메뉴 건너뛰기




Volumn 165, Issue 1-2, 2009, Pages 179-186

Bio-sniffers for ethanol and acetaldehyde using carbon and Ag/AgCl coated electrodes

Author keywords

Acetaldehyde; Alcohol metabolic; Biosensor; Breath analysis; Ethanol; Gas monitoring

Indexed keywords


EID: 62949190395     PISSN: 00263672     EISSN: 14365073     Source Type: Journal    
DOI: 10.1007/s00604-008-0117-z     Document Type: Article
Times cited : (17)

References (37)
  • 4
    • 33746863294 scopus 로고    scopus 로고
    • Analysis of human breath with micro extraction techniques and continuous monitoring of carbon dioxide concentration
    • W Ma X Liu J Pawliszyn 2006 Analysis of human breath with micro extraction techniques and continuous monitoring of carbon dioxide concentration Anal Bioanal Chem 385 1398 1408
    • (2006) Anal Bioanal Chem , vol.385 , pp. 1398-1408
    • Ma, W.1    Liu, X.2    Pawliszyn, J.3
  • 5
    • 36849055638 scopus 로고    scopus 로고
    • Monitoring of oxidative and metabolic stress during cardiac surgery by means of breath biomarkers: An observational study
    • F Pabst W Miekisch P Fuchs S Kischkel JK Schubert 2007 Monitoring of oxidative and metabolic stress during cardiac surgery by means of breath biomarkers: an observational study J Cardiothorac Surg 18 37
    • (2007) J Cardiothorac Surg , vol.18 , pp. 37
    • Pabst, F.1    Miekisch, W.2    Fuchs, P.3    Kischkel, S.4    Schubert, J.K.5
  • 6
    • 0026704059 scopus 로고
    • Measuring ethanol in blood and breath for legal purposes: Variability between laboratories and between breath-test instruments
    • AW Jones KM Beylich A Bjørneboe J Ingum J Mørland 1992 Measuring ethanol in blood and breath for legal purposes: variability between laboratories and between breath-test instruments Clin Chem 38 743 747
    • (1992) Clin Chem , vol.38 , pp. 743-747
    • Jones, A.W.1    Beylich, K.M.2    Bjørneboe, A.3    Ingum, J.4    Mørland, J.5
  • 7
    • 0038725901 scopus 로고    scopus 로고
    • Comparison of blood-ethanol concentration in deaths attributed to acute alcohol poisoning and chronic alcoholism
    • AW Jones P Holmgren 2003 Comparison of blood-ethanol concentration in deaths attributed to acute alcohol poisoning and chronic alcoholism J Forensic Sci 48 874 879
    • (2003) J Forensic Sci , vol.48 , pp. 874-879
    • Jones, A.W.1    Holmgren, P.2
  • 8
    • 33846007727 scopus 로고    scopus 로고
    • Genotoxic effects of alcohol in human peripheral lymphocytes modulated by ADH1B and ALDH2 gene polymorphisms
    • H Ishikawa T Ishikawa H Yamamoto A Fukao K Yokoyama 2007 Genotoxic effects of alcohol in human peripheral lymphocytes modulated by ADH1B and ALDH2 gene polymorphisms Mutat Res 615 134 142
    • (2007) Mutat Res , vol.615 , pp. 134-142
    • Ishikawa, H.1    Ishikawa, T.2    Yamamoto, H.3    Fukao, A.4    Yokoyama, K.5
  • 9
    • 23044513106 scopus 로고    scopus 로고
    • Hangover susceptibility in relation to aldehyde dehydrogenase-2 genotype, alcohol flushing, and mean corpuscular volume in Japanese workers
    • M Yokoyama A Yokoyama T Yokoyama K Funazu G Hamana S Kondo T Yamashita H Nakamura 2005 Hangover susceptibility in relation to aldehyde dehydrogenase-2 genotype, alcohol flushing, and mean corpuscular volume in Japanese workers Alcohol Clin Exp Res 29 1165 1171
    • (2005) Alcohol Clin Exp Res , vol.29 , pp. 1165-1171
    • Yokoyama, M.1    Yokoyama, A.2    Yokoyama, T.3    Funazu, K.4    Hamana, G.5    Kondo, S.6    Yamashita, T.7    Nakamura, H.8
  • 10
    • 34249310210 scopus 로고    scopus 로고
    • The role of acetaldehyde in upper digestive tract cancer in alcoholics
    • HK Seitz P Meier 2007 The role of acetaldehyde in upper digestive tract cancer in alcoholics Translational Research 149 293 297
    • (2007) Translational Research , vol.149 , pp. 293-297
    • Seitz, H.K.1    Meier, P.2
  • 11
    • 0345256966 scopus 로고
    • Acetaldehyde
    • WHO World Health Organisation (WHO), International Programme on Chemical Safety
    • WHO (1995) Acetaldehyde. World Health Organisation (WHO), International Programme on Chemical Safety, Environmental Health Criteria 167
    • (1995) Environmental Health Criteria , vol.167
  • 12
    • 34748853187 scopus 로고    scopus 로고
    • Vinyl meeting today's and tomorrow's indoor air quality requirements
    • E Frank Borrelli 2006 Vinyl meeting today's and tomorrow's indoor air quality requirements J Vinyl Addit Technol 13 138 142
    • (2006) J Vinyl Addit Technol , vol.13 , pp. 138-142
    • Frank, E.1    Borrelli2
  • 14
    • 0023924682 scopus 로고
    • Noninvasive estimation of blood alcohol concentrations: Ethanol vapor above the eye
    • HG Giles S Sandrin V Saldivia Y Israel 1988 Noninvasive estimation of blood alcohol concentrations: ethanol vapor above the eye Alcohol Clin Exp Res 12 255 258
    • (1988) Alcohol Clin Exp Res , vol.12 , pp. 255-258
    • Giles, H.G.1    Sandrin, S.2    Saldivia, V.3    Israel, Y.4
  • 15
    • 0019613485 scopus 로고
    • Colorimetric method for determination of ethanol in presence of methanol
    • RT Sane SS Kamat AD Pandit 1981 Colorimetric method for determination of ethanol in presence of methanol J Assoc Off Anal Chem 64 1145 1148
    • (1981) J Assoc off Anal Chem , vol.64 , pp. 1145-1148
    • Sane, R.T.1    Kamat, S.S.2    Pandit, A.D.3
  • 16
    • 0021933062 scopus 로고
    • Gas-liquid chromatographic analysis of ethanol and acetaldehyde in blood with minimal artifactual acetaldehyde formation
    • NA Steenaart DW Clarke JF Brien 1985 Gas-liquid chromatographic analysis of ethanol and acetaldehyde in blood with minimal artifactual acetaldehyde formation J Pharmacol Methods 14 199 212
    • (1985) J Pharmacol Methods , vol.14 , pp. 199-212
    • Steenaart, N.A.1    Clarke, D.W.2    Brien, J.F.3
  • 18
    • 0023060630 scopus 로고
    • Determination of free acetaldehyde in blood as the dinitrophenylhydrazone derivative by high-performance liquid chromatography
    • D Lucas JF Ménez F Berthou Y Pennec HH Floch 1986 Determination of free acetaldehyde in blood as the dinitrophenylhydrazone derivative by high-performance liquid chromatography J Chromatogr 382 57 66
    • (1986) J Chromatogr , vol.382 , pp. 57-66
    • Lucas, D.1    Ménez, J.F.2    Berthou, F.3    Pennec, Y.4    Floch, H.H.5
  • 19
    • 29144508524 scopus 로고    scopus 로고
    • A longitudinal study of ethanol and acetaldehyde in the exhaled breath of healthy volunteers using selected-ion flow-tube mass spectrometry
    • C Turner P Spanel D Smith 2006 A longitudinal study of ethanol and acetaldehyde in the exhaled breath of healthy volunteers using selected-ion flow-tube mass spectrometry Rapid Commun Mass Spectrom 20 61 68
    • (2006) Rapid Commun Mass Spectrom , vol.20 , pp. 61-68
    • Turner, C.1    Spanel, P.2    Smith, D.3
  • 21
    • 40449109054 scopus 로고    scopus 로고
    • Electrochemical glucose biosensors
    • J Wang 2008 Electrochemical glucose biosensors Chem Rev 108 814 825
    • (2008) Chem Rev , vol.108 , pp. 814-825
    • Wang, J.1
  • 22
    • 38349111800 scopus 로고    scopus 로고
    • Amperometric lactate biosensors and their application in (sports) medicine, for life quality and wellbeing
    • N Nikolaus B Strehlitz 2008 Amperometric lactate biosensors and their application in (sports) medicine, for life quality and wellbeing Microchim Acta 160 15 55
    • (2008) Microchim Acta , vol.160 , pp. 15-55
    • Nikolaus, N.1    Strehlitz, B.2
  • 25
    • 55149093900 scopus 로고    scopus 로고
    • Glucose oxidase inhibition in poly(neutral red) mediated enzyme biosensors for heavy metal determination
    • ME Ghica CMA Brett 2008 Glucose oxidase inhibition in poly(neutral red) mediated enzyme biosensors for heavy metal determination Microchim Acta 163 185 193
    • (2008) Microchim Acta , vol.163 , pp. 185-193
    • Ghica, M.E.1    Brett, C.M.A.2
  • 27
    • 47949106571 scopus 로고    scopus 로고
    • Determination of serum alcohol using a disposable biosensor
    • P Luo Y Liu G Xie XX Deng F Song 2008 Determination of serum alcohol using a disposable biosensor Forensic Sci Int 179 192 198
    • (2008) Forensic Sci Int , vol.179 , pp. 192-198
    • Luo, P.1    Liu, Y.2    Xie, G.3    Deng, X.X.4    Song, F.5
  • 28
    • 0037625113 scopus 로고    scopus 로고
    • Prussian Blue based screen printed biosensors with improved characteristics of long-term lifetime and pH stability
    • F Ricci A Amine G Palleschi D Moscone 2003 Prussian Blue based screen printed biosensors with improved characteristics of long-term lifetime and pH stability Biosens Bioelectron 18 65 174
    • (2003) Biosens Bioelectron , vol.18 , pp. 65-174
    • Ricci, F.1    Amine, A.2    Palleschi, G.3    Moscone, D.4
  • 29
    • 0041733719 scopus 로고    scopus 로고
    • Bioelectronic sniffer with a diaphragm flow-cell for acetaldehyde vapor
    • K Mitsubayashi H Amagai H Watanabe Y Nakayama 2003 Bioelectronic sniffer with a diaphragm flow-cell for acetaldehyde vapor Sens Actuators B 95 303 308
    • (2003) Sens Actuators B , vol.95 , pp. 303-308
    • Mitsubayashi, K.1    Amagai, H.2    Watanabe, H.3    Nakayama, Y.4
  • 30
    • 58149475501 scopus 로고    scopus 로고
    • Amperometric biosensors for lactic acid based on baker's and wine yeast
    • doi: 10.1007/s00604-008-0055-9
    • Garjonyte R, Melvydas V, Malinauskas A (2008) Amperometric biosensors for lactic acid based on baker's and wine yeast. Microchim Acta. doi: 10.1007/s00604-008-0055-9
    • (2008) Microchim Acta
    • Garjonyte, R.1    Melvydas, V.2    Malinauskas, A.3
  • 31
    • 0038485542 scopus 로고    scopus 로고
    • Electroanalytical properties of aldehyde biosensors with a hybrid-membrane composed of an enzyme film and a redox Os-polymer film
    • T Yao S Handa 2003 Electroanalytical properties of aldehyde biosensors with a hybrid-membrane composed of an enzyme film and a redox Os-polymer film Anal Sci 19 767 770
    • (2003) Anal Sci , vol.19 , pp. 767-770
    • Yao, T.1    Handa, S.2
  • 32
    • 27444443179 scopus 로고    scopus 로고
    • Mediatorless voltammetric oxidation of NADH and sensing of ethanol
    • CR Raj S Behera 2005 Mediatorless voltammetric oxidation of NADH and sensing of ethanol Biosens Bioelectron 21 949 956
    • (2005) Biosens Bioelectron , vol.21 , pp. 949-956
    • Raj, C.R.1    Behera, S.2
  • 33
    • 33746238523 scopus 로고    scopus 로고
    • Mediator-free amperometric determination of glucose based on direct electron transfer between glucose oxidase and an oxidized boron-doped diamond electrode
    • J Wu Y Qu 2006 Mediator-free amperometric determination of glucose based on direct electron transfer between glucose oxidase and an oxidized boron-doped diamond electrode Anal Bioanal Chem 385 1330 1335
    • (2006) Anal Bioanal Chem , vol.385 , pp. 1330-1335
    • Wu, J.1    Qu, Y.2
  • 36
    • 0036125133 scopus 로고    scopus 로고
    • Development of disposable amperometric sulfur dioxide biosensors based on screen printed electrodes
    • JP Hart AK Abass D Cowell 2002 Development of disposable amperometric sulfur dioxide biosensors based on screen printed electrodes Biosens Bioelectron 17 389 394
    • (2002) Biosens Bioelectron , vol.17 , pp. 389-394
    • Hart, J.P.1    Abass, A.K.2    Cowell, D.3
  • 37
    • 51449118260 scopus 로고    scopus 로고
    • Array of potentiometric sensors for multicomponent analysis of blood serum
    • DPA Correia JMCS Magalhaes AASC Machado 2008 Array of potentiometric sensors for multicomponent analysis of blood serum Microchim Acta 163 131 137
    • (2008) Microchim Acta , vol.163 , pp. 131-137
    • Correia, D.P.A.1    Jmcs, M.2    Aasc, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.