메뉴 건너뛰기




Volumn 54, Issue 5, 2005, Pages 1185-1193

Mechanisms of tissue-iron relaxivity: Nuclear magnetic resonance studies of human liver biopsy specimens

Author keywords

Iron overload; Liver; Magnetic susceptibility; Mathematical modeling; Relaxation

Indexed keywords

BIOPSY; IRON; LIVER; MAGNETIC SUSCEPTIBILITY; MAGNETISM; MATHEMATICAL MODELS; TISSUE;

EID: 27644555993     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.20697     Document Type: Article
Times cited : (86)

References (37)
  • 2
    • 0031001278 scopus 로고    scopus 로고
    • Iron-chelating therapy and the treatment of thalassemia
    • Olivieri NF, Brittenham GM. Iron-chelating therapy and the treatment of thalassemia. Blood 1997;89:739-761.
    • (1997) Blood , vol.89 , pp. 739-761
    • Olivieri, N.F.1    Brittenham, G.M.2
  • 3
    • 0027043081 scopus 로고
    • Outcome of patients hospitalized for complications after outpatient liver biopsy
    • Janes CH, Lindor KD. Outcome of patients hospitalized for complications after outpatient liver biopsy. Ann Intern Med 1993;118:96-98.
    • (1993) Ann Intern Med , vol.118 , pp. 96-98
    • Janes, C.H.1    Lindor, K.D.2
  • 5
    • 0001265554 scopus 로고    scopus 로고
    • Variability in hepatic iron concentration measurement from needle-biopsy specimens
    • Villeneuve JP, Bilodeau M, Lepage R, Cote J, Lefebvre M. Variability in hepatic iron concentration measurement from needle-biopsy specimens. J Hepatol 1996;25:172-177.
    • (1996) J Hepatol , vol.25 , pp. 172-177
    • Villeneuve, J.P.1    Bilodeau, M.2    Lepage, R.3    Cote, J.4    Lefebvre, M.5
  • 6
    • 0037217987 scopus 로고    scopus 로고
    • Noninvasive measurement of iron: Report of an NIDDK workshop
    • Brittenham GM, Badman DG. Noninvasive measurement of iron: report of an NIDDK workshop. Blood 2003;101:15-19.
    • (2003) Blood , vol.101 , pp. 15-19
    • Brittenham, G.M.1    Badman, D.G.2
  • 11
    • 0027105188 scopus 로고
    • Identification of patients with hereditary haemochromatosis by magnetic resonance imaging and spectroscopic relaxation time measurements
    • Thomsen C, Wiggers P, Ring-Larsen H, Christiansen E, Dalhoj J, Henriksen O, Christoffersen P. Identification of patients with hereditary haemochromatosis by magnetic resonance imaging and spectroscopic relaxation time measurements. Magn Reson Imaging 1992;10:867-879.
    • (1992) Magn Reson Imaging , vol.10 , pp. 867-879
    • Thomsen, C.1    Wiggers, P.2    Ring-Larsen, H.3    Christiansen, E.4    Dalhoj, J.5    Henriksen, O.6    Christoffersen, P.7
  • 13
    • 0030911943 scopus 로고    scopus 로고
    • Hepatic hemosiderosis in non-human primates: Quantification of liver iron using different field strengths
    • Bulte JW, Miller GF, Vymazal J, Brooks RA, Frank JA. Hepatic hemosiderosis in non-human primates: quantification of liver iron using different field strengths. Magn Reson Med 1997;37:530-536.
    • (1997) Magn Reson Med , vol.37 , pp. 530-536
    • Bulte, J.W.1    Miller, G.F.2    Vymazal, J.3    Brooks, R.A.4    Frank, J.A.5
  • 14
    • 0034744087 scopus 로고    scopus 로고
    • On T2-shortening by weakly magnetized particles: The chemical exchange model
    • Brooks RA, Moiny F, Gillis P. On T2-shortening by weakly magnetized particles: the chemical exchange model. Magn Reson Med 2001;45:1014-1020.
    • (2001) Magn Reson Med , vol.45 , pp. 1014-1020
    • Brooks, R.A.1    Moiny, F.2    Gillis, P.3
  • 15
    • 0036264295 scopus 로고    scopus 로고
    • Theory of nonexponential NMR signal decay in liver with iron overload or superparamagnetic iron oxide particles
    • Jensen JH, Chandra R. Theory of nonexponential NMR signal decay in liver with iron overload or superparamagnetic iron oxide particles. Magn Reson Med 2002;47:1131-1138.
    • (2002) Magn Reson Med , vol.47 , pp. 1131-1138
    • Jensen, J.H.1    Chandra, R.2
  • 16
    • 0036163129 scopus 로고    scopus 로고
    • On T(2)-shortening by strongly magnetized spheres: A partial refocusing model
    • Gillis P, Moiny F, Brooks RA. On T(2)-shortening by strongly magnetized spheres: a partial refocusing model. Magn Reson Med 2002;47:257-263.
    • (2002) Magn Reson Med , vol.47 , pp. 257-263
    • Gillis, P.1    Moiny, F.2    Brooks, R.A.3
  • 18
    • 34249771074 scopus 로고
    • On the convergence of reflective newton methods for large-scale nonlinear minimization subject to bounds
    • Coleman TF, Li YY. On the convergence of reflective newton methods for large-scale nonlinear minimization subject to bounds. Math Program 1994;67:189-224.
    • (1994) Math Program , vol.67 , pp. 189-224
    • Coleman, T.F.1    Li, Y.Y.2
  • 19
    • 0030303844 scopus 로고    scopus 로고
    • An interior trust region approach for nonlinear minimization subject to bounds
    • Coleman TF, Li YY. An interior trust region approach for nonlinear minimization subject to bounds. Siam J Optimiz 1996;6:418-445.
    • (1996) Siam J Optimiz , vol.6 , pp. 418-445
    • Coleman, T.F.1    Li, Y.Y.2
  • 20
    • 0032975435 scopus 로고    scopus 로고
    • Diffusion coefficients in abdominal organs and hepatic lesions: Evaluation with intravoxel incoherent motion echo-planar MR imaging
    • Yamada I, Aung W, Himeno Y, Nakagawa T, Shibuya H. Diffusion coefficients in abdominal organs and hepatic lesions: evaluation with intravoxel incoherent motion echo-planar MR imaging. Radiology 1999;210:617-623.
    • (1999) Radiology , vol.210 , pp. 617-623
    • Yamada, I.1    Aung, W.2    Himeno, Y.3    Nakagawa, T.4    Shibuya, H.5
  • 22
    • 0032185781 scopus 로고    scopus 로고
    • Intravascular and intracellular hepatic relaxivities of superparamagnetic particles: An isolated and perfused organ pharmacokinetics study
    • Colet JM, Pierart C, Seghi F, Gabric I, Muller RN. Intravascular and intracellular hepatic relaxivities of superparamagnetic particles: an isolated and perfused organ pharmacokinetics study. J Magn Reson 1998;134:199-205.
    • (1998) J Magn Reson , vol.134 , pp. 199-205
    • Colet, J.M.1    Pierart, C.2    Seghi, F.3    Gabric, I.4    Muller, R.N.5
  • 23
    • 0025294625 scopus 로고
    • Signal loss induced by superparamagnetic iron oxide particles in NMR spin-echo images: The role of diffusion
    • Rozenman Y, Zou X, Kantor H. Signal loss induced by superparamagnetic iron oxide particles in NMR spin-echo images: the role of diffusion. Magn Reson Med 1990;14:14-31.
    • (1990) Magn Reson Med , vol.14 , pp. 14-31
    • Rozenman, Y.1    Zou, X.2    Kantor, H.3
  • 24
    • 0033972949 scopus 로고    scopus 로고
    • Strong field behavior of the NMR signal from magnetically heterogeneous tissues
    • Jensen JH, Chandra R. Strong field behavior of the NMR signal from magnetically heterogeneous tissues. Magn Reson Med 2000;43:226-236.
    • (2000) Magn Reson Med , vol.43 , pp. 226-236
    • Jensen, J.H.1    Chandra, R.2
  • 28
    • 0023716009 scopus 로고
    • Quantitation of MR relaxation effects of iron oxide particles in liver and spleen
    • Majumdar S, Zoghbi S, Pope CF, Gore JC. Quantitation of MR relaxation effects of iron oxide particles in liver and spleen. Radiology 1988;169: 653-658.
    • (1988) Radiology , vol.169 , pp. 653-658
    • Majumdar, S.1    Zoghbi, S.2    Pope, C.F.3    Gore, J.C.4
  • 29
    • 0024512323 scopus 로고
    • A quantitative study of relaxation rate enhancement produced by iron oxide particles in polyacrylamide gels and tissue
    • Majumdar S, Zoghbi S, Pope CF, Gore JC. A quantitative study of relaxation rate enhancement produced by iron oxide particles in polyacrylamide gels and tissue. Magn Reson Med 1989;9:185-202.
    • (1989) Magn Reson Med , vol.9 , pp. 185-202
    • Majumdar, S.1    Zoghbi, S.2    Pope, C.F.3    Gore, J.C.4
  • 30
    • 0023091772 scopus 로고
    • Effects of selective pulses on the measurement of T2 and apparent diffusion in multiecho MRI
    • Majumdar S, Gore JC. Effects of selective pulses on the measurement of T2 and apparent diffusion in multiecho MRI. Magn Reson Med 1987;4:120-128.
    • (1987) Magn Reson Med , vol.4 , pp. 120-128
    • Majumdar, S.1    Gore, J.C.2
  • 31
    • 0024323153 scopus 로고
    • The influence of pulse sequence on the relaxation effects of superparamagnetic iron oxide contrast agents
    • Majumdar S, Zoghbi SS, Gore JC. The influence of pulse sequence on the relaxation effects of superparamagnetic iron oxide contrast agents. Magn Reson Med 1989;10:289-301.
    • (1989) Magn Reson Med , vol.10 , pp. 289-301
    • Majumdar, S.1    Zoghbi, S.S.2    Gore, J.C.3
  • 33
    • 1542376663 scopus 로고    scopus 로고
    • Mimicking liver iron overload using liposomal ferritin preparations
    • Wood JC, Fassler JD, Meade T. Mimicking liver iron overload using liposomal ferritin preparations. Magn Reson Med 2004;51:607-611.
    • (2004) Magn Reson Med , vol.51 , pp. 607-611
    • Wood, J.C.1    Fassler, J.D.2    Meade, T.3
  • 37
    • 0029685342 scopus 로고    scopus 로고
    • Quantitative magnetic resonance methods for in vivo investigation of the human liver and spleen. Technical aspects and preliminary clinical results
    • Thomsen C. Quantitative magnetic resonance methods for in vivo investigation of the human liver and spleen. Technical aspects and preliminary clinical results. Acta Radiol Suppl 1996;401:1-34.
    • (1996) Acta Radiol Suppl , vol.401 , pp. 1-34
    • Thomsen, C.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.