메뉴 건너뛰기




Volumn 31, Issue 5, 2010, Pages 1264-1271

Phase and amplitude correction for multi-echo water-fat separation with bipolar acquisitions

Author keywords

Bandpass filter asymmetry; Bipolar gradient; Eddy currents; Multi echo; Oblique scan; Water fat separation

Indexed keywords

AMPLITUDE MODULATION; ARTICLE; MULTI ECHO WATER FAT SEPARATION; PRIORITY JOURNAL; SEPARATION TECHNIQUE;

EID: 77951585972     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.22111     Document Type: Article
Times cited : (58)

References (23)
  • 1
    • 0021132985 scopus 로고
    • Simple proton spectroscopic imaging
    • Dixon WT. Simple proton spectroscopic imaging. Radiology 1984; 153:189-194.
    • (1984) Radiology , vol.153 , pp. 189-194
    • Dixon, W.T.1
  • 2
    • 0026216918 scopus 로고
    • Multipoint Dixon technique for water and fat proton and susceptibility imaging
    • Glover GH. Multipoint Dixon technique for water and fat proton and susceptibility imaging. J Magn Reson Imaging 1991;1:521-530.
    • (1991) J Magn Reson Imaging , vol.1 , pp. 521-530
    • Glover, G.H.1
  • 3
    • 0025831477 scopus 로고
    • Three-point Dixon technique for true water/fat decomposition with B0 inhomogeneity correction
    • Glover GH, Schneider E. Three-point Dixon technique for true water/fat decomposition with B0 inhomogeneity correction. Magn Reson Med 1991;18:371-383.
    • (1991) Magn Reson Med , vol.18 , pp. 371-383
    • Glover, G.H.1    Schneider, E.2
  • 4
    • 34250336900 scopus 로고    scopus 로고
    • Fast decomposition of water and lipid using a GRASE technique with the IDEAL algorithm
    • DOI 10.1002/mrm.21232
    • Li Z, Gmitro AF, Bilgin A, Altbach MI. Fast decomposition of water and lipid using a GRASE technique with the IDEAL algorithm. Magn Reson Med 2007;57:1047-1057. (Pubitemid 46911289)
    • (2007) Magnetic Resonance in Medicine , vol.57 , Issue.6 , pp. 1047-1057
    • Li, Z.1    Gmitro, A.F.2    Bilgin, A.3    Altbach, M.I.4
  • 6
    • 34547736137 scopus 로고    scopus 로고
    • 2-weighted water and fat imaging
    • DOI 10.1002/mrm.21268
    • Ma J, Son JB, Zhou Y, Le-Petross H, Choi H. Fast spin-echo triple-echo dixon (fTED) technique for efficient T2-weighted water and fat imaging. Magn Reson Med 2007;58:103-109. (Pubitemid 47229922)
    • (2007) Magnetic Resonance in Medicine , vol.58 , Issue.1 , pp. 103-109
    • Ma, J.1    Jong, B.S.2    Zhou, Y.3    Le-Petross, H.4    Choi, H.5
  • 8
    • 26844562367 scopus 로고    scopus 로고
    • Field map estimation with a region growing scheme for iterative 3-point water-fat decomposition
    • DOI 10.1002/mrm.20654
    • Yu H, Reeder SB, Shimakawa A, Brittain JH, Pelc NJ. Field map estimation with a region growing scheme for iterative 3-point water-fat decomposition. Magn Reson Med 2005;54:1032-1039. (Pubitemid 41457077)
    • (2005) Magnetic Resonance in Medicine , vol.54 , Issue.4 , pp. 1032-1039
    • Yu, H.1    Reeder, S.B.2    Shimakawa, A.3    Brittain, J.H.4    Pelc, N.J.5
  • 10
    • 42549084784 scopus 로고    scopus 로고
    • Generalized K-space decomposition with chemical shift correction for non-Cartesian water-fat imaging
    • DOI 10.1002/mrm.21580
    • Brodsky EK, Holmes JH, Yu H, Reeder SB. Generalized k-space decomposition with chemical shift correction for non-Cartesian water-fat imaging. Magn Reson Med 2008;59:1151-1164. (Pubitemid 351590529)
    • (2008) Magnetic Resonance in Medicine , vol.59 , Issue.5 , pp. 1151-1164
    • Brodsky, E.K.1    Holmes, J.H.2    Yu, H.3    Reeder, S.B.4
  • 11
    • 0030802130 scopus 로고    scopus 로고
    • Ghost artifact reduction for echo planar imaging using image phase correction
    • DOI 10.1002/mrm.1910380114
    • Buonocore MH, Gao L. Ghost artifact reduction for echo planar imaging using image phase correction. Magn Reson Med 1997; 38:89-100. (Pubitemid 27284268)
    • (1997) Magnetic Resonance in Medicine , vol.38 , Issue.1 , pp. 89-100
    • Buonocore, M.H.1    Gao, L.2
  • 12
    • 0032761403 scopus 로고    scopus 로고
    • Two-dimensional deghosting for EPI
    • Hennel F. Two-dimensional deghosting for EPI. MAGMA 1999;9: 134-137.
    • (1999) MAGMA , vol.9 , pp. 134-137
    • Hennel, F.1
  • 13
    • 2942748091 scopus 로고    scopus 로고
    • Removal of EPI Nyquist ghost artifacts with two-dimensional phase correction
    • Chen NK, Wyrwicz AM. Removal of EPI Nyquist ghost artifacts with two-dimensional phase correction. Magn Reson Med 2004; 51:1247-1253.
    • (2004) Magn Reson Med , vol.51 , pp. 1247-1253
    • Chen, N.K.1    Wyrwicz, A.M.2
  • 14
    • 0036327289 scopus 로고    scopus 로고
    • Characterization and reduction of gradient-induced eddy currents in the RF shield of a TEM resonator
    • DOI 10.1002/mrm.10226
    • Alecci M, Jezzard P. Characterization and reduction of gradient-induced eddy currents in the RF shield of a TEM resonator. Magn Reson Med 2002;48:404-407. (Pubitemid 34809432)
    • (2002) Magnetic Resonance in Medicine , vol.48 , Issue.2 , pp. 404-407
    • Alecci, M.1    Jezzard, P.2
  • 17
    • 22944435560 scopus 로고    scopus 로고
    • MRI receiver frequency response as a contributor to Nyquist ghosting in echo planar imaging
    • DOI 10.1002/jmri.20365
    • Delakis I, Petala K, De Wilde JP. MRI receiver frequency response as a contributor to Nyquist ghosting in echo planar imaging. J Magn Reson Imaging 2005;22:324-328. (Pubitemid 41045450)
    • (2005) Journal of Magnetic Resonance Imaging , vol.22 , Issue.2 , pp. 324-328
    • Delakis, I.1    Petala, K.2    De Wilde, J.P.3
  • 19
  • 20
    • 0025732199 scopus 로고
    • Potential degradation in image quality due to selective averaging of phase-encoding lines in Fourier transform MRI
    • Mugler JP III. Potential degradation in image quality due to selective averaging of phase-encoding lines in Fourier transform MRI. Magn Reson Med 1991;19:170-174.
    • (1991) Magn Reson Med , vol.19 , pp. 170-174
    • Mugler III, J.P.1
  • 21
    • 30744448686 scopus 로고    scopus 로고
    • Fat-suppressed three-dimensional dual echo dixon technique for contrast agent enhanced MRI
    • DOI 10.1002/jmri.20470
    • Ma J, Vu AT, Son JB, Choi H, Hazle JD. Fat-suppressed three-dimensional dual echo Dixon technique for contrast agent enhanced MRI. J Magn Reson Imaging 2006;23:36-41. (Pubitemid 43100716)
    • (2006) Journal of Magnetic Resonance Imaging , vol.23 , Issue.1 , pp. 36-41
    • Ma, J.1    Vu, A.T.2    Son, J.B.3    Choi, H.4    Hazle, J.D.5
  • 22
    • 55749102851 scopus 로고    scopus 로고
    • Linear phase-error correction for improved water and fat separation in dual-echo dixon techniques
    • Ma J, Slavens Z, Sun W, Bayram E, Estowski L, Hwang KP, Akao J, Vu AT. Linear phase-error correction for improved water and fat separation in dual-echo dixon techniques. Magn Reson Med 2008;60:1250-1255.
    • (2008) Magn Reson Med , vol.60 , pp. 1250-1255
    • Ma, J.1    Slavens, Z.2    Sun, W.3    Bayram, E.4    Estowski, L.5    Hwang, K.P.6    Akao, J.7    Vu, A.T.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.