메뉴 건너뛰기




Volumn 37, Issue 5, 2013, Pages 1202-1212

Rapid freehand MR-guided percutaneous needle interventions: An image-based approach to improve workflow and feasibility

Author keywords

interventional MRI; MR guided interventions; MR guided therapy; percutaneous interventions

Indexed keywords

ANIMAL TISSUE; ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; ECHOGRAPHY; IN VITRO STUDY; IN VIVO STUDY; INTERVENTIONAL MAGNETIC RESONANCE IMAGING; KIDNEY BIOPSY; NONHUMAN; NUCLEAR MAGNETIC RESONANCE SCANNER; PERCUTANEOUS BIOPSY; PRIORITY JOURNAL; SPINAL CORD BIOPSY; SWINE; WORKFLOW;

EID: 84876493027     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.23894     Document Type: Article
Times cited : (34)

References (37)
  • 2
    • 0023006852 scopus 로고
    • MR-guided aspiration biopsy: Needle design and clinical trials
    • Mueller P, Stark D, Simeone J, et al. MR-guided aspiration biopsy: needle design and clinical trials. Radiology 1986; 161: 605-609.
    • (1986) Radiology , vol.161 , pp. 605-609
    • Mueller, P.1    Stark, D.2    Simeone, J.3
  • 3
    • 0034466491 scopus 로고    scopus 로고
    • Magnetic resonance image-guided biopsy and aspiration
    • Lewin JS, Nour SG, Duerk JL,. Magnetic resonance image-guided biopsy and aspiration. Top Magn Reson Imaging 2000; 11: 173-183.
    • (2000) Top Magn Reson Imaging , vol.11 , pp. 173-183
    • Lewin, J.S.1    Nour, S.G.2    Duerk, J.L.3
  • 4
    • 0041842445 scopus 로고    scopus 로고
    • MR fluoroscopy-guided transthoracic fine-needle aspiration biopsy: Feasibility
    • Sakarya ME, Unal O, Ozbay B, et al. MR fluoroscopy-guided transthoracic fine-needle aspiration biopsy: feasibility. Radiology 2003; 228: 589-592.
    • (2003) Radiology , vol.228 , pp. 589-592
    • Sakarya, M.E.1    Unal, O.2    Ozbay, B.3
  • 5
    • 0029114935 scopus 로고
    • Interactive MR-guided biopsy in an open-configuration MR imaging system
    • Silverman SG, Collick BD, Figueira MR, et al. Interactive MR-guided biopsy in an open-configuration MR imaging system. Radiology 1995; 197: 175-181.
    • (1995) Radiology , vol.197 , pp. 175-181
    • Silverman, S.G.1    Collick, B.D.2    Figueira, M.R.3
  • 7
    • 12344276502 scopus 로고    scopus 로고
    • MR Imaging-guided prostate biopsy with a closed MR unit at 1.5 T: Initial results
    • Beyersdorff D, Winkel A, Hamm B, Lenk S, Loening SA, Taupitz M,. MR Imaging-guided prostate biopsy with a closed MR unit at 1.5 T: initial results. Radiology 2005; 234: 576-581.
    • (2005) Radiology , vol.234 , pp. 576-581
    • Beyersdorff, D.1    Winkel, A.2    Hamm, B.3    Lenk, S.4    Loening, S.A.5    Taupitz, M.6
  • 8
    • 31444456822 scopus 로고    scopus 로고
    • MR-guided biopsies of lesions in the retroperitoneal space: Technique and results
    • Zangos S, Eichler K, Wetter A, et al. MR-guided biopsies of lesions in the retroperitoneal space: technique and results. Eur Radiol 2006; 16: 307-312.
    • (2006) Eur Radiol , vol.16 , pp. 307-312
    • Zangos, S.1    Eichler, K.2    Wetter, A.3
  • 9
    • 31144468945 scopus 로고    scopus 로고
    • An augmented reality system for MR image-guided needle biopsy: Initial results in a swine model
    • Wacker FK, Vogt S, Khamene A, et al. An augmented reality system for MR image-guided needle biopsy: initial results in a swine model. Radiology 2006; 238: 497-504.
    • (2006) Radiology , vol.238 , pp. 497-504
    • Wacker, F.K.1    Vogt, S.2    Khamene, A.3
  • 10
    • 42949149608 scopus 로고    scopus 로고
    • MR-guided core biopsy with MR fluoroscopy using a short, wide-bore 1.5-Tesla scanner: Feasibility and initial results
    • Stattaus J, Maderwald S, Forsting M, Barkhausen J, Ladd ME,. MR-guided core biopsy with MR fluoroscopy using a short, wide-bore 1.5-Tesla scanner: feasibility and initial results. J Magn Reson Imaging 2008; 27: 1181-1187.
    • (2008) J Magn Reson Imaging , vol.27 , pp. 1181-1187
    • Stattaus, J.1    Maderwald, S.2    Forsting, M.3    Barkhausen, J.4    Ladd, M.E.5
  • 11
    • 38949096411 scopus 로고    scopus 로고
    • MR-guided biopsy: A review of current techniques and applications
    • Weiss CR, Nour SG, Lewin JS,. MR-guided biopsy: a review of current techniques and applications. J Magn Reson Imaging 2008; 27: 311-325.
    • (2008) J Magn Reson Imaging , vol.27 , pp. 311-325
    • Weiss, C.R.1    Nour, S.G.2    Lewin, J.S.3
  • 12
    • 77953475687 scopus 로고    scopus 로고
    • MR-guided abdominal biopsy using a 1.5-Tesla closed system: A feasibility study
    • Das CJ, Goenka AH, Srivastava DN,. MR-guided abdominal biopsy using a 1.5-Tesla closed system: a feasibility study. Abdom Imaging 2010; 35: 218-223.
    • (2010) Abdom Imaging , vol.35 , pp. 218-223
    • Das, C.J.1    Goenka, A.H.2    Srivastava, D.N.3
  • 13
    • 77957865483 scopus 로고    scopus 로고
    • Magnetic resonance-guided upper abdominal biopsies in a high-field wide-bore 3-T MRI system: Feasibility, handling, and needle artefacts
    • Kühn JP, Langner S, Hegenscheid K, et al. Magnetic resonance-guided upper abdominal biopsies in a high-field wide-bore 3-T MRI system: feasibility, handling, and needle artefacts. Eur Radiol 2010; 20: 2414-2421.
    • (2010) Eur Radiol , vol.20 , pp. 2414-2421
    • Kühn, J.P.1    Langner, S.2    Hegenscheid, K.3
  • 14
    • 79251597863 scopus 로고    scopus 로고
    • MR-guided freehand biopsy of liver lesions with fast continuous imaging using a 1.0-T open MRI scanner: Experience in 50 patients
    • Fischbach F, Bunke J, Thormann M, et al. MR-guided freehand biopsy of liver lesions with fast continuous imaging using a 1.0-T open MRI scanner: experience in 50 patients. Cardiovasc Intervent Radiol 2011; 34: 188-192.
    • (2011) Cardiovasc Intervent Radiol , vol.34 , pp. 188-192
    • Fischbach, F.1    Bunke, J.2    Thormann, M.3
  • 15
    • 79956294511 scopus 로고    scopus 로고
    • MR-compatible assistance system for biopsy in a high-field-strength system: Initial results in patients with suspicious prostate lesions
    • Zangos S, Melzer A, Eichler K, et al. MR-compatible assistance system for biopsy in a high-field-strength system: initial results in patients with suspicious prostate lesions. Radiology 2011; 259: 903-910.
    • (2011) Radiology , vol.259 , pp. 903-910
    • Zangos, S.1    Melzer, A.2    Eichler, K.3
  • 16
    • 84856617660 scopus 로고    scopus 로고
    • Performing MR-guided biopsies in clinical routine: Factors that influence accuracy and procedure time
    • Hoffmann R, Thomas C, Rempp H, et al. Performing MR-guided biopsies in clinical routine: factors that influence accuracy and procedure time. Eur Radiol 2012; 22: 663-671.
    • (2012) Eur Radiol , vol.22 , pp. 663-671
    • Hoffmann, R.1    Thomas, C.2    Rempp, H.3
  • 17
    • 7044239574 scopus 로고    scopus 로고
    • Low-flow vascular malformations: MR-guided percutaneous sclerotherapy in qualitative and quantitative assessment of therapy and outcome
    • Boll DT, Merkle EM, Lewin JS,. Low-flow vascular malformations: MR-guided percutaneous sclerotherapy in qualitative and quantitative assessment of therapy and outcome. Radiology 2004; 233: 376-384.
    • (2004) Radiology , vol.233 , pp. 376-384
    • Boll, D.T.1    Merkle, E.M.2    Lewin, J.S.3
  • 18
    • 0036595375 scopus 로고    scopus 로고
    • MRI-guided periradicular nerve root infiltration therapy in low-field (0.23-T) MRI system using optical instrument tracking
    • Sequeiros RB, Ojala RO, Klemola R, Vaara TJ, Jyrkinen L, Tervonen OA,. MRI-guided periradicular nerve root infiltration therapy in low-field (0.23-T) MRI system using optical instrument tracking. Eur Radiol 2002; 12: 1331-1337.
    • (2002) Eur Radiol , vol.12 , pp. 1331-1337
    • Sequeiros, R.B.1    Ojala, R.O.2    Klemola, R.3    Vaara, T.J.4    Jyrkinen, L.5    Tervonen, O.A.6
  • 19
    • 57149115014 scopus 로고    scopus 로고
    • Diagnostic and interventional MRI of the sacroiliac joints using a 1.5-T open-bore magnet: A one-stop-shopping approach
    • Fritz J, Henes JC, Thomas C, et al. Diagnostic and interventional MRI of the sacroiliac joints using a 1.5-T open-bore magnet: a one-stop-shopping approach. Am J Roentgenol 2008; 191: 1717-1724.
    • (2008) Am J Roentgenol , vol.191 , pp. 1717-1724
    • Fritz, J.1    Henes, J.C.2    Thomas, C.3
  • 20
    • 63849338829 scopus 로고    scopus 로고
    • Freehand real-time MRI guided lumbar spinal injection procedures at 1.5 T: Feasibility, accuracy, and safety
    • Fritz J, Thomas C, Clasen S, Claussen CD, Lewin JS, Pereira PL,. Freehand real-time MRI guided lumbar spinal injection procedures at 1.5 T: feasibility, accuracy, and safety. Am J Roentgenol 2009; 193: W161-W167.
    • (2009) Am J Roentgenol , vol.193
    • Fritz, J.1    Thomas, C.2    Clasen, S.3    Claussen, C.D.4    Lewin, J.S.5    Pereira, P.L.6
  • 21
    • 77951222435 scopus 로고    scopus 로고
    • Image-guided spinal injection procedures in open high-field MRI with vertical field orientation: Feasibility and technical features
    • Streitparth F, Walter T, Wonneberger U, et al. Image-guided spinal injection procedures in open high-field MRI with vertical field orientation: feasibility and technical features. Eur Radiol 2010; 20: 395-403.
    • (2010) Eur Radiol , vol.20 , pp. 395-403
    • Streitparth, F.1    Walter, T.2    Wonneberger, U.3
  • 22
    • 77449151034 scopus 로고    scopus 로고
    • MR monitoring of NaCl-enhanced radiofrequency ablations: Observations on low-and high-field-strength MR images with pathologic correlation
    • Nour SG, Goldberg SN, Wacker FK, et al. MR monitoring of NaCl-enhanced radiofrequency ablations: observations on low-and high-field-strength MR images with pathologic correlation. Radiology 2010; 254: 449-459.
    • (2010) Radiology , vol.254 , pp. 449-459
    • Nour, S.G.1    Goldberg, S.N.2    Wacker, F.K.3
  • 24
    • 77957937652 scopus 로고    scopus 로고
    • MR-guided liver tumor ablation employing open high-field 1.0 T MRI for image-guided brachytherapy
    • Ricke J, Thormann M, Ludewig M, et al. MR-guided liver tumor ablation employing open high-field 1.0 T MRI for image-guided brachytherapy. Eur Radiol 2010; 20: 1985-1993.
    • (2010) Eur Radiol , vol.20 , pp. 1985-1993
    • Ricke, J.1    Thormann, M.2    Ludewig, M.3
  • 25
    • 0031750642 scopus 로고    scopus 로고
    • Vascular lesions in children: Percutaneous MR imaging-guided interstitial Nd: YAG laser therapy - Preliminary experience
    • Wacker FK, Cholewa D, Roggan A, Schilling A, Waldschmidt J, Wolf KJ,. Vascular lesions in children: percutaneous MR imaging-guided interstitial Nd: YAG laser therapy-preliminary experience. Radiology 1998; 208: 789-794.
    • (1998) Radiology , vol.208 , pp. 789-794
    • Wacker, F.K.1    Cholewa, D.2    Roggan, A.3    Schilling, A.4    Waldschmidt, J.5    Wolf, K.J.6
  • 26
    • 33846005871 scopus 로고    scopus 로고
    • Performance of interventions with manipulator-driven real-time MR guidance: Implementation and initial in vitro tests
    • Christoforou E, Akbudak E, Ozcan A, Karanikolas M, Tsekos NV,. Performance of interventions with manipulator-driven real-time MR guidance: implementation and initial in vitro tests. Magn Reson Imaging 2007; 25: 69-77.
    • (2007) Magn Reson Imaging , vol.25 , pp. 69-77
    • Christoforou, E.1    Akbudak, E.2    Ozcan, A.3    Karanikolas, M.4    Tsekos, N.V.5
  • 27
    • 33847093893 scopus 로고    scopus 로고
    • MRI image overlay: Application to arthrography needle insertion
    • Fischer GS, Deguet A, Csoma C, et al. MRI image overlay: application to arthrography needle insertion. Comput Aided Surg 2007; 12: 2-14.
    • (2007) Comput Aided Surg , vol.12 , pp. 2-14
    • Fischer, G.S.1    Deguet, A.2    Csoma, C.3
  • 28
    • 38949145364 scopus 로고    scopus 로고
    • Navigation concepts for MR image-guided interventions
    • Moche M, Trampel R, Kahn T, Busse H,. Navigation concepts for MR image-guided interventions. J Magn Reson Imaging 2008; 27: 276-291.
    • (2008) J Magn Reson Imaging , vol.27 , pp. 276-291
    • Moche, M.1    Trampel, R.2    Kahn, T.3    Busse, H.4
  • 29
    • 77956354480 scopus 로고    scopus 로고
    • Flexible add-on solution for MR image-guided interventions in a closed-bore scanner environment
    • Busse H, Garnov N, Thörmer G, et al. Flexible add-on solution for MR image-guided interventions in a closed-bore scanner environment. Magn Reson Med 2010; 64: 922-928.
    • (2010) Magn Reson Med , vol.64 , pp. 922-928
    • Busse, H.1    Garnov, N.2    Thörmer, G.3
  • 30
    • 0036208348 scopus 로고    scopus 로고
    • Interventional musculoskeletal procedures performed by using MR imaging guidance with a vertically open MR unit: Assessment of techniques and applicability
    • Genant JW, Vandevenne JE, Bergman AG, et al. Interventional musculoskeletal procedures performed by using MR imaging guidance with a vertically open MR unit: assessment of techniques and applicability. Radiology 2002; 223: 127-136.
    • (2002) Radiology , vol.223 , pp. 127-136
    • Genant, J.W.1    Vandevenne, J.E.2    Bergman, A.G.3
  • 31
    • 56349171613 scopus 로고    scopus 로고
    • MR-guided liver biopsy within a short, wide-bore 1.5 Tesla MR system
    • Stattaus J, Maderwald S, Baba HA, et al. MR-guided liver biopsy within a short, wide-bore 1.5 Tesla MR system. Eur Radiol 2008; 18: 2865-2873.
    • (2008) Eur Radiol , vol.18 , pp. 2865-2873
    • Stattaus, J.1    Maderwald, S.2    Baba, H.A.3
  • 32
    • 77950884994 scopus 로고    scopus 로고
    • MRI-guided procedures in various regions of the body using a robotic assistance system in a closed-bore scanner: Preliminary clinical experience and limitations
    • Moche M, Zajonz D, Kahn T, Busse H,. MRI-guided procedures in various regions of the body using a robotic assistance system in a closed-bore scanner: preliminary clinical experience and limitations. J Magn Reson Imaging 2010; 31: 964-974.
    • (2010) J Magn Reson Imaging , vol.31 , pp. 964-974
    • Moche, M.1    Zajonz, D.2    Kahn, T.3    Busse, H.4
  • 33
    • 0029896023 scopus 로고    scopus 로고
    • Needle localization in MR-guided biopsy and aspiration: Effects of field strength, sequence design, and magnetic field orientation
    • Lewin JS, Duerk JL, Jain VR, Petersilge CA, Chao CP, Haaga JR,. Needle localization in MR-guided biopsy and aspiration: effects of field strength, sequence design, and magnetic field orientation. Am J Roentgenol 1996; 166: 1337-1345.
    • (1996) Am J Roentgenol , vol.166 , pp. 1337-1345
    • Lewin, J.S.1    Duerk, J.L.2    Jain, V.R.3    Petersilge, C.A.4    Chao, C.P.5    Haaga, J.R.6
  • 34
    • 84876488750 scopus 로고    scopus 로고
    • Interactive FrontEnd (IFE): A platform for graphical MR scanner control and scan automation. Proc 13th Annual Meeting ISMRM, Miami; (abstract 2170).
    • Lorenz CH, Kirchberg KJ, Zuehlsdorff S, et al. Interactive FrontEnd (IFE): A platform for graphical MR scanner control and scan automation. In: Proc 13th Annual Meeting ISMRM, Miami; 2005 (abstract 2170).
    • (2005)
    • Lorenz, C.H.1    Kirchberg, K.J.2    Zuehlsdorff, S.3
  • 35
    • 38949092065 scopus 로고    scopus 로고
    • Pulse sequences and system interfaces for interventional and real-time MRI
    • Yutzy, S, Duerk, J,. Pulse sequences and system interfaces for interventional and real-time MRI. J Magn Reson Imaging 2008; 27: 267-275.
    • (2008) J Magn Reson Imaging , vol.27 , pp. 267-275
    • Yutzy, S.1    Duerk, J.2
  • 36
    • 84876492237 scopus 로고    scopus 로고
    • An integrated system for catheter tracking and visualization in MR-guided cardiovascular interventions. Proc 19th Annual Meeting ISMRM, Montréal; (abstract 195).
    • Pan L, Barbot J, Shea S, et al. An integrated system for catheter tracking and visualization in MR-guided cardiovascular interventions. In: Proc 19th Annual Meeting ISMRM, Montréal; 2011 (abstract 195).
    • (2011)
    • Pan, L.1    Barbot, J.2    Shea, S.3
  • 37
    • 0036263907 scopus 로고    scopus 로고
    • Generalized autocalibrating partially parallel acquisitions (GRAPPA)
    • Griswold, M, Jakob, P, Heidemann, R, et al. Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 2002; 47: 1202-1210.
    • (2002) Magn Reson Med , vol.47 , pp. 1202-1210
    • Griswold, M.1    Jakob, P.2    Heidemann, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.