Numerical and experimental flow analysis of the Wang-Zwische double-lumen cannula

Author keywords

[No Author keywords available]

Indexed keywords

ADVERSE PRESSURE GRADIENT; DISCRETIZATIONS; DYNAMIC BEHAVIORS; DYNAMIC VISCOSITIES; EXPERIMENTAL AND NUMERICAL ANALYSIS; FLOW ANALYSIS; FLOW DISTRIBUTION; GLOBAL PERFORMANCE; GLYCEROL-WATER MIXTURES; GOVERNING EQUATIONS; NEWTONIANS; NUMERICAL COMPUTATIONS; NUMERICAL RESULTS; RECIRCULATION REGIONS; REYNOLDS-AVERAGED NAVIER-STOKES EQUATIONS; THROMBOGENICITY; THROMBOSIS FORMATION; TRANSITIONAL FLOW; WALL SHEAR STRESS;

EID: 79960364543     PISSN: 10582916     EISSN: None     Source Type: Journal    
DOI: 10.1097/MAT.0b013e31821c08bc     Document Type: Article
Times cited : (24)

References (14)
  • 1
    • 59649123725 scopus 로고    scopus 로고
    • Wang-Zwische double lumen cannula- Toward a percutaneous and ambulatory paracorporeal artificial lung
    • Wang D, Zhou X, Liu X, et al: Wang-Zwische double lumen cannula- Toward a percutaneous and ambulatory paracorporeal artificial lung. ASAIO J 54: 606-611, 2008.
    • (2008) ASAIO J , vol.54 , pp. 606-611
    • Wang, D.1    Zhou, X.2    Liu, X.3
  • 2
    • 0035985028 scopus 로고    scopus 로고
    • Numerical calculation of hemolysis levels in peripheral hemodialysis cannulas
    • DOI 10.1046/j.1525-1594.2002.07079.x
    • De Wachter D, Verdonck P: Numerical calculation of hemolysis levels in peripheral hemodialysis catheters. Artif Organs 26: 576-582, 2002. (Pubitemid 34779411)
    • (2002) Artificial Organs , vol.26 , Issue.7 , pp. 576-582
    • De Wachter, D.1    Verdonck, P.2
  • 3
    • 0033213797 scopus 로고    scopus 로고
    • A discussion on the threshold limit for hemolysis related to Reynolds shear stress
    • DOI 10.1016/S0021-9290(99)00063-9, PII S0021929099000639
    • Grigioni M, Daniele C, D'Avenio G, Barbaro V: A discussion on the threshold limit for hemolysis related to Reynolds shear stress. J Biomech 23: 1107-1112, 1999. (Pubitemid 29356050)
    • (1999) Journal of Biomechanics , vol.32 , Issue.10 , pp. 1107-1112
    • Grigioni, M.1    Daniele, C.2    D'Avenio, G.3    Barbaro, V.4
  • 4
    • 36749002678 scopus 로고    scopus 로고
    • Using computational fluid dynamics to evaluate a novel venous cannula [Smath canula®] for use in cardiopulmonary bypass operating procedures
    • DOI 10.1177/0267659107083657
    • Jegger D, Sundaram S, Shah K, et al: Using computational fluid dynamics to evaluate a novel venous cannula (Smart Cannula) for the use in cardiopulmonary bypass operating procedures. Perfusion 22: 257-265, 2007. (Pubitemid 350200812)
    • (2007) Perfusion , vol.22 , Issue.4 , pp. 257-265
    • Jegger, D.1    Sundaram, S.2    Shah, K.3    Mallabiabarrena, I.4    Mucciolo, G.5    Von Segesser, L.K.6
  • 5
    • 0025082325 scopus 로고
    • Estimation of shear stress-related blood damage in heart valve prostheses - in vitro comparison of 25 aortic valves
    • Giersiepen M, Wurzinger LJ, Opitz R, Reul H: Estimation of shear stress related blood damage in heart-valve prostheses: In vitro comparison of 25 aortic valves. Int J Artif Organs 13: 300-306, 1990. (Pubitemid 20310869)
    • (1990) International Journal of Artificial Organs , vol.13 , Issue.5 , pp. 300-306
    • Giersiepen, M.1    Wurzinger, L.J.2    Opitz, R.3    Reul, H.4
  • 6
    • 18744377707 scopus 로고    scopus 로고
    • Evaluation of computational models for hemolysis estimation
    • DOI 10.1097/01.MAT.0000161939.29905.93
    • Gu L, Smith W: Evaluation of compuational models for hemolysis estimation. ASAIO J 51: 202-207, 2005. (Pubitemid 40677127)
    • (2005) ASAIO Journal , vol.51 , Issue.3 , pp. 202-207
    • Gu, L.1    Smith, W.A.2
  • 8
    • 67650491595 scopus 로고    scopus 로고
    • Effects of the pulsatile flow settings on pulsatile waveforms and hemodynamic energy in a PediVAS centrifugal pump
    • Wang S, Rider AR, Kunselman AR, et al: Effects of the pulsatile flow settings on pulsatile waveforms and hemodynamic energy in a PediVAS centrifugal pump. ASAIO J 55: 271-276, 2009.
    • (2009) ASAIO J , vol.55 , pp. 271-276
    • Wang, S.1    Rider, A.R.2    Kunselman, A.R.3
  • 10
    • 0020967328 scopus 로고
    • Velocity measurements in steady flow through axisymmetric stenoses at moderate Reynolds numbers
    • Ahmed S, Giddens D: Velocity measurements in steady flow through axisymmetric stenoses at moderate Reynolds numbers. J Biomech 16: 509-516, 1983.
    • (1983) J Biomech , vol.16 , pp. 509-516
    • Ahmed, S.1    Giddens, D.2
  • 11
    • 0032429524 scopus 로고    scopus 로고
    • Low Reynolds number turbulence modeling of blood flow in arterial stenoses
    • DOI 10.1016/S0006-355X(99)80011-0
    • Ghalichi F, Deng X, De Champlain A, et al: Low Reynolds number turbulence modeling of blood flow in arterial stenoses. Biorheology 35: 281-294, 1998. (Pubitemid 29215048)
    • (1998) Biorheology , vol.35 , Issue.4-5 , pp. 281-294
    • Ghalichi, F.1    Deng, X.2    De Champlain, A.3    Douville, Y.4    King, M.5    Guidoin, R.6
  • 12
    • 77952007580 scopus 로고    scopus 로고
    • Numerical and experimental flow analysis of the Wang-Zwische double lumen cannula (Abstract)
    • Colacino F, De Bartolo C, Fragomeni G, et al: Numerical and experimental flow analysis of the Wang-Zwische double lumen cannula (Abstract). ASAIO J 55: 174, 2009.
    • (2009) ASAIO J , vol.55 , pp. 174
    • Colacino, F.1    De Bartolo, C.2    Fragomeni, G.3
  • 13
    • 2542439910 scopus 로고    scopus 로고
    • Numerical estimation of blood damage in artificial organs
    • DOI 10.1111/j.1525-1594.2004.07265.x
    • Goubergrits L, Affeld K: Numerical estimation of blood damage in artificial organs. Artif Organs 28: 499-507, 2004. (Pubitemid 38684153)
    • (2004) Artificial Organs , vol.28 , Issue.5 , pp. 499-507
    • Goubergrits, L.1    Affeld, K.2
  • 14
    • 0021685904 scopus 로고
    • Human red blood cell hemolysis in a turbulent shear flow: Contribution of Reynolds shear stresses
    • Sallam A, Hwang N: Human red blood cell hemolysis in a turbulent shear flow: Contribution of Reynolds shear stresses. Biorheology 21: 783-797, 1984. (Pubitemid 15195205)
    • (1984) Biorheology , vol.21 , Issue.6 , pp. 783-797
    • Sallam, A.M.1    Hwang, H.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.