucine are associated with alterations in enzymes involved in branched-chain amino acid metabolism. Am J Physiol-Endoc M 293(6):E1552-E1563
    • (2007) Am J Physiol-Endoc M , vol.293 , Issue.6
    • She, P.X.1    Van Horn, C.2    Reid, T.3    Hutson, S.M.4    Cooney, R.N.5    Lynch, C.J.6
  • 3
    • 84867053678 scopus 로고    scopus 로고
    • Effects of leucine and citrulline versus non-essential amino acids on muscle protein synthesis in fasted rat: A common activation pathway?
    • Le Plenier S, Walrand S, Noirt R, Cynober L, Moinard C (2012) Effects of leucine and citrulline versus non-essential amino acids on muscle protein synthesis in fasted rat: a common activation pathway? Amino Acids 43(3):1171-1178
    • (2012) Amino Acids , vol.43 , Issue.3 , pp. 1171-1178
    • Le Plenier, S.1    Walrand, S.2    Noirt, R.3    Cynober, L.4    Moinard, C.5
  • 5
    • 38349135662 scopus 로고    scopus 로고
    • Metabolic and regulatory roles of leucine in neural cells
    • Murin R, Hamprecht B (2008) Metabolic and regulatory roles of leucine in neural cells. Neurochem Res 33(2):279-284
    • (2008) Neurochem Res , vol.33 , Issue.2 , pp. 279-284
    • Murin, R.1    Hamprecht, B.2
  • 7
    • 80054926234 scopus 로고    scopus 로고
    • Hplc with in-capillary optical fiber laser-induced fluorescence detection of picomolar amounts of amino acids by precolumn fluorescence derivatization with fluorescein isothiocyanate
    • He YY, Zhao LJ, Yuan HY, Xu ZM, Tang Y, Xiao D, Choi MMF (2011) HPLC with in-capillary optical fiber laser-induced fluorescence detection of picomolar amounts of amino acids by precolumn fluorescence derivatization with fluorescein isothiocyanate. Chromatographia 74(7-8):541-547
    • (2011) Chromatographia , vol.74 , Issue.7-8 , pp. 541-547
    • He, Y.Y.1    Zhao, L.J.2    Yuan, H.Y.3    Xu, Z.M.4    Tang, Y.5    Xiao, D.6    Choi, M.M.F.7
  • 8
    • 75249107289 scopus 로고    scopus 로고
    • High-performance liquid chromatography-ultraviolet detection method for the simultaneous determination of typical biogenic amines and precursor amino acids. Applications in food chemistry
    • Mazzucco E, Gosetti F, Bobba M, Marengo E, Robotti E, Gennaro MC (2010) High-performance liquid chromatography-ultraviolet detection method for the simultaneous determination of typical biogenic amines and precursor amino acids. Applications in food chemistry. J Agric Food Chem 58(1):127-134
    • (2010) J Agric Food Chem , vol.58 , Issue.1 , pp. 127-134
    • Mazzucco, E.1    Gosetti, F.2    Bobba, M.3    Marengo, E.4    Robotti, E.5    Gennaro, M.C.6
  • 10
    • 0038306717 scopus 로고    scopus 로고
    • Diagnosis of maple syrup urine disease by determination of l-valine, l-isoleucine, l-leucine and lphenylalanine in neonatal blood spots by gas chromatography-mass spectrometry
    • Deng CH, Deng YH (2003) Diagnosis of maple syrup urine disease by determination of L-valine, L-isoleucine, L-leucine and Lphenylalanine in neonatal blood spots by gas chromatography-mass spectrometry. J Chromatogr B 792(2):261-268
    • (2003) J Chromatogr B , vol.792 , Issue.2 , pp. 261-268
    • Deng, C.H.1    Deng, Y.H.2
  • 11
    • 62949190395 scopus 로고    scopus 로고
    • Bio-sniffers for ethanol and acetaldehyde using carbon and ag/agcl coated electrodes
    • Gessei T, Sato H, Kazawa E, Kudo H, Saito H, Mitsubayashi K (2009) Bio-sniffers for ethanol and acetaldehyde using carbon and Ag/AgCl coated electrodes. Microchim Acta 165(1-2):179-186
    • (2009) Microchim Acta , vol.165 , Issue.1-2 , pp. 179-186
    • Gessei, T.1    Sato, H.2    Kazawa, E.3    Kudo, H.4    Saito, H.5    Mitsubayashi, K.6
  • 12
    • 0020527996 scopus 로고
    • A spectrophotometric method for the determination of aminopeptidase activity with leucine dehydrogenase
    • Takamiya S, Ohshima T, Tanizawa K, Soda K (1983) A spectrophotometric method for the determination of aminopeptidase activity with leucine dehydrogenase. Anal Biochem 130(1):266-270
    • (1983) Anal Biochem , vol.130 , Issue.1 , pp. 266-270
    • Takamiya, S.1    Ohshima, T.2    Tanizawa, K.3    Soda, K.4
  • 13
    • 67349138225 scopus 로고    scopus 로고
    • Electrogenerated chemiluminescence for the sensitive detection of leucine using ru(bpy)32+ immobilized on dendritic pd nanoparticle
    • Liu L, Bao J, Fang M, Lf L, Dai Z (2009) Electrogenerated chemiluminescence for the sensitive detection of leucine using Ru(bpy)32+ immobilized on dendritic Pd nanoparticle. Sensors Actuators B Chem 139(2):527-531
    • (2009) Sensors Actuators B Chem , vol.139 , Issue.2 , pp. 527-531
    • Liu, L.1    Bao, J.2    Fang, M.3    Lf, L.4    Dai, Z.5
  • 15
    • 60349111587 scopus 로고    scopus 로고
    • Mammalian cell-based biosensors for pathogens and toxins
    • Banerjee P, Bhunia AK (2009)Mammalian cell-based biosensors for pathogens and toxins. Trends Biotechnol 27(3):179-188
    • (2009) Trends Biotechnol , vol.27 , Issue.3 , pp. 179-188
    • Banerjee, P.1    Bhunia, A.K.2
  • 16
    • 84862193202 scopus 로고    scopus 로고
    • The development and application of a single-cell biosensor for the detection of l-methionine and branched-chain amino acids
    • Mustafi N, Grunberger A, Kohlheyer D, Bott M, Frunzke J (2012) The development and application of a single-cell biosensor for the detection of L-methionine and branched-chain amino acids. Metab Eng 14(4):449-457
    • (2012) Metab Eng , vol.14 , Issue.4 , pp. 449-457
    • Mustafi, N.1    Grunberger, A.2    Kohlheyer, D.3    Bott, M.4    Frunzke, J.5
  • 17
    • 0032998871 scopus 로고    scopus 로고
    • Screenprinted amperometric biosensors for the rapid measurement of l-And d-Amino acids
    • Sarkar P, Tothill IE, Setford SJ, Turner APF (1999) Screenprinted amperometric biosensors for the rapid measurement of L-And D-Amino acids. Analyst 124(6):865-870
    • (1999) Analyst , vol.124 , Issue.6 , pp. 865-870
    • Sarkar, P.1    Tothill, I.E.2    Setford, S.J.3    Turner, A.P.F.4
  • 18
    • 33646418993 scopus 로고    scopus 로고
    • Determination of land d-enantiomers of leucine using amperometric biosensors based on diamond paste
    • Stefan-van Staden RI, Muvhulawa LS (2006) Determination of Land D-enantiomers of leucine using amperometric biosensors based on diamond paste. Instrum Sci Technol 34(4):475-481
    • (2006) Instrum Sci Technol , vol.34 , Issue.4 , pp. 475-481
    • Stefan-Van Staden, R.I.1    Muvhulawa, L.S.2
  • 19
    • 33947606966 scopus 로고    scopus 로고
    • Development of a glucose-6-phosphate biosensor based on coimmobilized p-hydroxybenzoate hydroxylase and glucose-6-phosphate dehydrogenase
    • Cui Y, Barford JP, Renneberg R (2007) Development of a glucose-6-phosphate biosensor based on coimmobilized p-hydroxybenzoate hydroxylase and glucose-6-phosphate dehydrogenase. Biosens Bioelectron 22(11):2754-2758
    • (2007) Biosens Bioelectron , vol.22 , Issue.11 , pp. 2754-2758
    • Cui, Y.1    Barford, J.P.2    Renneberg, R.3
  • 20
    • 35348962088 scopus 로고    scopus 로고
    • Development of an lglutamate biosensor using the coimmobilization of l-glutamate dehydrogenase and p-hydroxybenzoate hydroxylase on a clarktype electrode
    • Cui Y, Barford JP, Renneberg R (2007) Development of an Lglutamate biosensor using the coimmobilization of L-glutamate dehydrogenase and p-hydroxybenzoate hydroxylase on a Clarktype electrode. Sensors Actuators B-Chem 127(2):358-361
    • (2007) Sensors Actuators B-Chem , vol.127 , Issue.2 , pp. 358-361
    • Cui, Y.1    Barford, J.P.2    Renneberg, R.3
  • 21
    • 0036752957 scopus 로고    scopus 로고
    • Plasma amino acid levels with a note on membrane transport: Characteristics, regulation, and metabolic significance
    • Cynober LA (2002) Plasma amino acid levels with a note on membrane transport: characteristics, regulation, and metabolic significance. Nutrition 18(9):761-766
    • (2002) Nutrition , vol.18 , Issue.9 , pp. 761-766
    • Cynober, L.A.1
  • 22
    • 0037173544 scopus 로고    scopus 로고
    • Rapid diagnosis of phenylketonuria and other aminoacidemias by quantitative analysis of amino acids in neonatal blood spots by gas chromatography-mass spectrometry
    • Deng CH, Shang CQ, Hu YM, ZhangXM(2002) Rapid diagnosis of phenylketonuria and other aminoacidemias by quantitative analysis of amino acids in neonatal blood spots by gas chromatography-mass spectrometry. J Chromatogr B-Anal Technol Biomed Life Sci 775(1): 115-120
    • (2002) J Chromatogr B-Anal Technol Biomed Life Sci , vol.775 , Issue.1 , pp. 115-120
    • Deng, C.H.1    Shang, C.Q.2    Hu, Y.M.3    Zhang, X.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.