1
-
-
14744298337
-
Atlantoaxial transarticular screw fixation: A review of surgical indications, fusion rate, complications, and lessons learned in 191 adult patients
-
Gluf WM, Schmidt MH, Apfelbaum RI. Atlantoaxial transarticular screw fixation: a review of surgical indications, fusion rate, complications, and lessons learned in 191 adult patients. J Neurosurg Spine. 2005;2:155-163.
-
(2005)
J Neurosurg Spine
, vol.2
, pp. 155-163
-
-
Gluf, W.M.1
Schmidt, M.H.2
Apfelbaum, R.I.3
-
2
-
-
0030973318
-
Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique
-
Madawi AA, Casey AT, Solanki GA, et al. Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique. J Neurosurg. 1997;86:961-968. (Pubitemid 27230138)
-
(1997)
Journal of Neurosurgery
, vol.86
, Issue.6
, pp. 961-968
-
-
Madawi, A.A.1
Casey, A.T.H.2
Solanki, G.A.3
Tuite, G.4
Veres, R.5
Crockard, H.A.6
-
3
-
-
41749096599
-
Vertebral artery injury during cervical spine surgery: A survey of more than 5600 operations
-
DOI 10.1097/BRS.0b013e31816957a7, PII 0000763220080401000012
-
Neo M, Fujibayashi S, Miyata M, et al. Vertebral artery injury during cervical spine surgery: a survey of more than 5600 operations. Spine. 2008;33:779-785. (Pubitemid 351489415)
-
(2008)
Spine
, vol.33
, Issue.7
, pp. 779-785
-
-
Neo, M.1
Fujibayashi, S.2
Miyata, M.3
Takemoto, M.4
Nakamura, T.5
-
4
-
-
0031896021
-
Vertebral artery injury in C1-2 transarticular screw fixation: Results of a survey of the AANS/CNS section on disorders of the spine and peripheral nerves
-
Wright NM, Lauryssen C. Vertebral artery injury in C1-2 transarticular screw fixation: results of a survey of the AANS/ CNS section on disorders of the spine and peripheral nerves. American Association of Neurological Surgeons/Congress of Neurological Surgeons. J Neurosurg. 1998;88:634-640. (Pubitemid 28145204)
-
(1998)
Journal of Neurosurgery
, vol.88
, Issue.4
, pp. 634-640
-
-
Wright, N.M.1
Lauryssen, C.2
-
5
-
-
77954536009
-
Accuracy and complications of transpedicular C2 screw placement without the use of spinal navigation
-
Mueller CA, Roesseler L, Podlogar M, et al. Accuracy and complications of transpedicular C2 screw placement without the use of spinal navigation. Eur Spine J. 2010;19:809-814.
-
(2010)
Eur Spine J
, vol.19
, pp. 809-814
-
-
Mueller, C.A.1
Roesseler, L.2
Podlogar, M.3
-
6
-
-
68549122780
-
Undetected vertebral artery groove and foramen violations during C1 lateral mass and C2 pedicle screw placement
-
Yeom JS, Buchowski JM, Park KW, et al. Undetected vertebral artery groove and foramen violations during C1 lateral mass and C2 pedicle screw placement. Spine. 2008;33:E942-E949.
-
(2008)
Spine
, vol.33
-
-
Yeom, J.S.1
Buchowski, J.M.2
Park, K.W.3
-
7
-
-
1842686189
-
Posterior C2 fixation using bilateral crossing C2 laminar screws: Case series and technical note
-
Wright NM. Posterior C2 fixation using bilateral crossing C2 laminar screws: case series and technical note. J Spinal Disord Tech. 2004;17:158-162.
-
(2004)
J Spinal Disord Tech
, vol.17
, pp. 158-162
-
-
Wright, N.M.1
-
8
-
-
0026618885
-
Primary posterior fusion C 1/2 in odontoid fractures: Indications, technique, and results of transarticular screw fixation
-
Jeanneret B, Magerl F. Primary posterior fusion C1/2 in odontoid fractures: indications, technique, and results of transarticular screw fixation. J Spinal Disord. 1992;5:464-475. (Pubitemid 23001672)
-
(1992)
Journal of Spinal Disorders
, vol.5
, Issue.4
, pp. 464-475
-
-
Jeanneret, B.1
Magerl, F.2
-
9
-
-
0035890208
-
Posterior C1-C2 fusion with polyaxial screw and rod fixation
-
DOI 10.1097/00007632-200111150-00014
-
Harms J, Melcher RP. Posterior C1-C2 fusion with polyaxial screw and rod fixation. Spine. 2001;26:2467-2471. (Pubitemid 33065058)
-
(2001)
Spine
, vol.26
, Issue.22
, pp. 2467-2471
-
-
Harms, J.1
Melcher, R.P.2
-
10
-
-
33745712021
-
Comparison of the anatomical risk for vertebral artery injury associated with the C2-pedicle screw and atlantoaxial transarticular screw
-
DOI 10.1097/01.brs.0000224516.29747.52, PII 0000763220060701000030
-
Yoshida M, Neo M, Fujibayashi S, et al. Comparison of the anatomical risk for vertebral artery injury associated with the C2- pedicle screw and atlantoaxial transarticular screw. Spine. 2006;31:E513-E517. (Pubitemid 43999956)
-
(2006)
Spine
, vol.31
, Issue.15
-
-
Yoshida, M.1
Neo, M.2
Fujibayashi, S.3
Nakamura, T.4
-
11
-
-
0037335825
-
Anatomic study of the axis for surgical planning of transarticular screw fixation
-
Igarashi T, Kikuchi S, Sato K, et al. Anatomic study of the axis for surgical planning of transarticular screw fixation. Clin Orthop Relat Res. 2003;408:162-166. (Pubitemid 36307502)
-
(2003)
Clinical Orthopaedics and Related Research
, Issue.408
, pp. 162-166
-
-
Igarashi, T.1
Kikuchi, S.2
Sato, K.3
Kayama, S.4
Otani, K.5
-
12
-
-
77952115827
-
Anatomical considerations for subaxial (C2) pedicle screw placement: A radiographic study with computed tomography in 93 patients
-
Smith ZA, Bistazzoni S, Onibokun A, et al. Anatomical considerations for subaxial (C2) pedicle screw placement: a radiographic study with computed tomography in 93 patients. J Spinal Disord Tech. 2010;23:176-179.
-
(2010)
J Spinal Disord Tech
, vol.23
, pp. 176-179
-
-
Smith, Z.A.1
Bistazzoni, S.2
Onibokun, A.3
-
13
-
-
77957717698
-
Clinical and radiologic outcome of laminar screw at C2 and C7 for posterior instrumentation-review of 25 cases and comparison of C2 and C7 intralaminar screw fixation
-
[Epub ahead of print]
-
Hong JT, Yi JS, Kim JT, et al. Clinical and radiologic outcome of laminar screw at C2 and C7 for posterior instrumentation-review of 25 cases and comparison of C2 and C7 intralaminar screw fixation. Surg Neurol. 2009. [Epub ahead of print].
-
(2009)
Surg Neurol
-
-
Hong, J.T.1
Yi, J.S.2
Kim, J.T.3
-
14
-
-
45949088946
-
Modification of Wright's technique for placement of bilateral crossing C2 translaminar screws: Technical note
-
DOI 10.1016/j.spinee.2007.06.008, PII S1529943007002604
-
Jea A, Sheth RN, Vanni S, et al. Modification of Wright's technique for placement of bilateral crossing C2 translaminar screws: technical note. Spine J. 2008;8:656-660. (Pubitemid 351893135)
-
(2008)
Spine Journal
, vol.8
, Issue.4
, pp. 656-660
-
-
Jea, A.1
Sheth, R.N.2
Vanni, S.3
Green, B.A.4
Levi, A.D.5
-
15
-
-
70449535533
-
Modification of Wright's technique for C2 translaminar screw fixation: Technical note
-
Kabir SM, Casey AT. Modification of Wright's technique for C2 translaminar screw fixation: technical note. Acta Neurochir (Wien). 2009;151:1543-1547.
-
(2009)
Acta Neurochir (Wien)
, vol.151
, pp. 1543-1547
-
-
Kabir, S.M.1
Casey, A.T.2
-
16
-
-
37349021761
-
Cervical crossing laminar screws: Early clinical results and complications
-
Wang MY. Cervical crossing laminar screws: early clinical results and complications. Neurosurgery. 2007;61:311-335.
-
(2007)
Neurosurgery
, vol.61
, pp. 311-335
-
-
Wang, M.Y.1
-
17
-
-
67651151476
-
Translaminar versus pedicle screw fixation of C2: Comparison of surgical morbidity and accuracy of 313 consecutive screws
-
discussion 348-349
-
Parker SL, McGirt MJ, Garcés-Ambrossi GL, et al. Translaminar versus pedicle screw fixation of C2: comparison of surgical morbidity and accuracy of 313 consecutive screws. Neurosurgery. 2009;64:343-38; discussion 348-349.
-
(2009)
Neurosurgery
, vol.64
, pp. 343-438
-
-
Parker, S.L.1
McGirt, M.J.2
Garces-Ambrossi, G.L.3
-
18
-
-
35848942147
-
Atlantoaxial fusion: A biomechanical analysis of two C1-C2 fusion techniques
-
DOI 10.1016/j.spinee.2006.08.010, PII S1529943006008941
-
Claybrooks R, Kayanja M, Milks R, et al. Atlantoaxial fusion: a biomechanical analysis of two C1-C2 fusion techniques. Spine J. 2007;7:682-688. (Pubitemid 350056419)
-
(2007)
Spine Journal
, vol.7
, Issue.6
, pp. 682-688
-
-
Claybrooks, R.1
Kayanja, M.2
Milks, R.3
Benzel, E.4
-
19
-
-
33745792102
-
Biomechanical comparison of four C1 to C2 rigid fixative techniques: Anterior transarticular, posterior transarticular, C1 to C2 pedicle, and C1 to C2 intralaminar screws
-
discussion 516-521
-
Lapsiwala SB, Anderson PA, Oza A, et al. Biomechanical comparison of four C1 to C2 rigid fixative techniques: anterior transarticular, posterior transarticular, C1 to C2 pedicle, and C1 to C2 intralaminar screws. Neurosurgery. 2006;58:516-21; discussion 516-521.
-
(2006)
Neurosurgery
, vol.58
, pp. 516-521
-
-
Lapsiwala, S.B.1
Anderson, P.A.2
Oza, A.3
-
20
-
-
74249103748
-
Biomechanical evaluation of segmental occipitoatlantoaxial stabilization techniques
-
Nassos JT, Ghanayem AJ, Sasso RC, et al. Biomechanical evaluation of segmental occipitoatlantoaxial stabilization techniques. Spine. 2009;34:2740-2744.
-
(2009)
Spine
, vol.34
, pp. 2740-2744
-
-
Nassos, J.T.1
Ghanayem, A.J.2
Sasso, R.C.3
-
21
-
-
35348906662
-
In vitro biomechanical comparison of transpedicular versus translaminar C-2 screw fixation in C2-3 instrumentation
-
DOI 10.3171/spi.2007.7.4.414
-
Reddy C, Ingalhalikar AV, Channon S, et al. In vitro biomechanical comparison of transpedicular versus translaminar C-2 screw fixation in C2-3 instrumentation. J Neurosurg Spine. 2007;7:414-418. (Pubitemid 47584618)
-
(2007)
Journal of Neurosurgery: Spine
, vol.7
, Issue.4
, pp. 414-418
-
-
Reddy, C.1
Ingalhalikar, A.V.2
Channon, S.3
Lim, T.-H.4
Torner, J.5
Hitchon, P.W.6
-
22
-
-
42449138374
-
Salvage of C2 pedicle and pars screws using the intralaminar technique: A biomechanical analysis
-
DOI 10.1097/BRS.0b013e31816c915b, PII 0000763220080420000006
-
Lehman RA Jr, Dmitriev AE, Helgeson MD, et al. Salvage of C2 pedicle and pars screws using the intralaminar technique: a biomechanical analysis. Spine. 2008;33:960-965. (Pubitemid 351572286)
-
(2008)
Spine
, vol.33
, Issue.9
, pp. 960-965
-
-
Lehman Jr., R.A.1
Dmitriev, A.E.2
Helgeson, M.D.3
Sasso, R.C.4
Kuklo, T.R.5
Riew, K.D.6
-
23
-
-
33751089581
-
Anatomic considerations for the placement of C2 laminar screws
-
DOI 10.1097/01.brs.0000245869.85276.f4, PII 0000763220061115000003
-
Cassinelli EH, Lee M, Skalak A, et al. Anatomic considerations for the placement of C2 laminar screws. Spine. 2006;31:2767-2771. (Pubitemid 44772774)
-
(2006)
Spine
, vol.31
, Issue.24
, pp. 2767-2771
-
-
Cassinelli, E.H.1
Lee, M.2
Skalak, A.3
Ahn, N.U.4
Wright, N.M.5
-
24
-
-
63649085985
-
Correlation between computed tomography measurements and direct anatomic measurements of the axis for consideration of C2 laminar screw placement
-
Dean CL, Lee MJ, Robbin M, et al. Correlation between computed tomography measurements and direct anatomic measurements of the axis for consideration of C2 laminar screw placement. Spine J. 2009;9:258-262.
-
(2009)
Spine J
, vol.9
, pp. 258-262
-
-
Dean, C.L.1
Lee, M.J.2
Robbin, M.3
-
25
-
-
57049152374
-
Computerized tomographic measurements of morphometric parameters of the C2 for the feasibility of laminar screw fixation in Korean population
-
Kim YJ, Rhee WT, Lee SB, et al. Computerized tomographic measurements of morphometric parameters of the C2 for the feasibility of laminar screw fixation in Korean population. J Korean Neurosurg Soc. 2008;44:15-18.
-
(2008)
J Korean Neurosurg Soc
, vol.44
, pp. 15-18
-
-
Kim, Y.J.1
Rhee, W.T.2
Lee, S.B.3
-
26
-
-
41349107389
-
Application of laminar screws to posterior fusion of cervical spine: Measurement of the cervical vertebral arch diameter with a navigation system
-
DOI 10.1097/BRS.0b013e318166aa76, PII 0000763220080315000008
-
Nakanishi K, Tanaka M, Sugimoto Y, et al. Application of laminar screws to posterior fusion of cervical spine: measurement of the cervical vertebral arch diameter with a navigation system. Spine. 2008;33:620-623. (Pubitemid 351451723)
-
(2008)
Spine
, vol.33
, Issue.6
, pp. 620-623
-
-
Nakanishi, K.1
Tanaka, M.2
Sugimoto, Y.3
Misawa, H.4
Takigawa, T.5
Fujiwara, K.6
Nishida, K.7
Ozaki, T.8
-
27
-
-
33745784887
-
C2 crossing laminar screws: Cadaveric morphometric analysis
-
discussion ONS84-8
-
Wang MY. C2 crossing laminar screws: cadaveric morphometric analysis. Neurosurgery. 2006;59(1 Suppl 1):ONS84-ONS8; discussion ONS84-8.
-
(2006)
Neurosurgery
, vol.59
, Issue.1 SUPPL. 1
-
-
Wang, M.Y.1
-
28
-
-
77956893671
-
Pedicle versus laminar screws: What provides more suitable C2 fixation in congenital C2-3 fusion patients?
-
Wang S, Wang C, Passias PG, et al. Pedicle versus laminar screws: what provides more suitable C2 fixation in congenital C2-3 fusion patients? Eur Spine J. 2010;19:1306-1311.
-
(2010)
Eur Spine J
, vol.19
, pp. 1306-1311
-
-
Wang, S.1
Wang, C.2
Passias, P.G.3
-
29
-
-
79954483554
-
C2 translaminar screw as the optimal choice for atlantoaxial dislocation with C2-C3 congenital fusion
-
[Epub ahead of print]
-
Zhou F, Ni B, Li S, et al. C2 translaminar screw as the optimal choice for atlantoaxial dislocation with C2-C3 congenital fusion. Arch Orthop Trauma Surg. 2010. [Epub ahead of print].
-
(2010)
Arch Orthop Trauma Surg
-
-
Zhou, F.1
Ni, B.2
Li, S.3
|