메뉴 건너뛰기




Volumn 17, Issue 6, 2002, Pages 451-456

Is there any impact of the shape of aortic end-hole cannula on stroke occurrence? Clinical evaluation of straight and bent-tip aortic cannulae

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; AORTA VALVE REPLACEMENT; ARTICLE; CANNULA; CEREBROVASCULAR ACCIDENT; CONTROLLED STUDY; CORONARY ARTERY BYPASS GRAFT; CORONARY ARTERY DISEASE; DISEASE SEVERITY; EVALUATION; FEMALE; HEART VALVE SURGERY; HUMAN; INCIDENCE; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; PREVALENCE; PRIORITY JOURNAL; PROSPECTIVE STUDY; STATISTICAL ANALYSIS; STROKE; VALVULAR HEART DISEASE; AORTA; CATHETERIZATION; EQUIPMENT DESIGN; FORECASTING; HEART VALVE REPLACEMENT; HOSPITALIZATION; INSTRUMENTATION; MIDDLE AGED; PATHOPHYSIOLOGY;

EID: 0036435827     PISSN: 02676591     EISSN: None     Source Type: Journal    
DOI: 10.1191/0267659102pf613oa     Document Type: Article
Times cited : (22)

References (19)
  • 1
    • 0035299492 scopus 로고    scopus 로고
    • Evaluation of neurologic assessment and outcomes in cardiac surgical patients
    • Baker R, Andrew M, Knight J. Evaluation of neurologic assessment and outcomes in cardiac surgical patients. Semin Thorac Cardiovasc Surg 2001; 13: 149-57
    • (2001) Semin. Thorac. Cardiovasc. Surg , vol.13 , pp. 149-157
    • Baker, R.1    Andrew, M.2    Knight, J.3
  • 2
    • 0141469033 scopus 로고    scopus 로고
    • Adverse cerebral outcomes after coronary bypass surgery
    • Roach G, Kanchuger M, Mangano CM et al. Adverse cerebral outcomes after coronary bypass surgery. N Engl J Med 1996; 335: 1857-63
    • (1996) N. Engl. J. Med , vol.335 , pp. 1857-1863
    • Roach, G.1    Kanchuger, M.2    Mangano, C.M.3
  • 4
    • 0022658093 scopus 로고
    • The atherosclerotic ascending aorta and transverse arch: A new technique to prevent cerebral injury during bypass: Experience with 13 patients
    • Culliford AT, Colvin SB, Rohrer K, Baumann FG, Spencer FC. The atherosclerotic ascending aorta and transverse arch: a new technique to prevent cerebral injury during bypass: experience with 13 patients. Ann Thorac Surg 1986; 41: 27-35
    • (1986) Ann. Thorac. Surg , vol.41 , pp. 27-35
    • Culliford, A.T.1    Colvin, S.B.2    Rohrer, K.3    Baumann, F.G.4    Spencer, F.C.5
  • 5
    • 0030880871 scopus 로고    scopus 로고
    • Aortic atheroma is related to outcome but not numbers of emboli during coronary bypass
    • Barbut D, Lo YW, Hartman GS et al. Aortic atheroma is related to outcome but not numbers of emboli during coronary bypass. Ann Thorac Surg 1997; 64: 454-59
    • (1997) Ann. Thorac. Surg , vol.64 , pp. 454-459
    • Barbut, D.1    Lo, Y.W.2    Hartman, G.S.3
  • 6
    • 0026642567 scopus 로고
    • Atheroembolism from the ascending aorta. An emerging problem in cardiac surgery
    • Blauth CI, Cosgrove DM, Webb BW et al. Atheroembolism from the ascending aorta. An emerging problem in cardiac surgery. J Thorac Cardiovasc Surg 1992; 103: 1104-12
    • (1992) J. Thorac. Cardiovasc. Surg , vol.103 , pp. 1104-1112
    • Blauth, C.I.1    Cosgrove, D.M.2    Webb, B.W.3
  • 7
    • 0035133894 scopus 로고    scopus 로고
    • Left hemispheric strokes in coronary surgery: Implications for end-hole aortic cannulas
    • Weinstein GS. Left hemispheric strokes in coronary surgery: implications for end-hole aortic cannulas. Ann Thorac Surg 2001; 71: 128-32
    • (2001) Ann. Thorac. Surg , vol.71 , pp. 128-132
    • Weinstein, G.S.1
  • 8
    • 0025361093 scopus 로고
    • Multicentric quality assurance in cardiac surgery. Quadra study of the German Society for Thoracic and Cardiovascular Surgery (QUADRA: Quality retrospective analysis)
    • Struck E, De Vivie ER, Hehrlein F et al. Multicentric quality assurance in cardiac surgery. Quadra study of the German Society for Thoracic and Cardiovascular Surgery (QUADRA: quality retrospective analysis). Thorac Cardiovasc Surg 1990; 38: 123-34
    • (1990) Thorac. Cardiovasc. Surg , vol.38 , pp. 123-134
    • Struck, E.1    De Vivie, E.R.2    Hehrlein, F.3
  • 10
    • 0031788912 scopus 로고    scopus 로고
    • Impaired clearance of emboli (washout) is an important link between hypoperfusion, embolism, and ischemic stroke
    • Caplan LR, Hennerici M. Impaired clearance of emboli (washout) is an important link between hypoperfusion, embolism, and ischemic stroke. Arch Neural 1998; 55: 1475-82
    • (1998) Arch. Neural , vol.55 , pp. 1475-1482
    • Caplan, L.R.1    Hennerici, M.2
  • 12
    • 0034061604 scopus 로고    scopus 로고
    • Hemispheric stroke following cardiac surgery: A case-control estimate of the risk resulting from ipsilateral asymptomatic carotid artery stenosis
    • Hill AB, Obrand D, O’Rourke K, Steinmetz OK, Miller N. Hemispheric stroke following cardiac surgery: a case-control estimate of the risk resulting from ipsilateral asymptomatic carotid artery stenosis. Ann Vasc Surg 2000; 14: 200-209
    • (2000) Ann. Vasc. Surg , vol.14 , pp. 200-209
    • Hill, A.B.1    Obrand, D.2    O’Rourke, K.3    Steinmetz, O.K.4    Miller, N.5
  • 13
    • 0030780049 scopus 로고    scopus 로고
    • Carotid occlusive disease and stroke risk in coronary artery bypass graft surgery
    • Dashe JF, Pessin MS, Murphy RE, Payne DD. Carotid occlusive disease and stroke risk in coronary artery bypass graft surgery. Neurology 1997; 49: 678-86
    • (1997) Neurology , vol.49 , pp. 678-686
    • Dashe, J.F.1    Pessin, M.S.2    Murphy, R.E.3    Payne, D.D.4
  • 14
    • 0028855740 scopus 로고
    • Risk factors for stroke after cardiac surgery: Buffalo Cardiac-Cerebral Study Group
    • Ricotta JJ, Faggioli GL, Castilone A, Hassett JM. Risk factors for stroke after cardiac surgery: Buffalo Cardiac-Cerebral Study Group. J Vasc Surg 1995; 21: 359-64
    • (1995) J. Vasc. Surg , vol.21 , pp. 359-364
    • Ricotta, J.J.1    Faggioli, G.L.2    Castilone, A.3    Hassett, J.M.4
  • 16
    • 0031842491 scopus 로고    scopus 로고
    • Effect of aortic cannula characteristics and blood velocity on transcranial Doppler-detected microemboli during cardiopulmonary bypass
    • Benaroia M, Baker AJ, Mazer CD, Errett L. Effect of aortic cannula characteristics and blood velocity on transcranial Doppler-detected microemboli during cardiopulmonary bypass. J Cardiothorac Vasc Anesth 1998; 12: 266-69
    • (1998) J. Cardiothorac. Vasc. Anesth , vol.12 , pp. 266-269
    • Benaroia, M.1    Baker, A.J.2    Mazer, C.D.3    Errett, L.4
  • 17
    • 0033969729 scopus 로고    scopus 로고
    • An in vitro evaluation of a new cannula tip design compared with two clinically established cannula-tip designs regarding aortic arch vessel perfusion characteristics
    • Houbert-Huebner E, Gerdes A, Sievers HH. An in vitro evaluation of a new cannula tip design compared with two clinically established cannula-tip designs regarding aortic arch vessel perfusion characteristics. Perfusion 2000; 15: 69-76
    • (2000) Perfusion , vol.15 , pp. 69-76
    • Houbert-Huebner, E.1    Gerdes, A.2    Sievers, H.H.3
  • 18
    • 0020629850 scopus 로고
    • Cerebral embolism in the Michael Reese Stroke Registry
    • Caplan LR, Hier DB, D’Cruz I. Cerebral embolism in the Michael Reese Stroke Registry. Stroke 1983; 14: 530-36
    • (1983) Stroke , vol.14 , pp. 530-536
    • Caplan, L.R.1    Hier, D.B.2    D’Cruz, I.3
  • 19
    • 0031943497 scopus 로고    scopus 로고
    • Alterations of neuropsychological function and cerebral glucose metabolism after cardiac surgery are not related only to intraoperative microembolic events
    • Jacobs A, Neveling M, Horst M et al. Alterations of neuropsychological function and cerebral glucose metabolism after cardiac surgery are not related only to intraoperative microembolic events. Stroke 1998; 29: 660-67
    • (1998) Stroke , vol.29 , pp. 660-667
    • Jacobs, A.1    Neveling, M.2    Horst, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.