메뉴 건너뛰기




Volumn 19, Issue 8, 2010, Pages 1306-1311

Pedicle versus laminar screws: What provides more suitable C2 fixation in congenital C2-3 fusion patients?

Author keywords

Congenital C2 3 fusion; Klippel Feil; Laminar screw; Occipitocervical fixation; Pedicle screw

Indexed keywords

ADULT; ARTICLE; BONE SCREW; CERVICAL SPINE; COMPUTER ASSISTED TOMOGRAPHY; FEMALE; HUMAN; KLIPPEL FEIL SYNDROME; LAMINAR SCREW; MAJOR CLINICAL STUDY; MALE; PEDICLE SCREW; PRIORITY JOURNAL; SURGICAL APPROACH;

EID: 77956893671     PISSN: 09406719     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00586-010-1418-6     Document Type: Article
Times cited : (25)

References (21)
  • 1
    • 0033565624 scopus 로고    scopus 로고
    • Posterior occipitocervical reconstruction using cervical pedicle screws and plate-rod systems
    • DOI 10.1097/00007632-199907150-00007
    • Abumi K, Takada T, Shono Y, Kaneda K, Fujiya M (1999) Posterior occipitocervical reconstruction using cervical pedicle screws and plate-rod systems. Spine 24:1425-1434 (Pubitemid 29331415)
    • (1999) Spine , vol.24 , Issue.14 , pp. 1425-1434
    • Abumi, K.1    Takada, T.2    Shono, Y.3    Kaneda, K.4    Fujiya, M.5
  • 2
    • 33751089581 scopus 로고    scopus 로고
    • Anatomic considerations for the placement of C2 laminar screws
    • Cassinelli EH, Lee M, Skalak A, Ahn NU, Wright NM (2006) Anatomic considerations for the placement of C2 laminar screws. Spine 31:2767-2771
    • (2006) Spine , vol.31 , pp. 2767-2771
    • Cassinelli, E.H.1    Lee, M.2    Skalak, A.3    Ahn, N.U.4    Wright, N.M.5
  • 3
    • 0029954245 scopus 로고    scopus 로고
    • Patterned expression in familial Klippel-Feil syndrome
    • Clarke RA, Kearsley JH, Walsh DA (1996) Patterned expression in familialKlippel-Feil syndrome. Teratology 53:152-157
    • (1996) Teratology , vol.53 , pp. 152-157
    • Clarke, R.A.1    Kearsley, J.H.2    Walsh, D.A.3
  • 4
    • 63649085985 scopus 로고    scopus 로고
    • Correlation between computed tomography measurements and direct anatomic measurements of the axis for consideration of C2 laminar screw placement
    • Dean CL, Lee MJ, Robbin M, Cassinelli EH (2009) Correlation between computed tomography measurements and direct anatomic measurements of the axis for consideration of C2 laminar screw placement. Spine J 9:258-262
    • (2009) Spine J , vol.9 , pp. 258-262
    • Dean, C.L.1    Lee, M.J.2    Robbin, M.3    Cassinelli, E.H.4
  • 5
    • 0029869526 scopus 로고    scopus 로고
    • Anatomic consideration of C2 pedicle screw placement
    • Ebraheim N, Rollins JR Jr, Xu R, Jackson WT (1996) Anatomic consideration of C2 pedicle screw placement. Spine 21:691-695
    • (1996) Spine , vol.21 , pp. 691-695
    • Ebraheim, N.1    Rollins Jr., J.R.2    Xu, R.3    Jackson, W.T.4
  • 6
    • 55249125685 scopus 로고    scopus 로고
    • The cervical end of an occipitocervical fusion: A biomechanical evaluation of 3 constructs. Laboratory investigation
    • Finn MA, Fassett DR, Mccall TD, Clark R, Dailey AT, Brodke DS (2008) The cervical end of an occipitocervical fusion: a biomechanical evaluation of 3 constructs. Laboratory investigation. J Neurosurg Spine 9:296-300
    • (2008) J Neurosurg Spine , vol.9 , pp. 296-300
    • Finn, M.A.1    Fassett, D.R.2    McCall, T.D.3    Clark, R.4    Dailey, A.T.5    Brodke, D.S.6
  • 7
    • 22144451090 scopus 로고    scopus 로고
    • Constructs incorporating intralaminar C2 screws provide rigid stability for atlantoaxial fixation
    • Gorek J, Acaroglu E, Berven S, Yousef A, Puttlitz CM (2005) Constructs incorporating intralaminar C2 screws provide rigid stability for atlantoaxial fixation. Spine 30:1513-1518
    • (2005) Spine , vol.30 , pp. 1513-1518
    • Gorek, J.1    Acaroglu, E.2    Berven, S.3    Yousef, A.4    Puttlitz, C.M.5
  • 8
    • 0035890208 scopus 로고    scopus 로고
    • Posterior C1-2 fusion with poly-axial screw and rod fixation
    • Harms J, Melcher RP (2001) Posterior C1-2 fusion with poly- axial screw and rod fixation. Spine 26:2467-2471
    • (2001) Spine , vol.26 , pp. 2467-2471
    • Harms, J.1    Melcher, R.P.2
  • 10
    • 33745792102 scopus 로고    scopus 로고
    • Biomechanical comparison of four C1 to C2 rigid fixative techniques: Anterior transarticular, posterior transarticular, C1 to C2 pedicle, and C1 to C2 intralaminar screws
    • Lapsiwala SB, Anderson PA, Oza A, Resnick DK (2006) Biomechanical comparison of four C1 to C2 rigid fixative techniques: anterior transarticular, posterior transarticular, C1 to C2 pedicle, and C1 to C2 intralaminar screws. Neurosurgery 58:516-521
    • (2006) Neurosurgery , vol.58 , pp. 516-521
    • Lapsiwala, S.B.1    Anderson, P.A.2    Oza, A.3    Resnick, D.K.4
  • 12
    • 0026040571 scopus 로고
    • Cervical human vertebrae. Quantitative three-dimensional anatomy of the middle and lower regions
    • Panjabi MM, Duranceau J, Goel V, Oxland T, Takata K (1991) Cervical human vertebrae. Quantitative three-dimensional anatomy of the middle and lower regions. Spine 16:861-869
    • (1991) Spine , vol.16 , pp. 861-869
    • Panjabi, M.M.1    Duranceau, J.2    Goel, V.3    Oxland, T.4    Takata, K.5
  • 13
    • 0037099510 scopus 로고    scopus 로고
    • Anatomic suitability of the C1-C2 complex for pedicle screw fixation
    • Resnick DK, Lapsiwala S, Trost GR (2002) Anatomic suitability of the C1-C2 complex for pedicle screw fixation. Spine 27:1494-1498
    • (2002) Spine , vol.27 , pp. 1494-1498
    • Resnick, D.K.1    Lapsiwala, S.2    Trost, G.R.3
  • 14
    • 0037102598 scopus 로고    scopus 로고
    • Posterior atlantoaxial fixation: Biomechanical in vitro comparison of six different techniques
    • Richter M, Schmidt R, Claes L, Puhl W, Wilke HJ (2002) Posterior atlantoaxial fixation: biomechanical in vitro comparison of six different techniques. Spine 27:1724-1732
    • (2002) Spine , vol.27 , pp. 1724-1732
    • Richter, M.1    Schmidt, R.2    Claes, L.3    Puhl, W.4    Wilke, H.J.5
  • 15
    • 50949124647 scopus 로고    scopus 로고
    • The extent of fusion within the congenital Klippel-Feil segment
    • Samartzis D, Kalluri P, Herman J, Lubicky JP, Shen FH (2008) The extent of fusion within the congenital Klippel-Feil segment. Spine 33:1637-1642
    • (2008) Spine , vol.33 , pp. 1637-1642
    • Samartzis, D.1    Kalluri, P.2    Herman, J.3    Lubicky, J.P.4    Shen, F.H.5
  • 16
    • 30944459056 scopus 로고    scopus 로고
    • Radio-graphic assessment of segmental motion at the atlantoaxial junction in the Klippel-Feil patient
    • Shen FH, Samartzis D, Herman J, Lubicky JP (2006) Radio-graphic assessment of segmental motion at the atlantoaxial junction in the Klippel-Feil patient. Spine 31:171-177
    • (2006) Spine , vol.31 , pp. 171-177
    • Shen, F.H.1    Samartzis, D.2    Herman, J.3    Lubicky, J.P.4
  • 17
    • 3042740450 scopus 로고    scopus 로고
    • Klippel-Feil syndrome: Clinical features and current understanding of etiology
    • Tracy MR, Dormans JP, Kusumi K (2004) Klippel-Feil syndrome: clinical features and current understanding of etiology. Clin Orthop Relat Res 424:183-190
    • (2004) Clin Orthop Relat Res , vol.424 , pp. 183-190
    • Tracy, M.R.1    Dormans, J.P.2    Kusumi, K.3
  • 18
    • 33745784887 scopus 로고    scopus 로고
    • C2 crossing laminar screws: Cadaveric mor-phometric analysis
    • ONS
    • Wang MY (2006) C2 crossing laminar screws: cadaveric mor-phometric analysis. Neurosurgery 59:ONS 84-88
    • (2006) Neurosurgery , vol.59 , pp. 84-88
    • Wang, M.Y.1
  • 19
    • 1842686189 scopus 로고    scopus 로고
    • Posterior C2 fixation using bilateral, crossing C2 laminar screws: Case series and technical note
    • Wright NM (2004) Posterior C2 fixation using bilateral, crossing C2 laminar screws: case series and technical note. J Spinal Disord Tech 17:158-162
    • (2004) J Spinal Disord Tech , vol.17 , pp. 158-162
    • Wright, N.M.1
  • 20
    • 68549122780 scopus 로고    scopus 로고
    • Undetected vertebral artery groove and foramen violations during C1 lateral mass and C2 pedicle screw placement
    • Yeom JS, Buchowski JM, Park KW, Chang BS, Lee CK, Riew KD (2008) Undetected vertebral artery groove and foramen violations during C1 lateral mass and C2 pedicle screw placement. Spine 33:E942-E949
    • (2008) Spine , vol.33
    • Yeom, J.S.1    Buchowski, J.M.2    Park, K.W.3    Chang, B.S.4    Lee, C.K.5    Riew, K.D.6
  • 21
    • 33745712021 scopus 로고    scopus 로고
    • Comparison of the anatomical risk for vertebral artery injury associated with the C2-pedicle screw and atlantoaxial transarticular screw
    • Yoshida M, Neo M, Fujibayashi S, Nakamura T (2006) Comparison of the anatomical risk for vertebral artery injury associated with the C2-pedicle screw and atlantoaxial transarticular screw. Spine 31:E513-E517
    • (2006) Spine , vol.31
    • Yoshida, M.1    Neo, M.2    Fujibayashi, S.3    Nakamura, T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.