메뉴 건너뛰기




Volumn 38, Issue 5, 2013, Pages 1033-1042

Application of time-resolved angiography with stochastic trajectories (twist)-dixon in dynamic contrast-enhanced (dce) breast mri

Author keywords

breast MRI; Dixon; dynamic contrast enhancement; fat suppression; TWIST; view sharing

Indexed keywords

ACCURACY; ANGIOGRAPHY; ARTICLE; BREAST; CLINICAL ARTICLE; FOURIER TRANSFORMATION; HUMAN; IMAGE QUALITY; IMAGING PHANTOM; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; RADIOLOGICAL PARAMETERS; SIGNAL NOISE RATIO; SIMULATION; SUSCEPTIBILITY WEIGHTED IMAGING; TIME RESOLVED ANGIOGRAPHY WITH STOCHASTIC TRAJECTORIES; TUMOR VOLUME;

EID: 84886948080     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.24062     Document Type: Article
Times cited : (29)

References (26)
  • 1
    • 84886951788 scopus 로고    scopus 로고
    • Centers for Disease Control and Prevention
    • Centers for Disease Control and Prevention. http://www.cdc.gov/cancer/ breast/statistics/ 2011.
    • (2011)
  • 2
    • 34249069377 scopus 로고    scopus 로고
    • Patterns of enhancement on breast MR images: Interpretation and imaging pitfalls
    • quiz 1719
    • Macura KJ, Ouwerkerk R, Jacobs MA, Bluemke DA,. Patterns of enhancement on breast MR images: interpretation and imaging pitfalls. Radiographics 2006; 26: 1719-1734; quiz 1719.
    • (2006) Radiographics , vol.26 , pp. 1719-1734
    • Macura, K.J.1    Ouwerkerk, R.2    Jacobs, M.A.3    Bluemke, D.A.4
  • 3
    • 79959544192 scopus 로고    scopus 로고
    • Use of dynamic contrast-enhanced MR imaging to predict survival in patients with primary breast cancer undergoing neoadjuvant chemotherapy
    • Li SP, Makris A, Beresford MJ, etal. Use of dynamic contrast-enhanced MR imaging to predict survival in patients with primary breast cancer undergoing neoadjuvant chemotherapy. Radiology 2011; 260: 68-78.
    • (2011) Radiology , vol.260 , pp. 68-78
    • Li, S.P.1    Makris, A.2    Beresford, M.J.3
  • 4
    • 29444442413 scopus 로고    scopus 로고
    • Diagnostic architectural and dynamic features at breast MR imaging: Multicenter study
    • Schnall MD, Blume J, Bluemke DA, et al. Diagnostic architectural and dynamic features at breast MR imaging: multicenter study. Radiology 2006; 238: 42-53.
    • (2006) Radiology , vol.238 , pp. 42-53
    • Schnall, M.D.1    Blume, J.2    Bluemke, D.A.3
  • 5
    • 34447508128 scopus 로고    scopus 로고
    • The current status of breast MR imaging. Part I. Choice of technique, image interpretation, diagnostic accuracy, and transfer to clinical practice
    • Kuhl C,. The current status of breast MR imaging. Part I. Choice of technique, image interpretation, diagnostic accuracy, and transfer to clinical practice. Radiology 2007; 244: 356-378.
    • (2007) Radiology , vol.244 , pp. 356-378
    • Kuhl, C.1
  • 7
    • 42549135002 scopus 로고    scopus 로고
    • Fat suppression for 1H MRSI at 7T using spectrally selective adiabatic inversion recovery
    • Balchandani P, Spielman D,. Fat suppression for 1H MRSI at 7T using spectrally selective adiabatic inversion recovery. Magn Reson Med 2008; 59: 980-988.
    • (2008) Magn Reson Med , vol.59 , pp. 980-988
    • Balchandani, P.1    Spielman, D.2
  • 8
    • 0021132985 scopus 로고
    • Simple proton spectroscopic imaging
    • Dixon WT,. Simple proton spectroscopic imaging. Radiology 1984; 153: 189-194.
    • (1984) Radiology , vol.153 , pp. 189-194
    • Dixon, W.T.1
  • 9
    • 65249156554 scopus 로고    scopus 로고
    • Optimal k-space sampling for dynamic contrast-enhanced MRI with an application to MR renography
    • Song T, Laine AF, Chen Q, et al. Optimal k-space sampling for dynamic contrast-enhanced MRI with an application to MR renography. Magn Reson Med 2009; 61: 1242-1248.
    • (2009) Magn Reson Med , vol.61 , pp. 1242-1248
    • Song, T.1    Laine, A.F.2    Chen, Q.3
  • 10
    • 84862109766 scopus 로고    scopus 로고
    • DIfferential subsampling with Cartesian ordering (DISCO): A high spatio-temporal resolution Dixon imaging sequence for multiphasic contrast enhanced abdominal imaging
    • Saranathan M, Rettmann DW, Hargreaves BA, Clarke SE, Vasanawala SS,. DIfferential subsampling with Cartesian ordering (DISCO): a high spatio-temporal resolution Dixon imaging sequence for multiphasic contrast enhanced abdominal imaging. J Magn Reson Imaging 2012; 35: 1484-1492.
    • (2012) J Magn Reson Imaging , vol.35 , pp. 1484-1492
    • Saranathan, M.1    Rettmann, D.W.2    Hargreaves, B.A.3    Clarke, S.E.4    Vasanawala, S.S.5
  • 11
    • 66749134616 scopus 로고    scopus 로고
    • Multiecho time-resolved acquisition (META): A high spatiotemporal resolution Dixon imaging sequence for dynamic contrast-enhanced MRI
    • Saranathan M, Rettmann D, Bayram E, Lee C, Glockner J,. Multiecho time-resolved acquisition (META): a high spatiotemporal resolution Dixon imaging sequence for dynamic contrast-enhanced MRI. J Magn Reson Imaging 2009; 29: 1406-1413.
    • (2009) J Magn Reson Imaging , vol.29 , pp. 1406-1413
    • Saranathan, M.1    Rettmann, D.2    Bayram, E.3    Lee, C.4    Glockner, J.5
  • 12
    • 77958123740 scopus 로고    scopus 로고
    • Three-dimensional multiphase time-resolved low-dose contrast-enhanced magnetic resonance angiography using TWIST on a 32-channel coil at 3 T: A quantitative and qualitative comparison of a conventional gadolinium chelate with a high-relaxivity agent
    • Giesel FL, Runge V, Kirchin M, et al. Three-dimensional multiphase time-resolved low-dose contrast-enhanced magnetic resonance angiography using TWIST on a 32-channel coil at 3 T: a quantitative and qualitative comparison of a conventional gadolinium chelate with a high-relaxivity agent. J Comput Assist Tomogr 2010; 34: 678-683.
    • (2010) J Comput Assist Tomogr , vol.34 , pp. 678-683
    • Giesel, F.L.1    Runge, V.2    Kirchin, M.3
  • 13
    • 84864228220 scopus 로고    scopus 로고
    • Development and evaluation of TWIST Dixon for dynamic contrast-enhanced (DCE) MRI with improved acquisition efficiency and fat suppression
    • Le Y, Kroeker R, Kipfer HD, Lin C,. Development and evaluation of TWIST Dixon for dynamic contrast-enhanced (DCE) MRI with improved acquisition efficiency and fat suppression. J Magn Reson Imaging 2012; 36: 483-491.
    • (2012) J Magn Reson Imaging , vol.36 , pp. 483-491
    • Le, Y.1    Kroeker, R.2    Kipfer, H.D.3    Lin, C.4
  • 14
    • 84867140551 scopus 로고    scopus 로고
    • A feasible high spatiotemporal resolution breast DCE-MRI protocol for clinical settings
    • Tudorica LA, Oh KY, Roy N, etal. A feasible high spatiotemporal resolution breast DCE-MRI protocol for clinical settings. Magn Reson Imaging 2012; 30: 1257-1267.
    • (2012) Magn Reson Imaging , vol.30 , pp. 1257-1267
    • Tudorica, L.A.1    Oh, K.Y.2    Roy, N.3
  • 18
    • 0031421868 scopus 로고    scopus 로고
    • Limitations of the keyhole technique for quantitative dynamic contrast-enhanced breast MRI
    • Bishop JE, Santyr GE, Kelcz F, Plewes DB,. Limitations of the keyhole technique for quantitative dynamic contrast-enhanced breast MRI. J Magn Reson Imaging 1997; 7: 716-723.
    • (1997) J Magn Reson Imaging , vol.7 , pp. 716-723
    • Bishop, J.E.1    Santyr, G.E.2    Kelcz, F.3    Plewes, D.B.4
  • 19
    • 3042831904 scopus 로고    scopus 로고
    • Spatio-temporal bandwidth-based acquisition for dynamic contrast-enhanced magnetic resonance imaging
    • Krishnan S, Chenevert TL,. Spatio-temporal bandwidth-based acquisition for dynamic contrast-enhanced magnetic resonance imaging. J Magn Reson Imaging 2004; 20: 129-137.
    • (2004) J Magn Reson Imaging , vol.20 , pp. 129-137
    • Krishnan, S.1    Chenevert, T.L.2
  • 20
    • 0034051586 scopus 로고    scopus 로고
    • Benefits and pitfalls of keyhole imaging, especially in first-pass perfusion studies
    • Oesterle C, Strohschein R, Kohler M, Schnell M, Hennig J,. Benefits and pitfalls of keyhole imaging, especially in first-pass perfusion studies. J Magn Reson Imaging 2000; 11: 312-323.
    • (2000) J Magn Reson Imaging , vol.11 , pp. 312-323
    • Oesterle, C.1    Strohschein, R.2    Kohler, M.3    Schnell, M.4    Hennig, J.5
  • 21
    • 0034772629 scopus 로고    scopus 로고
    • Magnetic resonance imaging of the lung with a volumetric interpolated 3D-gradient echo sequence
    • Biederer J, Graessner J, Heller M,. Magnetic resonance imaging of the lung with a volumetric interpolated 3D-gradient echo sequence. Rofo-Fortschr Rontg 2001; 173: 883-887.
    • (2001) Rofo-Fortschr Rontg , vol.173 , pp. 883-887
    • Biederer, J.1    Graessner, J.2    Heller, M.3
  • 22
    • 0036084020 scopus 로고    scopus 로고
    • VIBE with parallel acquisition technique - A novel approach to dynamic contrast-enhanced MR imaging of the liver
    • Dobritz M, Radkow T, Nittka M, Bautz W, Fellner FA,. VIBE with parallel acquisition technique-a novel approach to dynamic contrast-enhanced MR imaging of the liver. Rofo-Fortschr Rontg 2002; 174: 738-741.
    • (2002) Rofo-Fortschr Rontg , vol.174 , pp. 738-741
    • Dobritz, M.1    Radkow, T.2    Nittka, M.3    Bautz, W.4    Fellner, F.A.5
  • 23
    • 0032882776 scopus 로고    scopus 로고
    • Abdominal MR imaging with a volumetric interpolated breath-hold examination
    • Rofsky NM, Lee VS, Laub G, et al. Abdominal MR imaging with a volumetric interpolated breath-hold examination. Radiology 1999; 212: 876-884.
    • (1999) Radiology , vol.212 , pp. 876-884
    • Rofsky, N.M.1    Lee, V.S.2    Laub, G.3
  • 24
    • 63449120748 scopus 로고    scopus 로고
    • Significance of breast lesion descriptors in the ACR BI-RADS MRI lexicon
    • Agrawal G, Su MY, Nalcioglu O, Feig SA, Chen JH,. Significance of breast lesion descriptors in the ACR BI-RADS MRI lexicon. Cancer 2009; 115: 1363-1380.
    • (2009) Cancer , vol.115 , pp. 1363-1380
    • Agrawal, G.1    Su, M.Y.2    Nalcioglu, O.3    Feig, S.A.4    Chen, J.H.5
  • 25
    • 28044467524 scopus 로고    scopus 로고
    • Magnetic resonance imaging of the body trunk using a single-slab, 3-dimensional, T2-weighted turbo-spin-echo sequence with high sampling efficiency (SPACE) for high spatial resolution imaging: Initial clinical experiences
    • Lichy MP, Wietek BM, Mugler JP 3rd, et al. Magnetic resonance imaging of the body trunk using a single-slab, 3-dimensional, T2-weighted turbo-spin-echo sequence with high sampling efficiency (SPACE) for high spatial resolution imaging: initial clinical experiences. Invest Radiol 2005; 40: 754-760.
    • (2005) Invest Radiol , vol.40 , pp. 754-760
    • Lichy, M.P.1    Wietek, B.M.2    Mugler III, J.P.3
  • 26
    • 34249891603 scopus 로고    scopus 로고
    • Comparison of biphasic and reordered fat suppression for dynamic breast MRI
    • Desmond KL, Ramsay EA, Plewes DB,. Comparison of biphasic and reordered fat suppression for dynamic breast MRI. J Magn Reson Imaging 2007; 25: 1293-1298.
    • (2007) J Magn Reson Imaging , vol.25 , pp. 1293-1298
    • Desmond, K.L.1    Ramsay, E.A.2    Plewes, D.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.