메뉴 건너뛰기




Volumn 40, Issue 7, 2009, Pages 668-675

Design optimization of functionally graded dental implant for bone remodeling

Author keywords

A. Ceramic matrix composites (CMCs); B. Mechanical properties; C. Finite element analysis (FEA); D. Sintering; Functionally graded material (FGM)

Indexed keywords

A. CERAMIC MATRIX COMPOSITES (CMCS); B. MECHANICAL PROPERTIES; BIOMECHANICAL CHARACTERISTICS; BONE REMODELING; C. FINITE ELEMENT ANALYSIS (FEA); COMPUTERIZED TOMOGRAPHY SCAN; CRITICAL ISSUES; D. SINTERING; DENTAL IMPLANTATIONS; DENTAL IMPLANTS; DESIGN OPTIMIZATION; FUNCTIONALLY GRADED; IMPLANT MATERIALS; KEY ISSUES; MULTI OBJECTIVE; OPTIMAL DESIGN; OSSEOINTEGRATION; RESPONSE SURFACE METHOD; SECTIONAL MODEL;

EID: 69049084470     PISSN: 13598368     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.compositesb.2009.04.015     Document Type: Article
Times cited : (128)

References (34)
  • 1
    • 25844483285 scopus 로고    scopus 로고
    • Effect of implant size and shape on implant success rates: a literature review
    • Lee J.H., Frias V., Lee K.W., and Wright R.F. Effect of implant size and shape on implant success rates: a literature review. J Prosthet Dent 94 4 (2005) 377-381
    • (2005) J Prosthet Dent , vol.94 , Issue.4 , pp. 377-381
    • Lee, J.H.1    Frias, V.2    Lee, K.W.3    Wright, R.F.4
  • 2
    • 27744463334 scopus 로고    scopus 로고
    • Influence of implant/abutment joint designs on abutment screw loosening in a dental implant system
    • Kitagawa T., Tanimoto Y., Odaki M., Nemoto K., and Aida M. Influence of implant/abutment joint designs on abutment screw loosening in a dental implant system. J Biomed Mater Res, Part B - Appl Biomater 75B 2 (2005) 457-463
    • (2005) J Biomed Mater Res, Part B - Appl Biomater , vol.75 B , Issue.2 , pp. 457-463
    • Kitagawa, T.1    Tanimoto, Y.2    Odaki, M.3    Nemoto, K.4    Aida, M.5
  • 3
    • 0014636440 scopus 로고
    • Intraosseous anchorage of dental prosthesis. I. Experimental studies
    • Branemark P.I. Intraosseous anchorage of dental prosthesis. I. Experimental studies. Scand J Plast Recon Surg 3 (1969) 81-100
    • (1969) Scand J Plast Recon Surg , vol.3 , pp. 81-100
    • Branemark, P.I.1
  • 5
    • 33644606208 scopus 로고    scopus 로고
    • In vivo study on biocompatibility and bonding strength of hydroxyapatite-20 vol%Ti composite with bone tissues in the rabbit
    • Chu C.L., Xue X.Y., Zhu J.C., and Yin Z.D. In vivo study on biocompatibility and bonding strength of hydroxyapatite-20 vol%Ti composite with bone tissues in the rabbit. Bio-Med Mater Eng 16 3 (2006) 203-213
    • (2006) Bio-Med Mater Eng , vol.16 , Issue.3 , pp. 203-213
    • Chu, C.L.1    Xue, X.Y.2    Zhu, J.C.3    Yin, Z.D.4
  • 7
    • 47949123195 scopus 로고    scopus 로고
    • Preparation of a bonelike apatite-polymer fiber composite using a simple biomimetic process
    • Yokoyama Y., Oyane A., and It A. Preparation of a bonelike apatite-polymer fiber composite using a simple biomimetic process. J Biomed Mater Res, Part B - Appl Biomater 86B 2 (2008) 341-352
    • (2008) J Biomed Mater Res, Part B - Appl Biomater , vol.86 B , Issue.2 , pp. 341-352
    • Yokoyama, Y.1    Oyane, A.2    It, A.3
  • 8
    • 2542612319 scopus 로고    scopus 로고
    • Design optimization of functionally graded dental implant
    • Hedia H.S., and Mahmoud N.A. Design optimization of functionally graded dental implant. Bio-Med Mater Eng 14 2 (2004) 133-143
    • (2004) Bio-Med Mater Eng , vol.14 , Issue.2 , pp. 133-143
    • Hedia, H.S.1    Mahmoud, N.A.2
  • 9
    • 34548541841 scopus 로고    scopus 로고
    • Low stiffness porous Ti structures for load-bearing implants
    • Krishna B.V., Bose S., and Bandyopadhyay A. Low stiffness porous Ti structures for load-bearing implants. Acta Biomater 3 6 (2007) 997-1006
    • (2007) Acta Biomater , vol.3 , Issue.6 , pp. 997-1006
    • Krishna, B.V.1    Bose, S.2    Bandyopadhyay, A.3
  • 10
    • 1642464933 scopus 로고    scopus 로고
    • Biocompatibility of materials and development to functionally graded implant for bio-medical application
    • Watari F., Yokoyama A., Omori M., Hirai T., Kondo H., Uo M., et al. Biocompatibility of materials and development to functionally graded implant for bio-medical application. Compos Sci Technol 64 6 (2004) p-908
    • (2004) Compos Sci Technol , vol.64 , Issue.6
    • Watari, F.1    Yokoyama, A.2    Omori, M.3    Hirai, T.4    Kondo, H.5    Uo, M.6
  • 11
    • 25844432114 scopus 로고    scopus 로고
    • Design of functionally graded dental implant in the presence of cancellous bone
    • Hedia H.S. Design of functionally graded dental implant in the presence of cancellous bone. J Biomed Mater Res, Part B - Appl Biomater 75B 1 (2005) 74-80
    • (2005) J Biomed Mater Res, Part B - Appl Biomater , vol.75 B , Issue.1 , pp. 74-80
    • Hedia, H.S.1
  • 12
    • 33845475195 scopus 로고    scopus 로고
    • Thermal-mechanical study of functionally graded dental implants with the finite element method
    • Wang F., Lee H.P., and Lu C. Thermal-mechanical study of functionally graded dental implants with the finite element method. J Biomed Mater Res, Part A 80 1 (2007) 146-158
    • (2007) J Biomed Mater Res, Part A , vol.80 , Issue.1 , pp. 146-158
    • Wang, F.1    Lee, H.P.2    Lu, C.3
  • 13
    • 34447506068 scopus 로고    scopus 로고
    • A three-dimensional finite element study on the biomechanical behavior of an FGBM dental implant in surrounding bone
    • Yang J., and Xiang H.J. A three-dimensional finite element study on the biomechanical behavior of an FGBM dental implant in surrounding bone. J Biomech 40 11 (2007) 2377-2385
    • (2007) J Biomech , vol.40 , Issue.11 , pp. 2377-2385
    • Yang, J.1    Xiang, H.J.2
  • 15
    • 21044445338 scopus 로고    scopus 로고
    • Effect of cancellous bone on the functionally graded dental implant concept
    • Hedia H.S. Effect of cancellous bone on the functionally graded dental implant concept. Bio-Med Mater Eng 15 3 (2005) 199-209
    • (2005) Bio-Med Mater Eng , vol.15 , Issue.3 , pp. 199-209
    • Hedia, H.S.1
  • 16
    • 33751511413 scopus 로고    scopus 로고
    • Modeling bamboo as a functionally graded material: lessons for the analysis of affordable materials
    • Silva E.C.N., Walters M.C., and Paulino G.H. Modeling bamboo as a functionally graded material: lessons for the analysis of affordable materials. J Mater Sci 41 21 (2006) 6991-7004
    • (2006) J Mater Sci , vol.41 , Issue.21 , pp. 6991-7004
    • Silva, E.C.N.1    Walters, M.C.2    Paulino, G.H.3
  • 18
    • 21444439414 scopus 로고    scopus 로고
    • Towards automated 3D finite element modeling of direct fiber reinforced composite dental bridge
    • Li W., Swain M.V., Li Q., and Steven G.P. Towards automated 3D finite element modeling of direct fiber reinforced composite dental bridge. J Biomed Mater Res, Part B - Appl Biomater 74B 1 (2005) 520-528
    • (2005) J Biomed Mater Res, Part B - Appl Biomater , vol.74 B , Issue.1 , pp. 520-528
    • Li, W.1    Swain, M.V.2    Li, Q.3    Steven, G.P.4
  • 19
    • 7444222504 scopus 로고    scopus 로고
    • A time-dependent healing function for immediate loaded implants
    • Winter W., Heckmann S.M., and Weber H.P. A time-dependent healing function for immediate loaded implants. J Biomech 37 12 (2004) 1861-1867
    • (2004) J Biomech , vol.37 , Issue.12 , pp. 1861-1867
    • Winter, W.1    Heckmann, S.M.2    Weber, H.P.3
  • 20
    • 0033124101 scopus 로고    scopus 로고
    • Toward an understanding of implant occlusion and strain adaptive bone modeling and remodeling
    • Stanford C.M., and Brand R.A. Toward an understanding of implant occlusion and strain adaptive bone modeling and remodeling. J Prosthet Dent 81 5 (1999) 553-561
    • (1999) J Prosthet Dent , vol.81 , Issue.5 , pp. 553-561
    • Stanford, C.M.1    Brand, R.A.2
  • 21
    • 23944475039 scopus 로고    scopus 로고
    • Influence of cortical bone quality on stress distribution in bone around dental implant
    • Kitagawa T., Tanimoto Y., Nemoto K., and Aida M. Influence of cortical bone quality on stress distribution in bone around dental implant. Dent Mater J 24 2 (2005) 219-224
    • (2005) Dent Mater J , vol.24 , Issue.2 , pp. 219-224
    • Kitagawa, T.1    Tanimoto, Y.2    Nemoto, K.3    Aida, M.4
  • 23
    • 34447646710 scopus 로고    scopus 로고
    • A mathematical model for simulating the bone remodeling process under mechanical stimulus
    • Li I., Li H., Shi L., Fok A.S.L., Ucer C., Deulin H., et al. A mathematical model for simulating the bone remodeling process under mechanical stimulus. Dent Mater 23 9 (2007) 1073-1078
    • (2007) Dent Mater , vol.23 , Issue.9 , pp. 1073-1078
    • Li, I.1    Li, H.2    Shi, L.3    Fok, A.S.L.4    Ucer, C.5    Deulin, H.6
  • 25
    • 56349140546 scopus 로고    scopus 로고
    • Functionally graded implant and its effect on bone remodeling
    • Lin D., Li Q., Li W., and Swain M. Functionally graded implant and its effect on bone remodeling. Adv Mater Res 47-50 (2008) 1035-1038
    • (2008) Adv Mater Res , vol.47-50 , pp. 1035-1038
    • Lin, D.1    Li, Q.2    Li, W.3    Swain, M.4
  • 26
    • 0026970492 scopus 로고
    • The behavior of adaptive bone-remodeling simulation-models
    • Weinans H., Huiskes R., and Grootenboer H.J. The behavior of adaptive bone-remodeling simulation-models. J Biomech 25 12 (1992) 1425-1441
    • (1992) J Biomech , vol.25 , Issue.12 , pp. 1425-1441
    • Weinans, H.1    Huiskes, R.2    Grootenboer, H.J.3
  • 27
    • 0343247726 scopus 로고    scopus 로고
    • A uniform strain criterion for trabecular bone adaptation: do continuum-level strain gradients drive adaptation?
    • Turner C.H., Anne V., and Pidaparti R.M.V. A uniform strain criterion for trabecular bone adaptation: do continuum-level strain gradients drive adaptation?. J Biomech 30 6 (1997) 555-563
    • (1997) J Biomech , vol.30 , Issue.6 , pp. 555-563
    • Turner, C.H.1    Anne, V.2    Pidaparti, R.M.V.3
  • 28
    • 69049114431 scopus 로고
    • A hypothesis concerning the effect of implant rigidity on adaptive cortical bone remodeling in the femur
    • Huiskes R., Dalstra M., Vondervenne R., Grootenboer H., and Slooff T.J. A hypothesis concerning the effect of implant rigidity on adaptive cortical bone remodeling in the femur. J Biomech 20 8 (1987) 808-809
    • (1987) J Biomech , vol.20 , Issue.8 , pp. 808-809
    • Huiskes, R.1    Dalstra, M.2    Vondervenne, R.3    Grootenboer, H.4    Slooff, T.J.5
  • 29
    • 0031655751 scopus 로고    scopus 로고
    • Three rules for bone adaptation to mechanical stimuli
    • Turner C.H. Three rules for bone adaptation to mechanical stimuli. Bone 23 5 (1998) 399-407
    • (1998) Bone , vol.23 , Issue.5 , pp. 399-407
    • Turner, C.H.1
  • 30
    • 0035654511 scopus 로고    scopus 로고
    • Anisotropic elasticity of cortical and cancellous bone in the posterior mandible increases peri-implant stress and strain under oblique loading
    • O'Mahony A.M., Williams J.L., and Spencer P. Anisotropic elasticity of cortical and cancellous bone in the posterior mandible increases peri-implant stress and strain under oblique loading. Clin Oral Implan Res 12 6 (2001) 648-657
    • (2001) Clin Oral Implan Res , vol.12 , Issue.6 , pp. 648-657
    • O'Mahony, A.M.1    Williams, J.L.2    Spencer, P.3
  • 31
    • 0029329134 scopus 로고
    • Relations of mechanical-properties to density and Ct numbers in human bone
    • Rho J.Y., Hobatho M.C., and Ashman R.B. Relations of mechanical-properties to density and Ct numbers in human bone. Med Eng Phys 17 5 (1995) 347-355
    • (1995) Med Eng Phys , vol.17 , Issue.5 , pp. 347-355
    • Rho, J.Y.1    Hobatho, M.C.2    Ashman, R.B.3
  • 32
    • 0036481346 scopus 로고    scopus 로고
    • Resonance frequency assessment of dental implant stability with various bone qualities: a numerical approach
    • Huang H.M., Lee S.Y., Yeh C.Y., and Lin C.T. Resonance frequency assessment of dental implant stability with various bone qualities: a numerical approach. Clin Oral Implan Res 13 1 (2002) 65-74
    • (2002) Clin Oral Implan Res , vol.13 , Issue.1 , pp. 65-74
    • Huang, H.M.1    Lee, S.Y.2    Yeh, C.Y.3    Lin, C.T.4
  • 33
    • 33947210796 scopus 로고    scopus 로고
    • Design optimization of regular hexagonal thin-walled columns with crashworthiness criteria
    • Hou S.J., Li Q., Long S.Y., Yang X.J., and Li W. Design optimization of regular hexagonal thin-walled columns with crashworthiness criteria. Finite Elements in Analysis and Design 43 6-7 (2007) 555-565
    • (2007) Finite Elements in Analysis and Design , vol.43 , Issue.6-7 , pp. 555-565
    • Hou, S.J.1    Li, Q.2    Long, S.Y.3    Yang, X.J.4    Li, W.5
  • 34
    • 27444440006 scopus 로고    scopus 로고
    • Pareto frontier based concept selection under uncertainty with visualization
    • Mattson C.A., and Messac A. Pareto frontier based concept selection under uncertainty with visualization. Optim Eng 6 1 (2005) 85-115
    • (2005) Optim Eng , vol.6 , Issue.1 , pp. 85-115
    • Mattson, C.A.1    Messac, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.