메뉴 건너뛰기




Volumn 5, Issue 1, 2013, Pages 35-46

Myocardial perfusion imaging with PET

Author keywords

3D; attenuation correction; myocardial blood flow; myocardial flow reserve; myocardial perfusion; quantification

Indexed keywords

AMMONIA N 13; FLURPIRIDAZ F 18; RUBIDIUM 82; WATER O 15;

EID: 84874093904     PISSN: 17555191     EISSN: 17555205     Source Type: Journal    
DOI: 10.2217/iim.13.1     Document Type: Review
Times cited : (60)

References (50)
  • 1
    • 2542458613 scopus 로고    scopus 로고
    • CT attenuation correction for myocardial perfusion quantification using a PET/CT hybrid scanner
    • Koepfli P, Hany TF, Wyss CA et al. CT attenuation correction for myocardial perfusion quantification using a PET/CT hybrid scanner. J. Nucl. Med. 45(4), 537-542 (2004).
    • (2004) J. Nucl. Med. , vol.45 , Issue.4 , pp. 537-542
    • Koepfli, P.1    Hany, T.F.2    Wyss, C.A.3
  • 2
    • 70249089976 scopus 로고    scopus 로고
    • Quantification of myocardial blood flow will reform the detection of CAD
    • Knuuti J, Kajander S, Mäki M, Ukkonen H. Quantification of myocardial blood flow will reform the detection of CAD. J. Nucl. Cardiol. 16(4), 497-506 (2009).
    • (2009) J. Nucl. Cardiol. , vol.16 , Issue.4 , pp. 497-506
    • Knuuti, J.1    Kajander, S.2    Mäki, M.3    Ukkonen, H.4
  • 3
    • 84874025054 scopus 로고    scopus 로고
    • Phase II safety and clinical comparison with single-photon emission computed tomography myocardial perfusion imaging for detection of coronary artery disease: Flurpiridaz F 18 positron emission tomography
    • pii: S 0735-S1097
    • Berman DS, Maddahi J, Tamarappoo BK et al. Phase II safety and clinical comparison with single-photon emission computed tomography myocardial perfusion imaging for detection of coronary artery disease: flurpiridaz F 18 positron emission tomography. J. Am. Coll. Cardiol. pii: S0735-S1097(12), 05659-05668 (2012).
    • (2012) J. Am. Coll. Cardiol. , vol.12 , pp. 05659-05668
    • Berman, D.S.1    Maddahi, J.2    Tamarappoo, B.K.3
  • 4
    • 80052639367 scopus 로고    scopus 로고
    • Phase I, first-in-human study of BMS747158, a novel F-18-labeled tracer for myocardial perfusion PET: Dosimetry, biodistribution, safety and imaging characteristics after a single injection at rest
    • Maddahi J, Czernin J, Lazewatsky J et al. Phase I, first-in-human study of BMS747158, a novel F-18-labeled tracer for myocardial perfusion PET: dosimetry, biodistribution, safety and imaging characteristics after a single injection at rest. J. Nucl. Med. 52(9), 1490-1498 (2011).
    • (2011) J. Nucl. Med. , vol.52 , Issue.9 , pp. 1490-1498
    • Maddahi, J.1    Czernin, J.2    Lazewatsky, J.3
  • 5
    • 84861491722 scopus 로고    scopus 로고
    • Properties of an ideal PET perfusion tracer: New PET tracer cases and data
    • Maddahi J. Properties of an ideal PET perfusion tracer: new PET tracer cases and data. J. Nucl. Cardiol. 19(Suppl. 1), S30-S37 (2012).
    • (2012) J. Nucl. Cardiol. , vol.19 , Issue.SUPPL. 1
    • Maddahi, J.1
  • 7
    • 2542458613 scopus 로고    scopus 로고
    • CT attenuation correction for myocardial perfusion quantification using a PET/CT hybrid scanner
    • Koepfli P, Hany TF, Wyss CA et al. CT attenuation correction for myocardial perfusion quantification using a PET/CT hybrid scanner. J. Nucl. Med. 45(4), 537-542 (2004).
    • (2004) J. Nucl. Med. , vol.45 , Issue.4 , pp. 537-542
    • Koepfli, P.1    Hany, T.F.2    Wyss, C.A.3
  • 8
    • 70249089976 scopus 로고    scopus 로고
    • Quantification of myocardial blood flow will reform the detection of CAD
    • Knuuti J, Kajander S, Mäki M, Ukkonen H. Quantification of myocardial blood flow will reform the detection of CAD. J. Nucl. Cardiol. 16(4), 497-506 (2009).
    • (2009) J. Nucl. Cardiol. , vol.16 , Issue.4 , pp. 497-506
    • Knuuti, J.1    Kajander, S.2    Mäki, M.3    Ukkonen, H.4
  • 9
    • 84874025054 scopus 로고    scopus 로고
    • Phase II safety and clinical comparison with single-photon emission computed tomography myocardial perfusion imaging for detection of coronary artery disease: Flurpiridaz F 18 positron emission tomography
    • pii: S 0735-S1097
    • Berman DS, Maddahi J, Tamarappoo BK et al. Phase II safety and clinical comparison with single-photon emission computed tomography myocardial perfusion imaging for detection of coronary artery disease: flurpiridaz F 18 positron emission tomography. J. Am. Coll. Cardiol. pii: S0735-S1097(12), 05659-05668 (2012).
    • (2012) J. Am. Coll. Cardiol. , Issue.12 , pp. 05659-05668
    • Berman, D.S.1    Maddahi, J.2    Tamarappoo, B.K.3
  • 10
    • 80052639367 scopus 로고    scopus 로고
    • Phase I, first-in-human study of BMS747158, a novel F-18-labeled tracer for myocardial perfusion PET: Dosimetry, biodistribution, safety and imaging characteristics after a single injection at rest
    • Maddahi J, Czernin J, Lazewatsky J et al. Phase I, first-in-human study of BMS747158, a novel F-18-labeled tracer for myocardial perfusion PET: dosimetry, biodistribution, safety and imaging characteristics after a single injection at rest. J. Nucl. Med. 52(9), 1490-1498 (2011).
    • (2011) J. Nucl. Med. , vol.52 , Issue.9 , pp. 1490-1498
    • Maddahi, J.1    Czernin, J.2    Lazewatsky, J.3
  • 11
    • 84861491722 scopus 로고    scopus 로고
    • Properties of an ideal PET perfusion tracer: New PET tracer cases and data
    • Maddahi J. Properties of an ideal PET perfusion tracer: new PET tracer cases and data. J. Nucl. Cardiol. 19(Suppl. 1), S30-S37 (2012).
    • (2012) J. Nucl. Cardiol. , vol.19 , Issue.SUPPL. 1
    • Maddahi, J.1
  • 13
    • 34447297536 scopus 로고    scopus 로고
    • Quantitative ( 82Rb PET/CT: Development and validation of myocardial perfusion database
    • Santana CA, Folks RD, Garcia EV et al. Quantitative (82)Rb PET/CT: development and validation of myocardial perfusion database. J. Nucl. Med. 48(7), 1122-1128 (2007).
    • (2007) J. Nucl. Med. , vol.48 , Issue.7 , pp. 1122-1128
    • Santana, C.A.1    Folks, R.D.2    Garcia, E.V.3
  • 14
    • 34047093886 scopus 로고    scopus 로고
    • CCS/ CAR/CANM/CNCS/CanSCMR joint position statement on advanced noninvasive cardiac imaging using positron emission tomography, magnetic resonance imaging and multidetector computed tomographic angiography in the diagnosis and evaluation of ischemic heart disease-executive summary
    • Beanlands RS, Chow BJ, Dick A et al. CCS/ CAR/CANM/CNCS/CanSCMR joint position statement on advanced noninvasive cardiac imaging using positron emission tomography, magnetic resonance imaging and multidetector computed tomographic angiography in the diagnosis and evaluation of ischemic heart disease-executive summary. Can. J. Cardiol. 23(2), 107-119 (2007).
    • (2007) Can. J. Cardiol. , vol.23 , Issue.2 , pp. 107-119
    • Beanlands, R.S.1    Chow, B.J.2    Dick, A.3
  • 15
    • 73249128493 scopus 로고    scopus 로고
    • Decreased perfusion in the lateral wall of the left ventricle in PET/CT studies with 13N-ammonia: Evaluation in healthy adults
    • Klingensmith WC, Noonan C, Goldberg JH, Buchwald D, Kimball JT, Manson SM. Decreased perfusion in the lateral wall of the left ventricle in PET/CT studies with 13N-ammonia: evaluation in healthy adults. J. Nucl. Med. Technol. 37(4), 215-219 (2009).
    • (2009) J. Nucl. Med. Technol. , vol.37 , Issue.4 , pp. 215-219
    • Klingensmith, W.C.1    Noonan, C.2    Goldberg, J.H.3    Buchwald, D.4    Kimball, J.T.5    Manson, S.M.6
  • 16
    • 84856803974 scopus 로고    scopus 로고
    • Comparison of clinical tools for measurements of regional stress and rest myocardial blood flow assessed with 13N-ammonia PET/CT
    • Slomka PJ, Alexanderson E, Jácome R et al. Comparison of clinical tools for measurements of regional stress and rest myocardial blood flow assessed with 13N-ammonia PET/CT. J. Nucl. Med. 53(2), 171-181 (2012).
    • (2012) J. Nucl. Med. , vol.53 , Issue.2 , pp. 171-181
    • Slomka, P.J.1    Alexanderson, E.2    Jácome, R.3
  • 17
    • 77956539101 scopus 로고    scopus 로고
    • Intra-and inter-operator repeatability of myocardial blood flow and myocardial flow reserve measurements using rubidium-82 PET and a highly automated analysis program
    • Klein R, Renaud JM, Ziadi MC et al. Intra-and inter-operator repeatability of myocardial blood flow and myocardial flow reserve measurements using rubidium-82 PET and a highly automated analysis program. J. Nucl. Cardiol. 17(4), 600-616 (2010).
    • (2010) J. Nucl. Cardiol. , vol.17 , Issue.4 , pp. 600-616
    • Klein, R.1    Renaud, J.M.2    Ziadi, M.C.3
  • 18
    • 67650035154 scopus 로고    scopus 로고
    • Reproducibility and accuracy of quantitative myocardial blood flow assessment with (82) Rb PET: Comparison with (13)N-ammonia PET
    • El Fakhri G, Kardan A, Sitek A et al. Reproducibility and accuracy of quantitative myocardial blood flow assessment with (82) Rb PET: comparison with (13)N-ammonia PET. J. Nucl. Med. 50(7), 1062-1071 (2009).
    • (2009) J. Nucl. Med. , vol.50 , Issue.7 , pp. 1062-1071
    • El Fakhri, G.1    Kardan, A.2    Sitek, A.3
  • 19
    • 77955466812 scopus 로고    scopus 로고
    • Cardiac positron emission tomography/ computed tomography imaging accurately detects anatomically and functionally significant coronary artery disease
    • Kajander S, Joutsiniemi E, Saraste M et al. Cardiac positron emission tomography/ computed tomography imaging accurately detects anatomically and functionally significant coronary artery disease. Circulation 122(6), 603-613 (2010).
    • (2010) Circulation , vol.122 , Issue.6 , pp. 603-613
    • Kajander, S.1    Joutsiniemi, E.2    Saraste, M.3
  • 20
    • 84872597888 scopus 로고    scopus 로고
    • Reproducible imaging of myocardial flow reserve with rubidium-82 PET-a multi-centre multi-vendor comparison study
    • Dekemp RA, Slomka PJ, Dederck J et al. Reproducible imaging of myocardial flow reserve with rubidium-82 PET-a multi-centre multi-vendor comparison study. Eur. Heart J. Suppl. 13(Suppl. A), A76 (2011).
    • (2011) Eur. Heart J. Suppl. , vol.13 , Issue.SUPPL. A
    • Dekemp, R.A.1    Slomka, P.J.2    Dederck, J.3
  • 21
    • 67649522787 scopus 로고    scopus 로고
    • Quantification of myocardial flow reserve using positron emission imaging the journey to clinical use
    • Beanlands RS, Ziadi MC, Williams K. Quantification of myocardial flow reserve using positron emission imaging the journey to clinical use. J. Am. Coll. Cardiol. 54(2), 157-159 (2009).
    • (2009) J. Am. Coll. Cardiol. , vol.54 , Issue.2 , pp. 157-159
    • Beanlands, R.S.1    Ziadi, M.C.2    Williams, K.3
  • 22
    • 4344684086 scopus 로고    scopus 로고
    • Potential utility of rubidium 82 PET quantification in patients with 3-vessel coronary artery disease
    • Parkash R, Dekemp RA, Ruddy TD et al. Potential utility of rubidium 82 PET quantification in patients with 3-vessel coronary artery disease. J. Nucl. Cardiol. 11(4), 440-449 (2004).
    • (2004) J. Nucl. Cardiol. , vol.11 , Issue.4 , pp. 440-449
    • Parkash, R.1    Dekemp, R.A.2    Ruddy, T.D.3
  • 23
    • 84865094762 scopus 로고    scopus 로고
    • Does quantification of myocardial freserve using rubidium-82 positron emission tomography facilitate detection of multivessel coronary artery disease? J
    • Ziadi MC, Dekemp RA, Williams K et al. Does quantification of myocardial freserve using rubidium-82 positron emission tomography facilitate detection of multivessel coronary artery disease? J. Nucl. Cardiol. 19(4), 670-680 (2012).
    • (2012) Nucl. Cardiol. , vol.19 , Issue.4 , pp. 670-680
    • Ziadi, M.C.1    Dekemp, R.A.2    Williams, K.3
  • 24
    • 66449098736 scopus 로고    scopus 로고
    • Comparison of positron emission tomography measurement of adenosine-stimulated absolute myocardial blood flow versus relative myocardial tracer content for physiological assessment of coronary artery stenosis severity and location
    • Hajjiri MM, Leavitt MB, Zheng H, Spooner AE, Fischman AJ, Gewirtz H. Comparison of positron emission tomography measurement of adenosine-stimulated absolute myocardial blood flow versus relative myocardial tracer content for physiological assessment of coronary artery stenosis severity and location. JACC Cardiovasc. Imaging 2(6), 751-758 (2009).
    • (2009) JACC Cardiovasc. Imaging , vol.2 , Issue.6 , pp. 751-758
    • Hajjiri, M.M.1    Leavitt, M.B.2    Zheng, H.3    Spooner, A.E.4    Fischman, A.J.5    Gewirtz, H.6
  • 25
    • 80054895116 scopus 로고    scopus 로고
    • Incremental diagnostic value of regional myocardial blood flow quantification over relative perfusion imaging with generator-produced rubidium-82 PET
    • Yoshinaga K, Katoh C, Manabe O et al. Incremental diagnostic value of regional myocardial blood flow quantification over relative perfusion imaging with generator-produced rubidium-82 PET. Circ. J. 75(11), 2628-2634 (2011).
    • (2011) Circ. J. , vol.75 , Issue.11 , pp. 2628-2634
    • Yoshinaga, K.1    Katoh, C.2    Manabe, O.3
  • 26
    • 84864767807 scopus 로고    scopus 로고
    • Diagnostic value of 13N-ammonia myocardial perfusion PET: Added value of myocardial flow reserve
    • Fiechter M, Ghadri JR, Gebhard C et al. Diagnostic value of 13N-ammonia myocardial perfusion PET: added value of myocardial flow reserve. J. Nucl. Med. 53(8), 1230-1234 (2012).
    • (2012) J. Nucl. Med. , vol.53 , Issue.8 , pp. 1230-1234
    • Fiechter, M.1    Ghadri, J.R.2    Gebhard, C.3
  • 27
    • 67649385766 scopus 로고    scopus 로고
    • Long-term prognostic value of 13N-ammonia myocardial perfusion positron emission tomography added value of coronary flow reserve
    • Herzog BA, Husmann L, Valenta I et al. Long-term prognostic value of 13N-ammonia myocardial perfusion positron emission tomography added value of coronary flow reserve. J. Am. Coll. Cardiol. 54(2), 150-156 (2009).
    • (2009) J. Am. Coll. Cardiol. , vol.54 , Issue.2 , pp. 150-156
    • Herzog, B.A.1    Husmann, L.2    Valenta, I.3
  • 28
    • 79955777624 scopus 로고    scopus 로고
    • Prediction of short-term cardiovascular events using quantification of global myocardial flow reserve in patients referred for clinical 82Rb PET perfusion imaging
    • Fukushima K, Javadi MS, Higuchi T et al. Prediction of short-term cardiovascular events using quantification of global myocardial flow reserve in patients referred for clinical 82Rb PET perfusion imaging. J. Nucl. Med. 52(5), 726-732 (2011).
    • (2011) J. Nucl. Med. , vol.52 , Issue.5 , pp. 726-732
    • Fukushima, K.1    Javadi, M.S.2    Higuchi, T.3
  • 29
    • 79961174089 scopus 로고    scopus 로고
    • Impaired myocardial flow reserve on rubidium-82 positron emission tomography imaging predicts adverse outcomes in patients assessed for myocardial ischemia
    • Ziadi MC, Dekemp RA, Williams KA et al. Impaired myocardial flow reserve on rubidium-82 positron emission tomography imaging predicts adverse outcomes in patients assessed for myocardial ischemia. J. Am. Coll. Cardiol. 58(7), 740-748 (2011).
    • (2011) J. Am. Coll. Cardiol. , vol.58 , Issue.7 , pp. 740-748
    • Ziadi, M.C.1    Dekemp, R.A.2    Williams, K.A.3
  • 30
    • 81355146433 scopus 로고    scopus 로고
    • Improved cardiac risk assessment with noninvasive measures of coronary flow reserve
    • Murthy VL, Naya M, Foster CR et al. Improved cardiac risk assessment with noninvasive measures of coronary flow reserve. Circulation 124(20), 2215-2224 (2011).
    • (2011) Circulation , vol.124 , Issue.20 , pp. 2215-2224
    • Murthy, V.L.1    Naya, M.2    Foster, C.R.3
  • 31
    • 0031938579 scopus 로고    scopus 로고
    • Incremental prognostic value of myocardial perfusion single photon emission computed tomography for the prediction of cardiac death: Differential stratification for risk of cardiac death and myocardial infarction
    • Hachamovitch R, Berman D, Shaw L et al. Incremental prognostic value of myocardial perfusion single photon emission computed tomography for the prediction of cardiac death: differential stratification for risk of cardiac death and myocardial infarction. Circulation 97(6), 535-543 (1998).
    • (1998) Circulation , vol.97 , Issue.6 , pp. 535-543
    • Hachamovitch, R.1    Berman, D.2    Shaw, L.3
  • 32
    • 77956658504 scopus 로고    scopus 로고
    • Cardiac PET imaging for the detection and monitoring of coronary artery disease and microvascular health
    • Schindler TH, Schelbert HR, Quercioli A, Dilsizian V. Cardiac PET imaging for the detection and monitoring of coronary artery disease and microvascular health. JACC Cardiovasc. Imaging 3(6), 623-640 (2010).
    • (2010) JACC Cardiovasc. Imaging , vol.3 , Issue.6 , pp. 623-640
    • Schindler, T.H.1    Schelbert, H.R.2    Quercioli, A.3    Dilsizian, V.4
  • 33
    • 33846186008 scopus 로고    scopus 로고
    • ACCF/AHA 2007 clinical expert consensus document on coronary artery calcium scoring by computed tomography in global cardiovascular risk assessment and in evaluation of patients with chest pain: A report of the American College of Cardiology Foundation Clinical Expert Consensus Task Force
    • (ACCF/AHA Writing Committee to Update the 2000 Expert Consensus Document on Electron Beam Computed Tomography) developed in collaboration with the Society of Atherosclerosis Imaging and Prevention and the Society of Cardiovascular Computed Tomography
    • Greenland P, Bonow RO, Brundage BH et al. ACCF/AHA 2007 clinical expert consensus document on coronary artery calcium scoring by computed tomography in global cardiovascular risk assessment and in evaluation of patients with chest pain: A report of the American College of Cardiology Foundation Clinical Expert Consensus Task Force (ACCF/AHA Writing Committee to Update the 2000 Expert Consensus Document on Electron Beam Computed Tomography) developed in collaboration with the Society of Atherosclerosis Imaging and Prevention and the Society of Cardiovascular Computed Tomography. J. Am. Coll. Cardiol. 49(3), 378-402 (2007).
    • (2007) J. Am. Coll. Cardiol. , vol.49 , Issue.3 , pp. 378-402
    • Greenland, P.1    Bonow, R.O.2    Brundage, B.H.3
  • 34
    • 34548587074 scopus 로고    scopus 로고
    • Added value of coronary artery calcium score as an adjunct to gated SPECT for the evaluation of coronary artery disease in an intermediate-risk population
    • Schepis T, Gaemperli O, Koepfli P et al. Added value of coronary artery calcium score as an adjunct to gated SPECT for the evaluation of coronary artery disease in an intermediate-risk population. J. Nucl. Med. 48(9), 1424-1430 (2007).
    • (2007) J. Nucl. Med. , vol.48 , Issue.9 , pp. 1424-1430
    • Schepis, T.1    Gaemperli, O.2    Koepfli, P.3
  • 35
    • 41649101202 scopus 로고    scopus 로고
    • Interrelation of coronary calcification, myocardial ischemia, and outcomes in patients with intermediate likelihood of coronary artery disease: A combined positron emission tomography/computed tomography study
    • Schenker MP, Dorbala S, Hong EC et al. Interrelation of coronary calcification, myocardial ischemia, and outcomes in patients with intermediate likelihood of coronary artery disease: A combined positron emission tomography/computed tomography study. Circulation 117(13), 1693-1700 (2008).
    • (2008) Circulation , vol.117 , Issue.13 , pp. 1693-1700
    • Schenker, M.P.1    Dorbala, S.2    Hong, E.C.3
  • 36
    • 38049151278 scopus 로고    scopus 로고
    • Applications and software techniques for integrated cardiac multimodality imaging
    • Slomka PJ, Berman DS, Germano G. Applications and software techniques for integrated cardiac multimodality imaging. Exp. Rev. Cardiovasc. Ther. 6(1), 27-41 (2008).
    • (2008) Exp. Rev. Cardiovasc. Ther. , vol.6 , Issue.1 , pp. 27-41
    • Slomka, P.J.1    Berman, D.S.2    Germano, G.3
  • 38
    • 79551578904 scopus 로고    scopus 로고
    • Hybrid cardiac imaging: SPECT/CT and PET/CT. A joint position statement by the European Association of Nuclear Medicine (EANM), the European Society of Cardiac Radiology (ESCR) and the European Council of Nuclear Cardiology (ECNC)
    • Flotats A, Knuuti J, Gutberlet M et al. Hybrid cardiac imaging: SPECT/CT and PET/CT. A joint position statement by the European Association of Nuclear Medicine (EANM), the European Society of Cardiac Radiology (ESCR) and the European Council of Nuclear Cardiology (ECNC). Eur. J. Nucl. Med. Mol. Imaging 38(1), 201-212 (2011).
    • (2011) Eur. J. Nucl. Med. Mol. Imaging , vol.38 , Issue.1 , pp. 201-212
    • Flotats, A.1    Knuuti, J.2    Gutberlet, M.3
  • 39
    • 84872009335 scopus 로고    scopus 로고
    • Hybrid imaging using quantitative H215O PET and CT-based coronary angiography for the detection of coronary artery disease
    • Danad I, Raijmakers PG, Appelman YE et al. Hybrid imaging using quantitative H215O PET and CT-based coronary angiography for the detection of coronary artery disease. J. Nucl. Med. 54, 55-63 (2013).
    • (2013) J. Nucl. Med. , vol.54 , pp. 55-63
    • Danad, I.1    Raijmakers, P.G.2    Appelman, Y.E.3
  • 40
    • 23044484009 scopus 로고    scopus 로고
    • Integrated PET/CT for the assessment of coronary artery disease: A feasibility study
    • Namdar M, Hany TF, Koepfli P et al. Integrated PET/CT for the assessment of coronary artery disease: A feasibility study. J. Nucl. Med. 46(6), 930-935 (2005).
    • (2005) J. Nucl. Med. , vol.46 , Issue.6 , pp. 930-935
    • Namdar, M.1    Hany, T.F.2    Koepfli, P.3
  • 41
    • 80054836016 scopus 로고    scopus 로고
    • The potential value of hybrid positron emission tomography/dual-source computed tomography imaging in coronary bypass surgery
    • Plass A, Emmert MY, Gaemperli O et al. The potential value of hybrid positron emission tomography/dual-source computed tomography imaging in coronary bypass surgery. Heart Surg. Forum 14(5), E283-E290 (2011).
    • (2011) Heart Surg. Forum , vol.14 , Issue.5
    • Plass, A.1    Emmert, M.Y.2    Gaemperli, O.3
  • 42
    • 84864036468 scopus 로고    scopus 로고
    • Automatic alignment of myocardial perfusion PET and 64-slice coronary CT angiography on hybrid PET/CT
    • Nakazato R, Dey D, Alexánderson E et al. Automatic alignment of myocardial perfusion PET and 64-slice coronary CT angiography on hybrid PET/CT. J. Nucl. Cardiol. 19(3), 482-491 (2012).
    • (2012) J. Nucl. Cardiol. , vol.19 , Issue.3 , pp. 482-491
    • Nakazato, R.1    Dey, D.2    Alexánderson, E.3
  • 43
    • 32044472882 scopus 로고    scopus 로고
    • Diagnostic accuracy of rest/stress ECG-gated Rb-82 myocardial perfusion PET: Comparison with ECG-gated Tc-99m sestamibi SPECT
    • Bateman TM, Heller GV, Mcghie AI et al. Diagnostic accuracy of rest/stress ECG-gated Rb-82 myocardial perfusion PET: comparison with ECG-gated Tc-99m sestamibi SPECT. J. Nucl. Cardiol. 13(1), 24-33 (2006).
    • (2006) J. Nucl. Cardiol. , vol.13 , Issue.1 , pp. 24-33
    • Bateman, T.M.1    Heller, G.V.2    McGhie, A.I.3
  • 44
    • 84867840857 scopus 로고    scopus 로고
    • Does rubidium-82 PET have superior accuracy to SPECT perfusion imaging for the diagnosis of obstructive coronary disease? A systematic review and meta-analysis
    • McArdle BA, Dowsley TF, Dekemp RA, Wells GA, Beanlands RS. Does rubidium-82 PET have superior accuracy to SPECT perfusion imaging for the diagnosis of obstructive coronary disease? A systematic review and meta-analysis. J. Am. Coll. Cardiol. 60(18), 1828-1837 (2012).
    • (2012) J. Am. Coll. Cardiol. , vol.60 , Issue.18 , pp. 1828-1837
    • McArdle, B.A.1    Dowsley, T.F.2    Dekemp, R.A.3    Wells, G.A.4    Beanlands, R.S.5
  • 45
    • 67650112190 scopus 로고    scopus 로고
    • Incremental prognostic value of gated Rb-82 positron emission tomography myocardial perfusion imaging over clinical variables and rest LVEF
    • Dorbala S, Hachamovitch R, Curillova Z et al. Incremental prognostic value of gated Rb-82 positron emission tomography myocardial perfusion imaging over clinical variables and rest LVEF. JACC Cardiovasc. Imaging 2(7), 846-854 (2009).
    • (2009) JACC Cardiovasc. Imaging , vol.2 , Issue.7 , pp. 846-854
    • Dorbala, S.1    Hachamovitch, R.2    Curillova, Z.3
  • 46
  • 47
    • 84861505429 scopus 로고    scopus 로고
    • Physical attributes, limitations, and future potential for PET and SPECT
    • Garcia EV. Physical attributes, limitations, and future potential for PET and SPECT. J. Nucl. Cardiol. 19(Suppl. 1), S19-S29 (2012).
    • (2012) J. Nucl. Cardiol. , vol.19 , Issue.SUPPL. 1
    • Garcia, E.V.1
  • 48
    • 77949490328 scopus 로고    scopus 로고
    • PET/ CT challenge for the non-invasive diagnosis of coronary artery disease
    • Schwaiger M, Ziegler SI, Nekolla SG. PET/ CT challenge for the non-invasive diagnosis of coronary artery disease. Eur. J. Radiol. 73(3), 494-503 (2010).
    • (2010) Eur. J. Radiol. , vol.73 , Issue.3 , pp. 494-503
    • Schwaiger, M.1    Ziegler, S.I.2    Nekolla, S.G.3
  • 49
    • 84868213305 scopus 로고    scopus 로고
    • PET: Is myocardial flow quantification a clinical reality? J
    • Saraste A, Kajander S, Han C, Nesterov SV, Knuuti J. PET: is myocardial flow quantification a clinical reality? J. Nucl. Cardiol. 19(5), 1044-1059 (2012).
    • (2012) Nucl. Cardiol. , vol.19 , Issue.5 , pp. 1044-1059
    • Saraste, A.1    Kajander, S.2    Han, C.3    Nesterov, S.V.4    Knuuti, J.5
  • 50
    • 0034745220 scopus 로고    scopus 로고
    • Use of [11C]acetate and [15O]O2 PET for the assessment of myocardial oxygen utilization in patients with chronic myocardial infarction
    • Ukkonen H, Knuuti J, Katoh C et al. Use of [11C]acetate and [15O]O2 PET for the assessment of myocardial oxygen utilization in patients with chronic myocardial infarction. Eur. J. Nucl. Med. 28(3), 334-339 (2001).
    • (2001) Eur. J. Nucl. Med. , vol.28 , Issue.3 , pp. 334-339
    • Ukkonen, H.1    Knuuti, J.2    Katoh, C.3