메뉴 건너뛰기




Volumn 3, Issue 12, 2012, Pages 3211-3222

A diffuse reflectance spectral imaging system for tumor margin assessment using custom annular photodiode arrays

Author keywords

[No Author keywords available]

Indexed keywords

DIODES; OPTIMIZATION; PHOTODETECTORS; PHOTONS; PROBES; SPECTROSCOPY;

EID: 84870759972     PISSN: None     EISSN: 21567085     Source Type: Journal    
DOI: 10.1364/BOE.3.003211     Document Type: Article
Times cited : (20)

References (30)
  • 1
    • 60849133932 scopus 로고    scopus 로고
    • Lookup table-based inverse model for determining optical properties of turbid media
    • N. Rajaram, T. H. Nguyen, and J. W. Tunnell, "Lookup table-based inverse model for determining optical properties of turbid media," J. Biomed. Opt. 13(5), 050501 (2008).
    • (2008) J. Biomed. Opt , vol.13 , Issue.5 , pp. 050501
    • Rajaram, N.1    Nguyen, T.H.2    Tunnell, J.W.3
  • 3
    • 0001751901 scopus 로고    scopus 로고
    • Photon migration through a turbid slab described by a model based on diffusion approximation. I. Theory
    • D. Contini, F. Martelli, and G. Zaccanti, "Photon migration through a turbid slab described by a model based on diffusion approximation. I. Theory," Appl. Opt. 36(19), 4587-4599 (1997).
    • (1997) Appl. Opt , vol.36 , Issue.19 , pp. 4587-4599
    • Contini, D.1    Martelli, F.2    Zaccanti, G.3
  • 4
    • 33645157161 scopus 로고    scopus 로고
    • Monte Carlo-based inverse model for calculating tissue optical properties. Part I: Theory and validation on synthetic phantoms
    • G. M. Palmer and N. Ramanujam, "Monte Carlo-based inverse model for calculating tissue optical properties. Part I: Theory and validation on synthetic phantoms," Appl. Opt. 45(5), 1062-1071 (2006).
    • (2006) Appl. Opt , vol.45 , Issue.5 , pp. 1062-1071
    • Palmer, G.M.1    Ramanujam, N.2
  • 5
    • 0029045693 scopus 로고
    • MCML--Monte Carlo modeling of light transport in multi-layered tissues
    • L. Wang, S. L. Jacques, and L. Zheng, "MCML--Monte Carlo modeling of light transport in multi-layered tissues," Comput. Methods Programs Biomed. 47(2), 131-146 (1995).
    • (1995) Comput. Methods Programs Biomed , vol.47 , Issue.2 , pp. 131-146
    • Wang, L.1    Jacques, S.L.2    Zheng, L.3
  • 6
    • 84856405874 scopus 로고    scopus 로고
    • Portable optical fiber probe-based spectroscopic scanner for rapid cancer diagnosis: A new tool for intraoperative margin assessment
    • N. Lue, J. W. Kang, C.-C. Yu, I. Barman, N. C. Dingari, M. S. Feld, R. R. Dasari, and M. Fitzmaurice, "Portable optical fiber probe-based spectroscopic scanner for rapid cancer diagnosis: a new tool for intraoperative margin assessment," PLoS ONE 7(1), e30887 (2012).
    • (2012) PLoS ONE , vol.7 , Issue.1
    • Lue, N.1    Kang, J.W.2    Yu, C.-C.3    Barman, I.4    Dingari, N.C.5    Feld, M.S.6    Dasari, R.R.7    Fitzmaurice, M.8
  • 8
    • 79955436407 scopus 로고    scopus 로고
    • SUROS
    • SUROS, "New method for breast cancer diagnosis," 2003, http://www2.prnewswire.com/cgibin/stories.pl?ACCT=104&STORY=/www/story/11-25-2003/0002065545&EDATE=.
    • (2003) New Method For Breast Cancer Diagnosis
  • 9
    • 41549148650 scopus 로고    scopus 로고
    • Positive margins: The challenge continues for breast surgeons
    • L. Jacobs, "Positive margins: the challenge continues for breast surgeons," Ann. Surg. Oncol. 15(5), 1271-1272 (2008).
    • (2008) Ann. Surg. Oncol , vol.15 , Issue.5 , pp. 1271-1272
    • Jacobs, L.1
  • 10
    • 33748417556 scopus 로고    scopus 로고
    • The influence of additional surgical margins on the total specimen volume excised and the reoperative rate after breast-conserving surgery
    • T. L. Huston, R. Pigalarga, M. P. Osborne, and E. Tousimis, "The influence of additional surgical margins on the total specimen volume excised and the reoperative rate after breast-conserving surgery," Am. J. Surg. 192(4), 509-512 (2006).
    • (2006) Am. J. Surg , vol.192 , Issue.4 , pp. 509-512
    • Huston, T.L.1    Pigalarga, R.2    Osborne, M.P.3    Tousimis, E.4
  • 11
    • 14944347508 scopus 로고    scopus 로고
    • Accuracy of intraoperative gross examination of surgical margin status in women undergoing partial mastectomy for breast malignancy
    • discussion 27-28
    • G. C. Balch, S. K. Mithani, J. F. Simpson, and M. C. Kelley, "Accuracy of intraoperative gross examination of surgical margin status in women undergoing partial mastectomy for breast malignancy," Am. Surg. 71(1), 22-27, discussion 27-28 (2005).
    • (2005) Am. Surg , vol.71 , Issue.1 , pp. 22-27
    • Balch, G.C.1    Mithani, S.K.2    Simpson, J.F.3    Kelley, M.C.4
  • 13
    • 77953604788 scopus 로고    scopus 로고
    • A low-cost, portable, and quantitative spectral imaging system for application to biological tissues
    • H. L. Fu, B. Yu, J. Y. Lo, G. M. Palmer, T. F. Kuech, and N. Ramanujam, "A low-cost, portable, and quantitative spectral imaging system for application to biological tissues," Opt. Express 18(12), 12630-12645 (2010).
    • (2010) Opt. Express , vol.18 , Issue.12 , pp. 12630-12645
    • Fu, H.L.1    Yu, B.2    Lo, J.Y.3    Palmer, G.M.4    Kuech, T.F.5    Ramanujam, N.6
  • 14
    • 59749102493 scopus 로고    scopus 로고
    • A strategy for quantitative spectral imaging of tissue absorption and scattering using light emitting diodes and photodiodes
    • J. Y. Lo, B. Yu, H. L. Fu, J. E. Bender, G. M. Palmer, T. F. Kuech, and N. Ramanujam, "A strategy for quantitative spectral imaging of tissue absorption and scattering using light emitting diodes and photodiodes," Opt. Express 17(3), 1372-1384 (2009).
    • (2009) Opt. Express , vol.17 , Issue.3 , pp. 1372-1384
    • Lo, J.Y.1    Yu, B.2    Fu, H.L.3    Bender, J.E.4    Palmer, G.M.5    Kuech, T.F.6    Ramanujam, N.7
  • 15
    • 62449230776 scopus 로고    scopus 로고
    • Cost-effective diffuse reflectance spectroscopy device for quantifying tissue absorption and scattering in vivo
    • B. Yu, J. Y. Lo, T. F. Kuech, G. M. Palmer, J. E. Bender, and N. Ramanujam, "Cost-effective diffuse reflectance spectroscopy device for quantifying tissue absorption and scattering in vivo," J. Biomed. Opt. 13(6), 060505 (2008).
    • (2008) J. Biomed. Opt , vol.13 , Issue.6 , pp. 060505
    • Yu, B.1    Lo, J.Y.2    Kuech, T.F.3    Palmer, G.M.4    Bender, J.E.R.5
  • 16
    • 77953900841 scopus 로고    scopus 로고
    • High quantum efficiency annular backside silicon photodiodes for reflectance pulse oximetry in wearable wireless body sensors
    • S. Duun, R. G. Haahr, O. Hansen, K. Birkelund, and E. V. Thomsen, "High quantum efficiency annular backside silicon photodiodes for reflectance pulse oximetry in wearable wireless body sensors," J. Micromech. Microeng. 20(7), 075020 (2010).
    • (2010) J. Micromech. Microeng , vol.20 , Issue.7 , pp. 075020
    • Duun, S.1    Haahr, R.G.2    Hansen, O.3    Birkelund, K.4    Thomsen, E.V.5
  • 17
    • 84893894717 scopus 로고    scopus 로고
    • Wavelength optimization for quantitative spectral imaging of breast tumor margins
    • J.Y. Lo, J.Q. Brown, S. Dhar, B. Yu, N.M. Jokerst, and N. Ramanujam, "Wavelength optimization for quantitative spectral imaging of breast tumor margins," submitted to PLoS ONE.
    • PLoS ONE
    • Lo, J.Y.1    Brown, J.Q.2    Dhar, S.3    Yu, B.4    Jokerst, N.M.5    Ramanujam, N.6
  • 20
    • 0035307668 scopus 로고    scopus 로고
    • Surface recombination velocity of phosphorus-diffused silicon solar cell emitters passivated with plasma enhanced chemical vapor deposited silicon nitride and thermal silicon oxide
    • M. J. Kerr, J. Schmidt, A. Cuevas, and J. H. Bultman, "Surface recombination velocity of phosphorus-diffused silicon solar cell emitters passivated with plasma enhanced chemical vapor deposited silicon nitride and thermal silicon oxide," J. Appl. Phys. 89(7), 3821-3826 (2001).
    • (2001) J. Appl. Phys , vol.89 , Issue.7 , pp. 3821-3826
    • Kerr, M.J.1    Schmidt, J.2    Cuevas, A.3    Bultman, J.H.4
  • 24
    • 33751200713 scopus 로고    scopus 로고
    • 4th ed, Addison Wesley
    • E. Hecht, Optics, 4th ed. (Addison Wesley, 2001).
    • (2001) Optics
    • Hecht, E.1
  • 26
    • 84870753075 scopus 로고    scopus 로고
    • PICAXE microcontroller, available from
    • PICAXE microcontroller, available from http://www.picaxe.com/.
  • 27
    • 84870755536 scopus 로고    scopus 로고
    • Advancing optical imaging for breast margin assessment: An analysis of excisional time, cautery, and and patent blue dye on underlying sources of contrast
    • to be published
    • T. M. Bydlon, W. T. Barry, S. A. Kennedy, J. Q. Brown, J. Gallagher, L. G. Wilke, J. Geradts, and N. Ramanujam, "Advancing optical imaging for breast margin assessment: an analysis of excisional time, cautery, and and patent blue dye on underlying sources of contrast," PLoS ONE (to be published).
    • PLoS ONE
    • Bydlon, T.M.1    Barry, W.T.2    Kennedy, S.A.3    Brown, J.Q.4    Gallagher, J.5    Wilke, L.G.6    Geradts, J.7    Ramanujam, N.8
  • 28
    • 33645157161 scopus 로고    scopus 로고
    • Monte Carlo-based inverse model for calculating tissue optical properties. Part I: Theory and validation on synthetic phantoms
    • G. M. Palmer and N. Ramanujam, "Monte Carlo-based inverse model for calculating tissue optical properties. Part I: Theory and validation on synthetic phantoms," Appl. Opt. 45(5), 1062-1071 (2006).
    • (2006) Appl. Opt , vol.45 , Issue.5 , pp. 1062-1071
    • Palmer, G.M.1    Ramanujam, N.2
  • 30
    • 0020102122 scopus 로고
    • Silicon oxynitride; a material for GRIN optics
    • T. Bååk, "Silicon oxynitride; a material for GRIN optics," Appl. Opt. 21(6), 1069-1072 (1982).
    • (1982) Appl. Opt , vol.21 , Issue.6 , pp. 1069-1072
    • Bååk, T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.