메뉴 건너뛰기




Volumn 34, Issue 1, 2011, Pages 188-192

MR-guided freehand biopsy of liver lesions with fast continuous imaging using a 1.0-T open MRI scanner: Experience in 50 patients

Author keywords

1 Tesla; Freehand intervention; Interventional radiology; Liver biopsy; Needle artefact; Open MRI

Indexed keywords

GADOXETIC ACID;

EID: 79251597863     PISSN: 01741551     EISSN: 1432086X     Source Type: Journal    
DOI: 10.1007/s00270-010-9836-8     Document Type: Article
Times cited : (48)

References (20)
  • 2
    • 0032762568 scopus 로고    scopus 로고
    • Diagnostic yield of MR-guided liver biopsies compared with CT- and US-guided liver biopsies
    • 1:STN:280:DC%2BD3c%2FkvFensw%3D%3D 10.1016/S1051-0443(99)70238-1 10584646
    • AJ Schmidt ST Kee DY Sze, et al. 1999 Diagnostic yield of MR-guided liver biopsies compared with CT- and US-guided liver biopsies J Vasc Interv Radiol 10 1323 1329 1:STN:280:DC%2BD3c%2FkvFensw%3D%3D 10.1016/S1051-0443(99)70238-1 10584646
    • (1999) J Vasc Interv Radiol , vol.10 , pp. 1323-1329
    • Schmidt, A.J.1    Kee, S.T.2    Sze, D.Y.3
  • 3
    • 34250180942 scopus 로고    scopus 로고
    • Liver biopsy under guidance of multislice computed tomography: Comparison of 16G and 18G biopsy needles
    • 1:STN:280:DC%2BD2szgt1KqtQ%3D%3D 10.1007/s00117-005-1336-5 16440187
    • J Stattaus H Kuehl EA Hauth, et al. 2007 Liver biopsy under guidance of multislice computed tomography: comparison of 16G and 18G biopsy needles Radiologe 47 430 438 1:STN:280:DC%2BD2szgt1KqtQ%3D%3D 10.1007/s00117-005-1336-5 16440187
    • (2007) Radiologe , vol.47 , pp. 430-438
    • Stattaus, J.1    Kuehl, H.2    Hauth, E.A.3
  • 4
    • 34848921746 scopus 로고    scopus 로고
    • CT-guided biopsy of small liver lesions: Visibility, artefacts, and corresponding diagnostic accuracy
    • 10.1007/s00270-007-9023-8
    • J Stattaus H Kuehl S Ladd, et al. 2007 CT-guided biopsy of small liver lesions: visibility, artefacts, and corresponding diagnostic accuracy Cardiovasc Interv Radiol 30 928 935 10.1007/s00270-007-9023-8
    • (2007) Cardiovasc Interv Radiol , vol.30 , pp. 928-935
    • Stattaus, J.1    Kuehl, H.2    Ladd, S.3
  • 5
    • 0029790034 scopus 로고    scopus 로고
    • Helical biphasic contrast-enhanced CT of the liver: Technique, indications, interpretation, and pitfalls
    • 8816509
    • JH Oliver III RL Baron 1996 Helical biphasic contrast-enhanced CT of the liver: technique, indications, interpretation, and pitfalls Radiology 201 1 14 8816509
    • (1996) Radiology , vol.201 , pp. 1-14
    • Oliver Iii, J.H.1    Baron, R.L.2
  • 6
    • 0031057511 scopus 로고    scopus 로고
    • Biopsy of hepatic dome lesions: Semi-real-time coronal MR guidance technique
    • 1:STN:280:DyaK2s3htVCmsQ%3D%3D 9057526
    • DS Lu H Lee K Farahani, et al. 1997 Biopsy of hepatic dome lesions: semi-real-time coronal MR guidance technique AJR Am J Roentgenol 168 737 739 1:STN:280:DyaK2s3htVCmsQ%3D%3D 9057526
    • (1997) AJR Am J Roentgenol , vol.168 , pp. 737-739
    • Lu, D.S.1    Lee, H.2    Farahani, K.3
  • 7
    • 42949149608 scopus 로고    scopus 로고
    • MR-guided core biopsy with MR fluoroscopy using a short, wide-bore 1.5 Tesla scanner: Feasibility and initial results
    • 10.1002/jmri.21075 18425833
    • J Stattaus S Maderwald M Forsting, et al. 2008 MR-guided core biopsy with MR fluoroscopy using a short, wide-bore 1.5 Tesla scanner: feasibility and initial results J Magn Reson Imaging 27 1181 1187 10.1002/jmri.21075 18425833
    • (2008) J Magn Reson Imaging , vol.27 , pp. 1181-1187
    • Stattaus, J.1    Maderwald, S.2    Forsting, M.3
  • 8
    • 77953477624 scopus 로고    scopus 로고
    • Image-guided spinal injection procedures in open high-field MRI with vertical field orientation: Feasibility and technical features
    • [Epub ahead of print]
    • Streitparth F, Walter T, Wonneberger U et al.(2009) Image-guided spinal injection procedures in open high-field MRI with vertical field orientation: Feasibility and technical features. Eur Radiol [Epub ahead of print]
    • (2009) Eur Radiol
    • Streitparth, F.1    Walter, T.2    Wonneberger, U.3
  • 9
    • 0029003150 scopus 로고
    • Phase i clinical evaluation of Gd-EOB-DTPA as a hepatobiliary MR contrast agent: Safety, pharmacokinetics, and MR imaging
    • 1:STN:280:DyaK2M3ntlGrsg%3D%3D 7754011
    • B Hamm T Staks A Muhler, et al. 1995 Phase I clinical evaluation of Gd-EOB-DTPA as a hepatobiliary MR contrast agent: safety, pharmacokinetics, and MR imaging Radiology 195 785 792 1:STN:280:DyaK2M3ntlGrsg%3D%3D 7754011
    • (1995) Radiology , vol.195 , pp. 785-792
    • Hamm, B.1    Staks, T.2    Muhler, A.3
  • 10
    • 10744228443 scopus 로고    scopus 로고
    • Improved detection of focal liver lesions at MR imaging: Multicenter comparison of gadoxetic acid-enhanced MR images with intraoperative findings
    • 10.1148/radiol.2301020269 14695400
    • A Huppertz T Balzer A Blakeborough, et al. 2004 Improved detection of focal liver lesions at MR imaging: multicenter comparison of gadoxetic acid-enhanced MR images with intraoperative findings Radiology 230 266 275 10.1148/radiol.2301020269 14695400
    • (2004) Radiology , vol.230 , pp. 266-275
    • Huppertz, A.1    Balzer, T.2    Blakeborough, A.3
  • 11
    • 0029986898 scopus 로고    scopus 로고
    • Phase II clinical evaluation of Gd-EOB-DTPA: Dose, safety aspects, and pulse sequence
    • 1:STN:280:DyaK283gtFyqug%3D%3D 8633143
    • P Reimer EJ Rummeny K Shamsi, et al. 1996 Phase II clinical evaluation of Gd-EOB-DTPA: dose, safety aspects, and pulse sequence Radiology 199 177 183 1:STN:280:DyaK283gtFyqug%3D%3D 8633143
    • (1996) Radiology , vol.199 , pp. 177-183
    • Reimer, P.1    Rummeny, E.J.2    Shamsi, K.3
  • 12
    • 0023006852 scopus 로고
    • MR-guided aspiration biopsy: Needle design and clinical trials
    • 1:STN:280:DyaL2s%2FmvVentw%3D%3D 3786706
    • PR Mueller DD Stark JF Simeone, et al. 1986 MR-guided aspiration biopsy: needle design and clinical trials Radiology 161 605 609 1:STN:280: DyaL2s%2FmvVentw%3D%3D 3786706
    • (1986) Radiology , vol.161 , pp. 605-609
    • Mueller, P.R.1    Stark, D.D.2    Simeone, J.F.3
  • 13
    • 38949145364 scopus 로고    scopus 로고
    • Navigation concepts for MR image-guided interventions
    • 10.1002/jmri.21262 18219682
    • M Moche R Trampel T Kahn, et al. 2008 Navigation concepts for MR image-guided interventions J Magn Reson Imaging 27 276 291 10.1002/jmri.21262 18219682
    • (2008) J Magn Reson Imaging , vol.27 , pp. 276-291
    • Moche, M.1    Trampel, R.2    Kahn, T.3
  • 14
    • 38849107630 scopus 로고    scopus 로고
    • Percutaneous imaging-guided solid organ core needle biopsy: Coaxial versus noncoaxial method
    • 10.2214/AJR.07.2676 18212227
    • MK Hatfield RA Beres SS Sane, et al. 2008 Percutaneous imaging-guided solid organ core needle biopsy: coaxial versus noncoaxial method AJR Am J Roentgenol 190 413 417 10.2214/AJR.07.2676 18212227
    • (2008) AJR Am J Roentgenol , vol.190 , pp. 413-417
    • Hatfield, M.K.1    Beres, R.A.2    Sane, S.S.3
  • 15
    • 0029896023 scopus 로고    scopus 로고
    • Needle localization in MR-guided biopsy and aspiration: Effects of field strength, sequence design, and magnetic field orientation
    • 1:STN:280:DyaK283it1Kquw%3D%3D 8633445
    • JS Lewin JL Duerk VR Jain, et al. 1996 Needle localization in MR-guided biopsy and aspiration: effects of field strength, sequence design, and magnetic field orientation AJR Am J Roentgenol 166 1337 1345 1:STN:280: DyaK283it1Kquw%3D%3D 8633445
    • (1996) AJR Am J Roentgenol , vol.166 , pp. 1337-1345
    • Lewin, J.S.1    Duerk, J.L.2    Jain, V.R.3
  • 16
    • 0029973623 scopus 로고    scopus 로고
    • Visualization of magnetic resonance-compatible needles at 1.5 and 0.2 Tesla
    • 1:STN:280:DyaK28zns1Cmug%3D%3D 10.1007/BF02570186
    • C Frahm HB Gehl UH Melchert, et al. 1996 Visualization of magnetic resonance-compatible needles at 1.5 and 0.2 Tesla Cardiovasc Interv Radiol 19 335 340 1:STN:280:DyaK28zns1Cmug%3D%3D 10.1007/BF02570186
    • (1996) Cardiovasc Interv Radiol , vol.19 , pp. 335-340
    • Frahm, C.1    Gehl, H.B.2    Melchert, U.H.3
  • 17
    • 23444440848 scopus 로고    scopus 로고
    • Percutaneous biopsy from blinded to MR guided: An update on current techniques and applications
    • 10.1016/j.mric.2005.04.009 16084412
    • SG Nour JS Lewin 2005 Percutaneous biopsy from blinded to MR guided: an update on current techniques and applications Magn Reson Imaging Clin N Am 13 441 464 10.1016/j.mric.2005.04.009 16084412
    • (2005) Magn Reson Imaging Clin N Am , vol.13 , pp. 441-464
    • Nour, S.G.1    Lewin, J.S.2
  • 18
    • 38949096411 scopus 로고    scopus 로고
    • MR-guided biopsy: A review of current techniques and applications
    • 10.1002/jmri.21270 18219685
    • CR Weiss SG Nour JS Lewin 2008 MR-guided biopsy: a review of current techniques and applications J Magn Reson Imaging 27 311 325 10.1002/jmri.21270 18219685
    • (2008) J Magn Reson Imaging , vol.27 , pp. 311-325
    • Weiss, C.R.1    Nour, S.G.2    Lewin, J.S.3
  • 19
    • 0038540492 scopus 로고    scopus 로고
    • MR-guided biopsies of undetermined liver lesions: Technique and results
    • 1:STN:280:DC%2BD3s3it1arsA%3D%3D 12743864
    • S Zangos D Kiefl K Eichler, et al. 2003 MR-guided biopsies of undetermined liver lesions: technique and results Rofo 175 688 694 1:STN:280:DC%2BD3s3it1arsA%3D%3D 12743864
    • (2003) Rofo , vol.175 , pp. 688-694
    • Zangos, S.1    Kiefl, D.2    Eichler, K.3
  • 20
    • 0034879733 scopus 로고    scopus 로고
    • Functional capacity of MRI-compatible biopsy needles in comparison with ferromagnetic biopsy needles. in vitro studies
    • 1:STN:280:DC%2BD3MvmvVSrsw%3D%3D 11512240
    • HJ Langen H Kugel M Ortmann, et al. 2001 Functional capacity of MRI-compatible biopsy needles in comparison with ferromagnetic biopsy needles. In vitro studies Rofo 173 658 662 1:STN:280:DC%2BD3MvmvVSrsw%3D%3D 11512240
    • (2001) Rofo , vol.173 , pp. 658-662
    • Langen, H.J.1    Kugel, H.2    Ortmann, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.