메뉴 건너뛰기




Volumn 22, Issue 12, 2013, Pages 2770-2776

Deviation analysis of C2 translaminar screw placement assisted by a novel rapid prototyping drill template: A cadaveric study

Author keywords

C2 translaminar screws; Computer assisted; Personalized drill template; Post pre registration; Rapid prototyping

Indexed keywords

ADULT; ARTICLE; BODY POSITION; BONE SCREW; CADAVER; CERVICAL SPINE; COMPUTER MODEL; COMPUTER PROGRAM; CONE BEAM COMPUTED TOMOGRAPHY; CONTROLLED STUDY; CORTICAL BONE; DRILL GUIDE; FEMALE; HUMAN; MALE; MEASUREMENT ACCURACY; PRIORITY JOURNAL; SURGICAL DRILL; SURGICAL PATIENT;

EID: 84890488873     PISSN: 09406719     EISSN: 14320932     Source Type: Journal    
DOI: 10.1007/s00586-013-2993-0     Document Type: Article
Times cited : (50)

References (30)
  • 1
    • 79960021184 scopus 로고    scopus 로고
    • Posterior C2 instrumentation: Accuracy and complications associated with four techniques
    • 21289565 10.1097/BRS.0b013e3181fdaf06
    • Bransford RJ, Russo AJ, Freeborn M, et al. (2011) Posterior C2 instrumentation: accuracy and complications associated with four techniques. Spine 36:E936-E943
    • (2011) Spine , vol.36
    • Bransford, R.J.1    Russo, A.J.2    Freeborn, M.3
  • 2
    • 80052316275 scopus 로고    scopus 로고
    • C2 laminar screw and C1-2 transarticular screw combined with C1 laminar hooks for atlantoaxial instability with unilateral vertebral artery injury
    • 21331546 10.1007/s00402-011-1277-6
    • Guo Q, Liu J, Ni B, et al. (2011) C2 laminar screw and C1-2 transarticular screw combined with C1 laminar hooks for atlantoaxial instability with unilateral vertebral artery injury. Arch Orthop Trauma Surg 131:1207-1210
    • (2011) Arch Orthop Trauma Surg , vol.131 , pp. 1207-1210
    • Guo, Q.1    Liu, J.2    Ni, B.3
  • 3
    • 77951296468 scopus 로고    scopus 로고
    • Clinical and radiologic outcome of laminar screw at C2 and C7 for posterior instrumentation - Review of 25 cases and comparison of C2 and C7 intralaminar screw fixation
    • 20860937 10.1016/j.surneu.2009.06.010
    • Hong JT, Yi JS, Kim JT, et al. (2010) Clinical and radiologic outcome of laminar screw at C2 and C7 for posterior instrumentation - review of 25 cases and comparison of C2 and C7 intralaminar screw fixation. World Neurosurg 73:112-118
    • (2010) World Neurosurg , vol.73 , pp. 112-118
    • Hong, J.T.1    Yi, J.S.2    Kim, J.T.3
  • 4
    • 77952545543 scopus 로고    scopus 로고
    • Clinical and radiological comparison of treatment of atlantoaxial instability by posterior C1-C2 transarticular screw fixation or C1 lateral mass-C2 pedicle screw fixation
    • 20399666 10.1016/j.jocn.2009.10.008
    • Lee SH, Kim ES, Sung JK, et al. (2010) Clinical and radiological comparison of treatment of atlantoaxial instability by posterior C1-C2 transarticular screw fixation or C1 lateral mass-C2 pedicle screw fixation. J Clin Neurosci 17:886-892
    • (2010) J Clin Neurosci , vol.17 , pp. 886-892
    • Lee, S.H.1    Kim, E.S.2    Sung, J.K.3
  • 5
    • 0028284239 scopus 로고
    • Plate and screw fixation for atlanto-axial subluxation
    • 7998495 10.1007/BF01400872 1:STN:280:DyaK2M%2FptFWgtA%3D%3D
    • Goel A, Laheri V (1994) Plate and screw fixation for atlanto-axial subluxation. Acta Neurochir 129:47-53
    • (1994) Acta Neurochir , vol.129 , pp. 47-53
    • Goel, A.1    Laheri, V.2
  • 6
    • 0036954405 scopus 로고    scopus 로고
    • Atlantoaxial fixation using plate and screw method: A report of 160 treated patients
    • 12445339
    • Goel A, Desai KI, Muzumdar DP (2002) Atlantoaxial fixation using plate and screw method: a report of 160 treated patients. Neurosurgery 51:1351-1356
    • (2002) Neurosurgery , vol.51 , pp. 1351-1356
    • Goel, A.1    Desai, K.I.2    Muzumdar, D.P.3
  • 7
    • 0035890208 scopus 로고    scopus 로고
    • Posterior C1-C2 fusion with polyaxial screw and rod fixation
    • 11707712 10.1097/00007632-200111150-00014 1:STN:280: DC%2BD3MnlsV2isA%3D%3D
    • Harms J, Melcher RP (2001) Posterior C1-C2 fusion with polyaxial screw and rod fixation. Spine 26:2467-2471
    • (2001) Spine , vol.26 , pp. 2467-2471
    • Harms, J.1    Melcher, R.P.2
  • 8
    • 0026618885 scopus 로고
    • Primary posterior fusion C1/2 in odontoid fractures: Indications, technique, and results of transarticular screw fixation
    • 1490045 10.1097/00002517-199212000-00012 1:STN:280:DyaK3s7ksVyntg%3D%3D
    • Jeanneret B, Magerl F (1992) Primary posterior fusion C1/2 in odontoid fractures: indications, technique, and results of transarticular screw fixation. J Spinal Disord 5:464-475
    • (1992) J Spinal Disord , vol.5 , pp. 464-475
    • Jeanneret, B.1    Magerl, F.2
  • 9
    • 74249097996 scopus 로고    scopus 로고
    • Biomechanical assessment of bilateral C1 laminar hook and C1-2 transarticular screws and bone graft for atlantoaxial instability
    • 19956032 10.1097/BSD.0b013e31818da3fe
    • Guo X, Ni B, Zhao W, et al. (2009) Biomechanical assessment of bilateral C1 laminar hook and C1-2 transarticular screws and bone graft for atlantoaxial instability. J Spinal Disord Tech 22:578-585
    • (2009) J Spinal Disord Tech , vol.22 , pp. 578-585
    • Guo, X.1    Ni, B.2    Zhao, W.3
  • 10
    • 85027954734 scopus 로고    scopus 로고
    • Comparison of the anatomic risk for vertebral artery injury associated with percutaneous atlantoaxial anterior and posterior transarticular screws
    • 22728075 10.1016/j.spinee.2012.05.010
    • Xu H, Chi YL, Wang XY, et al. (2012) Comparison of the anatomic risk for vertebral artery injury associated with percutaneous atlantoaxial anterior and posterior transarticular screws. Spine J 12:656-662
    • (2012) Spine J , vol.12 , pp. 656-662
    • Xu, H.1    Chi, Y.L.2    Wang, X.Y.3
  • 11
    • 1842686189 scopus 로고    scopus 로고
    • Posterior C2 fixation using bilateral, crossing C2 laminar screws: Case series and technical note
    • 15260101
    • Wright NM (2004) Posterior C2 fixation using bilateral, crossing C2 laminar screws: case series and technical note. J Spinal Disord Tech 17:158-162
    • (2004) J Spinal Disord Tech , vol.17 , pp. 158-162
    • Wright, N.M.1
  • 12
    • 33644884982 scopus 로고    scopus 로고
    • Pediatric atlantoaxial fixation with bilateral, crossing C-2 translaminar screws
    • 16509484
    • Leonard JR, Wright NM (2006) Pediatric atlantoaxial fixation with bilateral, crossing C-2 translaminar screws. J Neurosurg 104:59-63
    • (2006) J Neurosurg , vol.104 , pp. 59-63
    • Leonard, J.R.1    Wright, N.M.2
  • 13
    • 32944464250 scopus 로고    scopus 로고
    • Translaminar rigid screw fixation of the axis
    • 16302639 10.3171/spi.2005.3.5.0409
    • Wright NM (2005) Translaminar rigid screw fixation of the axis. J Neurosurg Spine 3:409-414
    • (2005) J Neurosurg Spine , vol.3 , pp. 409-414
    • Wright, N.M.1
  • 14
    • 77956910984 scopus 로고    scopus 로고
    • Clinical application of C2 laminar screw technique
    • 20524135 10.1007/s00586-010-1447-1
    • Ma W, Feng L, Xu R, et al. (2010) Clinical application of C2 laminar screw technique. Eur Spine J 19:1312-1317
    • (2010) Eur Spine J , vol.19 , pp. 1312-1317
    • Ma, W.1    Feng, L.2    Xu, R.3
  • 15
    • 41349107389 scopus 로고    scopus 로고
    • Application of laminar screws to posterior fusion of cervical spine: Measurement of the cervical vertebral arch diameter with a navigation system
    • 18344855 10.1097/BRS.0b013e318166aa76
    • Nakanishi K, Tanaka M, Sugimoto Y, et al. (2008) Application of laminar screws to posterior fusion of cervical spine: measurement of the cervical vertebral arch diameter with a navigation system. Spine 33:620-623
    • (2008) Spine , vol.33 , pp. 620-623
    • Nakanishi, K.1    Tanaka, M.2    Sugimoto, Y.3
  • 16
    • 84865146836 scopus 로고    scopus 로고
    • Posterior cervical spine arthrodesis incorporating C2 laminar screw fixation in the treatment of cervical spine injury
    • 22009905 10.1111/j.1757-7861.2009.00062.x
    • Hu Y, Gu YJ, Ye PH, et al. (2010) Posterior cervical spine arthrodesis incorporating C2 laminar screw fixation in the treatment of cervical spine injury. Orthop Surg 2:32-37
    • (2010) Orthop Surg , vol.2 , pp. 32-37
    • Hu, Y.1    Gu, Y.J.2    Ye, P.H.3
  • 17
    • 33745792102 scopus 로고    scopus 로고
    • Biomechanical comparison of four C1 to C2 rigid fixative techniques: Anterior transarticular, posterior transarticular, C1 to C2 pedicle, and C1 to C2 intralaminar screws
    • 16528192 10.1227/01.NEU.0000197222.05299.31
    • Lapsiwala SB, Anderson PA, Oza A, et al. (2006) Biomechanical comparison of four C1 to C2 rigid fixative techniques: anterior transarticular, posterior transarticular, C1 to C2 pedicle, and C1 to C2 intralaminar screws. Neurosurgery 58:516-521
    • (2006) Neurosurgery , vol.58 , pp. 516-521
    • Lapsiwala, S.B.1    Anderson, P.A.2    Oza, A.3
  • 18
    • 70349665247 scopus 로고    scopus 로고
    • A novel computer-assisted drill guide template for placement of C2 laminar screws
    • 19517142 10.1007/s00586-009-1051-4
    • Lu S, Xu YQ, Zhang YZ, et al. (2009) A novel computer-assisted drill guide template for placement of C2 laminar screws. Eur Spine J 18:1379-1385
    • (2009) Eur Spine J , vol.18 , pp. 1379-1385
    • Lu, S.1    Xu, Y.Q.2    Zhang, Y.Z.3
  • 19
    • 77956893671 scopus 로고    scopus 로고
    • Pedicle versus laminar screws: What provides more suitable C2 fixation in congenital C2-3 fusion patients?
    • 20440519 10.1007/s00586-010-1418-6
    • Wang S, Wang C, Passias PG, et al. (2010) Pedicle versus laminar screws: what provides more suitable C2 fixation in congenital C2-3 fusion patients? Eur Spine J 19:1306-1311
    • (2010) Eur Spine J , vol.19 , pp. 1306-1311
    • Wang, S.1    Wang, C.2    Passias, P.G.3
  • 20
    • 84864285689 scopus 로고    scopus 로고
    • Feasibility of C2 Translaminar Screw as an alternative or salvage of C2 pedicle screws in atlantoaxial instability
    • 21666509 10.1097/BSD.0b013e318218a4f7
    • Park JS, Cho DC, Sung JK (2012) Feasibility of C2 Translaminar Screw as an alternative or salvage of C2 pedicle screws in atlantoaxial instability. J Spinal Disord Tech 25:254-258
    • (2012) J Spinal Disord Tech , vol.25 , pp. 254-258
    • Park, J.S.1    Cho, D.C.2    Sung, J.K.3
  • 21
    • 37349021761 scopus 로고    scopus 로고
    • Cervical crossing laminar screws: Early clinical results and complications
    • 18091245 10.1227/01.neu.0000303987.49870.7b
    • Wang MY (2007) Cervical crossing laminar screws: early clinical results and complications. Neurosurgery 61:311-315
    • (2007) Neurosurgery , vol.61 , pp. 311-315
    • Wang, M.Y.1
  • 22
    • 33745784887 scopus 로고    scopus 로고
    • C2 crossing laminar screws: Cadaveric morphometric analysis
    • 16888557 10.1227/01.NEU.0000219900.24467.32
    • Wang MY (2006) C2 crossing laminar screws: cadaveric morphometric analysis. Neurosurgery 59:ONS84-ONS88
    • (2006) Neurosurgery , vol.59
    • Wang, M.Y.1
  • 23
    • 70449535533 scopus 로고    scopus 로고
    • Modification of Wright's technique for C2 translaminar screw fixation: Technical note
    • 19657582 10.1007/s00701-009-0459-2 1:STN:280:DC%2BD1MjjtlSiuw%3D%3D
    • Kabir SMR, Casey AT (2009) Modification of Wright's technique for C2 translaminar screw fixation: technical note. Acta Neurochir 151:1543-1547
    • (2009) Acta Neurochir , vol.151 , pp. 1543-1547
    • Kabir, S.M.R.1    Casey, A.T.2
  • 24
    • 79953664305 scopus 로고    scopus 로고
    • Axial translaminar screw placement using three-dimensional fluoroscopy-based navigation
    • 1:STN:280:DC%2BC3M7nt1Chug%3D%3D
    • Rajasekaran S, Avadhani A, Shetty AP (2011) Axial translaminar screw placement using three-dimensional fluoroscopy-based navigation. Singap Med J 52:15-18
    • (2011) Singap Med J , vol.52 , pp. 15-18
    • Rajasekaran, S.1    Avadhani, A.2    Shetty, A.P.3
  • 25
    • 42149164337 scopus 로고    scopus 로고
    • Placement of C2 laminar screws using three-dimensional fluoroscopy-based image guidance
    • 18034268 10.1007/s00586-007-0557-x
    • Nottmeier EW, Foy AB (2008) Placement of C2 laminar screws using three-dimensional fluoroscopy-based image guidance. Eur Spine J 17:610-615
    • (2008) Eur Spine J , vol.17 , pp. 610-615
    • Nottmeier, E.W.1    Foy, A.B.2
  • 26
    • 37349080177 scopus 로고    scopus 로고
    • Accuracy of intraoperative plain radiographs to detect violations of intralaminar screws placed into the C2 vertebrae: A reliability study
    • 18091498 10.1097/BRS.0b013e31815cdab9
    • Lehman RA Jr, Sasso RC, Helgeson MD, et al. (2007) Accuracy of intraoperative plain radiographs to detect violations of intralaminar screws placed into the C2 vertebrae: a reliability study. Spine 32:3036-3040
    • (2007) Spine , vol.32 , pp. 3036-3040
    • Lehman, Jr.R.A.1    Sasso, R.C.2    Helgeson, M.D.3
  • 27
    • 80051905427 scopus 로고    scopus 로고
    • Efficacy and accuracy of a novel rapid prototyping drill template for cervical pedicle screw placement
    • 21838535 10.3109/10929088.2011.605173
    • Lu S, Xu YQ, Chen GP, et al. (2011) Efficacy and accuracy of a novel rapid prototyping drill template for cervical pedicle screw placement. Comput Aided Surg 16:240-248
    • (2011) Comput Aided Surg , vol.16 , pp. 240-248
    • Lu, S.1    Xu, Y.Q.2    Chen, G.P.3
  • 28
    • 84868647226 scopus 로고    scopus 로고
    • Development of a new technique for pedicle screw and magerl screw insertion using a 3-dimensional image guide
    • 22531473 10.1097/BRS.0b013e31825ab547
    • Kawaguchi Y, Nakano M, Yasuda T, et al. (2012) Development of a new technique for pedicle screw and magerl screw insertion using a 3-dimensional image guide. Spine 37:1983-1988
    • (2012) Spine , vol.37 , pp. 1983-1988
    • Kawaguchi, Y.1    Nakano, M.2    Yasuda, T.3
  • 29
    • 0035875841 scopus 로고    scopus 로고
    • Three-dimensional computed tomography-based, personalized drill guide for posterior cervical stabilization at C1-C2
    • 11426150 10.1097/00007632-200106150-00017 1:STN:280: DC%2BD3MzmsVOlsA%3D%3D
    • Goffin J, Van Brussel K, Martens K, et al. (2001) Three-dimensional computed tomography-based, personalized drill guide for posterior cervical stabilization at C1-C2. Spine 26:1343-1347
    • (2001) Spine , vol.26 , pp. 1343-1347
    • Goffin, J.1    Van Brussel, K.2    Martens, K.3
  • 30
    • 0036015571 scopus 로고    scopus 로고
    • Image-based planning and validation of C1-C2 transarticular screw fixation using personalized drill guides
    • 12173879 10.3109/10929080209146015
    • Van Cleynenbreugel J, Schutyser F, Goffin J, et al. (2002) Image-based planning and validation of C1-C2 transarticular screw fixation using personalized drill guides. Comput Aided Surg 7:41-48
    • (2002) Comput Aided Surg , vol.7 , pp. 41-48
    • Van Cleynenbreugel, J.1    Schutyser, F.2    Goffin, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.