-
1
-
-
11144355852
-
Large-scale recording of neuronal ensembles
-
DOI 10.1038/nn1233
-
G. Buzsaki, "Large-scale recording of neuronal ensembles," Nat. Neurosci., vol. 7, no. 5, pp. 446-451, May 2004. (Pubitemid 38544574)
-
(2004)
Nature Neuroscience
, vol.7
, Issue.5
, pp. 446-451
-
-
Buzsaki, G.1
-
2
-
-
0041315427
-
Massively parallel recording of unit and local field potentials with silicon-based electrodes
-
DOI 10.1152/jn.00116.2003
-
J. Csicsvari, D. A. Henze, B. Jamieson, K. D. Harris, A. Sirota, P. Bartho, K. D. Wise, and G. Buzsaki, "Massively parallel recording of unit and local field potentials with silicon-based electrodes," J. Neurophysiol., vol. 90, no. 2, pp. 1314-1323, Aug. 2003. (Pubitemid 37092608)
-
(2003)
Journal of Neurophysiology
, vol.90
, Issue.2
, pp. 1314-1323
-
-
Csicsvari, J.1
Henze, D.A.2
Jamieson, B.3
Harris, K.D.4
Sirota, A.5
Bartho, P.6
Wise, K.D.7
Buzsaki, G.8
-
3
-
-
0026205082
-
A silicon-based, three-dimensional neural interface: Manufacturing processes for an intracortical electrode array
-
Aug.
-
P. K. Campbell, K. E. Jones, R. J. Huber, K. W. Horch, and R. A. Normann, "A silicon-based, three-dimensional neural interface: Manufacturing processes for an intracortical electrode array," IEEE Trans. Biomed. Eng., vol. 38, no. 8, pp. 758-768, Aug. 1991.
-
(1991)
IEEE Trans. Biomed. Eng.
, vol.38
, Issue.8
, pp. 758-768
-
-
Campbell, P.K.1
Jones, K.E.2
Huber, R.J.3
Horch, K.W.4
Normann, R.A.5
-
4
-
-
29044441759
-
A three-dimensional neural recording microsystem with implantable data compression circuitry
-
DOI 10.1109/JSSC.2005.858479
-
R. H. Olsson and K. D. Wise, "A three-dimensional neural recording microsystem with implantable data compression circuitry," IEEE J. Solid-State Circuits, vol. 40, no. 12, pp. 2796-2804, Dec. 2005. (Pubitemid 41789174)
-
(2005)
IEEE Journal of Solid-State Circuits
, vol.40
, Issue.12
, pp. 2796-2804
-
-
Olsson III, R.H.1
Wise, K.D.2
-
5
-
-
21844471300
-
Band-tunable and multiplexed integrated circuits for simultaneous recording and stimulation with microelectrode arrays
-
DOI 10.1109/TBME.2005.847540
-
R. H. Olsson, III, D. L. Buhl, A. M. Sirota, G. Buzsaki, and K. D. Wise, "Band-tunable and multiplexed integrated circuits for simultaneous recording and stimulation with microelectrode arrays," IEEE Trans. Biomed. Eng., vol. 52, no. 7, pp. 1303-1311, Jul. 2005. (Pubitemid 40961381)
-
(2005)
IEEE Transactions on Biomedical Engineering
, vol.52
, Issue.7
, pp. 1303-1311
-
-
Olsson III, R.H.1
Buhl, D.L.2
Sirota, A.M.3
Buzsaki, G.4
Wise, K.D.5
-
6
-
-
17644389537
-
Polytrodes: High-density silicon electrode arrays for large-scale multiunit recording
-
DOI 10.1152/jn.01023.2004
-
T. J. Blanche, M. A. Spacek, J. F. Hetke, and N. V. Swindale, "Polytrodes: High-density silicon electrode arrays for large-scale multiunit recording," J. Neurophysiol., vol. 93, no. 5, pp. 2987-3000,May 2005. (Pubitemid 40570876)
-
(2005)
Journal of Neurophysiology
, vol.93
, Issue.5
, pp. 2987-3000
-
-
Blanche, T.J.1
Spacek, M.A.2
Hetke, J.F.3
Swindale, N.V.4
-
7
-
-
33846917988
-
Development of a Mieroseale Implantable Neural Interface (MINI) probe system
-
1616207, Proceedings of the 2005 27th Annual International Conference of the Engineering in Medicine and Biology Society, IEEE-EMBS 2005
-
R. J. Vetter, R.M.Miriani, B. E. Casey, K. Kong, J. F. Hetke, and D. R. Kipke, "Development of a microscale implantable neural interface (MINI) probe systems," in Proc. 27th Annual Int. Conf. Eng. Med. Biol. Soc., 2005, pp. 7341-7344. (Pubitemid 46230679)
-
(2005)
Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings
, vol.7
, pp. 7341-7344
-
-
Vetter, R.J.1
Miriani, R.M.2
Casey, B.E.3
Kong, K.4
Hetke, J.F.5
Kipke, D.R.6
-
8
-
-
78649663727
-
An ultra compact integrated front end for wireless neural recording microsystems
-
G. E. Perlin and K. D. Wise, "An ultra compact integrated front end for wireless neural recording microsystems," J. Microelectromech. Syst., vol. 19, no. 6, pp. 1409-1421, 2010.
-
(2010)
J. Microelectromech. Syst.
, vol.19
, Issue.6
, pp. 1409-1421
-
-
Perlin, G.E.1
Wise, K.D.2
-
9
-
-
84862252516
-
Compact wireless neural recording system for small animals using silicon-based probe arrays
-
P. Ruther, T. Holzhammer, S. Herwik, P. D. Rich, J. W. Dalley, O. Paul, and T. Holtzman, "Compact wireless neural recording system for small animals using silicon-based probe arrays," in Proc. Annu. Int. Conf. IEEE Eng. Med. Biol. Soc., 2011, pp. 2284-2287.
-
(2011)
Proc. Annu. Int. Conf. IEEE Eng. Med. Biol. Soc.
, pp. 2284-2287
-
-
Ruther, P.1
Holzhammer, T.2
Herwik, S.3
Rich, P.D.4
Dalley, J.W.5
Paul, O.6
Holtzman, T.7
-
10
-
-
80255129360
-
Two-dimensional multi-channel neural probes with electronic depth control
-
May
-
T. Torfs, A. A. A. Aarts, M. A. Erismis, J. Aslam, R. F. Yazicioglu, K. Seidl, S. Herwik, I. Ulbert, B. Dombovari, R. Fiath, B. P. Kerekes, R. Puers, O. Paul, P. Ruther, C. Van Hoof, and H. P. Neves, "Two-dimensional multi-channel neural probes with electronic depth control," IEEE Trans. Biomed. Circuits Syst., vol. 5, no. 5, pp. 403-412, May 2011.
-
(2011)
IEEE Trans. Biomed. Circuits Syst.
, vol.5
, Issue.5
, pp. 403-412
-
-
Torfs, T.1
Aarts, A.A.A.2
Erismis, M.A.3
Aslam, J.4
Yazicioglu, R.F.5
Seidl, K.6
Herwik, S.7
Ulbert, I.8
Dombovari, B.9
Fiath, R.10
Kerekes, B.P.11
Puers, R.12
Paul, O.13
Ruther, P.14
Van Hoof, C.15
Neves, H.P.16
-
11
-
-
33746600326
-
A novel high channel-count system for acute multisite neuronal recordings
-
DOI 10.1109/TBME.2006.877807, 1658162
-
U. G. Hofmann, A. Folkers, F. Mosch, T. Malina, K. M. L. Menne, G. Biella, P. Fagerstedt, E. De Schutter,W. Jensen, K. Yoshida, D. Hoehl, U. Thomas, M. G. Kindlundh, P. Norlin, and M. de Curtis, "A novel high channel-count system for acute multisite neuronal recordings," IEEE Trans. Biomed. Eng., vol. 53, no. 8, pp. 1672-1677, Aug. 2006. (Pubitemid 44150279)
-
(2006)
IEEE Transactions on Biomedical Engineering
, vol.53
, Issue.8
, pp. 1672-1677
-
-
Hofmann, U.G.1
Folkers, A.2
Mosch, F.3
Malina, T.4
Menne, K.M.L.5
Biella, G.6
Fagerstedt, P.7
De Schutter, E.8
Jensen, W.9
Yoshida, K.10
Hoehl, D.11
Thomas, U.12
Kindlundh, M.G.13
Norlin, P.14
De Curtis, M.15
-
12
-
-
0036645870
-
A 32-site neural recording probe fabricated by DRIE of SOI substrates
-
P. Norlin, M. Kindlundh, A. Mouroux, K. Yoshida, and U. G. Hofmann, "A 32-site neural recording probe fabricated by DRIE of SOI substrates," J. Micromech. Microeng., vol. 12, no. 4, p. 414, 2002.
-
(2002)
J. Micromech. Microeng.
, vol.12
, Issue.4
, pp. 414
-
-
Norlin, P.1
Kindlundh, M.2
Mouroux, A.3
Yoshida, K.4
Hofmann, U.G.5
-
13
-
-
80053969729
-
Multiplexed, high density electrophysiology with nanofabricated neural probes
-
J. Du, T. J. Blanche, R. R. Harrison, H. A. Lester, and S. C.Masmanidis, "Multiplexed, high density electrophysiology with nanofabricated neural probes," PLoS One, vol. 6, no. 10, p. e26204, 2011.
-
(2011)
PLoS One
, vol.6
, Issue.10
-
-
Du, J.1
Blanche, T.J.2
Harrison, R.R.3
Lester, H.A.4
Masmanidis, S.C.5
-
14
-
-
84874531151
-
Nanowire electrodes for high-density stimulation and measurement of neural circuits
-
J. T. Robinson, M. Jorgolli, and H. Park, "Nanowire electrodes for high-density stimulation and measurement of neural circuits," Frontiers in Neural Circuits, vol. 7, no. 38, 2013.
-
(2013)
Frontiers in Neural Circuits
, vol.7
, Issue.38
-
-
Robinson, J.T.1
Jorgolli, M.2
Park, H.3
-
15
-
-
0029623039
-
Tetrodes markedly improve the reliability and yield of multiple single-unit isolation from multi-unit recordings in cat striate cortex
-
DOI 10.1016/0165-0270(95)00085-2
-
C. M. Gray, P. E. Maldonado, M. Wilson, and B. McNaughton, "Tetrodes markedly improve the reliability and yield of multiple single-unit isolation from multi-unit recordings in cat striate cortex," J. Neurosci. Methods, vol. 63, no. 1-2, pp. 43-54, 1995. (Pubitemid 26009962)
-
(1995)
Journal of Neuroscience Methods
, vol.63
, Issue.1-2
, pp. 43-54
-
-
Gray, C.M.1
Maldonado, P.E.2
Wilson, M.3
McNaughton, B.4
-
16
-
-
0033928411
-
Accuracy of tetrode spike separation as determined by simultaneous intracellular and extracellular measurements
-
K. D. Harris, D. A. Henze, J. Csicsvari, H. Hirase, and G. Buzsáki, "Accuracy of tetrode spike separation as determined by simultaneous intracellular and extracellular measurements," J. Neurophysiol., vol. 84, no. 1, pp. 401-414, Jul. 2000. (Pubitemid 30490060)
-
(2000)
Journal of Neurophysiology
, vol.84
, Issue.1
, pp. 401-414
-
-
Harris, K.D.1
Henze, D.A.2
Csicsvari, J.3
Hirase, H.4
Buzsaki, G.5
-
17
-
-
84876586614
-
An implantable 455- active-electrode 52-channel CMOS neural probe
-
C. M. Lopez, A. Andrei, S. Mitra, M. Welkenhuysen, W. Eberle, C. Bartic, R. Puers,R. F. Yazicioglu, andG.Gielen, "An implantable 455- active-electrode 52-channel CMOS neural probe," in IEEE Int. Solid- State Circuits Conf. Dig. Tech. Papers, 2013, pp. 288-289.
-
(2013)
IEEE Int. Solid- State Circuits Conf. Dig. Tech. Papers
, pp. 288-289
-
-
Lopez, C.M.1
Andrei, A.2
Mitra, S.3
Welkenhuysen, M.4
Eberle, W.5
Bartic, C.6
Puers, R.7
Yazicioglu, R.F.8
Gielen, G.9
-
18
-
-
33846258717
-
A low-power integrated circuit for a wireless 100-electrode neural recording system
-
DOI 10.1109/JSSC.2006.886567
-
R. R. Harrison, P. T. Watkins, R. J. Kier, R. O. Lovejoy, D. J. Black, B. Greger, and F. Solzbacher, "A low-power integrated circuit for a wireless 100-electrode neural recording system," IEEE J. Solid-State Circuits, vol. 42, no. 1, pp. 123-133, Jan. 2007. (Pubitemid 46103876)
-
(2007)
IEEE Journal of Solid-State Circuits
, vol.42
, Issue.1
, pp. 123-133
-
-
Harrison, R.R.1
Watkins, P.T.2
Kier, R.J.3
Lovejoy, R.O.4
Black, D.J.5
Greger, B.6
Solzbacher, F.7
-
19
-
-
69249110119
-
A 128- channel 6 mW wireless neural recording IC with spike feature extraction and UWB transmitter
-
Dec.
-
M. S. Chae, Z. Yang, M. R. Yuce, L. Hoang, and W. Liu, "A 128- channel 6 mW wireless neural recording IC with spike feature extraction and UWB transmitter," IEEE Trans. Neural Syst. Rehabil. Eng., vol. 17, no. 4, pp. 312-321, Dec. 2009.
-
(2009)
IEEE Trans. Neural Syst. Rehabil. Eng.
, vol.17
, Issue.4
, pp. 312-321
-
-
Chae, M.S.1
Yang, Z.2
Yuce, M.R.3
Hoang, L.4
Liu, W.5
-
20
-
-
61449148727
-
256-channel neural recording and delta compression microsystem with 3D electrodes
-
Mar.
-
J. N. Y. Aziz, K. Abdelhalim, R. Shulyzki, R. Genov, B. L. Bardakjian, M. Derchansky, D. Serletis, and P. L. Carlen, "256-channel neural recording and delta compression microsystem with 3D electrodes," IEEE J. Solid-State Circuits, vol. 44, no. 3, pp. 995-1005, Mar. 2009.
-
(2009)
IEEE J. Solid-State Circuits
, vol.44
, Issue.3
, pp. 995-1005
-
-
Aziz, J.N.Y.1
Abdelhalim, K.2
Shulyzki, R.3
Genov, R.4
Bardakjian, B.L.5
Derchansky, M.6
Serletis, D.7
Carlen, P.L.8
-
21
-
-
64749087889
-
High-resolution three-dimensional extracellular recording of neuronal activity with microfabricated electrode arrays
-
Mar.
-
J. Du, I. H. Riedel-Kruse, J. C. Nawroth, M. L. Roukes, G. Laurent, and S. C. Masmanidis, "High-resolution three-dimensional extracellular recording of neuronal activity with microfabricated electrode arrays," J. Neurophysiol., vol. 101, no. 3, pp. 1671-1678, Mar. 2009.
-
(2009)
J. Neurophysiol.
, vol.101
, Issue.3
, pp. 1671-1678
-
-
Du, J.1
Riedel-Kruse, I.H.2
Nawroth, J.C.3
Roukes, M.L.4
Laurent, G.5
Masmanidis, S.C.6
-
22
-
-
24344496570
-
Model-based analysis of cortical recording with silicon microelectrodes
-
DOI 10.1016/j.clinph.2005.05.018, PII S1388245705002257
-
M. A. Moffitt and C. C. McIntyre, "Model-based analysis of cortical recording with silicon microelectrodes," Clin. Neurophysiol., vol. 116, no. 9, pp. 2240-2250, Sep. 2005. (Pubitemid 41262214)
-
(2005)
Clinical Neurophysiology
, vol.116
, Issue.9
, pp. 2240-2250
-
-
Moffitt, M.A.1
McIntyre, C.C.2
-
23
-
-
77953426709
-
Improving impedance of implantable microwire multi-electrode arrays by ultrasonic electroplating of durable platinum black
-
S. A. Desai, J. D. Rolston, L. Guo, and S. M. Potter, "Improving impedance of implantable microwire multi-electrode arrays by ultrasonic electroplating of durable platinum black," Front Neuroeng., vol. 3, p. 5, 2010.
-
(2010)
Front Neuroeng.
, vol.3
, pp. 5
-
-
Desai, S.A.1
Rolston, J.D.2
Guo, L.3
Potter, S.M.4
-
24
-
-
77955117475
-
Thermal impact of an active 3-D microelectrode array implanted in the brain
-
DOI 10.1109/TNSRE.2007.908429
-
S. Kim, P. Tathireddy, R. A. Normann, and F. Solzbacher, "Thermal impact of an active 3-D microelectrode array implanted in the brain," IEEE Trans. Neural. Syst. Rehabil. Eng., vol. 15, no. 4, pp. 493-501, Dec. 2007. (Pubitemid 350274176)
-
(2007)
IEEE Transactions on Neural Systems and Rehabilitation Engineering
, vol.15
, Issue.4
, pp. 493-501
-
-
Kim, S.1
Tathireddy, P.2
Normann, R.A.3
Solzbacher, F.4
-
26
-
-
0038718680
-
A low-power low-noise CMOS amplifier for neural recording applications
-
Jun.
-
R. R. Harrison and C. Charles, "A low-power low-noise CMOS amplifier for neural recording applications," IEEE J. Solid-State Circuits, vol. 38, no. 6, pp. 958-965, Jun. 2003.
-
(2003)
IEEE J. Solid-State Circuits
, vol.38
, Issue.6
, pp. 958-965
-
-
Harrison, R.R.1
Charles, C.2
-
27
-
-
84891630839
-
-
Sensitivity Testing-Human Body Model (HBM) Component Level: ANSI/ESD STM5.1-2001. EOS/ESD Assoc. Inc., 2002
-
Sensitivity Testing-Human Body Model (HBM) Component Level: ANSI/ESD STM5.1-2001. EOS/ESD Assoc. Inc., 2002.
-
-
-
-
28
-
-
71249110646
-
A micropower neural recording amplifier with improved noise efficiency factor
-
V. Majidzadeh, A. Schmid, and Y. Leblebici, "A micropower neural recording amplifier with improved noise efficiency factor," in Proc. Eur. Conf. Circuit Theory Design, 2009, pp. 319-322.
-
(2009)
Proc. Eur. Conf. Circuit Theory Design
, pp. 319-322
-
-
Majidzadeh, V.1
Schmid, A.2
Leblebici, Y.3
-
29
-
-
0023561471
-
A micropower low-noise monolithic instrumentation amplifier for medical purposes
-
Jun.
-
M. S. J. Steyaert and W. M. C. Sansen, "A micropower low-noise monolithic instrumentation amplifier for medical purposes," IEEE J. Solid-State Circuits, vol. 22, no. 6, pp. 1163-1168, Jun. 1987.
-
(1987)
IEEE J. Solid-State Circuits
, vol.22
, Issue.6
, pp. 1163-1168
-
-
Steyaert, M.S.J.1
Sansen, W.M.C.2
-
30
-
-
52249113332
-
Design optimization for integrated neural recording systems
-
Sep.
-
M. S. Chae, W. Liu, and M. Sivaprakasam, "Design optimization for integrated neural recording systems," IEEE J. Solid-State Circuits, vol. 43, no. 9, pp. 1931-1939, Sep. 2008.
-
(2008)
IEEE J. Solid-State Circuits
, vol.43
, Issue.9
, pp. 1931-1939
-
-
Chae, M.S.1
Liu, W.2
Sivaprakasam, M.3
-
32
-
-
57849091403
-
A 200 W eight-channel acquisition ASIC for ambulatory EEG systems
-
Dec.
-
R. F. Yazicioglu, P. Merken, R. Puers, and C. Van Hoof, "A 200 W eight-channel acquisition ASIC for ambulatory EEG systems," IEEE J. Solid-State Circuits, vol. 43, no. 12, pp. 3025-3038, Dec. 2008.
-
(2008)
IEEE J. Solid-State Circuits
, vol.43
, Issue.12
, pp. 3025-3038
-
-
Yazicioglu, R.F.1
Merken, P.2
Puers, R.3
Van Hoof, C.4
-
33
-
-
84866482786
-
A 0.013 mm 5 W DC-coupled neural signal acquisition IC with 0.5 v supply
-
jan.
-
R. Muller, S. Gambini, and J. M. Rabaey, "A 0.013 mm 5 W DC-coupled neural signal acquisition IC with 0.5 V supply," IEEE J. Solid-State Circuits, vol. 47, no. 1, pp. 232-243, jan. 2012.
-
(2012)
IEEE J. Solid-State Circuits
, vol.47
, Issue.1
, pp. 232-243
-
-
Muller, R.1
Gambini, S.2
Rabaey, J.M.3
-
34
-
-
84883578286
-
Towards a noise prediction model for in vivo neural recording
-
C. Mora Lopez, M. Welkenhuysen, S. Musa, W. Eberle, C. Bartic, R. Puers, and G. Gielen, "Towards a noise prediction model for in vivo neural recording," in Proc. Annu. Int. Conf. IEEE Eng. Med. Biol. Soc., 2012, pp. 759-762.
-
(2012)
Proc. Annu. Int. Conf. IEEE Eng. Med. Biol. Soc.
, pp. 759-762
-
-
Mora Lopez, C.1
Welkenhuysen, M.2
Musa, S.3
Eberle, W.4
Bartic, C.5
Puers, R.6
Gielen, G.7
-
36
-
-
84860487682
-
A multichannel integrated circuit for electrical recording of neural activity, with independent channel programmability
-
Apr.
-
C. Mora Lopez, D. Prodanov, D. Braeken, I. Gligorijevic, W. Eberle, C. Bartic, R. Puers, and G. Gielen, "A multichannel integrated circuit for electrical recording of neural activity, with independent channel programmability," IEEE Trans. Biomed. Circuits Syst., vol. 6, no. 2, pp. 101-110, Apr. 2012.
-
(2012)
IEEE Trans. Biomed. Circuits Syst.
, vol.6
, Issue.2
, pp. 101-110
-
-
Mora Lopez, C.1
Prodanov, D.2
Braeken, D.3
Gligorijevic, I.4
Eberle, W.5
Bartic, C.6
Puers, R.7
Gielen, G.8
-
37
-
-
3042526258
-
Unsupervised spike detection and sorting with wavelets and superparamagnetic clustering
-
DOI 10.1162/089976604774201631
-
R. Q. Quiroga, Z. Nadasdy, and Y. Ben-Shaul, "Unsupervised spike detection and sortingwithwavelets and superparamagnetic clustering," Neural. Computation., vol. 16, no. 8, pp. 1661-1687, 2004. (Pubitemid 38835137)
-
(2004)
Neural Computation
, vol.16
, Issue.8
, pp. 1661-1687
-
-
Quiroga, R.Q.1
Nadasdy, Z.2
Ben-Shaul, Y.3
-
38
-
-
33644857809
-
Online detection and sorting of extracellularly recorded action potentials in human medial temporal lobe recordings, in vivo
-
DOI 10.1016/j.jneumeth.2005.12.033, PII S0165027006000033
-
U. Rutishauser, E. M. Schuman, and A. N. Mamelak, "Online detection and sorting of extracellularly recorded action potentials in human medial temporal lobe recordings, in vivo," J. Neurosci. Methods, vol. 154, no. 1-2, pp. 204-224, Jun. 2006. (Pubitemid 43833330)
-
(2006)
Journal of Neuroscience Methods
, vol.154
, Issue.1-2
, pp. 204-224
-
-
Rutishauser, U.1
Schuman, E.M.2
Mamelak, A.N.3
-
39
-
-
84859721360
-
HermesE: A 96-channel full data rate direct neural interface in 0.13 m CMOS
-
Apr.
-
H. Gao, R. M. Walker, P. Nuyujukian, K. A. A. Makinwa, K. V. Shenoy, B. Murmann, and T. H. Meng, "HermesE: A 96-channel full data rate direct neural interface in 0.13 m CMOS," IEEE J. Solid-State Circuits, vol. 47, no. 4, pp. 1043-1055, Apr. 2012.
-
(2012)
IEEE J. Solid-State Circuits
, vol.47
, Issue.4
, pp. 1043-1055
-
-
Gao, H.1
Walker, R.M.2
Nuyujukian, P.3
Makinwa, K.A.A.4
Shenoy, K.V.5
Murmann, B.6
Meng, T.H.7
|