-
1
-
-
0027484342
-
Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members
-
Essens S., Sachs B., and Dreyzin V. Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members. Spine 18 (1993) 2231-2239
-
(1993)
Spine
, vol.18
, pp. 2231-2239
-
-
Essens, S.1
Sachs, B.2
Dreyzin, V.3
-
2
-
-
33646459226
-
Surgical complications of posterior lumbar interbody fusion with total facetectomy in 251 patients
-
Okuda S., Miyauchi A., Oda T., Haku T., Yamamoto T., and Iwasaki M. Surgical complications of posterior lumbar interbody fusion with total facetectomy in 251 patients. J Neurosurg (Spine) 4 (2006) 304-309
-
(2006)
J Neurosurg (Spine)
, vol.4
, pp. 304-309
-
-
Okuda, S.1
Miyauchi, A.2
Oda, T.3
Haku, T.4
Yamamoto, T.5
Iwasaki, M.6
-
3
-
-
0038241882
-
Complications and problems related to pedicle screw fixation of the spine
-
Katonis P., Christoforakis J., Aligizakis A.C., Papadopoulos C., Sapkas G., and Hadjipavlou A. Complications and problems related to pedicle screw fixation of the spine. Clin Orthop Relat Res 411 (2003) 86-94
-
(2003)
Clin Orthop Relat Res
, vol.411
, pp. 86-94
-
-
Katonis, P.1
Christoforakis, J.2
Aligizakis, A.C.3
Papadopoulos, C.4
Sapkas, G.5
Hadjipavlou, A.6
-
4
-
-
43549123081
-
Loads on a telemeterized vertebral body replacement measured in two patients
-
Rohlmann A., Graichen F., Kayser R., Bender A., and Bergmann G. Loads on a telemeterized vertebral body replacement measured in two patients. Spine 33 (2008) 1170-1179
-
(2008)
Spine
, vol.33
, pp. 1170-1179
-
-
Rohlmann, A.1
Graichen, F.2
Kayser, R.3
Bender, A.4
Bergmann, G.5
-
6
-
-
0007807096
-
Actual holding power of various screws in bone
-
Lyon W.F., Cochran J.R., and Smith L. Actual holding power of various screws in bone. Ann Surg 114 (1941) 376-384
-
(1941)
Ann Surg
, vol.114
, pp. 376-384
-
-
Lyon, W.F.1
Cochran, J.R.2
Smith, L.3
-
7
-
-
0030221045
-
Factors affecting the pullout strength of cancellous bone screws
-
Chapman J., Harrington R., Lee K., Anderson P., Tencer A., and Kowalski D. Factors affecting the pullout strength of cancellous bone screws. J Biomech Eng 118 (1996) 391-398
-
(1996)
J Biomech Eng
, vol.118
, pp. 391-398
-
-
Chapman, J.1
Harrington, R.2
Lee, K.3
Anderson, P.4
Tencer, A.5
Kowalski, D.6
-
8
-
-
0030345576
-
Cancellous bone screw thread design and holding power
-
Asnis S., Ernberg J., Bostrom M., Wright T., Harrington R., Tencer A., et al. Cancellous bone screw thread design and holding power. J Orthop Trauma 10 (1996) 462-469
-
(1996)
J Orthop Trauma
, vol.10
, pp. 462-469
-
-
Asnis, S.1
Ernberg, J.2
Bostrom, M.3
Wright, T.4
Harrington, R.5
Tencer, A.6
-
10
-
-
0000781654
-
A study of some factors which affect the strength of screws and their insertion and holding power in bone
-
Ansell H., and Scales J. A study of some factors which affect the strength of screws and their insertion and holding power in bone. J Biomechanics 1 (1968) 279-302
-
(1968)
J Biomechanics
, vol.1
, pp. 279-302
-
-
Ansell, H.1
Scales, J.2
-
11
-
-
0025034937
-
Optimizing bone screw pullout force
-
DeCoster T.A., Heetderks D.B., Downey D.J., Ferries J.S., and Jones W. Optimizing bone screw pullout force. J Orthop Trauma 4 2 (1990) 169-174
-
(1990)
J Orthop Trauma
, vol.4
, Issue.2
, pp. 169-174
-
-
DeCoster, T.A.1
Heetderks, D.B.2
Downey, D.J.3
Ferries, J.S.4
Jones, W.5
-
13
-
-
0030873579
-
Pullout strength of cannulated and noncannulated cancellous bone screws
-
Thompson J., Benjamin J., and Szivek J. Pullout strength of cannulated and noncannulated cancellous bone screws. Clin Orthop Relat Res 341 (1997) 241-249
-
(1997)
Clin Orthop Relat Res
, vol.341
, pp. 241-249
-
-
Thompson, J.1
Benjamin, J.2
Szivek, J.3
-
14
-
-
0015378503
-
The mechanical properties of surgical bone screws and some aspects of insertion practice
-
Hughes A.N., and Jordan B.A. The mechanical properties of surgical bone screws and some aspects of insertion practice. Injury 4 (1972) 25-38
-
(1972)
Injury
, vol.4
, pp. 25-38
-
-
Hughes, A.N.1
Jordan, B.A.2
-
15
-
-
0022628372
-
Biomechanical study of intrapedicular screw fixation in the lumbosacral spine
-
Zindrick M., Wiltse L., Widell E., Thomas J., Holland R., Field T., et al. Biomechanical study of intrapedicular screw fixation in the lumbosacral spine. Clin Orthop Relat Res 203 (1986) 99-112
-
(1986)
Clin Orthop Relat Res
, vol.203
, pp. 99-112
-
-
Zindrick, M.1
Wiltse, L.2
Widell, E.3
Thomas, J.4
Holland, R.5
Field, T.6
-
16
-
-
0027351322
-
The holding strength of cannulated screws compared with solid screws in cortical and cancelous bone
-
Leggon R., Lindsey R.W., Doherty B.J., Alexander J., and Noble P. The holding strength of cannulated screws compared with solid screws in cortical and cancelous bone. J Orthop Trauma 7 (1993) 450-457
-
(1993)
J Orthop Trauma
, vol.7
, pp. 450-457
-
-
Leggon, R.1
Lindsey, R.W.2
Doherty, B.J.3
Alexander, J.4
Noble, P.5
-
17
-
-
0035689180
-
Fine thread versus coarse thread. A comparison of the maximum holding power Injury
-
Gausepohl T., Möhring R., Pennig D., and Koebke J. Fine thread versus coarse thread. A comparison of the maximum holding power Injury. Int J Care Injured 32 (2001) SD1-SD7
-
(2001)
Int J Care Injured
, vol.32
-
-
Gausepohl, T.1
Möhring, R.2
Pennig, D.3
Koebke, J.4
-
18
-
-
46749109567
-
Influence of thread design on pedicle screw fixation: laboratory investigation
-
Krenn M., Piotrowski W., Penzkofer R., and Augat P. Influence of thread design on pedicle screw fixation: laboratory investigation. J Neurosurg (Spine) 9 (2008) 90-95
-
(2008)
J Neurosurg (Spine)
, vol.9
, pp. 90-95
-
-
Krenn, M.1
Piotrowski, W.2
Penzkofer, R.3
Augat, P.4
-
19
-
-
1442324443
-
Investigation of fixation screw pull-out strength on human spine
-
Zhang Q.H., Tan S.H., and Chou S.M. Investigation of fixation screw pull-out strength on human spine. J Biomechanics 37 (2004) 479-485
-
(2004)
J Biomechanics
, vol.37
, pp. 479-485
-
-
Zhang, Q.H.1
Tan, S.H.2
Chou, S.M.3
-
20
-
-
33744982619
-
Effects of bone materials on the screw pull-out strength in human spine
-
Zhang Q.H., Tan S.H., and Chou S.M. Effects of bone materials on the screw pull-out strength in human spine. Med Eng Phys 28 (2006) 795-801
-
(2006)
Med Eng Phys
, vol.28
, pp. 795-801
-
-
Zhang, Q.H.1
Tan, S.H.2
Chou, S.M.3
-
21
-
-
0036269098
-
Optimizing the biomechanical compatibility of orthopaedic screws for bone fracture fixation
-
Gefen A. Optimizing the biomechanical compatibility of orthopaedic screws for bone fracture fixation. Med Eng Phys 24 (2002) 337-347
-
(2002)
Med Eng Phys
, vol.24
, pp. 337-347
-
-
Gefen, A.1
-
22
-
-
21844480606
-
Increase of pullout strength of spinal pedicle screws with conical core: biomechanical tests and finite element analyses
-
Hsu C.C., Chao C.K., Wang J.L., Hou S.M., Tsai Y.T., and Lin J. Increase of pullout strength of spinal pedicle screws with conical core: biomechanical tests and finite element analyses. J Orthop Res 23 (2005) 788-794
-
(2005)
J Orthop Res
, vol.23
, pp. 788-794
-
-
Hsu, C.C.1
Chao, C.K.2
Wang, J.L.3
Hou, S.M.4
Tsai, Y.T.5
Lin, J.6
-
23
-
-
41949110636
-
Increasing bending strength and pullout strength in conical pedicle screws: biomechanical tests and finite element analyses
-
Chao C.K., Hsu C.C., Wang J.L., and Lin J. Increasing bending strength and pullout strength in conical pedicle screws: biomechanical tests and finite element analyses. J Spinal Disord Tech 21 (2008) 130-138
-
(2008)
J Spinal Disord Tech
, vol.21
, pp. 130-138
-
-
Chao, C.K.1
Hsu, C.C.2
Wang, J.L.3
Lin, J.4
-
24
-
-
70349768310
-
The influence of the "penetration-" and the "filling-ratios" on the pull-out strength of transpedicular screws
-
Kourkoulis S.K., and Chatzistergos E.P. The influence of the "penetration-" and the "filling-ratios" on the pull-out strength of transpedicular screws. J Mechanics Med Biol 9 (2009) 283-300
-
(2009)
J Mechanics Med Biol
, vol.9
, pp. 283-300
-
-
Kourkoulis, S.K.1
Chatzistergos, E.P.2
-
25
-
-
0032170254
-
Titanium alloys in total joint replacement-a materials science perspective
-
Long M., and Rack H.J. Titanium alloys in total joint replacement-a materials science perspective. Biomaterials 19 (1998) 1621-1639
-
(1998)
Biomaterials
, vol.19
, pp. 1621-1639
-
-
Long, M.1
Rack, H.J.2
-
26
-
-
75749125031
-
Posterior lumbar spine: CD Horizon Legacy 5.5 Spinal System
-
Fessler R., Kim D., and Vaccaro A. (Eds), Thieme Medical Publishers Inc., NY
-
Dimar J., Glassman S., Puno R., Campbell M., and Johnson J. Posterior lumbar spine: CD Horizon Legacy 5.5 Spinal System. In: Fessler R., Kim D., and Vaccaro A. (Eds). Spinal instrumentation: surgical techniques (2005), Thieme Medical Publishers Inc., NY 850-855
-
(2005)
Spinal instrumentation: surgical techniques
, pp. 850-855
-
-
Dimar, J.1
Glassman, S.2
Puno, R.3
Campbell, M.4
Johnson, J.5
-
27
-
-
0035074055
-
Finite element interface models for the delamination analysis of laminated composites: mechanical and computational issues
-
Alfano G., and Crisfield M.A. Finite element interface models for the delamination analysis of laminated composites: mechanical and computational issues. Int J Numer Meth Eng 50 (2001) 1701-1736
-
(2001)
Int J Numer Meth Eng
, vol.50
, pp. 1701-1736
-
-
Alfano, G.1
Crisfield, M.A.2
-
28
-
-
75749120667
-
-
ANSYS, ANSYS Release 11.0 Documentation. Canonsburg, PA, USA: ANSYS Inc
-
ANSYS, ANSYS Release 11.0 Documentation. Canonsburg, PA, USA: ANSYS Inc.
-
-
-
-
29
-
-
75749140972
-
Working strength of bolts
-
Ryffel H.H. (Ed), Industrial Press, New York
-
Oberg E., Jones F.D., and Horton H.L. Working strength of bolts. In: Ryffel H.H. (Ed). Machinery's handbook (2004), Industrial Press, New York 1509-1511
-
(2004)
Machinery's handbook
, pp. 1509-1511
-
-
Oberg, E.1
Jones, F.D.2
Horton, H.L.3
-
30
-
-
0027664803
-
Stress analysis of drillstring threaded connections using the finite element method
-
Tafrreshi A., and Dover W.D. Stress analysis of drillstring threaded connections using the finite element method. Int J Fatigue 15 (1993) 429-438
-
(1993)
Int J Fatigue
, vol.15
, pp. 429-438
-
-
Tafrreshi, A.1
Dover, W.D.2
-
31
-
-
42649086143
-
Restaurierung antiker Tempel: Experimentelle Untersuchungen zum Ausziehverhalten von Verankerungen im Marmor
-
Kourkoulis S.K., Papanicolopulos S.A., Marinelli A., and Vayas I. Restaurierung antiker Tempel: Experimentelle Untersuchungen zum Ausziehverhalten von Verankerungen im Marmor. Bautechnik 85 (2008) 109-119
-
(2008)
Bautechnik
, vol.85
, pp. 109-119
-
-
Kourkoulis, S.K.1
Papanicolopulos, S.A.2
Marinelli, A.3
Vayas, I.4
-
32
-
-
75749103795
-
The influence of the insertion technique on the pullout force of pedicle screws: An experimental study
-
in press
-
Chatzistergos EP, Sapkas G, Kourkoulis SK. The influence of the insertion technique on the pullout force of pedicle screws: an experimental study. Spine; in press.
-
Spine
-
-
Chatzistergos, E.P.1
Sapkas, G.2
Kourkoulis, S.K.3
-
33
-
-
43449118717
-
Pullout strength and load to failure properties of self-tapping cortical screws in synthetic and cadaveric environments representative of healthy and osteoporotic bone
-
Schoenfeld A., Battula S., Sahai V., Vrabec G., Corman S., Burton L., et al. Pullout strength and load to failure properties of self-tapping cortical screws in synthetic and cadaveric environments representative of healthy and osteoporotic bone. J Trauma 64 (2008) 1302-1307
-
(2008)
J Trauma
, vol.64
, pp. 1302-1307
-
-
Schoenfeld, A.1
Battula, S.2
Sahai, V.3
Vrabec, G.4
Corman, S.5
Burton, L.6
|