메뉴 건너뛰기




Volumn 52, Issue 3, 2011, Pages 411-418

The acute effect of IABP-induced pulsatility on coronary vascular resistance and graft flow in critical ill patients during ECMO

Author keywords

Extracorporeal membrane oxygenation; Heart bypass; Intra aortic balloon pumping

Indexed keywords

ACUTE HEART INFARCTION; ADULT; AGED; AORTA BALLOON; AORTA FLOW; ARTICLE; ASSISTED CIRCULATION; CARDIOVASCULAR PARAMETERS; CLINICAL ARTICLE; CORONARY ARTERY BLOOD FLOW; CORONARY ARTERY BYPASS GRAFT; CORONARY BYPASS FLOW; CORONARY VASCULAR RESISTANCE; CRITICALLY ILL PATIENT; EXTRACORPOREAL OXYGENATION; FEMALE; GRAFT FLOW RESERVE; HEART LEFT VENTRICLE FILLING; HEMODYNAMICS; HIGH RISK PATIENT; HUMAN; MALE; PULSATILITY INDEX; VEIN BLOOD FLOW;

EID: 79960991409     PISSN: 00219509     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (34)

References (42)
  • 3
    • 0036165839 scopus 로고    scopus 로고
    • Extracorporeal membrane oxygenation support for adult postcardiotomy cardiogenic shock
    • DOI 10.1016/S0003-4975(01)03330-6, PII S0003497501033306
    • Ko WJ, Lin CY, Chen R, Wang SS, Lin FY, Chen YS. Extracorporeal Mmbrane Oxygenation Suppot for adult postcardiotomy cardiogenic shock. Ann Thorac Surg 2002;73:538-45. (Pubitemid 34117405)
    • (2002) Annals of Thoracic Surgery , vol.73 , Issue.2 , pp. 538-545
    • Ko, W.-J.1    Lin, C.-Y.2    Chen, R.J.3    Wang, S.-S.4    Lin, F.-Y.5    Chen, Y.-S.6
  • 4
    • 33646061032 scopus 로고    scopus 로고
    • Intra-aortic balloon counterpulsation
    • Trost JC, Hillis LD. Intra-aortic balloon counterpulsation. Am J Cardiol 2006;97:1391-8.
    • (2006) Am J Cardiol , vol.97 , pp. 1391-1398
    • Trost, J.C.1    Hillis, L.D.2
  • 7
    • 33845776565 scopus 로고    scopus 로고
    • The acute effect of intra-aortic balloon counterpulsation during extracorporeal life support: An experimental study
    • DOI 10.1111/j.1525-1594.2007.00337.x
    • Sauren LD, Reesink KD, Selder JL, Beghi C, van der Veen FH, Maessen JG. The acute effect of intra-aoric balloon counter-pulsation during extracorporeal life support: An experimental study. Artif Organs 2007;31:31-8. (Pubitemid 46011018)
    • (2007) Artificial Organs , vol.31 , Issue.1 , pp. 31-38
    • Sauren, L.D.C.1    Reesink, K.D.2    Selder, J.L.3    Beghi, C.4    Van Der, V.F.H.5    Maessen, J.G.6
  • 11
    • 0032709809 scopus 로고    scopus 로고
    • Cardiopulmonary support and extracorporeal membrane oxygenation for cardiac assist
    • DOI 10.1016/S0003-4975(99)00543-3, PII S0003497599005433
    • Von Segesser LK. Cardiopulmonary support and extracorporeal membrane oxygenation for cardiac arrest. Ann Thorac Surg 1999;68:672-7. (Pubitemid 29521150)
    • (1999) Annals of Thoracic Surgery , vol.68 , Issue.2 , pp. 672-677
    • Von Segesser, L.K.1
  • 12
    • 0023324984 scopus 로고
    • Pro-pulsatile flow is preferable to non-pulsatile flow during cardiopulmonary bypass
    • Shevde K, DeBois W Pro-pulsatile flow is preferable to non-pulsatile flow during cardiopulmonary bypass. J Cardiothorac Anesth 1987;1:165-8.
    • (1987) J Cardiothorac Anesth , vol.1 , pp. 165-168
    • Shevde, K.1    DeBois, W.2
  • 13
    • 0025457114 scopus 로고
    • Physiologic reaction of awake animals to an immediate switch from a pulsatile to nonpulsatile systemic circulation
    • Taenaka Y, Tatsumi E, Nakamura H, Nakatani T, Yagura A, Sekii H et al. Physiologic reaction of awake animals to an immediate switch from a pulsatile to nonpulsatile systemic circulation. ASAIO Trans 1990;36:541-4.
    • (1990) ASAIO Trans , vol.36 , pp. 541-544
    • Taenaka, Y.1    Tatsumi, E.2    Nakamura, H.3    Nakatani, T.4    Yagura, A.5    Sekii, H.6
  • 14
    • 0020072117 scopus 로고
    • Comparative clinical study of pulsatile and non-pulsatile perfusion in 350 consecutive patients
    • Taylor K, Bain W, Davidson K, Turner MA. Comparative clinical study of pulsatile and non-pulsatile perfusion in 350 consecutive patients. Thorax 1982;37:324-30. (Pubitemid 12125187)
    • (1982) Thorax , vol.37 , Issue.5 , pp. 324-330
    • Taylor, K.M.1    Bain, W.H.2    Davidson, K.G.3    Turner, M.A.4
  • 15
    • 33847245851 scopus 로고    scopus 로고
    • Clinical Outcomes Are Similar in Pulsatile and Nonpulsatile Left Ventricular Assist Device Recipients
    • DOI 10.1016/j.athoracsur.2006.10.034, PII S0003497506020467
    • Feller ED, Sorensen EN, Haddad M, Pierson RN 3rd, Johnson FL, Brown JM et al. Clinical outcomes are similar in pulsatile and nonpulsatile left ventricular assist device recipients. Ann Thorac Surg 2007;83:1082-8. (Pubitemid 46328825)
    • (2007) Annals of Thoracic Surgery , vol.83 , Issue.3 , pp. 1082-1088
    • Feller, E.D.1    Sorensen, E.N.2    Haddad, M.3    Pierson, R.N.4    Johnson, F.L.5    Brown, J.M.6    Griffith, B.P.7
  • 16
    • 63149192300 scopus 로고    scopus 로고
    • Effects of centrifugal, axial, and pulsatile left ventricular assist device support on end-organ function in heart failure patients
    • Kamdar F, Boyle A, Liao K, Colvin-Adams M, Joyce L, John R. Effects of centrifugal, axial, and pulsatile left ventricular assist device support on end-organ function in heart failure patients. J Heart Lung Transplant 2009;28:352-9.
    • (2009) J Heart Lung Transplant , vol.28 , pp. 352-359
    • Kamdar, F.1    Boyle, A.2    Liao, K.3    Colvin-Adams, M.4    Joyce, L.5    John, R.6
  • 18
    • 33746840564 scopus 로고    scopus 로고
    • An evaluation of the benefits of pulsatile versus nonpulsatile perfusion during cardiopulmonary bypass procedures in pediatric and adult cardiac patients
    • DOI 10.1097/01.mat.0000225266.80021.9b, PII 0000248020060700000001
    • Ji B, Undar A. An evaluation of the benefits of pulsatile versus non-pulsatile perfusion during cardiopulmonary bypass procedures in pediatric and adult cardiac patients. ASAIO J 2006;52:357-61. (Pubitemid 44174619)
    • (2006) ASAIO Journal , vol.52 , Issue.4 , pp. 357-361
    • Ji, B.1    Undar, A.2
  • 19
    • 2542419343 scopus 로고    scopus 로고
    • Myths and truths of pulsatile and nonpulsatile perfusion during acute and chronic cardiac support
    • DOI 10.1111/j.1525-1594.2004.00086.x
    • Undar A. Myths and truth of pulsatile and nonpulsatile perfusion during acute and chronic cardiac support. Art Organs 2004;28:439-43. (Pubitemid 38680156)
    • (2004) Artificial Organs , vol.28 , Issue.5 , pp. 439-443
    • Undar, A.1
  • 20
    • 0027276990 scopus 로고
    • Nonpulsatile mode of blood flow required for cardiopulmonary bypass and total body perfusion
    • Nose Y. Nonpulsatile mode of blood flow required for cardiopulmonary bypass and total body perfusion. Art Organs 1993;17:92-102. (Pubitemid 23152158)
    • (1993) Artificial Organs , vol.17 , Issue.2 , pp. 92-102
    • Nose, Y.1
  • 21
    • 0001957315 scopus 로고
    • Pulsatile and non-pulsatile perfusion in cardiac surgery: A continuing controversy
    • Lewis T, Graham TR, Arnold E, editors. London, UK: Hodder Headline Group
    • Taylor KM. Pulsatile and non-pulsatile perfusion in cardiac surgery: A continuing controversy. In: Lewis T, Graham TR, Arnold E, editors. Mechanical circulatory support. London, UK: Hodder Headline Group; 1995. p. 106-17.
    • (1995) Mechanical Circulatory Support , pp. 106-117
    • Taylor, K.M.1
  • 24
    • 0030009348 scopus 로고    scopus 로고
    • Coronary arterial perfusion during venoarterial extracorporeal membrane oxygenation
    • DOI 10.1016/S0022-5223(96)70315-X
    • Kato J, Seo T, Ando H, Takagi H, Ito T. Coronary arterial perfusion during venoarterial extracorporeal membrane oxygenation. J Thorac Cardiovasc Surg 1996;111:630-6. (Pubitemid 26087727)
    • (1996) Journal of Thoracic and Cardiovascular Surgery , vol.111 , Issue.3 , pp. 630-636
    • Kato, J.1    Seo, T.2    Ando, H.3    Takagi, H.4    Ito, T.5
  • 25
    • 0014833017 scopus 로고
    • Effect of left heart bypass on left ventricular function and coronary blood flow
    • Sato T, Glenn WWL. Effect of left heart bypass on left ventricular function and coronary blood flow. Surgery 1970;68:314-22.
    • (1970) Surgery , vol.68 , pp. 314-322
    • Sato, T.1    Glenn, W.W.L.2
  • 27
    • 0023795562 scopus 로고
    • Doppler echocardiographic evaluation of cardiac performance in infants on prolonged extracorporeal membrane oxygenation
    • Martin GR, Short BL. Doppler echocardiographic evaluation of cardiac performance in infants on prolonged extracorporeal membrane oxygenation. Am J Cardiol 1988;62:29-34.
    • (1988) Am J Cardiol , vol.62 , pp. 29-34
    • Martin, G.R.1    Short, B.L.2
  • 28
    • 0026064799 scopus 로고
    • Experimental study on the hemodynamic effects of veno-arterial extracorporealmembrane oxygenation with an automatically driven blood pump on puppies
    • Seo T, Ito T, Tio K, Kato J, Takagi H. Experimental study on the hemodynamic effects of veno-arterial extracorporealmembrane oxygenation with an automatically driven blood pump on puppies. Artif Organs 1991;15:402-7.
    • (1991) Artif Organs , vol.15 , pp. 402-407
    • Seo, T.1    Ito, T.2    Tio, K.3    Kato, J.4    Takagi, H.5
  • 29
    • 0021927442 scopus 로고
    • Long-term follow-up of infants and children treated with Extracorporeal Membrane Oxygenation (ECMO): A preliminary report
    • DOI 10.1016/S0022-3468(85)80230-X
    • Towne BH, Lott IT, Hicks DA, Healey T. Long-term follow-up of infants and children treated with extracorporeal membrane oxygenation (ECMO): A preliminary report. J Pediatr Surg 1985;20:410-4. (Pubitemid 15227594)
    • (1985) Journal of Pediatric Surgery , vol.20 , Issue.4 , pp. 410-414
    • Towne, B.H.1    Lott, I.T.2    Hicks, D.A.3    Healey, T.4
  • 31
    • 28344447157 scopus 로고    scopus 로고
    • Should we discontinue intraaortic balloon during cardioplegic arrest? Splanchnic function results of a prospective randomized trial
    • DOI 10.1016/j.athoracsur.2005.06.008, PII S000349750501012X
    • Onorati F, Cristodoro L, Mastroroberto P, di Virgilio A, Esposito A, Bilotta M et al. Should we discontinue intraaortic balloon during cardioplegic arrest? Splanchic function results of a prospective randomized trial. Ann Thorac Surg 2005;80:2221-8. (Pubitemid 41718059)
    • (2005) Annals of Thoracic Surgery , vol.80 , Issue.6 , pp. 2221-2228
    • Onorati, F.1    Cristodoro, L.2    Mastroroberto, P.3    Di, V.A.4    Esposito, A.5    Bilotta, M.6    Renzulli, A.7
  • 32
    • 44849128565 scopus 로고    scopus 로고
    • Intra-aortic balloon pump-induced pulsatile flow reduces coagulative and fibrinolytic response to cardiopulmonary bypass
    • DOI 10.1111/j.1525-1594.2008.00563.x
    • Onorati F, Esposito A, Comi MC, Impiombato B, Cristodoro L, Mastroroberto P et al. Intra-aortic balloon pump-induced pulsatile flow reduces coagulative and fibrinolytic response to cardiopulmonary bypass. Artif Organs 2008;32:433-41. (Pubitemid 351798385)
    • (2008) Artificial Organs , vol.32 , Issue.6 , pp. 433-441
    • Onorati, F.1    Esposito, A.2    Comi, M.C.3    Impiombato, B.4    Cristodoro, L.5    Mastroroberto, P.6    Renzulli, A.7
  • 33
    • 34447620091 scopus 로고    scopus 로고
    • A Randomized Trial of Pulsatile Perfusion Using an Intra-Aortic Balloon Pump Versus Nonpulsatile Perfusion on Short-Term Changes in Kidney Function during Cardiopulmonary Bypass during Myocardial Reperfusion
    • DOI 10.1053/j.ajkd.2007.05.017, PII S0272638607008438
    • Onorati F, Presta P, Fuiano G, Mastroroberto P, Comi N, Pezzo F et al. A randomized trial of pulsatile perfusion using an intra-aortic balloon pump versus nonpulsatile perfusion on short-term changes in kidney function during cardiopulmonary bypass during myocardial reperfusion. Am J Kidney Dis 2007;50:229-38. (Pubitemid 47095083)
    • (2007) American Journal of Kidney Diseases , vol.50 , Issue.2 , pp. 229-238
    • Onorati, F.1    Presta, P.2    Fuiano, G.3    Mastroroberto, P.4    Comi, N.5    Pezzo, F.6    Tozzo, C.7    Renzulli, A.8
  • 34
    • 33745209637 scopus 로고    scopus 로고
    • Intraaortic balloon pumping during cardioplegic arrest preserves lung function in patients with chronic obstructive pulmonary disease
    • Onorati F, Cristodoro L, Bilotta M, Impiombato B, Pezzo F, Mastroroberto P et al. Intraaortic balloon pumping during cardioplegic arrest preserves lung function in patients with chronic obstructive pulmonary disease. Ann Thorac Surg 2006;82:35-43.
    • (2006) Ann Thorac Surg , vol.82 , pp. 35-43
    • Onorati, F.1    Cristodoro, L.2    Bilotta, M.3    Impiombato, B.4    Pezzo, F.5    Mastroroberto, P.6
  • 35
    • 62849098570 scopus 로고    scopus 로고
    • Pulsatile perfusion with intra-aortic balloon pumping ameliorates whole bod response to cardiopulmonary bypass in the elderly
    • Onorati F, Santarpino G, Presta P, Caroleo S, Abdalla K, Santangelo E et al. Pulsatile perfusion with intra-aortic balloon pumping ameliorates whole bod response to cardiopulmonary bypass in the elderly. Crit Care Med 2009;37:902-11.
    • (2009) Crit Care Med , vol.37 , pp. 902-911
    • Onorati, F.1    Santarpino, G.2    Presta, P.3    Caroleo, S.4    Abdalla, K.5    Santangelo, E.6
  • 37
    • 0016658717 scopus 로고
    • Improvement of myocardial and other vital organ functions and matabolism with a simple method of pulsatile flow (IABP) during clinical cardiopulmonary bypass
    • Pappas G, Winter SD, Kopriva CJ, Steele PP. Improvement of myocardial and other vital organ functions and matabolism with a simple method of pulsatile flow (IABP) during clinical cardiopulmonary bypass. Surgery 1975;77:34-44.
    • (1975) Surgery , vol.77 , pp. 34-44
    • Pappas, G.1    Winter, S.D.2    Kopriva, C.J.3    Steele, P.P.4
  • 38
    • 33748698886 scopus 로고    scopus 로고
    • Hemodynamic energy generated by a combined centrifugal pump with an intra-aortic balloon pump
    • DOI 10.1097/01.mat.0000237692.12805.01, PII 0000248020060900000024
    • Lim CH, Son HS, Fang YH, Lee JJ, Baik KJ, Kim KH et al. Hemodynamic energy generated in combination a centrifugal pump with an intraaortic balloon pump. ASAIO J 2006;52:592-4. (Pubitemid 44394275)
    • (2006) ASAIO Journal , vol.52 , Issue.5 , pp. 592-594
    • Lim, C.H.1    Son, H.S.2    Fang, Y.H.3    Lee, J.J.4    Baik, K.J.5    Kim, K.H.6    Kim, B.S.7    Lee, H.W.8    Sun, K.9
  • 39
    • 0026512602 scopus 로고
    • The effect of extracorporeal membrane oxygenation on coronary perfusion and regional blood flow distribution
    • Kinsella JP, Gerstmann DR, Rosenberg AA. The effect of extracorporeal membrane oxygenation on coronary perfusion and regional blood flow distribution. Pediatr Res 1992;31:80-4.
    • (1992) Pediatr Res , vol.31 , pp. 80-84
    • Kinsella, J.P.1    Gerstmann, D.R.2    Rosenberg, A.A.3
  • 41
    • 0034773860 scopus 로고    scopus 로고
    • Relation of intraoperative flow measurement with postoperative quantitative angiographic assessment of coronary artery bypass grafting
    • DOI 10.1016/S0003-4975(01)02933-2, PII S0003497501029332
    • Takami Y, Ina H. Relation of intraoperative flow measurement with postoperative quantitative angiographic assessment of coronary artery bypass grafting. Ann Thorac Surg 2001;72:1270-4. (Pubitemid 32938019)
    • (2001) Annals of Thoracic Surgery , vol.72 , Issue.4 , pp. 1270-1274
    • Takami, Y.1    Ina, H.2
  • 42
    • 36549009627 scopus 로고    scopus 로고
    • Pulsatile versus nonpulsatile flow to maintain the equivalent coronary blood flow in the fibrillating heart
    • DOI 10.1097/MAT.0b013e31815b2d00, PII 0000248020071100000028
    • Jung JS, Son HS, Lim CH, Sun K. Pulsatile versus nonpulsatile flow to maintain the equivalent coronary blood flow in the fibrillating heart. ASAIO J 2007;53:785-90. (Pubitemid 350191016)
    • (2007) ASAIO Journal , vol.53 , Issue.6 , pp. 785-790
    • Jung, J.S.1    Son, H.S.2    Lim, C.H.3    Sun, K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.