메뉴 건너뛰기




Volumn 15, Issue 4, 2011, Pages 537-549

A comprehensive in vitro study of image accuracy and quality for periodontal diagnosis. PART 1: The influence of X-ray generator on periodontal measurements using conventional and digital receptors

Author keywords

Digital; Exposure time; Image quality; Intraoral radiography; Periodontal bone height; Tube potential

Indexed keywords

ADULT; ALVEOLAR BONE LOSS; ARTICLE; CADAVER; COMPARATIVE STUDY; HUMAN; IMAGE QUALITY; INSTRUMENTATION; JAW; METHODOLOGY; OBSERVER VARIATION; PERIODONTAL DISEASE; RADIATION DOSE; RADIOGRAPHY; STANDARD; TIME; TOOTH RADIOGRAPHY; X RAY FILM;

EID: 84879219306     PISSN: 14326981     EISSN: 14363771     Source Type: Journal    
DOI: 10.1007/s00784-010-0416-8     Document Type: Article
Times cited : (8)

References (38)
  • 3
    • 0034146665 scopus 로고    scopus 로고
    • Comparison of diagnostic accuracy of digital imaging by using CCD and CMOS-APS sensors with E-speed film in the detection of periapical bony lesions
    • Paurazas SB, Geist JR, Pink FE, Hoen MM, Steinman HR (2000) Comparison of diagnostic accuracy of digital imaging by using CCD and CMOS-APS sensors with E-speed film in the detection of periapical bony lesions. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 89: 356-362.
    • (2000) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.89 , pp. 356-362
    • Paurazas, S.B.1    Geist, J.R.2    Pink, F.E.3    Hoen, M.M.4    Steinman, H.R.5
  • 4
    • 0034172412 scopus 로고    scopus 로고
    • Effects of different exposure values on diagnostic accuracy of digital images
    • Pfeiffer P, Schmage P, Nergiz I, Platzer U (2000) Effects of different exposure values on diagnostic accuracy of digital images. Quintessence Int 31: 257-260.
    • (2000) Quintessence Int , vol.31 , pp. 257-260
    • Pfeiffer, P.1    Schmage, P.2    Nergiz, I.3    Platzer, U.4
  • 5
    • 0031243988 scopus 로고    scopus 로고
    • Tissue radiation dosages using the RVG-S with and without niobium filtration
    • Scarfe WC, Farman AG, Brand JW, Kelly MS (1997) Tissue radiation dosages using the RVG-S with and without niobium filtration. Aust Dent J 42: 335-342.
    • (1997) Aust Dent J , vol.42 , pp. 335-342
    • Scarfe, W.C.1    Farman, A.G.2    Brand, J.W.3    Kelly, M.S.4
  • 6
    • 0031137054 scopus 로고    scopus 로고
    • Marginal bone level buccal to mandibular molars in digital radiographs from charge-coupled device and storage phosphor systems. An in vitro study
    • Borg E, Gröndahl K, Gröndahl HG (1997) Marginal bone level buccal to mandibular molars in digital radiographs from charge-coupled device and storage phosphor systems. An in vitro study. J Clin Periodontol 24: 306-312.
    • (1997) J Clin Periodontol , vol.24 , pp. 306-312
    • Borg, E.1    Gröndahl, K.2    Gröndahl, H.G.3
  • 8
    • 37349063792 scopus 로고    scopus 로고
    • Comparison of two imaging modalities: F-speed film and digital images for detection of osseous defects in patients with interdental vertical bone loss
    • Jorgenson T, Masood F, Beckerley JM, Burqin C, Parker DE (2007) Comparison of two imaging modalities: F-speed film and digital images for detection of osseous defects in patients with interdental vertical bone loss. Dento-Maxillo-Facial Radiol 36: 500-505.
    • (2007) Dento-Maxillo-Facial Radiol , vol.36 , pp. 500-505
    • Jorgenson, T.1    Masood, F.2    Beckerley, J.M.3    Burqin, C.4    Parker, D.E.5
  • 9
    • 33947697959 scopus 로고    scopus 로고
    • Marginal bone levels measured in film and digital radiographs corrected for attenuation and visual response: an in-vitro study
    • Li G, Engström PE, Nasström K, Lü ZY, Sanderink G, Welander U (2007) Marginal bone levels measured in film and digital radiographs corrected for attenuation and visual response: an in-vitro study. Dento-Maxillo-Facial Radiol 36: 7-11.
    • (2007) Dento-Maxillo-Facial Radiol , vol.36 , pp. 7-11
    • Li, G.1    Engström, P.E.2    Nasström, K.3    Lü, Z.Y.4    Sanderink, G.5    Welander, U.6
  • 10
    • 0034164420 scopus 로고    scopus 로고
    • Principles of digital imaging
    • van der Stelt PF (2000) Principles of digital imaging. Dent Clin North Am 44: 237-248.
    • (2000) Dent Clin North Am , vol.44 , pp. 237-248
    • van der Stelt, P.F.1
  • 11
  • 12
    • 46449114598 scopus 로고    scopus 로고
    • In practice: how going digital will affect the dental office
    • Farman AG, Levato CM, Gane D, Scarfe WC (2008) In practice: how going digital will affect the dental office. J Am Dent Assoc 139: S14-S19.
    • (2008) J Am Dent Assoc , vol.139 , pp. 14-19
    • Farman, A.G.1    Levato, C.M.2    Gane, D.3    Scarfe, W.C.4
  • 15
    • 24344481333 scopus 로고    scopus 로고
    • The European guidelines on radiation protection in dental radiology. The safe use of radiographs in dental practices
    • European Commission, Brussels
    • European Commission (2004) The European guidelines on radiation protection in dental radiology. The safe use of radiographs in dental practices. Radiation protection 136, Brussels.
    • (2004) Radiation protection , vol.136
  • 17
    • 0028440404 scopus 로고
    • Effects of contrast equalization on energy imparted to the patient: a comparison of two dental generators and two types of intraoral film
    • Helmrot E, Carlsson GA, Eckerdal O (1994) Effects of contrast equalization on energy imparted to the patient: a comparison of two dental generators and two types of intraoral film. Dento-Maxillo-Facial Radiol 23: 83-90.
    • (1994) Dento-Maxillo-Facial Radiol , vol.23 , pp. 83-90
    • Helmrot, E.1    Carlsson, G.A.2    Eckerdal, O.3
  • 19
    • 0034156669 scopus 로고    scopus 로고
    • Subjective image quality of solid-state and photostimulable storage phosphor systems for digital intra-oral radiography
    • Borg E, Attaelmanan A, Gröndahl HG (2000) Subjective image quality of solid-state and photostimulable storage phosphor systems for digital intra-oral radiography. Dento-Maxillo-Facial Radiol 29: 70-75.
    • (2000) Dento-Maxillo-Facial Radiol , vol.29 , pp. 70-75
    • Borg, E.1    Attaelmanan, A.2    Gröndahl, H.G.3
  • 20
    • 24044455022 scopus 로고    scopus 로고
    • A laboratory comparison of three imaging systems for image quality and radiation exposure characteristics
    • Bhaskaran V, Qualtrough AJ, Rushton VE, Worthington HV, Horner K (2005) A laboratory comparison of three imaging systems for image quality and radiation exposure characteristics. Int Endod J 38: 645-652.
    • (2005) Int Endod J , vol.38 , pp. 645-652
    • Bhaskaran, V.1    Qualtrough, A.J.2    Rushton, V.E.3    Worthington, H.V.4    Horner, K.5
  • 22
    • 0034326595 scopus 로고    scopus 로고
    • Intra-oral storage phosphor and conventional radiography in the assessment of alveolar bone structures
    • Kaeppler G, Vogel A, Axmann-Krcmar D (2000) Intra-oral storage phosphor and conventional radiography in the assessment of alveolar bone structures. Dento-Maxillo-Facial Radiol 29: 362-367.
    • (2000) Dento-Maxillo-Facial Radiol , vol.29 , pp. 362-367
    • Kaeppler, G.1    Vogel, A.2    Axmann-Krcmar, D.3
  • 26
    • 24944547825 scopus 로고    scopus 로고
    • Comparison of observer reliability in assessing alveolar bone height on direct digital and conventional radiographs
    • Pecoraro M, Azadivatan-le N, Janal M, Khocht A (2005) Comparison of observer reliability in assessing alveolar bone height on direct digital and conventional radiographs. Dento-Maxillo-Facial Radiol 34: 279-284.
    • (2005) Dento-Maxillo-Facial Radiol , vol.34 , pp. 279-284
    • Pecoraro, M.1    Azadivatan-Le, N.2    Janal, M.3    Khocht, A.4
  • 27
    • 0034152968 scopus 로고    scopus 로고
    • Radiographic and digital imaging in periodontal practice
    • Hausmann E (2000) Radiographic and digital imaging in periodontal practice. J Periodontol 71: 497-503.
    • (2000) J Periodontol , vol.71 , pp. 497-503
    • Hausmann, E.1
  • 28
    • 1542402171 scopus 로고    scopus 로고
    • Imaging methods in periodontology
    • Mol A (2004) Imaging methods in periodontology. Periodontol 2000 34: 34-48.
    • (2004) Periodontol 2000 , vol.34 , pp. 34-48
    • Mol, A.1
  • 29
    • 0034178448 scopus 로고    scopus 로고
    • The usefulness of radiographs in diagnosis and management of periodontal diseases: a review
    • Tugnait A, Clerehugh V, Hirschmann PN (2000) The usefulness of radiographs in diagnosis and management of periodontal diseases: a review. J Dent 28: 219-226.
    • (2000) J Dent , vol.28 , pp. 219-226
    • Tugnait, A.1    Clerehugh, V.2    Hirschmann, P.N.3
  • 30
    • 34547944631 scopus 로고
    • Phantom materials for photons and electrons. The hospital physicists' association, radiotherapy topic group
    • White DR (1977) Phantom materials for photons and electrons. The hospital physicists' association, radiotherapy topic group. Sci Rep Ser 20: 1-30.
    • (1977) Sci Rep Ser , vol.20 , pp. 1-30
    • White, D.R.1
  • 31
    • 63549149056 scopus 로고    scopus 로고
    • SAS Institute Inc, Cary: SAS Institute Inc
    • SAS Institute Inc (2008) SAS/STAT® 9. 2 User's guide. SAS Institute Inc., Cary.
    • (2008) SAS/STAT® 9.2 User's Guide
  • 32
    • 0030112207 scopus 로고    scopus 로고
    • On the dynamic range of different X-ray photon detectors in intra-oral radiography. A comparison of image quality in film, charge-coupled device and storage phosphor systems
    • Borg E, Gröndahl HG (1996) On the dynamic range of different X-ray photon detectors in intra-oral radiography. A comparison of image quality in film, charge-coupled device and storage phosphor systems. Dento-Maxillo-Facial Radiol 25: 82-88.
    • (1996) Dento-Maxillo-Facial Radiol , vol.25 , pp. 82-88
    • Borg, E.1    Gröndahl, H.G.2
  • 35
    • 48649090574 scopus 로고    scopus 로고
    • Detection of periodontal bone loss using digital intraoral and cone beam computed tomography images: an in vitro assessment of bony and/or infrabony defects
    • Vandenberghe B, Jacobs R, Yang J (2008) Detection of periodontal bone loss using digital intraoral and cone beam computed tomography images: an in vitro assessment of bony and/or infrabony defects. Dento-Maxillo-Facial Radiol 37: 252-260.
    • (2008) Dento-Maxillo-Facial Radiol , vol.37 , pp. 252-260
    • Vandenberghe, B.1    Jacobs, R.2    Yang, J.3
  • 36
    • 58849163662 scopus 로고    scopus 로고
    • Effective dose from cone beam CT examinations in dentistry
    • Roberts JA, Drage NA, Davies J, Thomas DW (2009) Effective dose from cone beam CT examinations in dentistry. Br J Radiol 82: 35-40.
    • (2009) Br J Radiol , vol.82 , pp. 35-40
    • Roberts, J.A.1    Drage, N.A.2    Davies, J.3    Thomas, D.W.4
  • 37
    • 52749087498 scopus 로고    scopus 로고
    • Patient risk related to common dental radiographic examinations: the impact of 2007 International Commission on Radiological Protection recommendations regarding dose calculation
    • Ludlow JB, Davies-Ludlow LE, White SC (2008) Patient risk related to common dental radiographic examinations: the impact of 2007 International Commission on Radiological Protection recommendations regarding dose calculation. J Am Dent Assoc 139: 1237-1243.
    • (2008) J Am Dent Assoc , vol.139 , pp. 1237-1243
    • Ludlow, J.B.1    Davies-Ludlow, L.E.2    White, S.C.3
  • 38
    • 0034292806 scopus 로고    scopus 로고
    • Effective dose equivalent and effective dose: comparison for common projections in oral and maxillofacial radiology
    • Gibbs SJ (2000) Effective dose equivalent and effective dose: comparison for common projections in oral and maxillofacial radiology. Oral Surg, Oral Med, Oral Pathol, Oral Radiol Endod 90: 538-545.
    • (2000) Oral Surg, Oral Med, Oral Pathol, Oral Radiol Endod , vol.90 , pp. 538-545
    • Gibbs, S.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.