메뉴 건너뛰기




Volumn 13, Issue 1, 2011, Pages 52-57

Continuous cardiac output monitoring with an uncalibrated pulse contour method in patients supported with mechanical pulsatile assist device

Author keywords

Cardiac output; Heart failure; Pulse contour analysis; Thermodilution technique; Ventricular assist device

Indexed keywords

ADULT; ANALYTICAL ERROR; ARTERY CATHETERIZATION; ARTICLE; CLINICAL ARTICLE; CLINICAL ASSESSMENT TOOL; CLINICAL EVALUATION; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; HEART OUTPUT MEASUREMENT; HEMODYNAMIC MONITORING; HUMAN; INTERMETHOD COMPARISON; LEFT VENTRICULAR ASSIST DEVICE; PERIPHERAL CIRCULATION; PRESSURE RECORDING ANALYTICAL METHOD; PRIORITY JOURNAL; PULSATILE FLOW; PULSE WAVE; RELIABILITY; SENSITIVITY AND SPECIFICITY; THERMODILUTION;

EID: 79959664305     PISSN: 15699293     EISSN: 15699285     Source Type: Journal    
DOI: 10.1510/icvts.2010.264234     Document Type: Article
Times cited : (17)

References (15)
  • 2
    • 67349185641 scopus 로고    scopus 로고
    • Assessment of arterial blood pressure during support with an axial flow left ventricular assist device
    • Myers TJ, Bolmers M, Gregoric ID, Kar B, Frazier OH. Assessment of arterial blood pressure during support with an axial flow left ventricular assist device. J Heart Lung Transplant 2009;28:423-427.
    • (2009) J Heart Lung Transplant , vol.28 , pp. 423-427
    • Myers, T.J.1    Bolmers, M.2    Gregoric, I.D.3    Kar, B.4    Frazier, O.H.5
  • 3
    • 0032547931 scopus 로고    scopus 로고
    • Implantable left ventricular assist devices
    • Goldstein D, Oz M, Rose E. Implantable left ventricular assist devices. N Engl J Med 1998;339:1522-1533.
    • (1998) N Engl J Med , vol.339 , pp. 1522-1533
    • Goldstein, D.1    Oz, M.2    Rose, E.3
  • 4
    • 34347398471 scopus 로고    scopus 로고
    • Pulse wave analysis to assess systemic blood flow during mechanical biven-tricular support
    • Scolletta S, Gregoric ID, Muzzi L, Radovancevic B, Frazier OH. Pulse wave analysis to assess systemic blood flow during mechanical biven-tricular support. Perfusion 2007;22:63-66.
    • (2007) Perfusion , vol.22 , pp. 63-66
    • Scolletta, S.1    Gregoric, I.D.2    Muzzi, L.3    Radovancevic, B.4    Frazier, O.H.5
  • 5
    • 0029016594 scopus 로고
    • Evaluation of a new continuous thermodilution cardiac output monitor in critically ill patients: A prospective criterion standard study
    • Haller M, Zöllner C, Briegel J, Forst H. Evaluation of a new continuous thermodilution cardiac output monitor in critically ill patients: a prospective criterion standard study. Crit Care Med 1995;23:860-866.
    • (1995) Crit Care Med , vol.23 , pp. 860-866
    • Haller, M.1    Zöllner, C.2    Briegel, J.3    Forst, H.4
  • 6
    • 0036946046 scopus 로고    scopus 로고
    • Validation of continuous thermodilution cardiac output in patients implanted with a left ventricular assist device
    • Mets B, Frumento RJ, Bennett-Guerrero E, Naka Y. Validation of continuous thermodilution cardiac output in patients implanted with a left ventricular assist device. J Cardiothorac Vasc Anesth 2002;16:727-730.
    • (2002) J Cardiothorac Vasc Anesth , vol.16 , pp. 727-730
    • Mets, B.1    Frumento, R.J.2    Bennett-Guerrero, E.3    Naka, Y.4
  • 7
    • 1642389930 scopus 로고    scopus 로고
    • Assessment of left ventricular cardiac output by arterial thermodilution technique via a left atrial catheter in a patient on a right ventricular assist device
    • Wiesenack C, Prasser C, Liebold A, Schmid FX. Assessment of left ventricular cardiac output by arterial thermodilution technique via a left atrial catheter in a patient on a right ventricular assist device. Perfusion 2004;19:73-75.
    • (2004) Perfusion , vol.19 , pp. 73-75
    • Wiesenack, C.1    Prasser, C.2    Liebold, A.3    Schmid, F.X.4
  • 8
    • 70449475939 scopus 로고    scopus 로고
    • Cardiac output derived from arterial pressure waveform
    • Mayer J, Suttner S. Cardiac output derived from arterial pressure waveform. Curr Opin Anaesthesiol 2009;22:804-808.
    • (2009) Curr Opin Anaesthesiol , vol.22 , pp. 804-808
    • Mayer, J.1    Suttner, S.2
  • 9
    • 0036342701 scopus 로고    scopus 로고
    • Assessment of cardiac output from systemic arterial pressure in humans
    • Romano SM, Pistolesi M. Assessment of cardiac output from systemic arterial pressure in humans. Crit Care Med 2002;30:1834-1841.
    • (2002) Crit Care Med , vol.30 , pp. 1834-1841
    • Romano, S.M.1    Pistolesi, M.2
  • 10
    • 4143134234 scopus 로고    scopus 로고
    • Cardiac output monitoring by pressure recording analytical method in cardiac surgery
    • Giomarelli P, Biagioli B, Scolletta S. Cardiac output monitoring by pressure recording analytical method in cardiac surgery. Eur J Cardi-othorac Surg 2004;26:515-520.
    • (2004) Eur J Cardi-othorac Surg , vol.26 , pp. 515-520
    • Giomarelli, P.1    Biagioli, B.2    Scolletta, S.3
  • 11
    • 23844520689 scopus 로고    scopus 로고
    • Pressure recording analytical method (PRAM) for measurement of cardiac output during various haemodynamic states
    • Scolletta S, Romano SM, Biagioli B, Capannini G, Giomarelli P. Pressure recording analytical method (PRAM) for measurement of cardiac output during various haemodynamic states. Br J Anaesth 2005;95:159-165.
    • (2005) Br J Anaesth , vol.95 , pp. 159-165
    • Scolletta, S.1    Romano, S.M.2    Biagioli, B.3    Capannini, G.4    Giomarelli, P.5
  • 12
    • 43549100903 scopus 로고    scopus 로고
    • Assessment of cardiac output in children: A comparison between the pressure recording analytical method and Doppler echo-cardiography
    • Calamandrei M, Mirabile L, Muschetta S, Gensini GF, De Simone L, Romano SM. Assessment of cardiac output in children: a comparison between the pressure recording analytical method and Doppler echo-cardiography. Pediatr Crit Care Med 2008;9:310-312.
    • (2008) Pediatr Crit Care Med , vol.9 , pp. 310-312
    • Calamandrei, M.1    Mirabile, L.2    Muschetta, S.3    Gensini, G.F.4    de Simone, L.5    Romano, S.M.6
  • 14
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 15
    • 0033003166 scopus 로고    scopus 로고
    • A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    • Critchley LAH, Critchley JAJH. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monitor 1999;15:85-91.
    • (1999) J Clin Monitor , vol.15 , pp. 85-91
    • Critchley, L.A.H.1    Critchley, J.A.J.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.