메뉴 건너뛰기




Volumn 21, Issue 21, 1996, Pages 2429-2434

Insertional torque and pull-out strengths of conical and cylindrical pedicle screws in cadaveric bone

Author keywords

conical or cylindrical thread profile; insertion torque; pedicle screws; pull out strength

Indexed keywords

AGED; ARTICLE; BIOMECHANICS; BONE DENSITY; BONE MINERAL; BONE SCREW; BONE STRENGTH; HUMAN; HUMAN TISSUE; IMPLANT; NORMAL HUMAN; OSTEOPOROSIS; PRIORITY JOURNAL; TORQUE; VERTEBRA BODY;

EID: 0029825385     PISSN: 03622436     EISSN: None     Source Type: Journal    
DOI: 10.1097/00007632-199611010-00004     Document Type: Article
Times cited : (165)

References (14)
  • 1
    • 0013962144 scopus 로고
    • The relationship of bone strength and bone quantity in health, disease and aging
    • Bartley MH, Arnold JS, Haslam RK, Jee WS. The relationship of bone strength and bone quantity in health, disease and aging. J Gerontol 1966;21:517-21.
    • (1966) J Gerontol , vol.21 , pp. 517-521
    • Bartley, M.H.1    Arnold, J.S.2    Haslam, R.K.3    Jee, W.S.4
  • 3
    • 0026753723 scopus 로고
    • Screw fixation in the Human Sacrum; An in-vitro study of the biomechanics of fixation
    • Carlson GD, Abitbol JJ, Anderson DR, et al. Screw fixation in the Human Sacrum; An in-vitro study of the biomechanics of fixation. Spine 1992;17(Suppl):S196-203.
    • (1992) Spine , vol.17 , Issue.SUPPL.
    • Carlson, G.D.1    Abitbol, J.J.2    Anderson, D.R.3
  • 4
    • 0028258268 scopus 로고
    • Correlations between screw hole preparation, torque of insertions and pull-out strength for spinal screws
    • Daftari TK, Horton WC, Hutton WC. Correlations between screw hole preparation, torque of insertions and pull-out strength for spinal screws. J Spinal Disord 1994;7:139-45.
    • (1994) J Spinal Disord , vol.7 , pp. 139-145
    • Daftari, T.K.1    Horton, W.C.2    Hutton, W.C.3
  • 5
    • 0026777874 scopus 로고
    • Complications of lumbar spinal fusion with transpedicular instrumentation
    • Davne SH, Myers SL. Complications of lumbar spinal fusion with transpedicular instrumentation. Spine 1992;17 (Suppl):S184-9.
    • (1992) Spine , vol.17 , Issue.SUPPL.
    • Davne, S.H.1    Myers, S.L.2
  • 6
    • 0026439770 scopus 로고
    • Transpedicular screw-rod fixation of the lumbar spine: Operative technique and outcome in 104 cases
    • Dickman CA, Fessier RG, MacMillan M, Haid RW. Transpedicular screw-rod fixation of the lumbar spine: Operative technique and outcome in 104 cases. J Neurosurg 1992; 77:860-70.
    • (1992) J Neurosurg , vol.77 , pp. 860-870
    • Dickman, C.A.1    Fessier, R.G.2    MacMillan, M.3    Haid, R.W.4
  • 7
    • 0018143482 scopus 로고
    • The shear strength of trabecular bone from the femur, and some factors affecting the shear strength of the cement-bone interface
    • Halawa M, Lee AJC, Ling RSM, Vangala SS. The shear strength of trabecular bone from the femur, and some factors affecting the shear strength of the cement-bone interface. Arch Orthop Trauma Surg 1978;92:19-30.
    • (1978) Arch Orthop Trauma Surg , vol.92 , pp. 19-30
    • Halawa, M.1    Lee, A.J.C.2    Ling, R.S.M.3    Vangala, S.S.4
  • 9
    • 0004039764 scopus 로고
    • Clinical application on the thoracolumbar junction and the lumbar spine
    • Mears DC, ed. Baltimore: Williams and Wilkins
    • Magerl F. Clinical application on the thoracolumbar junction and the lumbar spine. In: Mears DC, ed. External Skeletal Fixation. Baltimore: Williams and Wilkins, 1983:553-75.
    • (1983) External Skeletal Fixation , pp. 553-575
    • Magerl, F.1
  • 10
    • 0024510133 scopus 로고
    • Anatomic analysis of pedicle cortical and cancellous diameter as related to screw size
    • Misenhimer GR, Peek RD, Wiltse LL, Rothman SLG, Widell EH Jr. Anatomic analysis of pedicle cortical and cancellous diameter as related to screw size. Spine 1989;14:367-72.
    • (1989) Spine , vol.14 , pp. 367-372
    • Misenhimer, G.R.1    Peek, R.D.2    Wiltse, L.L.3    Rothman, S.L.G.4    Widell Jr., E.H.5
  • 11
    • 0027252714 scopus 로고
    • CT Analysis of pedicles and screw tracts after implant removal in thoracolumbar fractures
    • Sjöström L, Jacobsson O, Karlström G, Pech P, Rauschning W. CT Analysis of pedicles and screw tracts after implant removal in thoracolumbar fractures. J Spinal Disord 1993;6: 225-31.
    • (1993) J Spinal Disord , vol.6 , pp. 225-231
    • Sjöström, L.1    Jacobsson, O.2    Karlström, G.3    Pech, P.4    Rauschning, W.5
  • 12
    • 0027344944 scopus 로고
    • Biomechanical testing of a new design for Schanz pedicle screws
    • Willet K, Hearn TC, Cuncins AV. Biomechanical testing of a new design for Schanz pedicle screws. J Orthop Trauma 1993;7:375-80.
    • (1993) J Orthop Trauma , vol.7 , pp. 375-380
    • Willet, K.1    Hearn, T.C.2    Cuncins, A.V.3
  • 13
    • 0026505213 scopus 로고
    • Mechanical stability of the pedicle screw fixation systems for the lumbar spine
    • Yamagata M, Kitahara H, Minami S, et al. Mechanical stability of the pedicle screw fixation systems for the lumbar spine. Spine 1992;17(Suppl):S51-4.
    • (1992) Spine , vol.17 , Issue.SUPPL.
    • Yamagata, M.1    Kitahara, H.2    Minami, S.3
  • 14
    • 0027203876 scopus 로고
    • Pedicle screw pull-out strength - Correlation with insertional torque
    • Zdeblick TA, Kunz DN, Cooke ME, McCabe R. Pedicle screw pull-out strength - Correlation with insertional torque. Spine 1993;18(12):1673-6.
    • (1993) Spine , vol.18 , Issue.12 , pp. 1673-1676
    • Zdeblick, T.A.1    Kunz, D.N.2    Cooke, M.E.3    McCabe, R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.