메뉴 건너뛰기




Volumn 70, Issue 3, 2013, Pages 648-656

Magnetic susceptibility as a B0 field strength independent MRI biomarker of liver iron overload

Author keywords

chemical shift encoded imaging; field map; iron overload; liver; magnetic resonance imaging; susceptibility

Indexed keywords

CHEMICAL SHIFT; CONVOLUTION; LIVER; MAGNETIC RESONANCE IMAGING; MAGNETIC SUSCEPTIBILITY; MAGNETISM; MAPPING; PHANTOMS; TISSUE;

EID: 84883253342     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.24848     Document Type: Article
Times cited : (37)

References (56)
  • 2
    • 0029919699 scopus 로고    scopus 로고
    • Abdominal iron deposition: Metabolism, MR findings, and clinical importance
    • Siegelman ES, Mitchell DG, Semelka RC,. Abdominal iron deposition: metabolism, MR findings, and clinical importance. Radiology 1996; 199: 13-22.
    • (1996) Radiology , vol.199 , pp. 13-22
    • Siegelman, E.S.1    Mitchell, D.G.2    Semelka, R.C.3
  • 3
    • 0031001278 scopus 로고    scopus 로고
    • Iron-chelating therapy and the treatment of thalassemia
    • Olivieri NF, Brittenham GM,. Iron-chelating therapy and the treatment of thalassemia. Blood 1997; 89: 739-761.
    • (1997) Blood , vol.89 , pp. 739-761
    • Olivieri, N.F.1    Brittenham, G.M.2
  • 5
    • 65449124273 scopus 로고    scopus 로고
    • Deferasirox for the treatment of iron overload associated with regular blood transfusions (transfusional haemosiderosis) in patients suffering with chronic anaemia: A systematic review and economic evaluation
    • McLeod C, Fleeman N, Kirkham J, et al. Deferasirox for the treatment of iron overload associated with regular blood transfusions (transfusional haemosiderosis) in patients suffering with chronic anaemia: a systematic review and economic evaluation. Health Technol Assess 2009; 13:iii-iv, ix-xi, 1-121.
    • (2009) Health Technol Assess , vol.13 , pp. 1-121
    • McLeod, C.1    Fleeman, N.2    Kirkham, J.3
  • 6
    • 0015228412 scopus 로고
    • Measurement of liver-iron concentration in needle-biopsy specimens
    • Barry M, Sherlock S,. Measurement of liver-iron concentration in needle-biopsy specimens. Lancet 1971; 1: 100-103.
    • (1971) Lancet , vol.1 , pp. 100-103
    • Barry, M.1    Sherlock, S.2
  • 7
    • 0036853763 scopus 로고    scopus 로고
    • Theoretical evaluation of the susceptometric measurement of iron in human liver by four different susceptometers
    • Carneiro AA, Baffa O, Fernandes JP, Zago MA,. Theoretical evaluation of the susceptometric measurement of iron in human liver by four different susceptometers. Physiol Meas 2002; 23: 683-693.
    • (2002) Physiol Meas , vol.23 , pp. 683-693
    • Carneiro, A.A.1    Baffa, O.2    Fernandes, J.P.3    Zago, M.A.4
  • 8
    • 0037217987 scopus 로고    scopus 로고
    • Noninvasive measurement of iron: Report of an NIDDK workshop
    • Brittenham GM, Badman DG,. Noninvasive measurement of iron: report of an NIDDK workshop. Blood 2003; 101: 15-19.
    • (2003) Blood , vol.101 , pp. 15-19
    • Brittenham, G.M.1    Badman, D.G.2
  • 9
    • 0029021768 scopus 로고
    • Extremely elevated serum ferritin levels in a university hospital: Associated diseases and clinical significance
    • Lee MH, Means RT Jr,. Extremely elevated serum ferritin levels in a university hospital: associated diseases and clinical significance. Am J Med 1995; 98: 566-571.
    • (1995) Am J Med , vol.98 , pp. 566-571
    • Lee, M.H.1    Means, Jr.R.T.2
  • 11
    • 0030013529 scopus 로고    scopus 로고
    • The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds
    • Schenck JF,. The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds. Med Phys 1996; 23: 815-850.
    • (1996) Med Phys , vol.23 , pp. 815-850
    • Schenck, J.F.1
  • 12
    • 0014143045 scopus 로고
    • Magnetic susceptibility meter for in vivo estimation of hepatic iron stores
    • Bauman JH, Hoffman RW,. Magnetic susceptibility meter for in vivo estimation of hepatic iron stores. IEEE Trans Biomed Eng 1967; 14: 239-243.
    • (1967) IEEE Trans Biomed Eng , vol.14 , pp. 239-243
    • Bauman, J.H.1    Hoffman, R.W.2
  • 13
    • 0014115713 scopus 로고
    • Estimation of hepatic iron stores by vivo measurement of magnetic susceptibility
    • Bauman JH, Harris JW,. Estimation of hepatic iron stores by vivo measurement of magnetic susceptibility. J Lab Clin Med 1967; 70: 246-257.
    • (1967) J Lab Clin Med , vol.70 , pp. 246-257
    • Bauman, J.H.1    Harris, J.W.2
  • 14
    • 0026122585 scopus 로고
    • Biomagnetic susceptometer with SQUID instrumentation
    • Paulson DN, Fagaly RL, Toussaint RM,. Biomagnetic susceptometer with SQUID instrumentation. IEEE Trans Magn 1991; 27: 3249-3252.
    • (1991) IEEE Trans Magn , vol.27 , pp. 3249-3252
    • Paulson, D.N.1    Fagaly, R.L.2    Toussaint, R.M.3
  • 15
    • 0038542268 scopus 로고    scopus 로고
    • SQUID biosusceptometry in the measurement of hepatic iron
    • Sheth S,. SQUID biosusceptometry in the measurement of hepatic iron. Pediatr Radiol 2003; 33: 373-377.
    • (2003) Pediatr Radiol , vol.33 , pp. 373-377
    • Sheth, S.1
  • 16
    • 53549101684 scopus 로고    scopus 로고
    • Quantitative MR susceptibility mapping using piece-wise constant regularized inversion of the magnetic field
    • de Rochefort L, Brown R, Prince MR, Wang Y,. Quantitative MR susceptibility mapping using piece-wise constant regularized inversion of the magnetic field. Magn Reson Med 2008; 60: 1003-1009.
    • (2008) Magn Reson Med , vol.60 , pp. 1003-1009
    • De Rochefort, L.1    Brown, R.2    Prince, M.R.3    Wang, Y.4
  • 17
    • 84863522265 scopus 로고    scopus 로고
    • Quantitative susceptibility mapping (QSM) as a means to measure brain iron? A post mortem validation study
    • Langkammer C, Schweser F, Krebs N, et al. Quantitative susceptibility mapping (QSM) as a means to measure brain iron? A post mortem validation study. Neuroimage 2012; 62: 1593-1599.
    • (2012) Neuroimage , vol.62 , pp. 1593-1599
    • Langkammer, C.1    Schweser, F.2    Krebs, N.3
  • 18
    • 84859790450 scopus 로고    scopus 로고
    • Simultaneous field and R2* mapping to quantify liver iron content using autoregressive moving average modeling
    • [published erratum appears in J Magn Reson Imaging, early view 2013;37:1254-1255
    • Taylor BA, Loeffler RB, Song R, McCarville MB, Hankins JS, Hillenbrand CM,. Simultaneous field and R2* mapping to quantify liver iron content using autoregressive moving average modeling. J Magn Reson Imaging 2012; 35: 1125-1132 [published erratum appears in J Magn Reson Imaging, early view 2013;37:1254-1255.
    • (2012) J Magn Reson Imaging , vol.35 , pp. 1125-1132
    • Taylor, B.A.1    Loeffler, R.B.2    Song, R.3    McCarville, M.B.4    Hankins, J.S.5    Hillenbrand, C.M.6
  • 20
    • 9244220587 scopus 로고    scopus 로고
    • Single spin-echo proton transverse relaxometry of iron-loaded liver
    • St Pierre TG, Clark PR, Chua-Anusorn W,. Single spin-echo proton transverse relaxometry of iron-loaded liver. NMR Biomed 2004; 17: 446-458.
    • (2004) NMR Biomed , vol.17 , pp. 446-458
    • St Pierre, T.G.1    Clark, P.R.2    Chua-Anusorn, W.3
  • 22
    • 39349091613 scopus 로고    scopus 로고
    • Magnetic resonance imaging assessment of excess iron in thalassemia, sickle cell disease and other iron overload diseases
    • Wood JC, Ghugre N,. Magnetic resonance imaging assessment of excess iron in thalassemia, sickle cell disease and other iron overload diseases. Hemoglobin 2008; 32: 85-96.
    • (2008) Hemoglobin , vol.32 , pp. 85-96
    • Wood, J.C.1    Ghugre, N.2
  • 23
    • 23744459788 scopus 로고    scopus 로고
    • MRI R2 and R2* mapping accurately estimates hepatic iron concentration in transfusion-dependent thalassemia and sickle cell disease patients
    • Wood JC, Enriquez C, Ghugre N, Tyzka JM, Carson S, Nelson MD, Coates TD,. MRI R2 and R2* mapping accurately estimates hepatic iron concentration in transfusion-dependent thalassemia and sickle cell disease patients. Blood 2005; 106: 1460-1465.
    • (2005) Blood , vol.106 , pp. 1460-1465
    • Wood, J.C.1    Enriquez, C.2    Ghugre, N.3    Tyzka, J.M.4    Carson, S.5    Nelson, M.D.6    Coates, T.D.7
  • 24
    • 34247159083 scopus 로고    scopus 로고
    • Magnetic resonance imaging measurement of iron overload
    • Wood JC,. Magnetic resonance imaging measurement of iron overload. Curr Opin Hematol 2007; 14: 183-190.
    • (2007) Curr Opin Hematol , vol.14 , pp. 183-190
    • Wood, J.C.1
  • 25
    • 27644555993 scopus 로고    scopus 로고
    • Mechanisms of tissue-iron relaxivity: Nuclear magnetic resonance studies of human liver biopsy specimens
    • Ghugre NR, Coates TD, Nelson MD, Wood JC,. Mechanisms of tissue-iron relaxivity: nuclear magnetic resonance studies of human liver biopsy specimens. Magn Reson Med 2005; 54: 1185-1193.
    • (2005) Magn Reson Med , vol.54 , pp. 1185-1193
    • Ghugre, N.R.1    Coates, T.D.2    Nelson, M.D.3    Wood, J.C.4
  • 26
    • 18044399191 scopus 로고    scopus 로고
    • Cardiovascular T2-star (T2*) magnetic resonance for the early diagnosis of myocardial iron overload
    • Anderson LJ, Holden S, Davis B, et al. Cardiovascular T2-star (T2*) magnetic resonance for the early diagnosis of myocardial iron overload. Eur Heart J 2001; 22: 2171-2179.
    • (2001) Eur Heart J , vol.22 , pp. 2171-2179
    • Anderson, L.J.1    Holden, S.2    Davis, B.3
  • 28
    • 79951838524 scopus 로고    scopus 로고
    • Relaxivity-iron calibration in hepatic iron overload: Probing underlying biophysical mechanisms using a Monte Carlo model
    • Ghugre NR, Wood JC,. Relaxivity-iron calibration in hepatic iron overload: probing underlying biophysical mechanisms using a Monte Carlo model. Magn Reson Med 2011; 65: 837-847.
    • (2011) Magn Reson Med , vol.65 , pp. 837-847
    • Ghugre, N.R.1    Wood, J.C.2
  • 29
    • 10044235369 scopus 로고    scopus 로고
    • MRI measurement of hepatic magnetic susceptibility-phantom validation and normal subject studies
    • Chu Z, Cohen AR, Muthupillai R, Chung T, Wang ZJ,. MRI measurement of hepatic magnetic susceptibility-phantom validation and normal subject studies. Magn Reson Med 2004; 52: 1318-1327.
    • (2004) Magn Reson Med , vol.52 , pp. 1318-1327
    • Chu, Z.1    Cohen, A.R.2    Muthupillai, R.3    Chung, T.4    Wang, Z.J.5
  • 30
    • 0033210818 scopus 로고    scopus 로고
    • Magnetic resonance imaging measurement of volume magnetic susceptibility using a boundary condition
    • Wang ZJ, Li S, Haselgrove JC,. Magnetic resonance imaging measurement of volume magnetic susceptibility using a boundary condition. J Magn Reson 1999; 140: 477-481.
    • (1999) J Magn Reson , vol.140 , pp. 477-481
    • Wang, Z.J.1    Li, S.2    Haselgrove, J.C.3
  • 31
    • 77649342535 scopus 로고    scopus 로고
    • Assessment of cardiac iron by MRI susceptometry and R2* in patients with thalassemia
    • Wang ZJ, Fischer R, Chu Z, et al. Assessment of cardiac iron by MRI susceptometry and R2* in patients with thalassemia. Magn Reson Imaging 2010; 28: 363-371.
    • (2010) Magn Reson Imaging , vol.28 , pp. 363-371
    • Wang, Z.J.1    Fischer, R.2    Chu, Z.3
  • 32
    • 84883238435 scopus 로고    scopus 로고
    • Quantification of the magnetic susceptibility of the heart using MRI: Demonstration on normal subjects
    • In, Miami, Florida, USA
    • Wang ZJ, Chu Z, Chung T, Muthupillai R,. Quantification of the magnetic susceptibility of the heart using MRI: demonstration on normal subjects. In Proceedings of the 13th Annual Meeting of ISMRM, Miami, Florida, USA, 2005. p. 1666.
    • (2005) Proceedings of the 13th Annual Meeting of ISMRM , pp. 1666
    • Wang, Z.J.1    Chu, Z.2    Chung, T.3    Muthupillai, R.4
  • 33
    • 29744439189 scopus 로고    scopus 로고
    • Measurement and mapping of liver iron concentrations using magnetic resonance imaging
    • St Pierre TG, Clark PR, Chua-Anusorn W,. Measurement and mapping of liver iron concentrations using magnetic resonance imaging. Ann N Y Acad Sci 2005; 1054: 379-385.
    • (2005) Ann N y Acad Sci , vol.1054 , pp. 379-385
    • St Pierre, T.G.1    Clark, P.R.2    Chua-Anusorn, W.3
  • 36
    • 0026767986 scopus 로고
    • Health and physiological effects of human exposure to whole-body four-tesla magnetic fields during MRI
    • Schenck JF,. Health and physiological effects of human exposure to whole-body four-tesla magnetic fields during MRI. Ann N Y Acad Sci 1992; 649: 285-301.
    • (1992) Ann N y Acad Sci , vol.649 , pp. 285-301
    • Schenck, J.F.1
  • 37
    • 29744467874 scopus 로고    scopus 로고
    • Monitoring long-term efficacy of iron chelation treatment with biomagnetic liver susceptometry
    • Fischer R, Piga A, Harmatz P, Nielsen P,. Monitoring long-term efficacy of iron chelation treatment with biomagnetic liver susceptometry. Ann N Y Acad Sci 2005; 1054: 350-357.
    • (2005) Ann N y Acad Sci , vol.1054 , pp. 350-357
    • Fischer, R.1    Piga, A.2    Harmatz, P.3    Nielsen, P.4
  • 38
    • 0022656390 scopus 로고
    • Value of hepatic iron measurements in early hemochromatosis and determination of the critical iron level associated with fibrosis
    • Bassett ML, Halliday JW, Powell LW,. Value of hepatic iron measurements in early hemochromatosis and determination of the critical iron level associated with fibrosis. Hepatology 1986; 6: 24-29.
    • (1986) Hepatology , vol.6 , pp. 24-29
    • Bassett, M.L.1    Halliday, J.W.2    Powell, L.W.3
  • 39
    • 70350462793 scopus 로고    scopus 로고
    • T1 independent, T2* corrected MRI with accurate spectral modeling for quantification of fat: Validation in a fat-water-SPIO phantom
    • Hines CD, Yu H, Shimakawa A, McKenzie CA, Brittain JH, Reeder SB,. T1 independent, T2* corrected MRI with accurate spectral modeling for quantification of fat: validation in a fat-water-SPIO phantom. J Magn Reson Imaging 2009; 30: 1215-1222.
    • (2009) J Magn Reson Imaging , vol.30 , pp. 1215-1222
    • Hines, C.D.1    Yu, H.2    Shimakawa, A.3    McKenzie, C.A.4    Brittain, J.H.5    Reeder, S.B.6
  • 40
    • 79952291566 scopus 로고    scopus 로고
    • Quantification of hepatic steatosis with T1-independent, T2-corrected MR imaging with spectral modeling of fat: Blinded comparison with MR spectroscopy
    • Meisamy S, Hines CD, Hamilton G, Sirlin CB, McKenzie CA, Yu H, Brittain JH, Reeder SB,. Quantification of hepatic steatosis with T1-independent, T2-corrected MR imaging with spectral modeling of fat: blinded comparison with MR spectroscopy. Radiology 2011; 258: 767-775.
    • (2011) Radiology , vol.258 , pp. 767-775
    • Meisamy, S.1    Hines, C.D.2    Hamilton, G.3    Sirlin, C.B.4    McKenzie, C.A.5    Yu, H.6    Brittain, J.H.7    Reeder, S.B.8
  • 41
    • 38949120094 scopus 로고    scopus 로고
    • Comparison of reconstruction accuracy and efficiency among autocalibrating data-driven parallel imaging methods
    • Brau AC, Beatty PJ, Skare S, Bammer R,. Comparison of reconstruction accuracy and efficiency among autocalibrating data-driven parallel imaging methods. Magn Reson Med 2008; 59: 382-395.
    • (2008) Magn Reson Med , vol.59 , pp. 382-395
    • Brau, A.C.1    Beatty, P.J.2    Skare, S.3    Bammer, R.4
  • 43
    • 0034060592 scopus 로고    scopus 로고
    • Adaptive reconstruction of phased array MR imagery
    • Walsh DO, Gmitro AF, Marcellin MW,. Adaptive reconstruction of phased array MR imagery. Magn Reson Med 2000; 43: 682-690.
    • (2000) Magn Reson Med , vol.43 , pp. 682-690
    • Walsh, D.O.1    Gmitro, A.F.2    Marcellin, M.W.3
  • 44
    • 55749085613 scopus 로고    scopus 로고
    • Multiecho water-fat separation and simultaneous R2* estimation with multifrequency fat spectrum modeling
    • Yu H, Shimakawa A, McKenzie CA, Brodsky E, Brittain JH, Reeder SB,. Multiecho water-fat separation and simultaneous R2* estimation with multifrequency fat spectrum modeling. Magn Reson Med 2008; 60: 1122-1134.
    • (2008) Magn Reson Med , vol.60 , pp. 1122-1134
    • Yu, H.1    Shimakawa, A.2    McKenzie, C.A.3    Brodsky, E.4    Brittain, J.H.5    Reeder, S.B.6
  • 45
    • 77956360552 scopus 로고    scopus 로고
    • Chemical shift-based water/fat separation: A comparison of signal models
    • Hernando D, Liang ZP, Kellman P,. Chemical shift-based water/fat separation: a comparison of signal models. Magn Reson Med 2010; 64: 811-822.
    • (2010) Magn Reson Med , vol.64 , pp. 811-822
    • Hernando, D.1    Liang, Z.P.2    Kellman, P.3
  • 47
    • 73349138535 scopus 로고    scopus 로고
    • Robust water/fat separation in the presence of large field inhomogeneities using a graph cut algorithm
    • Hernando D, Kellman P, Haldar JP, Liang ZP,. Robust water/fat separation in the presence of large field inhomogeneities using a graph cut algorithm. Magn Reson Med 2010; 63: 79-90.
    • (2010) Magn Reson Med , vol.63 , pp. 79-90
    • Hernando, D.1    Kellman, P.2    Haldar, J.P.3    Liang, Z.P.4
  • 48
    • 34547934476 scopus 로고    scopus 로고
    • Fat quantification with IDEAL gradient echo imaging: Correction of bias from T(1) and noise
    • Liu CY, McKenzie CA, Yu H, Brittain JH, Reeder SB,. Fat quantification with IDEAL gradient echo imaging: correction of bias from T(1) and noise. Magn Reson Med 2007; 58: 354-364.
    • (2007) Magn Reson Med , vol.58 , pp. 354-364
    • Liu, C.Y.1    McKenzie, C.A.2    Yu, H.3    Brittain, J.H.4    Reeder, S.B.5
  • 49
    • 0029142532 scopus 로고
    • Physical and chemical properties of superparamagnetic iron oxide MR contrast agents: Ferumoxides, ferumoxtran, ferumoxsil
    • Jung CW, Jacobs P,. Physical and chemical properties of superparamagnetic iron oxide MR contrast agents: ferumoxides, ferumoxtran, ferumoxsil. Magn Reson Imaging 1995; 13: 661-674.
    • (1995) Magn Reson Imaging , vol.13 , pp. 661-674
    • Jung, C.W.1    Jacobs, P.2
  • 50
    • 0042808828 scopus 로고    scopus 로고
    • Bi-exponential proton transverse relaxation rate (R2) image analysis using RF field intensity-weighted spin density projection: Potential for R2 measurement of iron-loaded liver
    • Clark PR, Chua-anusorn W, St Pierre TG,. Bi-exponential proton transverse relaxation rate (R2) image analysis using RF field intensity-weighted spin density projection: potential for R2 measurement of iron-loaded liver. Magn Reson Imaging 2003; 21: 519-530.
    • (2003) Magn Reson Imaging , vol.21 , pp. 519-530
    • Clark, P.R.1    Chua-Anusorn, W.2    St Pierre, T.G.3
  • 54
    • 84883227220 scopus 로고    scopus 로고
    • Magnetic susceptibility as a field-independent MRI biomarker of liver iron overload
    • In, Salt Lake City, Utah, USA
    • Hernando D, Reeder SB,. Magnetic susceptibility as a field-independent MRI biomarker of liver iron overload. In Proceedings of the 21st Annual Meeting of ISMRM, Salt Lake City, Utah, USA, 2013. p. 3848.
    • (2013) Proceedings of the 21st Annual Meeting of ISMRM , pp. 3848
    • Hernando, D.1    Reeder, S.B.2
  • 55
  • 56


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.