메뉴 건너뛰기




Volumn 28, Issue 2, 2013, Pages 114-124

ECMO cannula review

Author keywords

cannula; ECMO; extracorporeal; flow; fluid dynamics

Indexed keywords

HIRULOG;

EID: 84874471741     PISSN: 02676591     EISSN: 1477111X     Source Type: Journal    
DOI: 10.1177/0267659112468014     Document Type: Review
Times cited : (66)

References (44)
  • 1
    • 0036936860 scopus 로고    scopus 로고
    • Flow-rate measurements and models for colloid and crystalloid flows in central and peripheral venous line infusion systems
    • DOI 10.1109/TBME.2002.805468
    • Chen IY, Huang YC, Lin WH. Flow-rate measurements and models for colloid and crystalloid flows in central and peripheral venous line infusion systems. IEEE Trans Biomed Eng. 2002 ; 49: 1632-1638 (Pubitemid 36055722)
    • (2002) IEEE Transactions on Biomedical Engineering , vol.49 , Issue.12 , pp. 1632-1638
    • Chen, I.Y.1    Huang, Y.C.2    Lin, W.H.3
  • 3
    • 0028909422 scopus 로고
    • A relationship between Reynolds stresses and viscous dissipation: Implications to red cell damage
    • Jones SA. A relationship between Reynolds stresses and viscous dissipation: implications to red cell damage. Ann Biomed Eng. 1995 ; 23: 21-28
    • (1995) Ann Biomed Eng , vol.23 , pp. 21-28
    • Jones, S.A.1
  • 4
    • 36448953486 scopus 로고    scopus 로고
    • The cumulative and sublethal effects of turbulence on erythrocytes in a stirred-tank model
    • DOI 10.1007/s10439-007-9387-6
    • Aziz A, Werner BC, Epting KL, Agosti CD, Curtis WR. The cumulative and sublethal effects of turbulence on eryhrocytes in a stirred-tank model. Ann Biomed Eng. 2007 ; 35: 2108-2120 (Pubitemid 350165297)
    • (2007) Annals of Biomedical Engineering , vol.35 , Issue.12 , pp. 2108-2120
    • Aziz, A.1    Werner, B.C.2    Epting, K.L.3    Agosti, C.D.4    Curtis, W.R.5
  • 5
    • 79960364543 scopus 로고    scopus 로고
    • Numerical and experimental flow analysis of the Wang-Zwische double-lumen cannula
    • De Bartolo C, Nigro A, Fragomeni G, et al. Numerical and experimental flow analysis of the Wang-Zwische double-lumen cannula. ASAIO J. 2011 ; 57: 318-327
    • (2011) ASAIO J , vol.57 , pp. 318-327
    • De Bartolo, C.1    Nigro, A.2    Fragomeni, G.3
  • 6
    • 0026013081 scopus 로고
    • A standardized system for describing flow/pressure relationships in vascular access devices
    • Montoya JP, Merz SI, Bartlett RH. A standardized system for describing flow/pressure relationships in vascular access devices. ASAIO Trans. 1991 ; 37: 4-8
    • (1991) ASAIO Trans , vol.37 , pp. 4-8
    • Montoya, J.P.1    Merz, S.I.2    Bartlett, R.H.3
  • 7
    • 0026138215 scopus 로고
    • Evaluation of extracorporeal perfusion catheters using a standardized measurement technique - The M-number
    • Sinard JM, Merz SI, Hatcher MD, Montoya JP, Bartlett RH. Evaluation of extracorporeal perfusion catheters using a standardized measurement technique - the M-number. ASAIO Trans. 1991 ; 37: 60-64
    • (1991) ASAIO Trans , vol.37 , pp. 60-64
    • Sinard, J.M.1    Merz, S.I.2    Hatcher, M.D.3    Montoya, J.P.4    Bartlett, R.H.5
  • 8
    • 0026536565 scopus 로고
    • New method for describing the performance of cardiac surgery cannulas
    • Delius RE, Montoya JP, Merz SI, et al. New method for describing the performance of cardiac surgery cannulas. Ann Thorac Surg. 1992 ; 53: 278-281
    • (1992) Ann Thorac Surg , vol.53 , pp. 278-281
    • Delius, R.E.1    Montoya, J.P.2    Merz, S.I.3
  • 9
    • 34250025116 scopus 로고    scopus 로고
    • Fluid mechanics and clinical success of central venous catheters for dialysis - Answers to simple but persisting problems
    • Ash SR. Fluid mechanics and clinical success of central venous catheters for dialysis - answers to simple but persisting problems. Sem Dial. 2007 ; 20: 237-256
    • (2007) Sem Dial , vol.20 , pp. 237-256
    • Ash, S.R.1
  • 10
    • 0033199710 scopus 로고    scopus 로고
    • Coating-techniques to improve the hemocompatibility of artificial devices used for extracorporeal circulation
    • Wendel HP, Ziemer G. Coating-techniques to improve the hemocompatibility of artificial devices used for extracorporeal circulation. Eur J Cardiothorac Surg. 1999 ; 16: 341-250
    • (1999) Eur J Cardiothorac Surg , vol.16 , pp. 341-250
    • Wendel, H.P.1    Ziemer, G.2
  • 11
    • 68449083833 scopus 로고    scopus 로고
    • Bioline heparin-coated ECMO with bivalirudin anticoagulation in a patient with acute heparin-induced thrombocytopenia: The immune reaction appeared to continue unabated
    • Pappalardo F, Maj G, Scandroglio A, Sampietro F, Zangrillo A, Koster A. Bioline heparin-coated ECMO with bivalirudin anticoagulation in a patient with acute heparin-induced thrombocytopenia: the immune reaction appeared to continue unabated. Perfusion. 2009 ; 24: 135-137
    • (2009) Perfusion , vol.24 , pp. 135-137
    • Pappalardo, F.1    Maj, G.2    Scandroglio, A.3    Sampietro, F.4    Zangrillo, A.5    Koster, A.6
  • 12
    • 34247236608 scopus 로고    scopus 로고
    • Successful Use of Bivalirudin as Anticoagulant for ECMO in a Patient With Acute HIT
    • DOI 10.1016/j.athoracsur.2006.11.051, PII S0003497506023265
    • Koster A, Weng Y, Böttcher W, Gromann T, Kuppe H, Hetzer R. Successful use of bivalirudin as anticoagulant for ECMO in a patient with acute HIT. Ann Thorac Surg. 2007 ; 83: 1865-1867 (Pubitemid 46616760)
    • (2007) Annals of Thoracic Surgery , vol.83 , Issue.5 , pp. 1865-1867
    • Koster, A.1    Weng, Y.2    Bottcher, W.3    Gromann, T.4    Kuppe, H.5    Hetzer, R.6
  • 13
    • 81255128023 scopus 로고    scopus 로고
    • Bivalirudin-based versus conventional heparin anticoagulation for postcardiotomy extracorporeal membrane oxygenation
    • Ranucci M, Ballotta A, Kandil H, et al. Bivalirudin-based versus conventional heparin anticoagulation for postcardiotomy extracorporeal membrane oxygenation. Crit Care. 2011 2011 ; 15: R275
    • (2011) Crit Care , vol.15 , pp. 275
    • Ranucci, M.1    Ballotta, A.2    Kandil, H.3
  • 14
    • 0033866873 scopus 로고    scopus 로고
    • Effects of New Polymer-Coated Extracorporeal Circuits on Biocompatibility During Cardiopulmonary Bypass
    • DOI 10.1046/j.1525-1594.2000.06520.x
    • Saito N, Motoyama S, Sawamoto J. Effects of new polymer-coated extracorporeal circuits on biocompatibility during cardiopulmonary bypass. Artif Organs. 2000 ; 24: 547-554 (Pubitemid 30617024)
    • (2000) Artificial Organs , vol.24 , Issue.7 , pp. 547-554
    • Saito, N.1    Motoyama, S.2    Sawamoto, J.3
  • 15
    • 2442466089 scopus 로고    scopus 로고
    • Hemocompatibility of PMEA Coated Oxygenators Used for Extracorporeal Circulation Procedures
    • DOI 10.1097/01.MAT.0000123638.41808.59
    • Zimmermann AK, Aebert H, Reiz A, et al. Hemocompatibility of PMEA coated oxygenators used for extracorporeal circulation procedures. ASAIO J. 2004 ; 50: 193-199 (Pubitemid 38612818)
    • (2004) ASAIO Journal , vol.50 , Issue.3 , pp. 193-199
    • Zimmermann, A.K.1    Aebert, H.2    Reiz, A.3    Freitag, M.4    Husseini, M.5    Ziemer, G.6    Wendel, H.P.7
  • 16
    • 3142676678 scopus 로고    scopus 로고
    • PMEA coating of pump circuit and oxygenator may attenuate the early systemic inflammatory response in cardiopulmonary bypass surgery
    • Ueyama K, Nishimura K, Nichina T, Nakamura T, Ikeda T, Komeda M. PMEA coating of pump circuit and oxygenator may attenuate the early systemic inflammatory response in cardiopulmonary bypass surgery. ASAIO J. 50: 369-372
    • ASAIO J , vol.50 , pp. 369-372
    • Ueyama, K.1    Nishimura, K.2    Nichina, T.3    Nakamura, T.4    Ikeda, T.5    Komeda, M.6
  • 17
    • 85172054857 scopus 로고    scopus 로고
    • Medtronic Corporation. [Online]
    • Balance Biosurface. Medtronic Corporation. [Online] 2012. http://www.medtronic.com/for-healthcare-professionals/products-therapies/ cardiovascular/cardiopulmonary-products/balance-biosurface/index.htm.
    • (2012) Balance Biosurface
  • 18
    • 85172064094 scopus 로고    scopus 로고
    • Terumo Cardiovascular Systems Corporation. [Online]
    • X Coating. Terumo Cardiovascular Systems Corporation. [Online] 2000. http://www.terumo-cvs.com/doc/811058-XCoatingBrochure-2000.pdf.
    • (2000) X Coating
  • 19
    • 0023726202 scopus 로고
    • Flow dynamics of peripheral venous catheters during extracorporeal membrane oxygenation with a centrifugal pump
    • Wenger RK, Bavaria JE, Ratcliffe MB, Bogen D, Edmunds LH. Flow dynamics of peripheral venous catheters during extracorporeal membrane oxygenation with a centrifugal pump. J Thorac Cardiovasc Surg. 1988 ; 96: 478-484
    • (1988) J Thorac Cardiovasc Surg , vol.96 , pp. 478-484
    • Wenger, R.K.1    Bavaria, J.E.2    Ratcliffe, M.B.3    Bogen, D.4    Edmunds, L.H.5
  • 20
    • 69849088724 scopus 로고    scopus 로고
    • Superior flow for bridge to life with self-expanding venous cannulas
    • von Segesser LK, Kalejs M, Ferrari E, et al. Superior flow for bridge to life with self-expanding venous cannulas. Eur J Cardiothorac Surg. 2009 ; 36: 665-669
    • (2009) Eur J Cardiothorac Surg , vol.36 , pp. 665-669
    • Von Segesser, L.K.1    Kalejs, M.2    Ferrari, E.3
  • 22
    • 0036435827 scopus 로고    scopus 로고
    • Is there any impact of the shape of aortic end-hole cannula on stroke occurrence? Clinical evaluation of straight and bent-tip aortic cannulae
    • DOI 10.1191/0267659102pf613oa
    • Albert AA, Beller CJ, Arnrich B, et al. Is there any impact of the shape of aortic end-hole on stroke occurence? Clinical evaluation of straight and bent-tip aortic cannulae. Perfusion. 2002 ; 17: 451-456 (Pubitemid 35350783)
    • (2002) Perfusion , vol.17 , Issue.6 , pp. 451-456
    • Albert, A.A.1    Beller, C.J.2    Arnrich, B.3    Walter, J.A.4    Rosendahl, U.P.5    Hetzel, A.6    Priss, H.7    Ennker, J.8
  • 24
    • 77954955674 scopus 로고    scopus 로고
    • Effect of pulsatile flow on thrombosis potential with a step wall transition
    • Corbett SC, Ajdari A, Coskun AU, Nayeb-Hashemi H. Effect of pulsatile flow on thrombosis potential with a step wall transition. ASAIO J. 2010 ; 56: 290-295
    • (2010) ASAIO J , vol.56 , pp. 290-295
    • Corbett, S.C.1    Ajdari, A.2    Coskun, A.U.3    Nayeb-Hashemi, H.4
  • 25
    • 33847352955 scopus 로고    scopus 로고
    • A numerical study on the effect of side hole number and arrangement in venous cannulae
    • DOI 10.1016/j.jbiomech.2006.04.005, PII S0021929006001242
    • Park JY, Park CY, Min BG. A numerical study on the effect of side holes number and arrangement in venous cannulae. J Biomech. 2007 ; 40: 1153-1157 (Pubitemid 46349057)
    • (2007) Journal of Biomechanics , vol.40 , Issue.5 , pp. 1153-1157
    • Park, J.Y.1    Park, C.Y.2    Min, B.G.3
  • 26
    • 0036890484 scopus 로고    scopus 로고
    • Computational model of the fluid dynamics of a cannula inserted in a vessel: Incidence of the presence of side holes in blood flow
    • DOI 10.1016/S0021-9290(02)00231-2, PII S0021929002002312
    • Grigioni M, Daniele C, Morbiducci U, et al. Computational model of the fluid dynamics of a cannula inserted in a vessel: incidence of the presence of side holes in blood flow. J Biomech. 2002 ; 35: 1599-1612 (Pubitemid 35341784)
    • (2002) Journal of Biomechanics , vol.35 , Issue.12 , pp. 1599-1612
    • Grigioni, M.1    Daniele, C.2    Morbiducci, U.3    D'Avenio, G.4    Di Benedetto, G.5    Del Gaudio, C.6    Barbaro, V.7
  • 27
    • 84856401877 scopus 로고    scopus 로고
    • The need of slanted side holes for venous cannulae
    • Park JY. The need of slanted side holes for venous cannulae. Comput Math Methods Med. 2012 2012 ; 2012: 854938
    • (2012) Comput Math Methods Med , vol.2012 , pp. 854938
    • Park, J.Y.1
  • 28
    • 0032992655 scopus 로고    scopus 로고
    • Venovenous extracorporeal life support via percutaneous cannulation in 94 patients
    • DOI 10.1378/chest.115.3.818
    • Pranikoff T, Hirschl RB, Remenapp R, Swaniker F, Bartlett RH. Venovenous extracorporeal life support via percutaneous cannulation in 94 patients. Chest. 1999 ; 115: 818-822 (Pubitemid 29129966)
    • (1999) Chest , vol.115 , Issue.3 , pp. 818-822
    • Pranikoff, T.1    Hirschl, R.B.2    Remenapp, R.3    Swaniker, F.4    Bartlett, R.H.5
  • 29
    • 68249093349 scopus 로고    scopus 로고
    • Outcome of extracorporeal membrane oxygenation for early primary graft failure after pediatric heart transplantation
    • Tissot C, Buckvold S, Phelps CM, et al. Outcome of extracorporeal membrane oxygenation for early primary graft failure after pediatric heart transplantation. J Am Coll Cardiol. 54: 730-737
    • J Am Coll Cardiol , vol.54 , pp. 730-737
    • Tissot, C.1    Buckvold, S.2    Phelps, C.M.3
  • 30
    • 84862855221 scopus 로고    scopus 로고
    • Management for left ventricular distension during peripheral extracorporeal membrane oxygenation for cardiogenic shock
    • Soleimani B, Pae WE. Management for left ventricular distension during peripheral extracorporeal membrane oxygenation for cardiogenic shock. Perfusion. 2012 ; 27: 326-331
    • (2012) Perfusion , vol.27 , pp. 326-331
    • Soleimani, B.1    Pae, W.E.2
  • 31
    • 20444378223 scopus 로고    scopus 로고
    • Extracorporeal membrane oxygenation with right axillary artery perfusion
    • DOI 10.1016/j.athoracsur.2004.01.031, PII S0003497504002851
    • Navia JL, Atik FA, Beyer EA, Ruda Vega P. Extracorporeal membrane oxygenation with right axillary artery perfusion. Ann Thorac Surg. 2005 ; 79: 2163-2165 (Pubitemid 40804220)
    • (2005) Annals of Thoracic Surgery , vol.79 , Issue.6 , pp. 2163-2165
    • Navia, J.L.1    Atik, F.A.2    Beyer, E.A.3    Vega, P.R.4
  • 32
    • 84875209325 scopus 로고    scopus 로고
    • Outcomes of axillary artery side graft cannulation for extracorporeal membrane oxygenation
    • Sep 20. pii: S0022-5223(12)01087-2. doi: 10.1016/j.jtcvs.2012.08.070. Epub ahead of print
    • Chamogeorgakis T, Lima B, Shafii AE, et al. Outcomes of axillary artery side graft cannulation for extracorporeal membrane oxygenation. J Thorac Cardiovasc Surg. 2012 Sep 20. pii: S0022-5223(12)01087-2. doi: 10.1016/j.jtcvs.2012.08.070. Epub ahead of print.
    • (2012) J Thorac Cardiovasc Surg
    • Chamogeorgakis, T.1    Lima, B.2    Shafii, A.E.3
  • 34
    • 79960991409 scopus 로고    scopus 로고
    • The acute effect of IABP-induced pulsatility on coronary vascular resistance and graft flow in critically ill patients during ECMO
    • Madershahian N, Wippermann J, Liakopoulos, et al. The acute effect of IABP-induced pulsatility on coronary vascular resistance and graft flow in critically ill patients during ECMO. J Cardiovasc Surg. 2011 ; 52: 411-418
    • (2011) J Cardiovasc Surg , vol.52 , pp. 411-418
    • Madershahian, N.1    Wippermann, J.2    Liakopoulos3
  • 35
    • 84859780240 scopus 로고    scopus 로고
    • Coronary versus carotid blood flow and coronary perfusion pressure in a pig model of prolonged cardiac arrest treated by different modes of venoarterial ECMO and intraaortic balloon counterpulsation
    • Bělohlávek J, Mlček M, Huptych M, et al. Coronary versus carotid blood flow and coronary perfusion pressure in a pig model of prolonged cardiac arrest treated by different modes of venoarterial ECMO and intraaortic balloon counterpulsation. Crit Care. 2012 ; 16: R50
    • (2012) Crit Care , vol.16 , pp. 50
    • Bělohlávek, J.1    Mlček, M.2    Huptych, M.3
  • 36
    • 81855213244 scopus 로고    scopus 로고
    • Left ventricular decompression during peripheral extracorporeal membrane oxygenation support with the use of the novel iVAC pulsatile paracorporeal assist device
    • Anastasiadis K, Chalvatzoulis O, Antonitsis P, Tossios P, Papakobstantinou C. Left ventricular decompression during peripheral extracorporeal membrane oxygenation support with the use of the novel iVAC pulsatile paracorporeal assist device. Ann Thorac Surg. 2011 ; 92: 2257-2259
    • (2011) Ann Thorac Surg , vol.92 , pp. 2257-2259
    • Anastasiadis, K.1    Chalvatzoulis, O.2    Antonitsis, P.3    Tossios, P.4    Papakobstantinou, C.5
  • 37
    • 84860729729 scopus 로고    scopus 로고
    • Impella and extracorporeal membrane oxygenation: A demanding combination
    • Beurtheret S, Mordant P, Pavie A, Leprince P. Impella and extracorporeal membrane oxygenation: a demanding combination. ASAIO J. 2012 ; 58: 291-293
    • (2012) ASAIO J , vol.58 , pp. 291-293
    • Beurtheret, S.1    Mordant, P.2    Pavie, A.3    Leprince, P.4
  • 38
    • 81455154874 scopus 로고    scopus 로고
    • Extracorporeal membrane oxygenation for ARDS in adults
    • Brodie D, Bacchetta M. Extracorporeal membrane oxygenation for ARDS in adults. N Engl J Med. 2011 ; 365: 1905-1924
    • (2011) N Engl J Med , vol.365 , pp. 1905-1924
    • Brodie, D.1    Bacchetta, M.2
  • 39
    • 4644224408 scopus 로고    scopus 로고
    • Extracororeal life support for severe acute respiratory distress syndrome in adults
    • Hemmila MR, Rowe SA, Boules TN, et al. Extracororeal life support for severe acute respiratory distress syndrome in adults. Ann Surg. 2004 ; 240: 595-605
    • (2004) Ann Surg , vol.240 , pp. 595-605
    • Hemmila, M.R.1    Rowe, S.A.2    Boules, T.N.3
  • 40
    • 77951631734 scopus 로고    scopus 로고
    • A new miniaturised system for extracorporeal membrane oxygenation in adult respiratory failure
    • Müller T, Philipp A, Luchner A, et al. A new miniaturised system for extracorporeal membrane oxygenation in adult respiratory failure. Crit Care. 2009 ; 13: R205
    • (2009) Crit Care , vol.13 , pp. 205
    • Müller, T.1    Philipp, A.2    Luchner, A.3
  • 43
    • 0029379640 scopus 로고
    • Oxygen delivery with a single cannula tidal flow venovenous system for extracorporeal membrane oxygenation
    • Keszler M, Moront MG, Cox C, Miewski M, Visner MS. Oxygen delivery with a single cannula tidal flow venovenous system for extracorporeal membrane oxygenation. ASAIO J. 1995 ; 41: 850-854
    • (1995) ASAIO J , vol.41 , pp. 850-854
    • Keszler, M.1    Moront, M.G.2    Cox, C.3    Miewski, M.4    Visner, M.S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.