Volumn 25, Issue 1, 2007, Pages 69-77

Performance of interventions with manipulator-driven real-time MR guidance: implementation and initial in vitro tests

Author keywords

Dynamic control of scanning parameters; Interventional MRI; Manipulator driven imaging; MR compatible manipulators; Real time MR guidance

Indexed keywords

ACCURACY; ARTICLE; COMPUTER ASSISTED RADIOGRAPHY; COMPUTER INTERFACE; DIAGNOSTIC IMAGING; EVALUATION; FEASIBILITY STUDY; GRADIENT RECALLED ECHO; IN VITRO STUDY; METHODOLOGY; NUCLEAR MAGNETIC RESONANCE IMAGING; NUCLEAR MAGNETIC RESONANCE SCANNER; OPERATOR; PHANTOM; PRIORITY JOURNAL; RADIOLOGICAL PROCEDURES; RADIOLOGY; SIGNAL NOISE RATIO; SYSTEM ANALYSIS; TRUE FAST IMAGING WITH STEADY PRECESSION;

EID: 33846005871     PISSN: 0730725X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.mri.2006.08.016     Document Type: Article
Times cited : (47)

References (25)
  • 1
    • 0003586820 scopus 로고    scopus 로고
    • Debatin F., and Adam G. (Eds), Springer-Verlag, Berlin Heildeberg
    • In: Debatin F., and Adam G. (Eds). Interventional magnetic resonance imaging (1998), Springer-Verlag, Berlin Heildeberg
    • (1998) Interventional magnetic resonance imaging
  • 3
    • 0031909101 scopus 로고    scopus 로고
    • Interventional and intraoperative MRI: a general overview of the field
    • Jolesz F.A. Interventional and intraoperative MRI: a general overview of the field. J Magn Reson Imaging 8 (1998) 3-7
    • (1998) J Magn Reson Imaging , vol.8 , pp. 3-7
    • Jolesz, F.A.1
  • 4
    • 0004253692 scopus 로고    scopus 로고
    • Lufkin R.B. (Ed), Mosby, St. Louis, MO
    • In: Lufkin R.B. (Ed). Interventional MRI (1999), Mosby, St. Louis, MO
    • (1999) Interventional MRI
  • 5
    • 0029422530 scopus 로고
    • Development of an MRI-compatible needle insertion manipulator for stereotactic neurosurgery
    • Masamune K., Kobayashi E., Masutani Y., et al. Development of an MRI-compatible needle insertion manipulator for stereotactic neurosurgery. J Image Guid Surg 1 (1995) 242-248
    • (1995) J Image Guid Surg , vol.1 , pp. 242-248
    • Masamune, K.1    Kobayashi, E.2    Masutani, Y.3
  • 6
    • 0033868738 scopus 로고    scopus 로고
    • Robotic system for biopsy and therapy of breast lesions in a high-field whole-body magnetic resonance tomography unit
    • Kaiser W.A., Fischer H., Vagner J., et al. Robotic system for biopsy and therapy of breast lesions in a high-field whole-body magnetic resonance tomography unit. Invest Radiol 35 (2000) 513-519
    • (2000) Invest Radiol , vol.35 , pp. 513-519
    • Kaiser, W.A.1    Fischer, H.2    Vagner, J.3
  • 7
    • 0036357139 scopus 로고    scopus 로고
    • Robitom - robot for biopsy and therapy of the mamma
    • Felden A., Vagner J., Hinz A., et al. Robitom - robot for biopsy and therapy of the mamma. Biomed Tech (Berl) 47 (2002) 2-5
    • (2002) Biomed Tech (Berl) , vol.47 , pp. 2-5
    • Felden, A.1    Vagner, J.2    Hinz, A.3
  • 8
    • 6044270614 scopus 로고    scopus 로고
    • Design of an MRI-compatible robotic stereotactic device for minimally invasive interventions in the breast
    • Larson B.T., Erdman A.G., Tsekos N.V., et al. Design of an MRI-compatible robotic stereotactic device for minimally invasive interventions in the breast. J Biomech Eng 126 (2004) 458-465
    • (2004) J Biomech Eng , vol.126 , pp. 458-465
    • Larson, B.T.1    Erdman, A.G.2    Tsekos, N.V.3
  • 9
    • 0031887588 scopus 로고    scopus 로고
    • Compatible instrumentation for intraoperative MRI: expanding resources
    • Jolesz F.A., Morrison P.R., Koran S.J., et al. Compatible instrumentation for intraoperative MRI: expanding resources. J Magn Reson Imaging 8 (1998) 8-11
    • (1998) J Magn Reson Imaging , vol.8 , pp. 8-11
    • Jolesz, F.A.1    Morrison, P.R.2    Koran, S.J.3
  • 10
    • 0035140674 scopus 로고    scopus 로고
    • Towards MRI guided surgical manipulator
    • Chinzei K., and Miller K. Towards MRI guided surgical manipulator. Med Sci Monit 7 (2001) 153-163
    • (2001) Med Sci Monit , vol.7 , pp. 153-163
    • Chinzei, K.1    Miller, K.2
  • 11
    • 84974736259 scopus 로고    scopus 로고
    • Endoscope manipulator for trans-nasal neurosurgery, optimized for and compatible to vertical field open MRI
    • Tokyo, Japan
    • Koseki Y., Washio T., Chinzei K., et al. Endoscope manipulator for trans-nasal neurosurgery, optimized for and compatible to vertical field open MRI. MICCAI (2002), Tokyo, Japan 114-121
    • (2002) MICCAI , pp. 114-121
    • Koseki, Y.1    Washio, T.2    Chinzei, K.3
  • 12
    • 0042430628 scopus 로고    scopus 로고
    • System for MR image-guided prostate interventions: canine study
    • Susil R.C., Krieger A., Derbyshire J.A., et al. System for MR image-guided prostate interventions: canine study. Radiology 228 (2003) 886-894
    • (2003) Radiology , vol.228 , pp. 886-894
    • Susil, R.C.1    Krieger, A.2    Derbyshire, J.A.3
  • 13
    • 4243072965 scopus 로고    scopus 로고
    • System for prostate brachytherapy and biopsy in a standard 1.5 T MRI scanner
    • Susil R.C., Camphausen K., Choyke P., et al. System for prostate brachytherapy and biopsy in a standard 1.5 T MRI scanner. Magn Reson Med 52 (2004) 683-687
    • (2004) Magn Reson Med , vol.52 , pp. 683-687
    • Susil, R.C.1    Camphausen, K.2    Choyke, P.3
  • 14
    • 15344344809 scopus 로고    scopus 로고
    • An MRI-compatible surgical robot for precise radiological interventions
    • Hempel E., Fischer H., Gumb L., et al. An MRI-compatible surgical robot for precise radiological interventions. Comput Aided Surg 8 (2003) 180-191
    • (2003) Comput Aided Surg , vol.8 , pp. 180-191
    • Hempel, E.1    Fischer, H.2    Gumb, L.3
  • 15
    • 27444432795 scopus 로고    scopus 로고
    • A prototype manipulator for MR-guided interventions inside standard cylindrical MRI scanners
    • Tsekos N.V., Ozcan A., and Christoforou E. A prototype manipulator for MR-guided interventions inside standard cylindrical MRI scanners. J Biomech Eng 127 (2005) 972-980
    • (2005) J Biomech Eng , vol.127 , pp. 972-980
    • Tsekos, N.V.1    Ozcan, A.2    Christoforou, E.3
  • 16
    • 0034441845 scopus 로고    scopus 로고
    • Minimally invasive videoscopic mitral valve surgery: the current role of surgical robotics
    • Chitwood Jr. W.R., and Nifong L.W. Minimally invasive videoscopic mitral valve surgery: the current role of surgical robotics. J Card Surg 15 (2000) 61-75
    • (2000) J Card Surg , vol.15 , pp. 61-75
    • Chitwood Jr., W.R.1    Nifong, L.W.2
  • 19
    • 1842429552 scopus 로고    scopus 로고
    • Active device tracking and high-resolution intravascular MRI using a novel catheter-based, opposed-solenoid phased array coil
    • Hillenbrand C.M., Elgort D.R., Wong E.Y., et al. Active device tracking and high-resolution intravascular MRI using a novel catheter-based, opposed-solenoid phased array coil. Magn Reson Med 51 (2004) 668-675
    • (2004) Magn Reson Med , vol.51 , pp. 668-675
    • Hillenbrand, C.M.1    Elgort, D.R.2    Wong, E.Y.3
  • 20
    • 0034962809 scopus 로고    scopus 로고
    • A multielement RF coil for MRI guidance of interventional devices
    • Zhang Q., Wendt M., Aschoff A.J., et al. A multielement RF coil for MRI guidance of interventional devices. J Magn Reson Imaging 14 (2001) 56-62
    • (2001) J Magn Reson Imaging , vol.14 , pp. 56-62
    • Zhang, Q.1    Wendt, M.2    Aschoff, A.J.3
  • 21
    • 0033949748 scopus 로고    scopus 로고
    • Active MR guidance of interventional devices with target-navigation
    • Zhang Q., Wendt M., Aschoff A.J., et al. Active MR guidance of interventional devices with target-navigation. Magn Reson Med 44 (2000) 56-65
    • (2000) Magn Reson Med , vol.44 , pp. 56-65
    • Zhang, Q.1    Wendt, M.2    Aschoff, A.J.3
  • 22
    • 2942751891 scopus 로고    scopus 로고
    • MR-trackable intramyocardial injection catheter
    • Karmarkar P.V., Kraitchman D.L., Izbudak I., et al. MR-trackable intramyocardial injection catheter. Magn Reson Med 51 (2004) 1163-1172
    • (2004) Magn Reson Med , vol.51 , pp. 1163-1172
    • Karmarkar, P.V.1    Kraitchman, D.L.2    Izbudak, I.3
  • 23
    • 23444440180 scopus 로고    scopus 로고
    • MR-guided endovascular interventions: device visualization, tracking, navigation, clinical applications, and safety aspects
    • Wacker F.K., Hillenbrand C.M., Duerk J.L., et al. MR-guided endovascular interventions: device visualization, tracking, navigation, clinical applications, and safety aspects. Magn Reson Imaging Clin N Am 13 (2005) 431-439
    • (2005) Magn Reson Imaging Clin N Am , vol.13 , pp. 431-439
    • Wacker, F.K.1    Hillenbrand, C.M.2    Duerk, J.L.3
  • 25
    • 0037382447 scopus 로고    scopus 로고
    • A manipulator system for 14-gauge large core breast biopsies inside a high-field whole-body MR scanner
    • Pfleiderer S.O., Reichenbach J.R., Azhari T., et al. A manipulator system for 14-gauge large core breast biopsies inside a high-field whole-body MR scanner. J Magn Reson Imaging 17 (2003) 493-498
    • (2003) J Magn Reson Imaging , vol.17 , pp. 493-498
    • Pfleiderer, S.O.1    Reichenbach, J.R.2    Azhari, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.