메뉴 건너뛰기




Volumn 22, Issue 8, 2013, Pages 1829-1836

Effect of pilot hole on biomechanical and in vivo pedicle screw-bone interface

Author keywords

Biomechanics; Bone screws; Histology; Spine

Indexed keywords

ANIMAL EXPERIMENT; ARTICLE; BIOMECHANICS; BONE IMPLANT; IN VIVO STUDY; MORPHOMETRICS; MUSCULOSKELETAL SYSTEM PARAMETERS; NONHUMAN; PEDICLE SCREW; PILOT HOLE DIAMETER; PRIORITY JOURNAL; SHEEP; TORQUE; ANIMAL; ANIMAL MODEL; BONE SCREW; DEVICES; LUMBAR VERTEBRA; MALE; MATERIALS TESTING; ORTHOPEDIC SURGERY; PROCEDURES; SURGERY;

EID: 84881521297     PISSN: 09406719     EISSN: 14320932     Source Type: Journal    
DOI: 10.1007/s00586-013-2810-9     Document Type: Article
Times cited : (25)

References (42)
  • 1
    • 0035851762 scopus 로고    scopus 로고
    • Characteristics of pullout failure in conical and cylindrical pedicle screws after full insertion and back-out
    • 14588297 10.1016/S1529-9430(01)00119-X 1:STN:280:DC%2BD3srhsFSnsg%3D%3D
    • Abshire BB, McLain RF, Valdevit A et al (2001) Characteristics of pullout failure in conical and cylindrical pedicle screws after full insertion and back-out. Spine J 1:408-414
    • (2001) Spine J , vol.1 , pp. 408-414
    • Abshire, B.B.1    McLain, R.F.2    Valdevit, A.3
  • 2
    • 0023626715 scopus 로고
    • Stabilization of the lower thoracic and lumbar spine with the internal spinal skeletal fixation system. Indications, techniques, and first results of treatment
    • 10.1097/00007632-198707000-00007 1:STN:280:DyaL1c%2FhvVamsg%3D%3D
    • Aebi M, Etter C, Kehl T et al (1987) Stabilization of the lower thoracic and lumbar spine with the internal spinal skeletal fixation system. Indications, techniques, and first results of treatment. Spine (Phila Pa 1976) 12:544-551
    • (1987) Spine (Phila Pa 1976) , vol.12 , pp. 544-551
    • Aebi, M.1    Etter, C.2    Kehl, T.3
  • 3
    • 75749112204 scopus 로고    scopus 로고
    • Implant-bone interfaces
    • E.C. Benzel (eds) Thieme New York
    • Benzel EC (2011) Implant-bone interfaces. In: Benzel EC (ed) Biomechanics of spinal stabilization. Thieme, New York, pp 155-170
    • (2011) Biomechanics of Spinal Stabilization , pp. 155-170
    • Benzel, E.C.1
  • 4
    • 34548672563 scopus 로고    scopus 로고
    • Influence of implant diameter on surrounding bone
    • 17590162 10.1111/j.1600-0501.2007.01283.x
    • Brink J, Meraw SJ, Sarment DP (2007) Influence of implant diameter on surrounding bone. Clin Oral Implants Res 18:563-568
    • (2007) Clin Oral Implants Res , vol.18 , pp. 563-568
    • Brink, J.1    Meraw, S.J.2    Sarment, D.P.3
  • 5
    • 32944462062 scopus 로고    scopus 로고
    • Effects of pilot hole preparation technique on pedicle screw fixation in different regions of the osteoporotic thoracic and lumbar spine
    • 16302630 10.3171/spi.2005.3.5.0364
    • Carmouche JJ, Molinari RW, Gerlinger T et al (2005) Effects of pilot hole preparation technique on pedicle screw fixation in different regions of the osteoporotic thoracic and lumbar spine. J Neurosurg Spine 3:364-370
    • (2005) J Neurosurg Spine , vol.3 , pp. 364-370
    • Carmouche, J.J.1    Molinari, R.W.2    Gerlinger, T.3
  • 6
    • 75749134043 scopus 로고    scopus 로고
    • A parametric study of cylindrical pedicle screw design implications on the pullout performance using an experimentally validated finite-element model
    • 19945333 10.1016/j.medengphy.2009.11.003
    • Chatzistergos PE, Magnissalis EA, Kourkoulis SK (2010) A parametric study of cylindrical pedicle screw design implications on the pullout performance using an experimentally validated finite-element model. Med Eng Phys 32:145-154
    • (2010) Med Eng Phys , vol.32 , pp. 145-154
    • Chatzistergos, P.E.1    Magnissalis, E.A.2    Kourkoulis, S.K.3
  • 7
    • 77951765869 scopus 로고    scopus 로고
    • The Influence of the insertion technique on the pullout force of pedicle screws: An experimental study
    • 20150834 10.1097/BRS.0b013e3181ba0b0c
    • Chatzistergos PE, Sapkas G, Kourkoulis SK (2010) The Influence of the insertion technique on the pullout force of pedicle screws: an experimental study. Spine 35:E332-E337
    • (2010) Spine , vol.35
    • Chatzistergos, P.E.1    Sapkas, G.2    Kourkoulis, S.K.3
  • 8
    • 0026409596 scopus 로고
    • Dose effects on ewe bone remodeling of short-term sodium fluoride administration-a histomorphometric and biochemical study
    • 1797057 10.1016/8756-3282(91)90031-D 1:CAS:528:DyaK38XltlWqtg%3D%3D
    • Chavassieux P, Pastoureau P, Boivin G et al (1991) Dose effects on ewe bone remodeling of short-term sodium fluoride administration-a histomorphometric and biochemical study. Bone 12:421-442
    • (1991) Bone , vol.12 , pp. 421-442
    • Chavassieux, P.1    Pastoureau, P.2    Boivin, G.3
  • 9
    • 0037400997 scopus 로고    scopus 로고
    • Biomechanical investigation of pedicle screw-vertebrae complex: A finite element approach using bonded and contact interface conditions
    • 12649011 10.1016/S1350-4533(02)00219-9
    • Chen SI, Lin RM, Chang CH (2003) Biomechanical investigation of pedicle screw-vertebrae complex: a finite element approach using bonded and contact interface conditions. Med Eng Phys 25:275-282
    • (2003) Med Eng Phys , vol.25 , pp. 275-282
    • Chen, S.I.1    Lin, R.M.2    Chang, C.H.3
  • 10
    • 77955385364 scopus 로고    scopus 로고
    • The Biomechanics of pedicle screw-based instrumentation
    • 1:STN:280:DC%2BC3cjhslaqtQ%3D%3D
    • Cho W, Cho SK, Wu C (2010) The Biomechanics of pedicle screw-based instrumentation. J Bone Jt Surg 92:1061-1065
    • (2010) J Bone Jt Surg , vol.92 , pp. 1061-1065
    • Cho, W.1    Cho, S.K.2    Wu, C.3
  • 11
    • 0025153831 scopus 로고
    • Influence of bone mineral density on the fixation of thoracolumbar implants. A comparative study of transpedicular screws, laminar hooks, and spinous process wires
    • 2259978 10.1097/00007632-199009000-00012 1:STN:280:DyaK3M%2FotFyluw%3D%3D
    • Coe JD, Warden KE, Herzig MA et al (1990) Influence of bone mineral density on the fixation of thoracolumbar implants. A comparative study of transpedicular screws, laminar hooks, and spinous process wires. Spine 15:902-907
    • (1990) Spine , vol.15 , pp. 902-907
    • Coe, J.D.1    Warden, K.E.2    Herzig, M.A.3
  • 12
    • 33644874657 scopus 로고    scopus 로고
    • Biomechanical evaluation of the pullout strength of cervical screws
    • 16306839 10.1097/01.bsd.0000140196.99995.65
    • Conrad BP, Cordista AG, Horodyski M et al (2005) Biomechanical evaluation of the pullout strength of cervical screws. J Spinal Disord Tech 18:506-510
    • (2005) J Spinal Disord Tech , vol.18 , pp. 506-510
    • Conrad, B.P.1    Cordista, A.G.2    Horodyski, M.3
  • 13
    • 0034463634 scopus 로고    scopus 로고
    • Biomechanical evaluation and preliminary clinical experience with an expansive pedicle screw design
    • 10872761 10.1097/00002517-200006000-00006 1:STN:280: DC%2BD3M%2FgvFKqug%3D%3D
    • Cook SD, Salkeld SL, Whitecloud TS et al (2000) Biomechanical evaluation and preliminary clinical experience with an expansive pedicle screw design. J Spinal Disord 13:230-236
    • (2000) J Spinal Disord , vol.13 , pp. 230-236
    • Cook, S.D.1    Salkeld, S.L.2    Whitecloud, T.S.3
  • 14
    • 0028258268 scopus 로고
    • Correlations between screw hole preparation, torque of insertion, and pullout strength for spinal screws
    • 8003831 10.1097/00002517-199407020-00007 1:STN:280:DyaK2c3nt1Wksg%3D%3D
    • Daftari TK, Horton WC, Hutton WC (1994) Correlations between screw hole preparation, torque of insertion, and pullout strength for spinal screws. J Spinal Disord 7:139-145
    • (1994) J Spinal Disord , vol.7 , pp. 139-145
    • Daftari, T.K.1    Horton, W.C.2    Hutton, W.C.3
  • 15
    • 67650675604 scopus 로고    scopus 로고
    • The effect of repetitive pilot-hole use on the insertion torque and pullout strength of vertebral system screws
    • 10.1097/BRS.0b013e31819e3556
    • Defino HL, Rosa RC, Silva P et al (2009) The effect of repetitive pilot-hole use on the insertion torque and pullout strength of vertebral system screws. Spine (Phila Pa 1976) 34:871-876
    • (2009) Spine (Phila Pa 1976) , vol.34 , pp. 871-876
    • Defino, H.L.1    Rosa, R.C.2    Silva, P.3
  • 16
    • 34548686606 scopus 로고    scopus 로고
    • Influência do diâmetro do orifício piloto na resistência ao arrancamento dos parafusos do corpo vertebral
    • 10.1590/S1413-78522007000200003
    • Defino HLA, Wich C, Shimano A et al (2007) Influência do diâmetro do orifício piloto na resistência ao arrancamento dos parafusos do corpo vertebral. Acta Ortop Bras 15:76-79
    • (2007) Acta Ortop Bras , vol.15 , pp. 76-79
    • Defino, H.L.A.1    Wich, C.2    Shimano, A.3
  • 17
    • 0034881609 scopus 로고    scopus 로고
    • Role of cortical and cancellous bone of the vertebral pedicle in implant fixation
    • 10.1007/s005860000232
    • Defino HLA, Vendrame JR (2010) Role of cortical and cancellous bone of the vertebral pedicle in implant fixation. Eur Spine J 10:325-333
    • (2010) Eur Spine J , vol.10 , pp. 325-333
    • Defino, H.L.A.1    Vendrame, J.R.2
  • 18
    • 0033197576 scopus 로고    scopus 로고
    • New segmental long bone defect model in sheep: Quantitative analysis of healing with dual energy x-ray absorptiometry
    • 10.1002/jor.1100170506
    • den Boer FC, Patka P, Bakker FC (1999) New segmental long bone defect model in sheep: quantitative analysis of healing with dual energy x-ray absorptiometry. J Orthop Res 17:654-660
    • (1999) J Orthop Res , vol.17 , pp. 654-660
    • Den Boer, F.C.1    Patka, P.2    Bakker, F.C.3
  • 19
    • 0020790218 scopus 로고
    • Temperature threshold levels for heat-induced bone tissue injury: A vital-microscopic study in the rabbit
    • 6576145 10.1016/0022-3913(83)90174-9 1:STN:280:DyaL3s3mvVeluw%3D%3D
    • Eriksson AR, Albrektsson T (1983) Temperature threshold levels for heat-induced bone tissue injury: a vital-microscopic study in the rabbit. J Prosthet Dent 50:101-107
    • (1983) J Prosthet Dent , vol.50 , pp. 101-107
    • Eriksson, A.R.1    Albrektsson, T.2
  • 20
    • 75049085560 scopus 로고    scopus 로고
    • Alignment of pedicle screws with pilot holes: Can tap-ping improve screw trajectory in thoracic spines?
    • 19526377 10.1007/s00586-009-1063-0
    • Erkan S, Hsu B, Wu C et al (2010) Alignment of pedicle screws with pilot holes: can tap-ping improve screw trajectory in thoracic spines? Eur Spine J 19:71-77
    • (2010) Eur Spine J , vol.19 , pp. 71-77
    • Erkan, S.1    Hsu, B.2    Wu, C.3
  • 21
    • 21844480606 scopus 로고    scopus 로고
    • Increase of pullout strength of spinal pedicle screws with conical core: Biomechanical tests and finite element analyses
    • 16022991 10.1016/j.orthres.2004.11.002
    • Hsu CC, Chao CK, Wang JL et al (2005) Increase of pullout strength of spinal pedicle screws with conical core: biomechanical tests and finite element analyses. J Orthop Res 23:788-794
    • (2005) J Orthop Res , vol.23 , pp. 788-794
    • Hsu, C.C.1    Chao, C.K.2    Wang, J.L.3
  • 22
    • 33748034045 scopus 로고    scopus 로고
    • Axial cyclic behavior of the bone-screw interface
    • 16458568 10.1016/j.medengphy.2005.12.009
    • Inceoglu S, Ehlert M, Akbay A et al (2006) Axial cyclic behavior of the bone-screw interface. Med Eng Phys 28:888-893
    • (2006) Med Eng Phys , vol.28 , pp. 888-893
    • Inceoglu, S.1    Ehlert, M.2    Akbay, A.3
  • 23
    • 11144274603 scopus 로고    scopus 로고
    • Pedicle screw fixation strength: Pullout versus insertional torque
    • 15363421 10.1016/j.spinee.2004.02.006
    • Inceoglu S, Ferrara L, McLain RF (2004) Pedicle screw fixation strength: pullout versus insertional torque. Spine J 4:513-518
    • (2004) Spine J , vol.4 , pp. 513-518
    • Inceoglu, S.1    Ferrara, L.2    McLain, R.F.3
  • 24
    • 0347753912 scopus 로고    scopus 로고
    • Biomechanical considerations of animal models used in tissue engineering of bone
    • 14697871 10.1016/S0142-9612(03)00515-5 1:CAS:528:DC%2BD3sXpvFeltrg%3D
    • Liebschner MA (2004) Biomechanical considerations of animal models used in tissue engineering of bone. Biomaterials 25:1697-1714
    • (2004) Biomaterials , vol.25 , pp. 1697-1714
    • Liebschner, M.A.1
  • 25
    • 0034464574 scopus 로고    scopus 로고
    • Comparison of the in vitro holding strengths of conical and cylindrical pedicle screws in a fully inserted setting and backed out 180 degrees
    • 10872766 10.1097/00002517-200006000-00011 1:STN:280: DC%2BD3M%2FgvFOjsQ%3D%3D
    • Lill CA, Schlegel U, Wahl D et al (2000) Comparison of the in vitro holding strengths of conical and cylindrical pedicle screws in a fully inserted setting and backed out 180 degrees. J Spinal Disord 13:259-266
    • (2000) J Spinal Disord , vol.13 , pp. 259-266
    • Lill, C.A.1    Schlegel, U.2    Wahl, D.3
  • 26
    • 0035890114 scopus 로고    scopus 로고
    • Biomechanical evaluation of diagonal fixation in pedicle screw instrumentation
    • 11707718 10.1097/00007632-200111150-00020 1:STN:280: DC%2BD3MnlsV2iug%3D%3D
    • Lim TH, Kim JG, Fujiwara A et al (2001) Biomechanical evaluation of diagonal fixation in pedicle screw instrumentation. Spine 26:2498-2503
    • (2001) Spine , vol.26 , pp. 2498-2503
    • Lim, T.H.1    Kim, J.G.2    Fujiwara, A.3
  • 27
    • 0029825385 scopus 로고    scopus 로고
    • Insertional torque and pull-out strengths of conical and cylindrical pedicle screws in cadaveric bone
    • 8923627 10.1097/00007632-199611010-00004 1:STN:280:DyaK2s%2Fot1eqsw%3D%3D
    • Kwok AW, Finkelstein JA, Woodside T et al (1996) Insertional torque and pull-out strengths of conical and cylindrical pedicle screws in cadaveric bone. Spine 21:2429-2434
    • (1996) Spine , vol.21 , pp. 2429-2434
    • Kwok, A.W.1    Finkelstein, J.A.2    Woodside, T.3
  • 28
    • 0038641208 scopus 로고    scopus 로고
    • The early tissue response to titanium and Lactosorb screws
    • 10.1034/j.1600-9657.2003.00103.x
    • Mallaoglu N, Çetiner S, Aspaslan C (2003) The early tissue response to titanium and Lactosorb screws. Dent Traumatol 19:139-144
    • (2003) Dent Traumatol , vol.19 , pp. 139-144
    • Mallaoglu, N.1    Çetiner, S.2    Aspaslan, C.3
  • 29
    • 0032151752 scopus 로고    scopus 로고
    • Assessment of implant stability as a prognostic determinant
    • 9922740 1:STN:280:DyaK1M7itFCqtw%3D%3D
    • Meredith N (1998) Assessment of implant stability as a prognostic determinant. Int J Prosthodont 11:491-501
    • (1998) Int J Prosthodont , vol.11 , pp. 491-501
    • Meredith, N.1
  • 30
    • 0029147322 scopus 로고
    • The potential of sheep for the study of osteopenia: Current status and comparison with other animal models
    • 7626315 1:STN:280:DyaK2Mzlt1ejtQ%3D%3D
    • Newman E, Turner AS, Wark JD (1995) The potential of sheep for the study of osteopenia: current status and comparison with other animal models. Bone 16:277S-284S
    • (1995) Bone , vol.16
    • Newman, E.1    Turner, A.S.2    Wark, J.D.3
  • 31
    • 0027384240 scopus 로고
    • Osteopenia and bone-remodeling abnormalities in warfarin-treated lambs
    • 8304041 10.1002/jbmr.5650081202 1:CAS:528:DyaK2cXktVKnt70%3D
    • Pastoureau P, Vergnaud P, Meunier PJ (1993) Osteopenia and bone-remodeling abnormalities in warfarin-treated lambs. J Bone Miner Res 8:1417-1426
    • (1993) J Bone Miner Res , vol.8 , pp. 1417-1426
    • Pastoureau, P.1    Vergnaud, P.2    Meunier, P.J.3
  • 32
    • 34147152190 scopus 로고    scopus 로고
    • Animal models for implant biomaterial research in bone: A review
    • 17334975 1:CAS:528:DC%2BD2sXjsFegu78%3D
    • Pearce AI, Richards RG, Milz S et al (2007) Animal models for implant biomaterial research in bone: a review. Eur Cell Mater 13:1-10
    • (2007) Eur Cell Mater , vol.13 , pp. 1-10
    • Pearce, A.I.1    Richards, R.G.2    Milz, S.3
  • 33
    • 33750542318 scopus 로고    scopus 로고
    • A comparison of pullout strength for pedicle screws of different designs: A study using tapped and untapped pilot holes
    • 17077722 10.1097/01.brs.0000244658.35865.59
    • Pfeiffer FM, Abernathie DL, Smith DE (2006) A comparison of pullout strength for pedicle screws of different designs: a study using tapped and untapped pilot holes. Spine 31:E867-E870
    • (2006) Spine , vol.31
    • Pfeiffer, F.M.1    Abernathie, D.L.2    Smith, D.E.3
  • 34
    • 84862872621 scopus 로고    scopus 로고
    • Experimental in vivo acute and chronic biomechanical and histomorphometrical comparison of self-drilling and self-tapping anterior cervical screws
    • 22173611 10.1007/s00586-011-2120-z
    • Porto MA, Silva P, Rosa R et al (2011) Experimental in vivo acute and chronic biomechanical and histomorphometrical comparison of self-drilling and self-tapping anterior cervical screws. Eur Spine J 21:956-963
    • (2011) Eur Spine J , vol.21 , pp. 956-963
    • Porto, M.A.1    Silva, P.2    Rosa, R.3
  • 35
    • 0035893914 scopus 로고    scopus 로고
    • Improved bone-screw interface with hydroxyapatite coating: An in vivo study of loaded pedicle screws in sheep
    • 10.1097/00007632-200112150-00008 1:STN:280:DC%2BD38%2Flt1KjtQ%3D%3D
    • Sanden B, Olerud C, Johansson C et al (2001) Improved bone-screw interface with hydroxyapatite coating: an in vivo study of loaded pedicle screws in sheep. Spine (Phila Pa 1976) 26:2673-2678
    • (2001) Spine (Phila Pa 1976) , vol.26 , pp. 2673-2678
    • Sanden, B.1    Olerud, C.2    Johansson, C.3
  • 36
    • 0016723088 scopus 로고
    • The holding power of orthopedic screws in vivo
    • 1139814 10.1097/00003086-197505000-00019
    • Schatzker J, Sanderson R, Murnaghan JP (1975) The holding power of orthopedic screws in vivo. Clin Orthop Relat Res 108:115-126
    • (1975) Clin Orthop Relat Res , vol.108 , pp. 115-126
    • Schatzker, J.1    Sanderson, R.2    Murnaghan, J.P.3
  • 37
    • 55849083483 scopus 로고    scopus 로고
    • Effect of micrometer-scale roughness of the surface of Ti6Al4 v pedicle screws in vitro and in vivo
    • 10.2106/JBJS.G.00499
    • Schwartz Z, Raz P, Zhao G et al (2008) Effect of micrometer-scale roughness of the surface of Ti6Al4 V pedicle screws in vitro and in vivo. J Bone Jt Surg Am 90:2485-2498
    • (2008) J Bone Jt Surg Am , vol.90 , pp. 2485-2498
    • Schwartz, Z.1    Raz, P.2    Zhao, G.3
  • 38
    • 33947692335 scopus 로고    scopus 로고
    • Biomechanical analysis of differing pedicle screw insertion angles
    • 10.1016/j.clinbiomech.2006.11.007
    • Sterba W, Kim DG, Fyhrie DP et al (2007) Biomechanical analysis of differing pedicle screw insertion angles. Clin Biomech 22:385-391
    • (2007) Clin Biomech , vol.22 , pp. 385-391
    • Sterba, W.1    Kim, D.G.2    Fyhrie, D.P.3
  • 39
    • 80051608193 scopus 로고    scopus 로고
    • Histomorphometric analysis of bone tissue repair in rabbits after insertion of titanium screws under different torque
    • 21808837 10.1590/S0102-86502011000400003
    • Togni F, Baras F, Ribas MO, Taha MO (2011) Histomorphometric analysis of bone tissue repair in rabbits after insertion of titanium screws under different torque. Acta Cir Bras 26:261-266
    • (2011) Acta Cir Bras , vol.26 , pp. 261-266
    • Togni, F.1    Baras, F.2    Ribas, M.O.3    Taha, M.O.4
  • 40
    • 0027426783 scopus 로고
    • Effect of screw diameter, insertion technique, and bone cement augmentation of pedicular screw fixation strength
    • 8222439
    • Wittenberg RH, Lee KS, Shea M et al (1993) Effect of screw diameter, insertion technique, and bone cement augmentation of pedicular screw fixation strength. Clin Orthop Relat Res 296:278-287
    • (1993) Clin Orthop Relat Res , vol.296 , pp. 278-287
    • Wittenberg, R.H.1    Lee, K.S.2    Shea, M.3
  • 41
    • 77950917813 scopus 로고    scopus 로고
    • Alendronate treatment improves bone-pedicle screw interface fixation in posterior lateral spine fusion: An experimental study in a porcine model
    • 19330331 10.1007/s00264-009-0759-4
    • Xue Q, Li H, Zou X et al (2010) Alendronate treatment improves bone-pedicle screw interface fixation in posterior lateral spine fusion: an experimental study in a porcine model. Int Orthop 34:447-451
    • (2010) Int Orthop , vol.34 , pp. 447-451
    • Xue, Q.1    Li, H.2    Zou, X.3
  • 42
    • 0027203876 scopus 로고
    • Pedicle screw pullout strength. Correlation with insertional torque
    • 10.1097/00007632-199309000-00016
    • Zideblick TA, Kunz DN, Cooke ME et al (1993) Pedicle screw pullout strength. Correlation with insertional torque. Spine 18:1673-1676
    • (1993) Spine , vol.18 , pp. 1673-1676
    • Zideblick, T.A.1    Kunz, D.N.2    Cooke, M.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.