메뉴 건너뛰기




Volumn 21, Issue 5, 2012, Pages 956-963

Experimental in vivo acute and chronic biomechanical and histomorphometrical comparison of self-drilling and self-tapping anterior cervical screws

Author keywords

Biomechanics; Bone screws; Histology; Osseointegration; Spine

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL TISSUE; ARTICLE; BIOMECHANICS; BONE DENSITY; BONE SCREW; CERVICAL SPINE; IN VIVO STUDY; MALE; MORPHOMETRICS; NONHUMAN; PRIORITY JOURNAL; PULL OUT STRENGTH; SELF DRILLING SCREW; SELF TAPPING SCREW; STRENGTH; TORQUE;

EID: 84862872621     PISSN: 09406719     EISSN: 14320932     Source Type: Journal    
DOI: 10.1007/s00586-011-2120-z     Document Type: Article
Times cited : (10)

References (38)
  • 1
    • 0025975902 scopus 로고
    • Treatment of cervical spine injuries with anterior plating. Indications, techniques, and results
    • Aebi M, Zuber K, Marchesi D (1991) Treatment of cervical spine injuries with anterior plating. Indications, techniques, and results. Spine (Phila Pa 1976) 16:S38-S45
    • (1991) Spine (Phila Pa 1976) , vol.16
    • Aebi, M.1    Zuber, K.2    Marchesi, D.3
  • 2
    • 0017932324 scopus 로고
    • Mandibular oste-osynthesis by miniature screwed plates via a buccal approach
    • Champy M, Lodde JP, Schmitt R et al (1978) Mandibular oste-osynthesis by miniature screwed plates via a buccal approach. J Maxillofac Surg 6:14-21
    • (1978) J Maxillofac Surg , vol.6 , pp. 14-21
    • Champy, M.1    Lodde, J.P.2    Schmitt, R.3
  • 4
    • 0026409596 scopus 로고
    • Doseeffects on ewe bone remodeling of short-term sodium fluoride adminis-tration\-a histomorphometric and biochemical study
    • ChavassieuxP,PastoureauP,BoivinGetal(1991) Doseeffects on ewe bone remodeling of short-term sodium fluoride adminis-tration\-a histomorphometric and biochemical study. Bone 12: 421-427
    • (1991) Bone , vol.12 , pp. 421-427
    • Chavassieux, P.1    Pastoureau, P.2    Boivin, G.3
  • 6
    • 0033197576 scopus 로고    scopus 로고
    • New segmental long bone defect model in sheep: Quantitative analysis ofhealing with dual energy X-ray absorptiometry
    • den Boer FC, Patka P, Bakker FC et al (1999) New segmental long bone defect model in sheep: quantitative analysis ofhealing with dual energy X-ray absorptiometry. J Orthop Res 17:654-660
    • (1999) J Orthop Res , vol.17 , pp. 654-660
    • Den Boer, F.C.1    Patka, P.2    Bakker, F.C.3
  • 7
    • 0028318701 scopus 로고
    • Analysis of seating and fracturing torque of bicortical screws
    • Ellis JA Jr, Laskin DM (1994) Analysis of seating and fracturing torque of bicortical screws. J Oral Maxillofac Surg 52:483-486
    • (1994) J Oral Maxillofac Surg , vol.52 , pp. 483-486
    • Ellis Jr., J.A.1    Laskin, D.M.2
  • 8
    • 0032523022 scopus 로고    scopus 로고
    • Biomechanical evaluation of anterior cervical spine stabilization
    • DOI 10.1097/00007632-199804150-00009
    • Grubb MR, Currier BL, Shih JS et al (1998) Biomechanical evaluation of anterior cervical spine stabilization. Spine (Phila Pa 1976) 23:886-892 (Pubitemid 28188916)
    • (1998) Spine , vol.23 , Issue.8 , pp. 886-892
    • Grubb, M.R.1    Currier, B.L.2    Shin, J.-S.3    Bonin, V.4    Grabowski, J.J.5    Chao, E.Y.S.6
  • 9
    • 0004974928 scopus 로고    scopus 로고
    • The Synthes 1.5 and 2.0 self-drilling screws indication in maxillofacial sur-gery
    • Guntermann J, Gellrich NC, Schramm A et al (1998) The Synthes 1.5 and 2.0 self-drilling screws indication in maxillofacial sur-gery. J Craniomaxillofac Surg 26:65
    • (1998) J Craniomaxillofac Surg , vol.26 , pp. 65
    • Guntermann, J.1    Gellrich, N.C.2    Schramm, A.3
  • 11
    • 0032733986 scopus 로고    scopus 로고
    • Clinical applications ofdrill free screws in maxillofacial surgery
    • Heidemann W, Gerlach KL (1999) Clinical applications ofdrill free screws in maxillofacial surgery. J Craniomaxillofac Surg 27:252-255
    • (1999) J Craniomaxillofac Surg , vol.27 , pp. 252-255
    • Heidemann, W.1    Gerlach, K.L.2
  • 13
    • 0035022398 scopus 로고    scopus 로고
    • Analysis of the osseous/metal interface of drill free screws and self-tapping screws
    • DOI 10.1054/jcms.2000.0179
    • Heidemann W, Terheyden H, Gerlach KL (2001) Analysis of the osseous/metal interface of drill free screws and self-tapping screws. J Craniomaxillofac Surg 29:69-74 (Pubitemid 32427948)
    • (2001) Journal of Cranio-Maxillofacial Surgery , vol.29 , Issue.2 , pp. 69-74
    • Heidemann, W.1    Terheyden, H.2    Louis Gerlach, K.3
  • 14
    • 0035235727 scopus 로고    scopus 로고
    • In vivo studies of screw-bone contact of drill-free screws and conventional self-tapping screws
    • Heidemann W, Terheyden H, Gerlach KL (2001) In vivo studies of screw-bone contact of drill-free screws and conventional self-tapping screws. Mund Kiefer Gesichtschir 5:17-21
    • (2001) Mund Kiefer Gesichtschir , vol.5 , pp. 17-21
    • Heidemann, W.1    Terheyden, H.2    Gerlach, K.L.3
  • 15
    • 0037228899 scopus 로고    scopus 로고
    • Factors affecting the pullout strength of self-drilling and self-tapping anterior cervical screws
    • DOI 10.1097/00007632-200301010-00004
    • Hitchon PW, Brenton MD, Coppes JK et al (2003) Factors affecting the pullout strength of self-drilling and self-tapping anterior cervical screws. Spine (Phila Pa 1976) 28:9-13 (Pubitemid 36070764)
    • (2003) Spine , vol.28 , Issue.1 , pp. 9-13
    • Hitchon, P.W.1    Brenton, M.D.2    Coppes, J.K.3    From, A.M.4    Torner, J.C.5
  • 16
    • 33750537850 scopus 로고    scopus 로고
    • Cervical pedicle screws vs. lateral mass screws: Uniplanar fatigue analysis and residual pullout strengths
    • DOI 10.1016/j.spinee.2006.03.019, PII S1529943006002841
    • Johnston TL, Karaikovic EE, Lautenschlager EP et al (2006) Cervical pedicle screws vs. lateral mass screws: uniplanar fatigue analysis and residual pullout strengths. Spine J 6:667-672 (Pubitemid 44667880)
    • (2006) Spine Journal , vol.6 , Issue.6 , pp. 667-672
    • Johnston, T.L.1    Karaikovic, E.E.2    Lautenschlager, E.P.3    Marcu, D.4
  • 17
    • 0036481792 scopus 로고    scopus 로고
    • Anterior cervical plating enhances arthrodesis after discectomy and fusion with cortical allograft
    • DOI 10.1097/00006123-200202000-00001
    • Kaiser MG, Haid RW Jr, Subach BR et al (2002) Anterior cer-vical plating enhances arthrodesis after discectomy and fusion with cortical allograft. Neurosurgery 50:229-236 (Pubitemid 41672579)
    • (2002) Neurosurgery , vol.50 , Issue.2 , pp. 229-236
    • Kaiser, M.G.1    Haid Jr., R.W.2    Subach, B.R.3    Barnes, B.4    Rodts Jr., G.E.5
  • 18
    • 0347753912 scopus 로고    scopus 로고
    • Biomechanical considerations of animal models used in tissue engineering of bone
    • DOI 10.1016/S0142-9612(03)00515-5
    • Liebschner MA (2004) Biomechanical considerations of animal models used in tissue engineering of bone. Biomaterials 25: 1697-1714 (Pubitemid 38091548)
    • (2004) Biomaterials , vol.25 , Issue.9 , pp. 1697-1714
    • Liebschner, M.A.K.1
  • 19
    • 0034182657 scopus 로고    scopus 로고
    • Comparative in vitro studies of self-boring and self-tapping screws. Histomorpholog-ical and physical-technical studies of bone layers]
    • Lohr J, Gellrich NC, Buscher P et al (2000) Comparative in vitro studies of self-boring and self-tapping screws. Histomorpholog-ical and physical-technical studies of bone layers]. Mund Kiefer Gesichtschir 4:159-163
    • (2000) Mund Kiefer Gesichtschir , vol.4 , pp. 159-163
    • Lohr, J.1    Gellrich, N.C.2    Buscher, P.3
  • 20
    • 54549100144 scopus 로고    scopus 로고
    • Biome-chanical comparison of four different miniscrew types for skeletal anchorage in the mandibulo-maxillary area
    • Mischkowski RA, Kneuertz P, Florvaag B et al (2008) Biome-chanical comparison of four different miniscrew types for skeletal anchorage in the mandibulo-maxillary area. Int J Oral Maxillofac Surg 37:948-954
    • (2008) Int J Oral Maxillofac Surg , vol.37 , pp. 948-954
    • Mischkowski, R.A.1    Kneuertz, P.2    Florvaag, B.3
  • 21
    • 0029147322 scopus 로고
    • The potential of sheep for the study of osteopenia: Current status and comparison with other animal models
    • Newman E, Turner AS, Wark JD (1995) The potential of sheep for the study of osteopenia: current status and comparison with other animal models. Bone 16:277S-284S
    • (1995) Bone , vol.16
    • Newman, E.1    Turner, A.S.2    Wark, J.D.3
  • 22
    • 0030454240 scopus 로고    scopus 로고
    • Comparison between single-screw and triangulated, double-screw fixation in anterior spine surgery: A biomechanical test
    • DOI 10.1097/00007632-199612010-00005
    • Ogon M, Haid C, Krismer M et al (1996) Comparison between single-screw and triangulated, double-screw fixation in anterior spine surgery. A biomechanical test. Spine (Phila Pa 1976) 21: 2728-2734 (Pubitemid 26427735)
    • (1996) Spine , vol.21 , Issue.23 , pp. 2728-2734
    • Ogon, M.1    Haid, C.2    Krismer, M.3    Sterzinger, W.4    Bauer, R.5
  • 24
    • 16644370372 scopus 로고    scopus 로고
    • History of instrumentation for stabilization of the subaxial cervical spine
    • Omeis I, DeMattia JA, Hillard VH et al (2004) History of instrumentation for stabilization of the subaxial cervical spine. Neurosurg Focus 16:E10
    • (2004) Neurosurg Focus , vol.16
    • Omeis, I.1    Demattia, J.A.2    Hillard, V.H.3
  • 25
    • 0000924262 scopus 로고
    • Effects of oophorectomy on biochemical and histological indices of bone turnover in ewes
    • abstract 477
    • Pastoureau P, Arlot M, Caulin F, Barlet J, Meunier P, Delmas P (1989) Effects of oophorectomy on biochemical and histological indices of bone turnover in ewes. J Bone Miner Res 4:S237, abstract 477
    • (1989) J Bone Miner Res , vol.4
    • Pastoureau, P.1    Arlot, M.2    Caulin, F.3    Barlet, J.4    Meunier, P.5    Delmas, P.6
  • 27
    • 0036035518 scopus 로고    scopus 로고
    • Screw fixation to the posterior cortical shell does not influence peak torque and pullout in anterior cervical plating
    • DOI 10.1007/s00586-002-0447-1
    • Pitzen T, Barbier D, Tintinger F et al (2002) Screw fixation to the posterior cortical shell does not influence peak torque and pullout in anterior cervical plating. Eur Spine J 11:494-499 (Pubitemid 35232020)
    • (2002) European Spine Journal , vol.11 , Issue.5 , pp. 494-499
    • Pitzen, T.1    Barbier, D.2    Tintinger, F.3    Steudel, W.4    Strowitzki, M.5
  • 28
    • 24344482104 scopus 로고    scopus 로고
    • The effect of end screw orientation on the stability of anterior instrumentation in cyclic lateral bending
    • DOI 10.1016/j.spinee.2005.03.014, PII S1529943005001476
    • Rodriguez-Olaverri JC, Hasharoni A, DeWal H et al (2005) The effect of end screw orientation on the stability of anterior instrumentation in cyclic lateral bending. Spine J 5:554-557 (Pubitemid 41258625)
    • (2005) Spine Journal , vol.5 , Issue.5 , pp. 554-557
    • Rodriguez-Olaverri, J.C.1    Hasharoni, A.2    DeWal, H.3    Nuzzo, R.M.4    Kummer, F.J.5    Errico, T.J.6
  • 29
    • 0031044771 scopus 로고    scopus 로고
    • Comparative pull-out strength of tapped and untapped pilot holes for bicortical anterior cervical screws
    • DOI 10.1097/00007632-199701150-00007
    • Ronderos JF, Jacobowitz R, Sonntag VK et al (1997) Compara-tive pull-out strength of tapped and untapped pilot holes for bicortical anterior cervical screws. Spine (Phila Pa 1976) 22: 167-170 (Pubitemid 27081632)
    • (1997) Spine , vol.22 , Issue.2 , pp. 167-170
    • Ronderos, J.F.1    Jacobowitz, R.2    Sonntag, V.K.H.3    Crawford, N.R.4    Dickman, C.A.5
  • 30
    • 0025801025 scopus 로고
    • Triangulation of pedicular instrumentation. A biomechanical analysis
    • Ruland CM, McAfee PC, Warden KE et al (1991) Triangulation of pedicular instrumentation. A biomechanical analysis. Spine (Phila Pa 1976) 16:S270-S276
    • (1991) Spine (Phila Pa 1976) , vol.16
    • Ruland, C.M.1    McAfee, P.C.2    Warden, K.E.3
  • 31
    • 0029101673 scopus 로고
    • Biomechanical analysis of bone mineral density, insertion technique, screw tor-que, and holding strength of anterior cervical plate screws
    • Ryken TC, Clausen JD, Traynelis VC et al (1995) Biomechanical analysis of bone mineral density, insertion technique, screw tor-que, and holding strength of anterior cervical plate screws. J Neurosurg 83:325-329
    • (1995) J Neurosurg , vol.83 , pp. 325-329
    • Ryken, T.C.1    Clausen, J.D.2    Traynelis, V.C.3
  • 32
    • 0029165033 scopus 로고
    • Assess-ment of unicortical and bicortical fixation in a quasistatic cadaveric model. Role of bone mineral density and screw torque
    • Ryken TC, Goel VK, Clausen JD, Traynelis VC (1995) Assess-ment of unicortical and bicortical fixation in a quasistatic cadaveric model. Role of bone mineral density and screw torque. Spine (Phila Pa 1976) 20:1861-1867
    • (1995) Spine (Phila Pa 1976) , vol.20 , pp. 1861-1867
    • Ryken, T.C.1    Goel, V.K.2    Clausen, J.D.3    Traynelis, V.C.4
  • 34
    • 0004926961 scopus 로고    scopus 로고
    • Selfdrilling screws: Clinical experiences in cranio- and maxillofacial surgery
    • Schimming R, Gutwald R, Gellrich N et al (1999) Selfdrilling screws: clinical experiences in cranio- and maxillofacial surgery. Int J Oral Maxillofac Surg 28:26
    • (1999) Int J Oral Maxillofac Surg , vol.28 , pp. 26
    • Schimming, R.1    Gutwald, R.2    Gellrich, N.3
  • 35
    • 64049115744 scopus 로고    scopus 로고
    • A new stand-alone cervical anterior interbody fusion device: Biomechanical comparison with established anterior cervical fixation devices
    • Scholz M, Reyes PM, Schleicher P et al (2009) A new stand-alone cervical anterior interbody fusion device: biomechanical comparison with established anterior cervical fixation devices. Spine (Phila Pa 1976) 34:156-160
    • (2009) Spine (Phila Pa 1976) , vol.34 , pp. 156-160
    • Scholz, M.1    Reyes, P.M.2    Schleicher, P.3
  • 36
    • 0036184391 scopus 로고    scopus 로고
    • AO self-drilling and self-tapping screws in rat calvarial bone: An ultrastructural study of the implant interface
    • DOI 10.1053/joms.2002.30585
    • Sowden D, Schmitz JP (2002) AO self-drilling and self-tapping screws in rat calvarial bone: an ultrastructural study of the implant interface. J Oral Maxillofac Surg 60:294-299 (Pubitemid 34184530)
    • (2002) Journal of Oral and Maxillofacial Surgery , vol.60 , Issue.3 , pp. 294-299
    • Sowden, D.1    Schmitz, J.P.2
  • 37
    • 70349576506 scopus 로고    scopus 로고
    • Comparison of self-tapping and self-drilling orthodontic mini-implants: An animal study of insertion torque and displacement under lateral loading
    • Su YY, Wilmes B, Honscheid R, Drescher D (2009) Comparison of self-tapping and self-drilling orthodontic mini-implants: an animal study of insertion torque and displacement under lateral loading. Int J Oral Maxillofac Implants 24:404-411
    • (2009) Int J Oral Maxillofac Implants , vol.24 , pp. 404-411
    • Su, Y.Y.1    Wilmes, B.2    Honscheid, R.3    Drescher, D.4
  • 38
    • 53249107200 scopus 로고    scopus 로고
    • Biomechanical and histo-morphometric analyses of the osseointegration of microscrews with different surgical techniques in beagle dogs
    • Wu X, Deng F, Wang Z et al (2008) Biomechanical and histo-morphometric analyses of the osseointegration of microscrews with different surgical techniques in beagle dogs. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 106:644-650
    • (2008) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.106 , pp. 644-650
    • Wu, X.1    Deng, F.2    Wang, Z.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.