메뉴 건너뛰기




Volumn 53, Issue , 2014, Pages 159-173

Multi-objective design optimization of functionally graded material for the femoral component of a total knee replacement

Author keywords

Aseptic loosening; Design of experiments; Knee prosthesis; Material selection and design; Multi objective decision making

Indexed keywords

ARTHROPLASTY; BIOLOGICAL MATERIALS; CHROMIUM ALLOYS; DESIGN; DESIGN OF EXPERIMENTS; FUNCTIONS; IMPLANTS (SURGICAL); JOINTS (ANATOMY); KNEE PROSTHESES; LARGE SCALE SYSTEMS; OPTIMAL SYSTEMS; OPTIMIZATION;

EID: 84881017583     PISSN: 02641275     EISSN: 18734197     Source Type: Journal    
DOI: 10.1016/j.matdes.2013.06.050     Document Type: Article
Times cited : (68)

References (34)
  • 1
    • 0037667694 scopus 로고    scopus 로고
    • Optimization of laminates fracture toughness using design of experiments and response surface
    • Pelegri A.A., Tekkam A. Optimization of laminates fracture toughness using design of experiments and response surface. J Compos Mater 2003, 37(7):579-596.
    • (2003) J Compos Mater , vol.37 , Issue.7 , pp. 579-596
    • Pelegri, A.A.1    Tekkam, A.2
  • 2
    • 69049084470 scopus 로고    scopus 로고
    • Design optimization of functionally graded dental implant for bone remodeling
    • Lin D., et al. Design optimization of functionally graded dental implant for bone remodeling. Compos B Eng 2009, 40(7):668-675.
    • (2009) Compos B Eng , vol.40 , Issue.7 , pp. 668-675
    • Lin, D.1
  • 3
    • 79960563280 scopus 로고    scopus 로고
    • Optimum gradient material for a functionally graded dental implant using metaheuristic algorithms
    • Sadollah A., Bahreininejad A. Optimum gradient material for a functionally graded dental implant using metaheuristic algorithms. J Mech Behav Biomed Mater 2011, 4(7):1384-1395.
    • (2011) J Mech Behav Biomed Mater , vol.4 , Issue.7 , pp. 1384-1395
    • Sadollah, A.1    Bahreininejad, A.2
  • 4
    • 33748038792 scopus 로고    scopus 로고
    • Development of cementless metal-backed acetabular cup prosthesis using functionally graded material
    • Hedia H., et al. Development of cementless metal-backed acetabular cup prosthesis using functionally graded material. Int J Mech Mater Des 2005, 2(3):259-267.
    • (2005) Int J Mech Mater Des , vol.2 , Issue.3 , pp. 259-267
    • Hedia, H.1
  • 5
    • 84862929672 scopus 로고    scopus 로고
    • Effects of materials of cementless femoral stem on the functional adaptation of bone
    • Gong H., et al. Effects of materials of cementless femoral stem on the functional adaptation of bone. J Bionic Eng 2012, 9(1):66-74.
    • (2012) J Bionic Eng , vol.9 , Issue.1 , pp. 66-74
    • Gong, H.1
  • 6
    • 80054760720 scopus 로고    scopus 로고
    • A comparative study of the performance of metallic and FGM tibia tray components in total knee replacement joints
    • Enab T.A. A comparative study of the performance of metallic and FGM tibia tray components in total knee replacement joints. Comput Mater Sci 2011, 53(1):94-100.
    • (2011) Comput Mater Sci , vol.53 , Issue.1 , pp. 94-100
    • Enab, T.A.1
  • 7
    • 84865338528 scopus 로고    scopus 로고
    • Aseptic loosening of femoral components-materials engineering and design considerations
    • Bahraminasab M., et al. Aseptic loosening of femoral components-materials engineering and design considerations. Mater Des 2013, 44:155-163.
    • (2013) Mater Des , vol.44 , pp. 155-163
    • Bahraminasab, M.1
  • 8
    • 84866271506 scopus 로고    scopus 로고
    • Material selection in the design of the tibia tray component of cemented artificial knee using finite element method
    • Enab T.A., Bondok N.E. Material selection in the design of the tibia tray component of cemented artificial knee using finite element method. Mater Des 2013, 44:454-460.
    • (2013) Mater Des , vol.44 , pp. 454-460
    • Enab, T.A.1    Bondok, N.E.2
  • 9
    • 46749119877 scopus 로고    scopus 로고
    • Practical applications of design of experiments in the field of engineering: a bibliographical review
    • Ilzarbe L., et al. Practical applications of design of experiments in the field of engineering: a bibliographical review. Qual Relia Eng Int 2008, 24(4):417-428.
    • (2008) Qual Relia Eng Int , vol.24 , Issue.4 , pp. 417-428
    • Ilzarbe, L.1
  • 10
    • 0242490336 scopus 로고    scopus 로고
    • Reduction of thermal stresses by developing two-dimensional functionally graded materials
    • Nemat-Alla M. Reduction of thermal stresses by developing two-dimensional functionally graded materials. Int J Solids Struct 2003, 40(26):7339-7356.
    • (2003) Int J Solids Struct , vol.40 , Issue.26 , pp. 7339-7356
    • Nemat-Alla, M.1
  • 11
    • 78651083431 scopus 로고    scopus 로고
    • Porous metals in orthopedic applications - a review. Poröse Metalle in orthopädischen Anwendungen - Eine Übersicht
    • Levine B., Fabi D. Porous metals in orthopedic applications - a review. Poröse Metalle in orthopädischen Anwendungen - Eine Übersicht. Materialwiss Werkstofftech 2010, 41(12):1001-1010.
    • (2010) Materialwiss Werkstofftech , vol.41 , Issue.12 , pp. 1001-1010
    • Levine, B.1    Fabi, D.2
  • 12
    • 80051876620 scopus 로고    scopus 로고
    • Finite element analysis of the effect of shape memory alloy on the stress distribution and contact pressure in total knee replacement
    • Bahraminasab M., et al. Finite element analysis of the effect of shape memory alloy on the stress distribution and contact pressure in total knee replacement. Trends Biomater Artif Organs 2011, 25(3):95-100.
    • (2011) Trends Biomater Artif Organs , vol.25 , Issue.3 , pp. 95-100
    • Bahraminasab, M.1
  • 13
    • 0036137726 scopus 로고    scopus 로고
    • Simulation of a knee joint replacement during a gait cycle using explicit finite element analysis
    • Godest A.C., et al. Simulation of a knee joint replacement during a gait cycle using explicit finite element analysis. J Biomech 2002, 35(2):267-275.
    • (2002) J Biomech , vol.35 , Issue.2 , pp. 267-275
    • Godest, A.C.1
  • 14
    • 4644332288 scopus 로고    scopus 로고
    • Wear behavior of UHMWPE sliding on artificial hip arthroplasty materials
    • Cho H.J., et al. Wear behavior of UHMWPE sliding on artificial hip arthroplasty materials. Mater Chem Phys 2004, 88(1):9-16.
    • (2004) Mater Chem Phys , vol.88 , Issue.1 , pp. 9-16
    • Cho, H.J.1
  • 15
    • 0026821443 scopus 로고
    • Experimental determination of friction characteristics at the trabecular bone/porousâ€[U+06AF]coated metal interface in cementless implants
    • Shirazi-Adl A., Dammak M., Paiement G. Experimental determination of friction characteristics at the trabecular bone/porousâ€[U+06AF]coated metal interface in cementless implants. J Biomed Mater Res 1993, 27(2):167-175.
    • (1993) J Biomed Mater Res , vol.27 , Issue.2 , pp. 167-175
    • Shirazi-Adl, A.1    Dammak, M.2    Paiement, G.3
  • 17
    • 79251605247 scopus 로고    scopus 로고
    • Numerical investigation of the effect of porous titanium femoral prosthesis on bone remodeling
    • Yan W., Berthe J., Wen C. Numerical investigation of the effect of porous titanium femoral prosthesis on bone remodeling. Mater Des 2011, 32(4):1776-1782.
    • (2011) Mater Des , vol.32 , Issue.4 , pp. 1776-1782
    • Yan, W.1    Berthe, J.2    Wen, C.3
  • 18
    • 10444255467 scopus 로고    scopus 로고
    • Explicit finite element modeling of total knee replacement mechanics
    • Halloran J.P., Petrella A.J., Rullkoetter P.J. Explicit finite element modeling of total knee replacement mechanics. J Biomech 2005, 38(2):323-331.
    • (2005) J Biomech , vol.38 , Issue.2 , pp. 323-331
    • Halloran, J.P.1    Petrella, A.J.2    Rullkoetter, P.J.3
  • 19
    • 0036853009 scopus 로고    scopus 로고
    • Effect of Fuji pressure sensitive film on actual contact characteristics of artificial tibiofemoral joint
    • Liau J., et al. Effect of Fuji pressure sensitive film on actual contact characteristics of artificial tibiofemoral joint. Clin Biomech 2002, 17(9-10):698-704.
    • (2002) Clin Biomech , vol.17 , Issue.9-10 , pp. 698-704
    • Liau, J.1
  • 20
    • 0036152768 scopus 로고    scopus 로고
    • The effect of malalignment on stresses in polyethylene component of total knee prostheses - a finite element analysis
    • Liau J., et al. The effect of malalignment on stresses in polyethylene component of total knee prostheses - a finite element analysis. Clin Biomech 2002, 17(2):140-146.
    • (2002) Clin Biomech , vol.17 , Issue.2 , pp. 140-146
    • Liau, J.1
  • 21
    • 0035124771 scopus 로고    scopus 로고
    • The influence of inserting a Fuji pressure sensitive film between the tibiofemoral joint of knee prosthesis on actual contact characteristics
    • Liau J., et al. The influence of inserting a Fuji pressure sensitive film between the tibiofemoral joint of knee prosthesis on actual contact characteristics. Clin Biomech 2001, 16(2):160-166.
    • (2001) Clin Biomech , vol.16 , Issue.2 , pp. 160-166
    • Liau, J.1
  • 22
    • 78049486565 scopus 로고    scopus 로고
    • The biomechanics of a validated finite element model of stress shielding in a novel hybrid total knee replacement
    • Bougherara H., et al. The biomechanics of a validated finite element model of stress shielding in a novel hybrid total knee replacement. Proc Inst Mech Eng H: J Eng Med 2010, 224(10):1209-1219.
    • (2010) Proc Inst Mech Eng H: J Eng Med , vol.224 , Issue.10 , pp. 1209-1219
    • Bougherara, H.1
  • 24
    • 84864050510 scopus 로고    scopus 로고
    • Aseptic loosening of femoral components - a review of current and future trends in materials used
    • Bahraminasab M., et al. Aseptic loosening of femoral components - a review of current and future trends in materials used. Mater Des 2012, 42:459-470.
    • (2012) Mater Des , vol.42 , pp. 459-470
    • Bahraminasab, M.1
  • 25
    • 84863497566 scopus 로고    scopus 로고
    • A weighted metric method to optimize multi-response robust problems
    • Noorossana R., Ardakani M.K. A weighted metric method to optimize multi-response robust problems. J Ind Eng Int 2009, 5:10-19.
    • (2009) J Ind Eng Int , vol.5 , pp. 10-19
    • Noorossana, R.1    Ardakani, M.K.2
  • 26
    • 0023007566 scopus 로고
    • The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement
    • Bartel D., Bicknell V., Wright T. The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement. J Bone Joint Surg 1986, 68(7):1041-1051.
    • (1986) J Bone Joint Surg , vol.68 , Issue.7 , pp. 1041-1051
    • Bartel, D.1    Bicknell, V.2    Wright, T.3
  • 27
    • 0033104476 scopus 로고    scopus 로고
    • The conflicting requirements of laxity and conformity in total knee replacement
    • Sathasivam S., Walker P. The conflicting requirements of laxity and conformity in total knee replacement. J Biomech 1999, 32(3):239-247.
    • (1999) J Biomech , vol.32 , Issue.3 , pp. 239-247
    • Sathasivam, S.1    Walker, P.2
  • 28
    • 0035000279 scopus 로고    scopus 로고
    • Distal femoral bone mineral density after total knee arthroplasty: a comparison with general bone mineral density
    • Van Loon C.J.M., et al. Distal femoral bone mineral density after total knee arthroplasty: a comparison with general bone mineral density. Arch Orthop Trauma Surg 2001, 121(5):282-285.
    • (2001) Arch Orthop Trauma Surg , vol.121 , Issue.5 , pp. 282-285
    • Van Loon, C.J.M.1
  • 29
    • 0029802253 scopus 로고    scopus 로고
    • Decreased bone density of the distal femur after uncemented knee arthroplasty. A 1-year follow-up of 29 knees
    • Petersen M.M., et al. Decreased bone density of the distal femur after uncemented knee arthroplasty. A 1-year follow-up of 29 knees. Acta Orthop Scand 1996, 67(4):339-344.
    • (1996) Acta Orthop Scand , vol.67 , Issue.4 , pp. 339-344
    • Petersen, M.M.1
  • 30
    • 0033059331 scopus 로고    scopus 로고
    • Is bone density in the distal femur affected by use of cement and by femoral component design in total knee arthroplasty?
    • Seki T., et al. Is bone density in the distal femur affected by use of cement and by femoral component design in total knee arthroplasty?. J Orthop Sci 1999, 4(3):180-186.
    • (1999) J Orthop Sci , vol.4 , Issue.3 , pp. 180-186
    • Seki, T.1
  • 31
    • 77950689711 scopus 로고    scopus 로고
    • Analysis of boneâ€"prosthesis interface micromotion for cementless tibial prosthesis fixation and the influence of loading conditions
    • Chong D.Y., Hansen U.N., Amis A.A. Analysis of boneâ€"prosthesis interface micromotion for cementless tibial prosthesis fixation and the influence of loading conditions. J Biomech 2010, 43(6):1074-1080.
    • (2010) J Biomech , vol.43 , Issue.6 , pp. 1074-1080
    • Chong, D.Y.1    Hansen, U.N.2    Amis, A.A.3
  • 32
    • 65049087367 scopus 로고    scopus 로고
    • Three dimensional shape optimization of total knee replacements for reduced wear
    • Willing R., Kim I.Y. Three dimensional shape optimization of total knee replacements for reduced wear. Struct Multidiscip Optim 2009, 38(4):405-414.
    • (2009) Struct Multidiscip Optim , vol.38 , Issue.4 , pp. 405-414
    • Willing, R.1    Kim, I.Y.2
  • 33
    • 0019897146 scopus 로고
    • The wear characteristics of ultra high molecular weight polyethylene against a high density alumina ceramic under wet (distilled water) and dry conditions
    • Dowson D., Harding R.T. The wear characteristics of ultra high molecular weight polyethylene against a high density alumina ceramic under wet (distilled water) and dry conditions. Wear 1982, 75:313-331.
    • (1982) Wear , vol.75 , pp. 313-331
    • Dowson, D.1    Harding, R.T.2
  • 34
    • 0030345394 scopus 로고    scopus 로고
    • 3-Dimensional sliding/contact computational simulation of total hip wear
    • Maxian T.A., et al. 3-Dimensional sliding/contact computational simulation of total hip wear. Clin Orthop Relat Res 1996, 333:41-50.
    • (1996) Clin Orthop Relat Res , vol.333 , pp. 41-50
    • Maxian, T.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.