메뉴 건너뛰기




Volumn 16, Issue 1, 2012, Pages 169-180

Influence of implant shape, surface morphology, surgical technique and bone quality on the primary stability of dental implants

Author keywords

Dental implants; Insertion torque; Primary stability; Removal torque

Indexed keywords

BONE; IMPLANTS (SURGICAL); MORPHOLOGY; STABILITY; SURFACE MORPHOLOGY; SURGERY; TORQUE;

EID: 84872688484     PISSN: 17516161     EISSN: 18780180     Source Type: Journal    
DOI: 10.1016/j.jmbbm.2012.10.010     Document Type: Article
Times cited : (151)

References (34)
  • 1
    • 84861632701 scopus 로고    scopus 로고
    • Differences in implant stability associated with various methods of preparation of the implant bed: an in vitro study
    • Ahn, S-J., Leesungbok, R., Lee, S-W., Heo, Y-K., Kang, K.L., 2012. Differences in implant stability associated with various methods of preparation of the implant bed: an in vitro study. Journal of Prosthetic Dentistry 107, 366-372.
    • (2012) Journal of Prosthetic Dentistry , vol.107 , pp. 366-372
    • Ahn, S.-J.1    Leesungbok, R.2    Lee, S.-W.3    Heo, Y.-K.4    Kang, K.L.5
  • 2
    • 0019435541 scopus 로고
    • Osseointegrated titanium implants: requirements for ensuring a long-lasting, direct bone to implant anchorage in man
    • Albrektsson, T., Branemark, P-I., Hansson, H.A., Lindstrom, J., 1981. Osseointegrated titanium implants: requirements for ensuring a long-lasting, direct bone to implant anchorage in man. Acta Orthopaedica Scandinavica 52, 155-170.
    • (1981) Acta Orthopaedica Scandinavica , vol.52 , pp. 155-170
    • Albrektsson, T.1    Branemark, P.-I.2    Hansson, H.A.3    Lindstrom, J.4
  • 3
    • 82255170810 scopus 로고    scopus 로고
    • Undersized implant site preparation to enhance primary implant stability in poor bone density: a prospective clinical study
    • Alghamadi, H., Anad, P.S., Sukumaran, A., 2011. Undersized implant site preparation to enhance primary implant stability in poor bone density: a prospective clinical study. Journal of Maxillofacial and Oral Surgery 69 (12), e506-e512.
    • (2011) Journal of Maxillofacial and Oral Surgery , vol.69 , Issue.12
    • Alghamadi, H.1    Anad, P.S.2    Sukumaran, A.3
  • 4
    • 77949905454 scopus 로고    scopus 로고
    • Quantifying the influence of bone density and thickness on resonance frequency analysis: an in vitro study of biomechanical test materials
    • Bardy, T., Gedet, P., Hallermann, W., Buchler, P., 2009. Quantifying the influence of bone density and thickness on resonance frequency analysis: an in vitro study of biomechanical test materials. International Journal of Oral and Maxillofacial Implants 24, 1006-1014.
    • (2009) International Journal of Oral and Maxillofacial Implants , vol.24 , pp. 1006-1014
    • Bardy, T.1    Gedet, P.2    Hallermann, W.3    Buchler, P.4
  • 7
    • 0031061750 scopus 로고    scopus 로고
    • Implant-retained mandibular overdentures with immediate loading: a retrospective multicenter study on 226 consecutive cases
    • Chiapasco, M., Gatti, C., Rossi, E., Haefliger, W., Markwalder, T.H., 1997. Implant-retained mandibular overdentures with immediate loading: a retrospective multicenter study on 226 consecutive cases. Clinical Oral Implants Research 8, 48-57.
    • (1997) Clinical Oral Implants Research , vol.8 , pp. 48-57
    • Chiapasco, M.1    Gatti, C.2    Rossi, E.3    Haefliger, W.4    Markwalder, T.H.5
  • 8
    • 81255136900 scopus 로고    scopus 로고
    • The effect of different implant macrogeometries and surface treatment in early biomechanical fixation: an experimental study in dogs
    • Coelho, P.G., Granato, R., Marin, C., Teixeira, H.S., 2011. The effect of different implant macrogeometries and surface treatment in early biomechanical fixation: an experimental study in dogs. Journal of Mechanical Behavior of Biomedical Materials 27 (4), 1974-1981.
    • (2011) Journal of Mechanical Behavior of Biomedical Materials , vol.27 , Issue.4 , pp. 1974-1981
    • Coelho, P.G.1    Granato, R.2    Marin, C.3    Teixeira, H.S.4
  • 9
    • 50849120381 scopus 로고    scopus 로고
    • Immediate versus delayed loading of dental implants placed in fresh extraction sockets in the maxillary esthetic zone
    • Crespi, R., Cappare, P., Gherlone, E., Romanos, G.E., 2008. Immediate versus delayed loading of dental implants placed in fresh extraction sockets in the maxillary esthetic zone. International Journal of Oral & Maxillofacial Implants 23, 753-758.
    • (2008) International Journal of Oral & Maxillofacial Implants , vol.23 , pp. 753-758
    • Crespi, R.1    Cappare, P.2    Gherlone, E.3    Romanos, G.E.4
  • 10
    • 16844384221 scopus 로고    scopus 로고
    • 7-Year follow-up of 93 immediately loaded titanium dental implants
    • Degidi, M., Piattelli, A., 2005. 7-Year follow-up of 93 immediately loaded titanium dental implants. Journal of Oral Implantology 31, 25-31.
    • (2005) Journal of Oral Implantology , vol.31 , pp. 25-31
    • Degidi, M.1    Piattelli, A.2
  • 16
    • 49949151805 scopus 로고    scopus 로고
    • Relationship between surface properties (roughness, wettability and morphology) of titanium and dental implant removal torque
    • Elias, C.N., Oshida, Y., Lima, J.H.C., Muller, C.A., 2008. Relationship between surface properties (roughness, wettability and morphology) of titanium and dental implant removal torque. Journal of Mechanical Behavior of Biomedical Materials 23 (4), 234-242.
    • (2008) Journal of Mechanical Behavior of Biomedical Materials , vol.23 , Issue.4 , pp. 234-242
    • Elias, C.N.1    Oshida, Y.2    Lima, J.H.C.3    Muller, C.A.4
  • 18
    • 17844385046 scopus 로고    scopus 로고
    • Evaluation of patient and implant characteristics as potential prognostic factors for oral implant failures
    • Herrmann, I., Lekholm, U., Holm, S., Kultje, C., 2005. Evaluation of patient and implant characteristics as potential prognostic factors for oral implant failures. International Journal of Oral Maxillofacial Implants 20, 220-230.
    • (2005) International Journal of Oral Maxillofacial Implants , vol.20 , pp. 220-230
    • Herrmann, I.1    Lekholm, U.2    Holm, S.3    Kultje, C.4
  • 19
    • 77953707372 scopus 로고    scopus 로고
    • The role of primary stability for successful immediate loading of dental implants
    • Javed, F., Romanos, G.E., 2010. The role of primary stability for successful immediate loading of dental implants. A literature review. Journal of Dentistry 38, 612-620.
    • (2010) A literature review, Journal of Dentistry , vol.38 , pp. 612-620
    • Javed, F.1    Romanos, G.E.2
  • 20
    • 80055079367 scopus 로고    scopus 로고
    • Self-cutting blades and their influence on primary stability of tapered dental implants in a simulated low-density bone model: a laboratory study
    • Kim, D.R., Lim, Y.J., Kim, M.J., Kwon, H.B., Kim, S.H., 2011. Self-cutting blades and their influence on primary stability of tapered dental implants in a simulated low-density bone model: a laboratory study. Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology and Endodontology 112 (5), 573-580.
    • (2011) Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology and Endodontology , vol.112 , Issue.5 , pp. 573-580
    • Kim, D.R.1    Lim, Y.J.2    Kim, M.J.3    Kwon, H.B.4    Kim, S.H.5
  • 21
    • 0037620615 scopus 로고
    • In: Tissue-Integrated Prostheses: Osseointegration in Clinical Dentistry, Quintessence International Ed., Chicago
    • Lekholm, U., Zarb, G.A., 1985. Patient selection and preparation. In: Tissue-Integrated Prostheses: Osseointegration in Clinical Dentistry, Quintessence International Ed., Chicago, pp. 199-209.
    • (1985) Patient selection and preparation , pp. 199-209
    • Lekholm, U.1    Zarb, G.A.2
  • 25
    • 33644863108 scopus 로고    scopus 로고
    • The effects of implant surface roughness and surgical technique on implant fixation in an in vitro model
    • Shalabi, M.M., Wolke, J.G., Jansen, J.A., 2006. The effects of implant surface roughness and surgical technique on implant fixation in an in vitro model. Clinical Oral Implants Research 17, 172-178.
    • (2006) Clinical Oral Implants Research , vol.17 , pp. 172-178
    • Shalabi, M.M.1    Wolke, J.G.2    Jansen, J.A.3
  • 26
    • 84872677534 scopus 로고
    • Shigley, J.E., 1977. Mechanical Engineering Design. McGraw Hill Kogakusha Ltd.
    • (1977)
    • Shigley, J.E.1
  • 27
    • 0034139407 scopus 로고    scopus 로고
    • Considerations preliminary to the application of early and immediate loading protocols in implant dentistry
    • Szmukler-Moncler, S., Piattelli, A., Favero, J.A., Dubruille, J.H., 2000. Considerations preliminary to the application of early and immediate loading protocols in implant dentistry. Clinical Oral Implants Research 11, 12-25.
    • (2000) Clinical Oral Implants Research , vol.11 , pp. 12-25
    • Szmukler-Moncler, S.1    Piattelli, A.2    Favero, J.A.3    Dubruille, J.H.4
  • 29
    • 62249165049 scopus 로고    scopus 로고
    • Influence of the surgical technique and surface roughness on the primary stability of an implant in artificial bone with a density equivalent to maxillary bone: a laboratory study
    • Tabassum, A., Meijer, G.J., Wolke, J.G.C., Jansen, J.A., 2009. Influence of the surgical technique and surface roughness on the primary stability of an implant in artificial bone with a density equivalent to maxillary bone: a laboratory study. Clinical Oral Implant Research 20, 327-332.
    • (2009) Clinical Oral Implant Research , vol.20 , pp. 327-332
    • Tabassum, A.1    Meijer, G.J.2    Wolke, J.G.C.3    Jansen, J.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.